共查询到20条相似文献,搜索用时 0 毫秒
1.
《Electrophoresis》2018,39(8):1054-1061
To separate and extract the native states of lysozyme from chicken egg white, a hybrid method for the mobilization of proteins after non‐denaturing gel isoelectric focusing (IEF) combined with detection of lysozyme activity was developed. When the proteins in the chicken egg white were first separated using non‐denaturing gel IEF, a lysozyme was obtained at the top of the gel column at the cathode end of the IEF. And, when the IEF‐separated proteins of the egg white were mobilized by replacing the cathodic sodium hydroxide solution with phosphoric acid solution, an additional active state of the lysozyme that could be bound to proteins, such as ovotransferrin, was extracted from the solution. Furthermore, it was shown that the addition of lysozyme, obtained via IEF, to pure ovotransferrin generated a complex manifesting lysozyme activity, clearly indicating a successful reconstruction of the lysozyme‐ovotransferrin complex in vitro. Therefore, the obtained results demonstrated that the native states of lysozymes, such as lysozyme and the lysozyme‐ovotransferrin complex, can be effectively separated and extracted using non‐denaturing gel IEF. Thus, this method can be applied to separate and extract different charge states of native proteins that retain their biological activities. 相似文献
2.
Two-stage Off-Gel isoelectric focusing: protein followed by peptide fractionation and application to proteome analysis of human plasma 总被引:1,自引:0,他引:1
Heller M Michel PE Morier P Crettaz D Wenz C Tissot JD Reymond F Rossier JS 《Electrophoresis》2005,26(6):1174-1188
This paper presents the recently introduced Off-Gel electrophoresis (OGE) technology as a versatile tool to reproducibly fractionate intact proteins and peptides into discrete liquid fractions. The coupling of two stages of OGE, i.e., the separation of intact proteins in a first-stage followed by fractionation of peptides derived from each protein fraction after proteolysis in a second stage, results in an array of 15 x 15 fractions that are directly amenable to additional peptide fractionation like reverse-phase liquid chromatography (RPC). The analysis of all second-stage peptide fractions from only the first-stage protein fraction representing pH 5.0 -5.15 by on-line reverse-phase LC-tandem mass spectrometry resulted in the identification of 53 proteins (337 peptides), of which 10 were on different immunoglobulin (Ig) chains, with an input of only 1.5 mg human blood plasma proteins. Increasing the protein load to approximately 12 mg increased the number of identified proteins in the same protein fraction to 73 proteins (449 peptides), of which 15 were Ig-related. Immunodepletion of six of the most abundant proteins (albumin, transferrin, haptoglobin, IgG, IgA, and alpha-1-antitrypsin) prior to first-stage OGE with an input of 1.5 mg of protein (equivalent to approximately 10 mg nondepleted plasma) resulted in the identification of 81 proteins (660 peptides), of which three were still Ig fragments. The pI-based separation of peptides appears to be nonuniform based on the theoretically determined pI values of identified peptides. This observation specifically accounts for the neutral zone (pI 5-8) and can be accounted for by the physicochemical properties of the peptides given by their amino acid composition. The power of OGE separation of proteins and peptides is discussed with a focus on the use of the knowledge about the pI of proteins and peptides that assist the validation of correct identifications together with the retention time of peptides on RPC. 相似文献
3.
Capillary isoelectric focusing (CIEF) separations are usually performed with neutral coated fused-silica capillaries in aqueous anticonvective media. Glycerol, a very viscous solvent (eta = 945 mPa x s at 25 degrees C), known to help stabilize any kind of proteins and solubilize hydrophobic ones, was tested as an alternative to using commercial gels. Viscosity and electroosmotic mobility were measured as a function of gel or glycerol content in water, and a 30:70 v/v glycerol-water medium appeared as a good compromise for performing CIEF in a bare fused-silica capillary without imposing too high a viscosity. To demonstrate the feasibility of this new CIEF system, a standard mixture of nine model proteins was separated according to their pI with a good agreement between experimental and literature aqueous pIs. Moreover, better resolution was achieved with this system than with the conventional aqueous CIEF system, as two of the model proteins could not be separated in the latter system. Glycerol-water CIEF in bare silica capillary was next applied to the separation of horse radish peroxidase, a complex mixture of protein isoforms. The good concordance with the separation obtained by the conventional CIEF system indicated the adequacy of this new system. Finally, as anticipated from the results obtained for the separation of bacteriorhodopsin, a membrane protein, glycerol-water CIEF performed in bare silica capillary appears to be a promising alternative to conventional aqueous CIEF for hydrophobic protein characterization, under their native form. 相似文献
4.
