首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Nanometer-sized l-cysteine-capped ZnS particles have been synthesized and used as a fluorescence probe to investigate the effect of proteins on fluorescent intensity. With =190 nm, maximum and constant synchronous fluorescence enhancement was produced at 267 nm and pH 5.12 in the presence of proteins. A highly sensitive synchronous fluorescence method for the rapid determination of proteins has been developed. Under optimum conditions, calibration graphs are linear over the range 0.03–8.0 g mL–1 for bovine serum albumin (BSA), 0.01–6.0 g mL–1 for human serum albumin (HSA), 0.05–8.0 g mL–1 for -globulin (-G), and 0.04–4.0 g mL–1 for ovalbumin, respectively. The relative standard deviations of seven replicate measurements were 1.75% for 1.0 g mL–1 BSA, 1.90% for 1.0 g mL–1 HSA, 1.65% for 1.0 g mL–1 -G, and 2.32% for 1.0 g mL–1 ovalbumin.  相似文献   

2.
Summary A rapid and accurate LC method is described for simultaneous determination of pseudoephedrine hydrochloride (PSE), acetaminophen (AMP), dextromethorphen hydrobromide (DEX), and diphenhydramine hydrochloride (DPH) in a compound formulation. Chromatographic separation of the four drugs was achieved on a Hypersil CN column (150 mm × 4.6 mm, 5 m particle) by use of a mobile phase comprising a mixture of 3 mM ion-pairing solution, 2% aqueous triethylamine solution, and 2 M phosphoric acid, 68:48:88 (v/v), pH 3.0, delivered at 1.0 mL min–1. Compounds were detected at 215 nm and the run time was less than 10 min. The linearity, accuracy, and precision of the method were found to be acceptable over the concentration ranges 6.1–36.4 g mL–1 for PSE, 65.0–390.0 g mL–1 for AMP, 3.1–18.6 g mL–1 for DEX, and 5.0–30.0 g mL–1 for DPH.  相似文献   

3.
The aim of the present study was to develop a sensitive method to measure dextromethorphan and dextrorphan in urine by HPLC to support pharmacogenetic studies in ethnic groups. Linearity was assessed in the range: 0.015–10 g mL–1 for dextromethorphan and 1-10 g mL–1 for dextrorphan. Inter and intra-day coefficients of variation were < 10%. Limits of detection and quantitation were 0.003 g mL–1 and 0.015 g mL–1 for dextromethorphan and 0.24 g mL–1 and 1.0 g mL–1 for dextrorphan, respectively. The method is reliable in helping determine the phenotype of Mexican ethnic groups using model drugs such as dextromethorphan.  相似文献   

4.
A fast and simple micellar electrokinetic capillary chromatographic method was developed for the analysis of piribedil in pharmaceutical formulations. The effects of buffer concentration, buffer pH, sodium dodecyl sulphate (SDS) concentration, organic modifier, applied voltage and injection time were investigated. Optimum results were obtained with a 50 mM borate buffer at pH 8.0 containing 50 mM SDS by using a fused silica capillary (50 m internal diameter, 72 cm effective length). The sample was injected hydrodynamically for 4 s at 50 mbar pressure and the applied voltage was +30 kV. The detection wavelength was set at 205 nm. Diflunisal was used as an internal standard. The analysis was performed at 25 °C and the total run time was 14 min. The method was suitably validated with respect to linearity range, limit of detection and quantification, precision, accuracy, specificity and robustness. The linear calibration range was 5–100 g mL–1 and the limit of detection was determined as 1 g mL–1. The method developed was successfully applied to the determination of piribedil in pharmaceutical formulations. The results were compared with a spectrophotometric method reported in the literature and no significant difference was found statistically.  相似文献   

5.
A rapid and accurate HPLC method has been developed for simultaneous determination of pioglitazone and glimepiride. Chromatographic separation of the two pharmaceuticals was performed on a Cosmosil C18 column (150 mm × 4.6 mm, 5 m) with a 45:35:20 (v/v) mixture of 0.01 m triammonium citrate (pH adjusted to 6.95 with orthophosphoric acid), acetonitrile, and methanol as mobile phase, at a flow rate of 1.0 mL min–1, and detection at 228 nm. Separation was complete in less than 10 min. The method was validated for linearity, accuracy, precision, limit of quantitation, and robustness [1, 2]. Linearity, accuracy, and precision were found to be acceptable over the ranges 2.50–30.00 g mL–1 for pioglitazone and 0.10–10.00 g mL–1 for glimepiride.  相似文献   

