1.
Novel monolithic supports (MS/BVPE) were prepared by thermally initiated free radical copolymerisation of p-methylstyrene (MS) and 1,2-bis(p-vinylphenyl)ethane (BVPE). The polymer was synthesised in fused silica capillaries (80 mm x 0.2 mm and 80 mm x 0.53 mm) and in borosilicate glass columns (90 mm x 1.0 mm and 90 mm x 3.0 mm) to yield different HPLC column designs. A comparison of those column dimensions regarding morphology as well as separation efficiency and applicability in bioanalysis is presented. The efficiency towards proteins as well as oligonucleotides was found to be considerably improved with decreasing column I.D. While a 5-protein mixture was baseline separated on all investigated column designs, the separation of small biomolecules like oligonucleotides or peptides on microbore and conventional size glass columns was strongly restricted in terms of resolution due to extensive peak broadening or the occurrence of peak asymmetry. Monolithic MS/BVPE capillary columns up to 0.53 mm I.D., however, proved to be applicable to the fractionation of the whole spectrum of biopolymers, including proteins, peptides, oligonucleotides as well as double-stranded DNA fragments. Due to the fact that reliable chromatography makes great demand on the robustness of the stationary phase, monolithic MS/BVPE capillaries were subjected to a comprehensive reproducibility study including run-to-run as well as batch-to-batch reproducibility.  相似文献   

2.
This paper describes a method for the selective screening of organophosphorus pesticides in water. In-tube solid-phase microextraction (SPME) in an open capillary column coupled to capillary liquid chromatography (LC) with UV detection has been used to effect preconcentration, separation and detection of the analytes in the same assembly. For in-tube SPME two capillary columns of the same length and different internal diameters and coating thicknesses have been tested and compared, a 30 cm x 0.25 mm I.D., 0.25 micro m thickness coating column, and a 30 cm x 0.1 mm I.D., 0.1 micro m of coating thickness column. In both columns the coating was 95% dimethylpolysiloxane (PDMS)-5% diphenylpolysiloxane. The proposed methodology provided limits of detections (LODs) for the tested organophosphorus pesticides in the 0.1-10 micro g/L range, whereas the direct injection of the samples onto the capillary LC system provided LODs in the 50-1000 micro g/L range. The sensitivity of the proposed in-tube SPME-capillary LC method is adequate to monitorize the analyte levels in drinking water. Several triazines, polycyclic aromatic hydrocarbons (PAHs), nonylphenol, organochloride pesticides or polybrominated diphenyl ethers (PBDEs) have been evaluated as possible interferents. The reliability of the described method is demonstrated by analysing different real water samples.  相似文献   

3.
Monolithic capillary columns were prepared via ring-opening metathesis polymerization (ROMP) using norborn-2-ene (NBE) and 1, 4, 4a, 5, 8, 8a-hexahydro-1, 4, 5, 8-exo,endo-dimethanonaphthalene (DMN-H6) as monomers. The monolithic polymer was copolymerized with Grubbs-type initiator RuCl(2)(PCy(3))(2)(CHPh) and a suitable porogenic system within the confines of fused silica capillaries of different inner diameter (I.D.). The first part of the study focused on batch-to-batch reproducibility of ROMP-derived capillary monoliths. Capillary monoliths of 200 microm I.D. showed good reproducibility in terms of retention times, with relative standard deviations (RSD) of 1.9% for proteins and 2.2% for peptides. However, the separately synthesized capillary monoliths revealed pronounced variation in back pressure with RSD values of up to 31%. These variations were considerably reduced by cooling of the capillaries during polymerization. Using this optimized preparation procedure capillary monoliths of 100 and 50 microm I.D. were synthesized and the effects of scaling down the column I.D. on the morphology and on the reproducibility of the polymerization process were investigated. In the second part, the applicability of ROMP-derived capillary monoliths to a separation problem common in medical research was assessed. A 200 microm I.D. monolithic column demonstrated excellent separation behavior for insulin and various insulin analogs, showing equivalent separation performance to Vydac C4 and Zorbax C3-based stationary phases. Moreover, the high permeability of monoliths enabled chromatographic separations at higher flow rates, which shortened analysis time to about one third. For the analysis of insulin in human biofluid samples, enhanced sensitivity was achieved by using a 50 microm I.D. ROMP-derived monolith.  相似文献   