Chao‐Ming Zhou 《Electrophoresis》2013,34(20-21):3046-3053
CIEF with whole‐column imaging detection (WCID) can be a useful tool for the characterization and identification of human papillomavirus (HPV). This article is the initial report of the determination of the pI of HPV by CIEF‐WCID method. In this study, components of the assay selected for optimization were ampholytes, additives, methylcellulose concentration, HPV concentration, salt concentration, and focusing time. Then the optimization CIEF‐WCID method was validated for HPV 16L1 and HPV 18L1. As a result, a precise method to analyze the pI values of HPVs was achieved with RSD < 1.0%. The HPV peak pattern was reproducible. CIEF‐WCID had great potential for HPV quality control, as WCID eliminated the mobilization step required by the conventional single‐point detection. In the example, the five HPVs displayed pI values of 8.43 ± 0.06 (n = 10; HPV 6L1), 8.70 ± 0.04 (n = 10; HPV 11L1), 7.94 ± 0.05 (n = 18; HPV 16L1), 7.57 ± 0.04 (n = 18; HPV 18L1), and 8.45 ± 0.05 (n = 10; HPV 58L1). This CIEF‐WCID platform could be a powerful analytical tool for characterization, process development support, release testing, and stability study in pharmaceutical industry. 相似文献
5.
Capillary isoelectric focusing is indispensable for characterizing charge heterogeneity and isoelectric points of biopharmaceuticals. However, there are many influencing parameters and therefore method development is challenging. This study was performed to obtain an in‐depth understanding of the imaged CIEF methodology by applying a design of experiments approach. To describe the parameter's effects as objectively as possible, a polynomial regression model was derived for the most important responses. For this purpose, the reference monoclonal antibody suggested by the National Institute of Standards and Technology (NISTmAb) was used as test molecule. The total concentration and the mixing ratio of two types of carrier ampholytes and the added amounts of urea and l ‐arginine were selected as factors. The effects of these factors on 13 different responses such as resolution or pI values were investigated. In order to reduce the total number of experiments, a d ‐optimal design with 20 different parameter combinations and six replicates each was chosen. The most significant effects of the four factors were shown for the parameters related to separation efficiency and peak position. In addition, the extent of the factor's effect could be assessed. Depending on the selected factor combination, the pI value can differ up to approximately 0.15 pI units and the resolution value between main peak and adjacent basic peak can range from approximately 1.6 to 2.5, for example. 相似文献
6.
Obermaier C Jankowski V Schmutzler C Bauer J Wildgruber R Infanger M Köhrle J Krause E Weber G Grimm D 《Electrophoresis》2005,26(11):2109-2116
The method of preparing protein mixtures for electrophoretic analysis of membrane-associated cell proteins was improved. By sonication, about one-half of the proteins of thyroid cells were released into the supernatant, while the other half preferentially comprising membrane proteins still remained in cell fragments, which could be sedimented by centrifugation. After sonication, even those proteins which remained in cell fragments, could completely be dissolved by free-flow isoelectric focusing media. They migrated through the free-flow electrophoresis chamber without forming precipitates. Because of these improvements, it was possible to show that the two thyroid cancer cell lines ML-1 and ONCO-DG1 express cytokeratin 8 at similar rates, but cytokeratins 7 and 18 differently. In addition, the presence of inorganic pyrophosphatase, tubulin-beta-5, and tubulin-beta-1 chains in human thyroid cells was proved for the first time. 相似文献
7.