6.
A novel method, capillary electrophoresis with amperometric detection, has been established for rapid and effective measurement of levodopa (L-dopa), and benserazide (BS) and its impurity (R,S)-2-amino-3-hydroxypropanohydrazide (Ro-04-1419) in co-beneldopa pharmaceutical formulations. Suitable separation and amperometric detection conditions were investigated and optimized. The optimum conditions of CZE detection were 40 mm phosphate solution at pH 5.3 as running buffer, 17 kV separation voltage, carbon-disk working electrode, 0.95 V (relative to Ag/AgCl) as detection potential, and sample injection for 8 s at 17 kV. The linear ranges were from 1.25 to 50 g mL–1 for L-dopa, 1.2 × 10–1 to 25.5 g mL–1 for BS, and 1.0 × 10–2 to 4.4 × 10–1 g mL–1 for Ro-04-1419, with correlation coefficients of 0.9994, 0.9951, and 0.9933, respectively. The detection limits for L-dopa, BS, and Ro-04-1419 were 0.38, 0.02, and 0.004 g mL–1, respectively. Average recoveries were 100.2% for L-dopa, 102.4% for BS, and 90.8% for Ro-04-1419. This method was successfully applied to co-beneldopa granules and tablets.Revised: 30 November and 22 December 2004  相似文献   

7.
Summary A gas chromatographic methodology with selective detection is presented for the analysis in wines and corks of pentachlorophenol residues, which are suspected to be the most likely precursors of some off-flavours described in several wine samples. After derivatisation, pentachlorophenol acetate residues were monitored by electrolytic conductivity detection and/or mass spectrometric detection in the selective ion mode at m/z 264 and 266. Recoveries varied from 80 to 96% for wine samples fortified with 5 to 100 g l–1 and from 83 to 91% for corks (fortified at 25 to 100 g kg–1). The proposed methodology allowed for a determination limit of g l–1 for wine and 10 g kg–1 for corks.  相似文献   

8.
A micellar electrokinetic capillary chromatography (MECC) method was developed for the qualitative and quantitative determination of five marker compounds (iridoid glycosides, flavonoids and phenylethanoids) in Verbena officinalis. Optimum separation was achieved using a 50 mM sodium borate solution (pH 9.3), containing 50 mM sodium dodecylsulfate (SDS) as surfactant, at an applied voltage of 25 kV and a temperature of 30 °C, respectively. Because of their different absorption maxima, the compounds were detected either at 205 or 235 nm. Calibration data confirmed linearity of the detector response within the concentration range injected (R2 from 0.997 to 0.999), and revealed detection limits ranging from 5.0 g mL–1 (verbascoside) to 13.6 g mL–1 (hastatoside). The five markers were readily assignable in several samples of Verbena.  相似文献   

9.
Summary A simple, specific, and sensitive high-performance liquid chromatography method has been developed for simultaneous determination of the lomefloxacin, febufen, and felbinac in human plasma. Plasma-spiked with internal standard, was vortex-mixed for 1 min with a mixture of dichloromethane-diethylether (80:20, v/v). The evaporated extract was dissolved in 0.02 M NaOH. The extracts were chromatographed on an Supelcosil LCSAX column (5 m 250×4.6 mm I.D.) equipped with a guard column with a mibile phase composed of acetonitrile and phosphate buffer, with ultraviolet detection. Drugs were resolved at ambient temperature on a flow rate was 1.2 mL min–1, and monitoring was performed at 280 nm. The detection limits for lomefloxacin was 0.05 g mL–1, 0.02 g mL–1 for fenbufen and 0.03 g mL–1 for felbinac. No interference from other commonly administered drugs or endogenous substances was observed. The method is fast since it involves two extraction steps followed by evaporation of organic solvent and chromatography of the residue. This method was found to be applicable to pharmacokinetic and pharmacodynamic studies of each drug after the concomitant administration of lomefloxacin and febufen.  相似文献   