4.
A continuous gradient elution method for capillary column (less than 0.32 mm I.D.) liquid chromatography was developed. Gradient eluent from a microbore liquid chromatograph was split ahead of the injector so that an accurate percentage (2-3%) of the mobile phase delivered by the pump flowed through the capillary column. The outlet of the column was connected to a length of 0.075 mm I.D. fused-silica capillary tubing which, in turn, was connected to a 6-mm optical path length longitudinal capillary flow cell. Fused-silica capillary columns of 0.32 mm I.D. were slurry-packed efficiently with 7-microns spherical, 300 A pore size, C8 bonded-phase particles, and evaluated in terms of their ability to resolve mixtures of proteins, peptides or phenylthiohydantoin (PTH)-amino acid derivatives. The gradient elution profiles agreed with those obtained using microbore (less than 2.1 mm I.D.) and larger bore columns. The minimum detectable amounts for proteins and PTH-amino acids on 0.32 mm I.D. capillary columns were 50 pg and 25 fmol, respectively. At a flow-rate of 3.6 microliters/min, proteins and peptides were recovered from the capillary columns in volumes of about 2-8 microliters. The use of a multiple-wavelength, forward-optics detector for identifying tryptophan- and tyrosine-containing peptides is discussed.  相似文献   

5.
Monolithic capillary columns were prepared by thermally initiated free radical polymerisation of phenyl acrylate (PA) and 1,4-phenylene diacrylate (PDA) in the confines of 200 microm I.D. fused silica capillaries. Polymerisation was performed in the presence of 2-propanol and tetrahydrofuran (THF) as inert diluents (porogens), using alpha,alpha'-azoisobutyronitrile (AIBN) as initiator. Morphology and porosity of the resulting monoliths were comprehensively studied by scanning electron microscopy (SEM), mercury intrusion porosimetry and inverse size-exclusion chromatography (ISEC). The novel poly(phenyl acrylate-co-1,4-phenylene diacrylate) (PA/PDA) monoliths showed high mechanical stability and were successfully applied to the separation of proteins and oligodeoxynucleotides, employing reversed-phase (RP) and ion-pair reversed-phase (IP-RP) conditions, respectively. Maximum loading capacities for cytochrome c and d(pT)(16) were evaluated and found to be in the region of 200 fmol. Batch-to-batch reproducibility was determined for three independently prepared PA/PDA monolithic capillary columns. Relative standard deviations (RSDs) of retention time (t(R)) of 0.7-1.6% for proteins and 0.2-2.5% for d(pT)(12-18) proved high reproducibility of the PA/PDA supports.  相似文献   

6.
Monolithic columns of 2.7 mm I.D. have been prepared and used in electrochromatography (EC) separation. Although capillary electrochromatography (CEC) has higher separation efficiency, it displays some shortcomings, such as limited sample loadability and restricted concentration detectability etc. In this paper, we investigate the feasibility of EC separation with millimeter diameter monolithic columns. By using a designed preparation method of monolithic column packed with about 150 microm quartz sand, the effect of Joule heating can be reduced, and the processes of frit making and column packing can be avoided. The concentration detectability of the EC is improved comparing with that of CEC. Moreover, the separation efficiency of 52,000 plates/m was achieved with a 70 mm length and 2.7 mm I.D. monolithic column.  相似文献   