Polyacrylamide gel electrophoresis (PAGE) is used frequently for isolation and purification of DNA fragments. In the present study, DNA fragments extracted from polyacrylamide gels showed significant band broadening in capillary electrophoresis (CE). A pHY300PLK (a shuttle vector functioning in Escherichia coli and Bacillus subtilis) marker, which contained nine fragments ranging from 80 to 4870 bp, was separated by PAGE, and each fragment was isolated by phenol/chloroform extraction and ethanol precipitation. After extraction from the polyacrylamide gel, the peaks of the isolated DNA fragments exhibited band broadening in CE, where a linear poly(ethylene oxide) was used as a sieving matrix. The theoretical plate numbers of the DNA fragments contained in the pHY300PLK marker were >106 for all the fragments before extraction. However, the DNA fragments extracted from the polyacrylamide gel showed decreased theoretical plate numbers (5–20 times smaller). The degradation of the theoretical plate number was significant for middle sizes of the DNA fragments ranging from 489 to 1360 bp, whereas the largest and smallest fragments (80 and 4870 bp) had no obvious influence. The band broadening was attributed to contamination of the DNA fragments by polyacrylamide fibers during the separation and extraction process. 相似文献
8.
Daming Zhu Weili Dai Prakash Srinivasan Holly McClellan Dennis Braden Alec Allee-Munoz Patricia A. Gonzales Hurtado Louis H. Miller Patrick E. Duffy 《Electrophoresis》2022,43(3):509-515
Rhoptry neck protein 2 (RON2) binds to the hydrophobic groove of apical membrane antigen 1 (AMA1), an interaction essential for invasion of red blood cells (RBCs) by Plasmodium falciparum (Pf) parasites. Vaccination with AMA1 alone has been shown to be immunogenic, but unprotective even against homologous challenge in human trials. However, the AMA1-RON2L (L is referred to as the loop region of RON2 peptide) complex is a promising candidate, as preclinical studies with Freund's adjuvant have indicated complete protection against lethal challenge in mice and superior protection against virulent infection in Aotus monkeys. To prepare for clinical trials of the AMA1-RON2L complex, identity and integrity of the candidate vaccine must be assessed, and characterization methods must be carefully designed to not dissociate the delicate complex during evaluation. In this study, we developed a native Tris-glycine gel method to separate and identify the AMA1-RON2L complex, which was further identified and confirmed by Western blotting using anti-AMA1 monoclonal antibodies (mAbs 4G2 and 2C2) and anti-RON2L polyclonal Ab coupled with mass spectrometry. The formation of complex was also confirmed by Capillary Isoelectric Focusing (cIEF). A short-term (48 h and 72 h at 4°C) stability study of AMA1-RON2L complex was also performed. The results indicate that the complex was stable for 72 h at 4°C. Our research demonstrates that the native Tris-glycine gel separation/Western blotting coupled with mass spectrometry and cIEF can fully characterize the identity and integrity of the AMA1–RON2L complex and provide useful quality control data for the subsequent clinical trials. 相似文献
9.
Electrokinetic processes that lead to pH gradient instabilities in carrier ampholyte-based IEF are reviewed. In addition to electroosmosis, there are four of electrophoretic nature, namely (i) the stabilizing phase with the plateau phenomenon, (ii) the gradual isotachophoretic loss of carrier ampholytes at the two column ends in presence of electrode solutions, (iii) the inequality of the mobilities of positively and negatively charged species of ampholytes, and (iv) the continuous penetration of carbonate from the catholyte into the focusing column. The impact of these factors to cathodic and anodic drifts was analyzed by simulation of carrier ampholyte-based focusing in closed and open columns. Focusing under realistic conditions within a 5 cm long capillary in which three amphoteric low molecular mass dyes were focused in a pH 3–10 gradient formed by 140 carrier ampholytes was investigated. In open columns, electroosmosis displaces the entire gradient toward the cathode or anode whereas the electrophoretic processes act bidirectionally with a transition around pH 4 (drifts for pI > 4 and pI < 4 typically toward the cathode and anode, respectively). The data illustrate that focused zones of carrier ampholytes have an electrophoretic flux and that dynamic simulation can be effectively used to assess the magnitude of each of the electrokinetic destabilizing factors and the resulting drift for a combination of these effects. Predicted drifts of focused marker dyes are compared to those observed experimentally in a setup with coated capillary and whole column optical imaging. 相似文献
10.