10.
A novel method for the direct determination of the aminoglycoside tobramycin was developed and validated based on reversed-phase high-performance liquid chromatography (RP-HPLC) with evaporative light scattering detector (ELSD). Using a Waters ODS-2 C18 Spherisorb column with an evaporation temperature of 45°C and nitrogen pressure of 3.5 bar, the selected mobile phase consisted of water/acetonitrile 55:45 containing 1.5 mL L–1 HFBA (11.6 mM) in an isocratic mode at a rate of 1.0 mL min–1. Tobramycins retention time was 4.3 min with an asymmetry factor of 1.7. A logarithmic calibration curve was obtained from 1 to 38 g mL–1 (r > 0.9998). LOD was 0.3 g mL–1; within-day %RSD was 1.0 (n = 3, 4.7 g mL–1) and between-day %RSD was 1.1 (3 days within a week). The developed method was applied to the determination of tobramycin in a pharmaceutical crude substance and formulations (eye drops and ointments). Dilution experiments revealed the absence of interference from excipients (no constant and proportional errors); recovery from spiked samples was 99–103% with %RSD < 2.2 (n = 3×3). The developed HPLC/ELSD method was also found to be applicable in the determination of tobramycin in human plasma (0.6–12.5 g mL–1) and urine (1.5–12.5 g mL–1) after solid-phase extraction using carboxylate cartridges followed by solvent evaporation (×2 preconcentration). A mean recovery of 86% for plasma and 91% for urine was obtained.  相似文献   

11.
The determination of trace metals, e.g. Bi, Cd, Pb, in high-purity aluminium, zinc and commercial steel by flame or graphite furnace atomic absorption spectrometry following their preconcentrations as iodo complexes on XAD-1180 resin by means of a short column system is described. The recoveries are quantitative (95%). The relative standard deviations varies between 6% and 10%. The relative errors are less than 8% in a concentration range of 1 × 10–3 –4 × 10–5%. Detection limits for flame AAS and GFAAS were in the ranges of 0.002–0.110 g/ml and 0.0003–0.004 g/ml or in the ranges of 0.08–4.40 g/g and 0.012–0.16 g/g with respect to the solid samples, respectively.  相似文献   

12.
Summary Due to manifold physiological and cardioprotective actions of adenosine, the demand for a simple but accurate method to determine its concentration in plasma is increasing. The aim of this study was firstly to develop a simple isocratic method instead of the gradient elution or peak-shifting techniques used earlier and secondly to check conflicting data on the composition of stop-solution, added to the sample in order to prevent changes in adenosine concentration. Isocratic elution improved signal to noise ratio and concentrations of 100 mol L–1 dipyridamole and 2.5 mol L–1 erythro-9(2-hydroxy-3-nonyl)adenine in the blood sample effectively prevented both adenosine formation and degradation, even without the use of a 5-ecto-nucleotidase inhibitor. Lowering the concentration of dipyridamole to 25 mol L–1 caused more than a tenfold increase of adenosine concentration in two out of five cases and even 100 mol L–1 dipyridamole alone is not sufficient to inhibit adenosine deaminase in blood samples.  相似文献   

13.
An isocratic liquid chromatographic method for determination of acetaminophen (AMP), caffeine (CAF), chlorphenamine maleate (CPM) and guaiacol glyceryl ether (GGE) in a compound cold formulation is described. Separation and quantitation were achieved on a Diamonsil C18 column using a binary mixture of methanol and 1.5% aqueous acetic acid (55: 45, v/v, pH 3.6) as mobile phase delivered at 0.4 mL min–1. Single wavelength detection was at 220 nm for all four drugs and the run time was < 10 min. The linearity, accuracy and precision of the method were found to be acceptable over the concentration ranges: 16.0–127.8 g mL–1 for AMP, 6.0–48.2 g mL–1 for CAF, 5.0–40.0 g mL–1 for CPM and 10.1–80.6 g mL–1 for GGE.  相似文献   