7.
Various buffers (ammonium acetate, ammonium formate, and ammonium hydrogencarbonate), acids (formic acid, acetic acid, heptafluorobutyric acid, and trifluoroacetic acid), and bases (ammonium hydroxide and morpholine) covering the range from 2 to 11.5 have been investigated for their performance in the separation of proteins by reversed-phase liquid chromatography (RPLC) and in their detection by electrospray mass spectrometry (ESI-MS). These additives were first tested for the detection of standard proteins by ESI-MS by flow-injection analysis (FIA). Those additives yielding the highest signals were employed for the separation of standard proteins by using three different reversed-phase columns: two C18 columns (4.6 mm I.D. and 2.1 mm I.D.) and one perfusion column (2 mm I.D.). The sensitivity of the LC-MS system was evaluated with the column giving the best results and with those LC eluents enabling the LC separation of the proteins and also yielding the highest MS signals. For that purpose, calibration curves were compared for both LC-MS and FIA-MS. Formic acid was the additive yielding the highest responses in FIA-MS and trifluoroacetic acid (TFA) gave the best separation and recovery of the proteins. However, problems related to poor recovery of the proteins in the column when formic acid was used and the significant signal suppression observed in MS when TFA was employed, made neither of them suitable for the sensitive detection of the proteins in LC-MS.  相似文献   

8.
The combination of narrow-bore capillary gas chromatography with bench-top quadrupole mass spectrometric detection was evaluated for the determination of polychlorinated biphenyls (PCBs). The qualitative and quantitative performances of the system are illustrated by several analyses (PCB standards and human milk extracts). Capillary columns with different internal diameters (0.10, 0.18 and 0.22 mm, respectively) were compared for their ability to separate PCB congeners and the analysis time. Short run times (less than 7 min) were sufficient for complete separation of PCB congeners on a 0.10-mm internal diameter (I.D.) capillary column without any loss of resolution when compared with a 0.22 mm I.D. column. Good qualitative and quantitative data acquisition was possible with quadrupole mass spectrometer for run times of 8 min, but incomplete peak reading was observed when run times were reduced to 3-4 min. Selected ion monitoring and dwell times of 10 ms are necessary to obtain detection limits for individual PCB congeners as low as 0.4 pg microl(-1) for standard solutions and 0.2 ng g(-1) fat for milk extracts. By using cold splitless injection, relatively high volumes (1 microl) for narrow-bore capillaries could be injected without any peak distortion.  相似文献   

9.
Reversed-phase high-performance liquid chromatography with microbore columns (50 X 1.0 mm) was used effectively for the separation and analysis of proteins down to 1 ng at flow-rates of 0.1-0.2 ml/min. With the use of standard low-pressure gradient HPLC equipment, the peak volumes were five times smaller when compared with a conventional column at equal chromatographic efficiencies and analysis time. The sensitivity of detection was further increased by a reduction in solvent peaks, resulting in a 20-fold overall increase.  相似文献   

10.
Fused-silica capillary columns (100 μm I.D.) englobing a porous monolithic stationary phase were prepared by in situ copolymerization of 2-ethylhexyl methacrylate, ethylene glycol dimethacrylate and 2-acrylamido-2-methylpropanesulfonic acid (AMPS) in the presence of a porogenic mixture containing 1-propanol, 1,4 butanediol and water. The influence of the monomers ratio and the porogen solvent composition as well as the content of AMPS in the polymerization mixture on column total porosity and efficiency was investigated to attain minimum HETP values for the reversed-phase capillary electrochromatography separation of bioflavonoids. For the most promising column, the van Deemter plots, in both μ-HPLC and CEC, were also evaluated. In CEC the reduced plate height was found almost constant (1.6–2.0) within the range of linear mobile phase velocity between 0.2–2.0 mm s−1. The chemical and mechanical stabilities of the monolithic column over a wide range of buffer pH (2-10) and time were satisfactory. Furthermore, the effects of mobile phase parameters, such as buffer concentration and organic modifier content, on the electroosmotic flow were studied systematically. CEC separations of standard mixtures of polyphenols, including flavonols, flavanones and flavanones-7-O-glycosides, were accomplished in less than 8 min. The CEC separation of the major flavanone glycoside constituents in the extract from a freshly squeezed grapefruit juice was also reported.  相似文献   