通过聚合物原位聚合反应,制备了部分填充的毛细管整体柱。pH 3~10的载体两性电解质被固化在该毛细管整体柱上。在引入八通进样阀、三通阀和四通连接单元的基础上,构建了适用于固化pH梯度毛细管等电聚焦整体柱(M-IPG)的平台。在蛋白质药物测定过程中,用M-IPG柱和羟丙基纤维素(HPC)涂层毛细管柱同时对曲托珠单抗和依那西谱的等电点进行了测定。结果表明,两种等电聚焦柱都能够同时分离混合蛋白质样品并测定蛋白质类药物中单抗和融合蛋白质的等电点(pI),M-IPG柱所测的pI值与HPC涂层毛细管柱测定的结果基本一致,表明了该柱在进一步构建多维分离平台进行蛋白质组学研究方面的潜力。 相似文献
11.
Szostek B Orska-Gawrys J Surowiec I Trojanowicz M 《Journal of chromatography. A》2003,1012(2):179-192
Liquid chromatography (LC) combined with ultraviolet-visible (UV-Vis) and mass spectrometric (MS) detection was utilized to study the chemical components present in extracts of natural dyes originating from fiber samples obtained from Coptic textiles from Early Christian Art Collection of National Museum in Warsaw. Chromatographic retention, ionization, UV-Vis and mass spectra of twenty selected dye compounds of flavanoid-, anthraquinone- and indigo-types were studied. Most of the investigated compounds could be ionized by positive and negative ion electrospray ionization. Difficulties with the ionization by electrospray were experienced for indigotin and brominated indigotins, but these were ionized by atmospheric pressure chemical ionization. Mass spectrometric detection, utilizing different scanning modes of a triple quadrupole mass spectrometer, combined with the UV-Vis detection was demonstrated to be a powerful approach to detection and identification of dyes in the extracts of archeological textiles. Using this approach the following compounds were identified in the extracts of Coptic textiles: luteolin, apigenin, rhamnetin, kaempferol, alizarin, purpurin, xanthopurpurin, monochloroalizarin, indirubin, and so the type of dye that was utilized to dye the textiles could be identified. Detection capabilities for several dye-type analytes were compared for the UV-Vis and mass spectrometric detection. The signal-to-noise ratios obtained for luteolin, apigenin, and rhamnetin were higher for the MS detection for most of the examined sample extracts. Purpurin, alizarin, and indirubin showed similar signal-to-noise ratios for UV-Vis and mass spectrometric detection. 相似文献
12.
《Journal of separation science》2017,40(11):2488-2497
Capillary electrophoresis analysis of transferrin in human serum is used to assess genetic variants after desialylation with neuraminidase and iron saturation to reduce the complexity of the transferrin pattern and thus facilitate the recognition of transferrin polymorphisms. Asialo‐transferrin forms are analyzed by capillary zone electrophoresis using assay conditions as for the monitoring of carbohydrate‐deficient transferrin or by capillary isoelectric focusing in a pH 5–8 gradient which requires immunoextraction of transferrin prior to analysis. With the carrier ampholytes used, peaks for iron saturated and iron depleted transferrin are monitored which indicates complexation of iron ions by carrier ampholytes. For BC, CD, and BD genetic variants, the expected peaks for B, C, and D forms of transferrin were detected with both methods. Monitoring of CC patterns revealed three cases, namely those producing double peaks in both methods, a double peak in capillary isoelectric focusing only and a double peak in capillary zone electrophoresis only. For all samples analyzed, data obtained by capillary isoelectric focusing could be confirmed with gel isoelectric focusing. The two capillary electrophoresis methods are shown to represent effective tools to assess unusual transferrin patterns, including genetic variants with dissimilar abundances of the two forms. 相似文献
13.