14.
Zusammenfassung Eine neue Methode zur Durchführung gravimetrischer Bestimmungen im Mikrogrammbereich wurde beschrieben; diese beruht im wesentlichen darauf, daß der Niederschlag nicht mehr zusammen mit dem Filter, sondern nach Überführen mit einem geeigneten Lösungsmittel in einem separaten Wägegefäß gewogen wird.Die dazu nötigen Geräte und deren Herstellung wurden beschrieben. Nach dieser Methode wurden folgende Bestimmungen mit zufriedenstellender Richtigkeit durchgeführt: 2,5–25g Al, 5–50g Cu und 5–50g Zn mit Oxin, 2,5–25g Fe(III) und 2,5–25g Ti(IV) mit N-Benzoyl-phenylhydroxylamin, 5–50g Ni und 5–50g Cu mit Salicylaldoxim, 2,5–50g Co(II) und 2,5–50g Fe(III) mit -Nitroso--naphthol sowie 5–50g Chlorid als Silberchlorid.
Precipitation analysis in the microgram-scale: A new method
Summary A new method for gravimetric determinations in the microgram-scale is described. This method is based on the fact that the precipitate is not weighed together with the filter but is transferred to a separate weighingvessel using a suitable solvent. The necessary simple devices and their use are described. The following determinations were carried out with satisfying accuracy: 2,5–25g Al, 5–50g Cu and 5–50g Zn with Oxine, 2,5–25g Fe and 2,5–25g Ti withN-benzoylphenylhydroxylamine, 5–50g Ni and 5–50g Cu with salicylaldoxime, 2,52–50g Co and 2,5–50g Fe with -nitroso--naphthol and 5–50g chloride as silver chloride.
  相似文献   

15.
Arsenic in sea water was determined directly by graphite furnace atomic absorption spectrometry (GFAAS) using palladium nitrate as chemical modifier, at an optimum concentration of 15 mg l–1. Deuterium and Zeeman effect background correction were compared and gave detection limits of 0.6 and 0.8 g l–1, respectively. Precisions between 8 and 2%, for both correctors, were obtained with an injection volume of 40 l. The accuracy obtained with different reference materials: CRM-403 (1.461 g kg–1), NASS-4 (1.26 ±0.09 gl–1) and IAEA/W-4 (24–31 g l–1) was studied for large injection volumes for both background correction systems. Interferences by chloride, sodium, potassium, calcium and silicon were removed by Zeeman correction, whereas deuterium correction was much less effective and was insufficiently accurate for sea water samples.  相似文献   

16.
The formation of nucleic acids/8-hydroxyquinoline/yttrium(III) ternary complexes and their fluorescent properties have been studied. The nucleic acids studied include native and thermally denatured calf thymus DNA, fish sperm DNA and yeast RNA. In the range of pH 7.6–8.5, controlled by NH3-NH4C1 buffer, ternary complexes are formed that fluoresce at different wavelengths with different nucleic acids. Based on the fluorescence reactions, sensitive spectrofluorimetric methods for nucleic acids are proposed. In optimal conditions, the calibration curves were linear in the range 0.5–4.0 gml–1 for calf thymus DNA, 0.5–2.5 g ml–1 for fish sperm DNA and 0.5–4.0 g ml–1 for yeast RNA. The limits of determination (3 ) were 0.030 g ml–1 for calf thymus DNA, 0.020 g ml–1 for fish sperm DNA and 0.090 g ml–1 for yeast RNA. Corresponding to the interferences of coexisting substances, six synthetic samples were constructed and the results of determination were satisfactory.  相似文献   

17.
A method for the determination of aldrin, dieldrin, DDT, DDE, and DDD contamination in animal fats (beef tallow, lard, and chicken fat) without using toxic reagents is developed, that uses high-performance liquid chromatography after the sample has been prepared by matrix solid-phase dispersion (MSPD) with acidic alumina oxide. A reversed-phase C1-silica column with a mobile phase of 50% (v/v) ethanol solution (in water) and a photo-diode array detector were used for the determination. Average recoveries of the target compounds (0.2–5.0 g g–1) ranged from 84–98%, with coefficients of variation of <5%. The limits of quantitation were 0.16 g g–1 for AD, 0.10 g g–1 for DD, 0.06 g g–1 for DDT, 0.07 g g–1 for DDE, and 0.05 g g–1 for DDD. No toxic reagents were used at all.  相似文献   