11.
王玉红  刘芳  赵卉  王建民  王彦  阎超 《分析化学》2012,40(10):1622-1626
构建了适用于纳升级到微升级流量的毛细管分离体系的微流蒸发光散射检测器(μELSD),实现了其与毛细管液相色谱(eLC)的联用.对雾化器孔径和雾化毛细管内径、蒸发管内径和长度、光散射池尺寸、雾化毛细管位置和辅助载气流量等参数进行了优化.在最优条件下,微流蒸发光散射检测器检出限为直接进样葡萄糖1 ng(S/N> 10),线性范围0.01~1.0 μg,重复性好,峰面积RSD(n=6)为0.4%,峰高RSD(n=6)为0.3%.本检测器已成功应用cLC-μELSD平台,使用C18毛细管色谱柱(内径250 μm),0.1%甲酸铵溶液(pH 4.5)-甲醇(60∶40,V/V)为流动相,分离检测了3种常用甜味剂,表明本研究构建的系统可以应用于实际分离检测中,具有分析时间快、溶剂消耗量少、样品需求量小的优点.  相似文献   

12.
Monolithic capillary columns (320 microm I.D.) were prepared for capillary liquid chromatography (CLC) by radical polymerization of butylmethacrylate (BMA) and ethylenedimethacrylate (EDMA) in the presence of a porogen solvent containing propan-1-ol, butane-1,4-diol and water. The influence of the contents of the porogen solvent and EDMA in the polymerization mixture on the monolith porosity and column efficiency was investigated. The composition of the polymerization mixture was optimized to attain a minimum HETP of the order of tens of microm for test compounds with various polarities. The separation performance and selectivity of the most efficient monolithic column prepared was characterized by van Deemter curves, peak asymmetry factors and Walters hydrophobicity and silanol indices. It was demonstrated that the 320-microm I.D. monolithic column exhibited CLC separation performance similar to that observed for 100- and 150-microm I.D. monolithic columns reported in the literature; moreover, the 320-microm I.D. column was easier to operate in CLC and exhibited a higher sample loadability.  相似文献   

13.
Reduction of through-pore size and skeleton size of a monolithic silica column was attempted to provide high separation efficiency in a short time. Monolithic silica columns were prepared to have various sizes of skeletons (approximately 1-2 microm) and through-pores (approximately 2-8 microm) in a fused-silica capillary (50-200 microm I.D.). The columns were evaluated in HPLC after derivatization to C18 phase. It was possible to prepare monolithic silica structures in capillaries of up to 200 microm I.D. from a mixture of tetramethoxysilane and methyltrimethoxysilane. As expected, a monolithic silica column with smaller domain size showed higher column efficiency and higher pressure drop. High external porosity (> 80%) and large through-pores resulted in high permeability (K = 8 x 10(-14) -1.3 x 10(-12) m2) that was 2-30 times higher than that of a column packed with 5-mirom silica particles. The monolithic silica columns prepared in capillaries produced a plate height of about 8-12 microm with an 80% aqueous acetonitrile mobile phase at a linear velocity of 1 mm/s. Separation impedance, E, was found to be as low as 100 under optimum conditions, a value about an order of magnitude lower than reported for conventional columns packed with 5-microm particles. Although a column with smaller domain size generally resulted in higher separation impedance and the lower total performance, the monolithic silica columns showed performance beyond the limit of conventional particle-packed columns under pressure-driven conditions.  相似文献   

14.
Novel monolithic capillary HPLC columns were prepared via ring opening metathesis polymerization (ROMP) within the confines of fused silica columns with 200 microm i.d. using norborn-2-ene (NBE), 1,4,4a,5,8,8a-hexahydro-1,4,5,8, exo, endo-dimethanonaphthalene (DMN-H6) as monomers, 2-propanol and toluene as porogens and RuCl2(PCy3)2(CHPh) as initiator. Using the monolithic capillary HPLC columns, different sets of analytes (i.e. standard systems) were used for the evaluation of the monolithic columns: (i) a protein standard consisting of six proteins in the range of 5000-66 000 g/mol, (ii) an insulin-albumin standard, and (iii) a peptide standard obtained from a tryptic digest of cytochrome C. With these three different standard systems the reproducibility of synthesis in terms of separation performance proved to be 1-2% relative standard deviation in tR. Variation of polymerization parameters had a significant influence on the monolithic morphology and therefore separation efficiency and back pressure. The maximum analytical loading capacity of ROMP-derived monolithic capillary columns for albumin was found to be 30-125 ng, depending on the monomer content. Long-term stability studies showed no alteration in separation performance.  相似文献   