Synchrotron radiation X-ray fluorescence (SRXRF) spectroscopy is an advanced method of quantitative multielemental analysis with space resolution of several microm and sensitivities in the microg g(-1) range. It can be used for keeping track of trace elements after an electrophoretic separation of biological samples. In this paper, proteins in human liver cytosol were separated with gel filtration chromatography and thin layer isoelectric focusing (IEF). The contents of metal ions in protein bands were determined by SRXRF. The results showed that in the molecular weight (MW) range of 10 approximately 25 kDa, there were at least 2 Zn-containing bands with isoelectric point (pI) of 5 approximately 6 and 6.2 approximately 7, respectively and about 11 Fe-containing proteins with pI of 4.4, 4.6, 4.8, 5.0, 5.2, 5.3, 5.5, 5.6, 6.6, 6.8, and 7.2, respectively, present in human liver cytosol. The Zn-containing band with pI of 5-6 is the dominant species of zinc in this MW range. In addition, the Cu-containing bands with pI of 5.0 and below 4.8 were also detected. It is demonstrated that the procedure could be widely used in further investigations of the chemical species of trace elements in biological samples. 相似文献
14.
Simultaneous determination of purine bases, ribonucleosides and ribonucleotides was achieved by coupling capillary electrophoresis (CE) with wall-jet amperometric detection. A 200 μm diameter copper disk electrode was applied at working potential, +0.65 V vs. saturated calomel electrode. The current response of high sensitivity and stability was obtained in strong basic solutions which were suitable for satisfactory CE separations. The calibration curve was linear over 2–3 orders of magnitude and the limits of detection for adenine, guanine, xanthine, uric acid, adenosine, guanosine, adenosine-5′-monophosphate and guanosine-5′-monophosphate were below 9 fmol (S/N=3). The use of this method for the separation and detection of compounds present in human plasma samples was reported. 相似文献
15.
毛细管电泳-电化学检测益母草及其冲剂中的黄酮类化合物 总被引:7,自引:0,他引:7
用毛细管电泳-电化学检测(CE-ED)法同时测定了益母草及三种益母草冲剂中的根皮苷、橙皮素、芦丁、山奈酚、洋芹素和槲皮素六种黄酮类化合物的含量。考察了实验参数对分离、检测的影响,得到了最佳试验条件。采用300μm碳圆盘电极为工作电极,检测电位为 0.95 V(vs.SCE),在80 mmol/L的Na2B4O7-H3BO3(pH 8.7)的运行缓冲液中,上述各组分在20 min内能完全分离。根皮苷、橙皮素、芦丁、山奈酚、洋芹素、槲皮素在5.00×10-7~1.00×10-4g/mL范围内均与其相应的峰电流呈线性关系,其检出限(S/N=3)分别为4.68×10-7、2.03×10-7、4.68×10-7、2.68×10-7、4.81×10-7、3.61×10-7g/mL。该法应用于实际样品的分析,结果令人满意。 相似文献
16.
The photobehavior of pyrene (fine structure of the monomeric fluorescence band; excited state lifetimes; excimer/monomeric fluorescence intensity ratios and excited state quenching rates by oxygen) in fluid solutions of gelatin and in the gel state, both in the absence and presence of ionic surfactants, has been examined. Surfactants considered were sodium dodecylsulfate and dodecyltrimethylammonium bromide. Potentiometric measurements performed by using surfactant selective electrodes allowed for the determination of the binding capacity of the surfactants onto gelatin in the gel state. When complemented with viscosity and gel strength measurements, the sesults obtained allow for a discussion of the effects of the surfactant-gelatin interactions on microscopic properties of the solutions or gels and their relation with macroscopic properties. 相似文献
17.
Markuszewski MJ Otsuka K Terabe S Matsuda K Nishioka T 《Journal of chromatography. A》2003,1010(1):113-121
With a growing interest in metabolome analysis, there is a need for developing robust methods for analysis of intracellular metabolites profiles in real samples like e.g., bacteria cell. Due to their weak absorbance properties, tri- and dicarboxylic acids from TCA cycle (citric, isocitric, 2-oxoglutaric, succinic, fumaric, malic) as well as carboxylic acid metabolites from glycolysis pathway, urea cycle and metabolism of amino compounds (formic, pyruvic, lactic, acetic, glutamic) were analyzed by capillary electrophoresis (CE) with indirect UV detection. Using 4 mM 2,6-pyridinedicarboxylic acid as a highly UV absorbing carrier electrolyte, 0.2 mM cetyltrimethylammonium bromide, 10% ethylene glycol and 10% acetonitrile, pH 3.5, carboxylic acids metabolites were analyzed in Bacillus subtilis cell extract from two different cultures: glucose and malate. CE with an electrokinetic injection mode achieved limits of detection in the range of 13-54 ppb (1.12-10(-7) - 5.96-10(-7) M). The reproducibility and linearity of method was investigated with RSD for migration time less than 1.3% and acceptable correlation coefficients. The optimized CE method was used to compare metabolome content of cell extract derived from two different culture media containing either glucose or malate as a carbon source. The changes in carboxylic acid metabolites profile were observed depending from used culture medium. Carboxylic acid concentrations ranged: in cell extract from malate culture from 59 to 0.5 microM for lactate and citrate, respectively, and in cell extract from glucose culture from 133 to 0.5 microM for glutamate and citrate, respectively. Appropriate concentrations of carboxylic acid in the single bacterium cell were estimated at mM and sub-mM levels. 相似文献
18.