18.
Pfeffer  M.  Walenciak-Reddel  E. 《Chromatographia》1994,38(7-8):479-484
Summary A high-performance liquid chromatographic method is discribed for the determination of 6-amino-2,2-dimethyl-1,3-dioxepan-5-ol using Spherisorb ODS II stationary phase and mobile phase 30:70 (v/v) methanol: aqueous 1-octane sulfonic acid. Detection was fluorimetric following postcolumn derivatization with o-phthaladehyde/2-mercaptoethanol. The procedure was applied to the analysis of aqueous solutions and microcrystalline suspensions in liquid paraffin, prepared for investigation of the toxicological profile. The method was validated for selectivity, linearity of detector response, repeatability, limit of detection and quantitation. The HPLC method was selective. The instrumental limit of detection was 0.5 ng per injection (0.05 g mL–1). The method detection limits were 0.5 g mL–1 aqueous solution and 5 g mL–1 liquid paraffin suspension, the quantitation limit 0.05 mg mL–1 aqueous solution and 1.0 mg mL–1 liquid paraffin. Linearity was within 0.94–47.1 g mL–1. Intra-assay accuracy accounted for 99–100% in the range 0.05–226 mg mL–1 aqueous solution, intra-assay precision for 2% (C.V.). For microcrystalline liquid paraffin suspensions with 1 and 250 mg mL–1 99 and 109% was found for intra-assay accuracy. Intra-assay precision was 5% (C.V.). Reliable results over a wide concentration range can be obtained. The procedure is considered valid for determination of the analyte in aqueous solution or microcrystalline paraffin oil suspensions.  相似文献   

19.
Summary A capillary gas chromatographic method for the determination of fosfomycin in human urine is described. After dilution of the sample and derivatization, analysis was on a HP-1 capillary column and a flame ionization detector was used to determine the bistrimethylsilyl derivative of fosfomycin. Response was linear in the range 50–5000 g mL–1. The detection limit was about 10 g mL–1. The within and between day coefficients of variation did not exceed 6%. The method was applied to the determination of fosfomycin in urine samples collected during clinical pharmacokinetic studies.  相似文献   

20.
Column preconcentration methods have been established for the spectrophotometric determination of trace nitrite with sulfanilic acid (SA) orp-aminoacetophenone (AAP) as the diazotizable aromatic amine andN, N-dimethylaniline (DMA) or 1-aminonaphthalene (AN) as the coupling agent, using differention-pairs co-precipitated with biphenyl. Nitrite ion reacts with SA in the pH range 2.0–3.0 and AAP in the pH range 1.7–3.0 in HCl medium to form water-soluble colourless diazonium cations. These cations are subsequently coupled with DMA in the pH range 3.7–6.1 for the SA-DMA system and AN in the pH range 1.7–2.3 for the AAP-AN system to be retained on microcrystalline biphenyl packed in a column. The solid mass is dissolved out from the column with 5 ml of DMF and the absorbance is measured by a spectrophotometer at 420 nm for the SA-DMA system and at 517 nm for the AAP-AN system. The calibration was linear over the concentration ranges 0.3–6.0 g of nitrite in 5 ml of DMF solution (i.e., 0.02–0.40 g/ml in the sample solution) for the SA-DMA system and 0.5–7.0 g of nitrite in 5 ml of DMF solution (i.e., 0.03–0.47 g/ml in the sample solution) for the AAP-AN system. The molar absorptivity and Sandell's sensitivity were respectively 2.63 × 104lmol–1cm–1 and 1.75 × 10–3 g cm–2 for SA-DMA and 3.28 × 104lmol–1 cm–1 and 1.40 × 10–3 g cm–2 for AAP-AN. The concentration factors were 4 and 16 for SA-DMA and AAP-AN, respectively. The detection limits were 0.0138 and 0.0175 g/ml NO2 for SA-DMA and AAP-AN, respectively. Seven replicate determinations of a solution containing 3.5 g of nitrite gave mean absorbances of 0.410 and 0.500 with relative standard deviations of 0.51 and 0.55% for SA-DMA and AAP-AN, respectively. Interference from various foreign ions has been studied and the methods have been applied to the determination of nitrite in environmental samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号