15.
Monolithic columns based on poly-(styrene-divinylbenzene) (PS-DVB) were utilized both for preconcentration (in 10 mm x 0.20 mm I.D. format) and analytical separation (in 60 mm x 0.20 and 0.10 mm I.D. format) of peptides and proteins in column switching micro-scale high-performance liquid chromatography. A special holder for short monolithic preconcentration columns was designed and pressure durability tests approved long-term stability up to 400 bar. An 11-20% decrease in the average peak widths of nine peptides was obtained upon combining a preconcentration column with an analytical column as compared with a setup using an analytical column only. Trapping efficiency, especially for small and hydrophilic peptides, was optimized by using 0.10% heptafluorobutyric acid instead of 0.050% trifluoroacetic acid as solvent additive during sample loading. Using a 10 mm x 0.20 mm I.D. preconcentration column, loadabilities between 0.5 and 1.6 microg were determined by frontal analysis of proteins and bioactive peptides, respectively. A 100-fold concentration followed by direct on-line intact mass determination is demonstrated for diluted (3 micromolL(-1)) protein solutions. The applicability of the monolithic preconcentration column for multidimensional chromatography was tested by off-line two-dimensional separation, combining strong cation-exchange chromatography and ion-pair reversed-phase chromatography. Peptide identification data from digested protein mixtures demonstrated reproducibilities of 46-75% in triplicate analyses, and confident peptide identifications of low abundant peptides even in the presence of a 650-fold molar excess of high abundant peptides.  相似文献   

16.
台锥形柱尾的填充毛细管液相色谱柱   总被引:3,自引:0,他引:3  
朱翠茹  关亚风  王涵文  朱道乾 《分析化学》2000,28(10):1204-1208
首次将台锥形柱尾用于填充毛细管液相色谱柱,并与环氧胶粘的柱尾连接方式进行比较,发现在柱内径≥0.32mm时,前者的柱效比后者高出30%~50%,且明显改善柱效-流速特性。对比研究了不同内径柱(0.53mm,0.32mm,0.25mm)采用两种尾接方式的塔板高度与流速的关系,对产生差异的原因进行了探讨。  相似文献   

17.
The ability and efficiency of micro precolumns made of C30 particles, monolithic silica C18 stationary phase and quartz wool coated with C30, which act as novel solid phase absorbing materials, for the on-line enrichment of aqueous polycyclic aromatic hydrocarbons (PAHs) in microcolumn liquid chromatography (LC) was investigated. The enrichment unit was designed in such a way that micro precolumns were directly connected to a 6-port micro injection valve via fused-silica tubing (0.05 mm I.D.) in order to minimize band broadening of the samples, and the enrichment efficiency of the three materials was tested using 14 PAHs, which are selected by the US Environmental Protection Agency (US EPA), as the analytes. The separation of PAHs was evaluated by using laboratory-made C30 or ODS capillary columns and the results were compared. There were no significant differences showed from the separation of PAHs in terms of peak signal between the C30 and ODS capillary columns, but the C30 capillary column was chosen for the following experiment due to its ability to produce better repeatability than the ODS column. By using the three kinds of precolumn materials, results showed that the precolumn packed with C30 particles as well as the capillary monolithic C18 precolumns (0.1 or 0.2 mm I.D.) provided better recovery than those of the quartz wool's. As long as the recovery and separation of the PAHs were concerned, 0.1 mm I.D. monolithic C18 precolumn showed the best results and the R.S.D.s (N = 7) for the retention time, peak area and peak height were between 0.70-1.5, 2.3-5.8 and 2.4-6.6%, respectively. Large volume injection up to 0.5 mL, i.e. 2500-fold enrichment, was possible and no negative effect on the separation profile was found. The LOD (S/N = 3) were between 0.10 and 4.6 pg mL−1, while the LOQ (S/N = 10) were in the range of 0.32-15 pg mL−1, which showed that the system is comparable to many major analytical techniques and is sensitive enough for the trace analysis of PAHs in environmental samples. The system was then applied to the determination of trace PAHs present in soil sample which was randomly taken from a nearby highway.  相似文献   