毛细管电泳-场强放大样品堆积法检测染发剂中的7种苯胺类物质 总被引:2,自引:0,他引:2
建立了毛细管电泳-场强放大样品堆积测定染发剂中4,4′-二氨基二苯甲烷、苯胺、邻甲氧基苯胺、对氨基苯甲醚、3,4-二甲基苯胺、间氨基苯酚、1-萘胺7种苯胺类物质的分析方法。在优化的缓冲溶液体系(0.15 mol/L NaH2PO4,0.015 mol/L 三乙醇胺, pH 2.3)下7种分析物在6.5 min内实现基线分离。考察了样品中添加的磷酸浓度和乙腈浓度、水柱长度、电动进样时间与电压对场强放大富集效率及重现性的影响。最佳的富集条件为: 水柱注入3.45 kPa(0.5 psi)×6 s,样品中添加40%(v/v)乙腈和0.6×10~3mol/L磷酸,进样电压与进样时间为10 kV×10 s。线性范围为3~1000 μg/L(R2>0.996),检出限为0.26~2.75 μg/L,将已有方法的检测灵敏度提高了1~3个数量级。在2种市售黑色染发剂中均检测到间氨基苯酚,含量分别为7.32 mg/g和1.34 mg/g。平均加标回收率为74%~108%。该方法灵敏度高、快速、重现性好、成本低,可供多种样品基质中痕量苯胺类污染物及其他阳离子物质的测定借鉴使用。 相似文献
19.
Microvesicles (MVs) have been shown to affect the physiology of neighboring recipient cells in various ways. They play an important role in tumor progression/metastasis and angiogenesis in cancer and may be useful therapeutic tools, as well as a mechanism of cell-to-cell communication. They have been visioned as an important biomarker or biomarker source for the detection of different diseases. Human saliva is a biological fluid with enormous diagnostic potential, which harbors plenty of salivary MVs. The goal of this study is to investigate the proteomic profiling of MVs in human saliva through a simple preparation procedure by using filtration and centrifugation. Gel electrophoresis was combined with LC–MS/MS (liquid chromatography–mass spectrometry) for the proteomic analysis of MVs. After SDS-PAGE (sodium dodecyl sulfate polyacrylamide gel electrophoresis) protein separation, the whole lane was cut into 25 bands, and each band was subjected to in-gel trypsin digestion. The peptides extracted from each band were loaded to LC–MS/MS for protein identification. Through protein database search, 63 proteins were identified for human salivary MVs. Several members of different protein families were identified, including annexin, keratin, actin, immunoglobulin and S100. This study showed that although there was an overlap with the proteins from human saliva and salivary exosomes, salivary MVs contained their own unique proteins. These results will poise human salivary MVs as a non-invasive tool for the early detection of different diseases. 相似文献
20.
Analysis of alpha-amino acids, proteins, and phenolic compounds was simultaneously performed using three capillaries in capillary electrophoresis with chemiluminescence detection, taking advantage of the micro-space area for reaction/detection at the tip of the capillary. The three capillaries included usual, polymer-containing, and sodium docley sulfate (SDS)-containing migration buffers for separation. The eluted samples from the capillaries, which were inserted into the chemiluminescence detection cell, were mixed with chemiluminescence reagent at the tips of the capillaries to generate visible light. The specific micro-space area for reaction/detection at the tips of the capillaries enabled the simultaneous operation of the three separation modes in the present system. 相似文献