18.
Continuous-bed columns containing sol-gel bonded 3 microm silica particles with mixed-mode octadecyl and propylsulfonic acid functional groups (ODS/SCX) were prepared by first packing the ODS/SCX particles into a fused-silica capillary, then filling the packed capillary with a siliceous sol-gel, curing the sol-gel, and finally drying the column with supercritical carbon dioxide. The performance of the sol-gel bonded ODS/SCX columns was evaluated for capillary electrochromatography using acetonitrile aqueous mobile phase containing phosphate buffer. The columns were mechanically strong and permeable. Both EOF velocity and current increased linearly with elevation of the applied electric field strength. The EOF velocity was high at low pH and nearly constant over a range of pH 2-9. Higher buffer concentration resulted in higher current and lower EOF velocity. The acetonitrile content had no significant effect on the EOF. Without thermosetting the column, no bubble formation was noticed with currents up to 2.5 microA. The minimum plate height of a 25/34 cm x 75 microm I.D. sol-gel bonded 3 microm ODS/SCX column was 5.7 microm (1.75 x 10(5) plates per meter) at an optimum EOF velocity of 0.92 mm s(-1). Mixtures of test aromatic compounds and aromatic hydrocarbon homologues gave symmetrical peaks when using a low pH mobile phase. The retention and elution order of aromatic compounds represented a typical reversed-phase separation mechanism similar to conventional ODS columns. The run-to-run and column-to-column retention factor reproducibility was better than 2.5% and 8.0% RSD, respectively.  相似文献   

19.
In the present work, an orthogonal two-dimensional (2D) capillary liquid chromatography (LC) method for fractionation and separation of proteins using wide range pH gradient ion exchange chromatography (IEC) in the first dimension and reversed phase (RP) in the second dimension, is demonstrated. In the first dimension a strong anion exchange (SAX) column subjected to a wide range (10.5-3.5) descending pH gradient was employed, while in the second dimension, a large pore (4,000 A) polystyrene-divinylbenzene (PS-DVB) RP analytical column was used for separation of the protein pH-fractions from the first dimension. The separation power of the off-line 2D method was demonstrated by fractionation and separation of human plasma proteins. Seventeen pH-fractions were manually collected and immediately separated in the second dimension using a column switching capillary RP-LC system. Totally, more than 200 protein peaks were observed in the RP chromatograms of the pH-fractions. On-line 2D analysis was performed for fractionation and separation of ten standard proteins. Two pH-fractions (basic and acidic) from the first dimension were trapped on PS-DVB RP trap columns prior to back-flushed elution onto the analytical RP column for fast separation of the proteins with UV/MS detection.  相似文献   

20.
Monolithic silica columns of 2.7 mm ID were prepared and derivatized with C8-TEOS and TEOS by on-column sol-gel reaction. These C8 large diameter monolithic silica columns gave 21 000 theoretical plates for aromatic hydrocarbons in 60% acetonitrile and 40% Tris-HCI buffer. The surface areas as well as the separation reproducibility were improved on coating by the sol-gel approach. Joule heating was greatly reduced by using monolithic columns to which fine quartz sand had been added during column preparation. Since this is a preliminary investigation on a monolithic column with such a large inner diameter, the separation efficiency was not so high as that presently achieved in normal capillary electrochromatography (CEC). However, use of the columns improved sample loadability and concentration detectability of electrochromatography, and semi-preparative separations could be performed.  相似文献   