首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This paper describes the design, construction and implementation of a relatively large controlled‐atmosphere cell and furnace arrangement. The purpose of this equipment is to facilitate the in situ characterization of materials used in molten salt electrowinning cells, using high‐energy X‐ray scattering techniques such as synchrotron‐based energy‐dispersive X‐ray diffraction. The applicability of this equipment is demonstrated by quantitative measurements of the phase composition of a model inert anode material, which were taken during an in situ study of an operational Fray–Farthing–Chen Cambridge electrowinning cell, featuring molten CaCl2 as the electrolyte. The feasibility of adapting the cell design to investigate materials in other high‐temperature environments is also discussed.  相似文献   

2.
X‐ray magnetic circular dichroism (XMCD) is one of the most powerful tools for investigating the magnetic properties of different types of materials that display ferromagnetic behavior. Compared with other magnetic‐sensitive techniques, XMCD has the advantage of being element specific and is capable of separating the spin and magnetic moment contributions associated with each element in the sample. In samples involving, for example, buried atoms, clusters on surfaces or at interfaces, ultrathin films, nanoparticles and nanostructures, three experimental conditions must be present to perform state‐of‐the‐art XMCD measurements: high magnetic fields, low temperatures and an ultra‐high‐vacuum environment. This paper describes a new apparatus that can be easily installed at different X‐ray and UV beamlines at the Brazilian Synchrotron Light Laboratory (LNLS). The apparatus combines the three characteristics described above and different methods to measure the absorption signal. It also permits in situ sample preparation and transfer to another chamber for measurement by conventional surface science techniques such as low‐energy electron diffraction (LEED), reflection high‐energy electron diffraction (RHEED), X‐ray photoelectron spectroscopy (XPS) and X‐ray photoelectron diffraction (XPD). Examples are given of XMCD measurements performed with this set‐up on different materials.  相似文献   

3.
An X‐ray magnetic circular dichroism experiment under multiple extreme conditions, 2 ≤T≤ 300 K, H≤ 10 T and P≤ 50 GPa, has been achieved at SPring‐8 BL39XU. A combination of the high‐brilliant X‐ray beam and a helicity‐controlled technique enabled the dichroic signal to be recorded with high accuracy. The performance is shown by the outcome of pressure‐induced ferromagnetism in Mn3GaC and the pressure‐suppressed Co moment in ErCo2. Two technical developments, a tiny diamond anvil cell inserted into a superconducting magnet and in situ pressure calibration using 90° Bragg diffraction from a NaCl marker, are also presented. X‐ray magnetic spectroscopy under multiple extreme conditions is now opening a new approach to materials science.  相似文献   

4.
A new multi‐purpose operando electrochemical cell was designed, constructed and tested on the Swiss–Norwegian Beamlines BM01 and BM31 at the European Synchrotron Radiation Facility. Single‐crystal sapphire X‐ray windows provide a good signal‐to‐noise ratio, excellent electrochemical contact because of the constant pressure between the electrodes, and perfect electrochemical stability at high potentials due to the inert and non‐conductive nature of sapphire. Examination of the phase transformations in the Li1–xFe0.5Mn0.5PO4 positive electrode (cathode) material at C/2 and 10C charge and discharge rates, and a study of the valence state of the Ni cations in the Li1–xNi0.5Mn1.5O4 cathode material for Li‐ion batteries, revealed the applicability of this novel cell design to diffraction and spectroscopic investigations of high‐power/high‐voltage electrodes for metal‐ion batteries.  相似文献   

5.
When studying electro‐mechanical materials, observing the structural changes during the actuation process is necessary for gaining a complete picture of the structure–property relationship as certain mechanisms may be meta‐stable during actuation. In situ diffraction methods offer a powerful and direct means of quantifying the structural contributions to the macroscopic strain of these materials. Here, a sample cell is demonstrated capable of measuring the structural variations of electro‐mechanical materials under applied electric potentials up to 10 kV. The cell is designed for use with X‐ray scattering techniques in reflection geometry, while simultaneously collecting macroscopic strain data using a linear displacement sensor. The results show that the macroscopic strain measured using the cell can be directly correlated with the microscopic response of the material obtained from diffraction data. The capabilities of the cell have been successfully demonstrated at the Powder Diffraction beamline of the Australian Synchrotron and the potential implementation of this cell with laboratory X‐ray diffraction instrumentation is also discussed.  相似文献   

6.
GAPD, a graphics‐processing‐unit (GPU)‐accelerated atom‐based polychromatic diffraction simulation code for direct, kinematics‐based, simulations of X‐ray/electron diffraction of large‐scale atomic systems with mono‐/polychromatic beams and arbitrary plane detector geometries, is presented. This code implements GPU parallel computation via both real‐ and reciprocal‐space decompositions. With GAPD, direct simulations are performed of the reciprocal lattice node of ultralarge systems (~5 billion atoms) and diffraction patterns of single‐crystal and polycrystalline configurations with mono‐ and polychromatic X‐ray beams (including synchrotron undulator sources), and validation, benchmark and application cases are presented.  相似文献   

7.
The applications of nuclear resonant scattering in laser‐heated diamond anvil cells have provided an important probe for the magnetic and vibrational properties of 57Fe‐bearing materials under high pressure and high temperature. Synchrotron X‐ray diffraction is one of the most powerful tools for studying phase stability and equation of state over a wide range of pressure and temperature conditions. Recently an experimental capability has been developed for simultaneous nuclear resonant scattering and X‐ray diffraction measurements using synchrotron radiation. Here the application of this method to determine the sound velocities of compressed Fe3C is shown. The X‐ray diffraction measurements allow detection of microscale impurities, phase transitions and chemical reactions upon compression or heating. They also provide information on sample pressure, grain size distribution and unit cell volume. By combining the Debye velocity extracted from the nuclear resonant inelastic X‐ray scattering measurements and the structure, density and elasticity data from the X‐ray diffraction measurements simultaneously obtained, more accurate sound velocity data can be derived. Our results on few‐crystal and powder samples indicate strong anisotropy in the sound velocities of Fe3C under ambient conditions.  相似文献   

8.
The crystal and local atomic structure of monoclinic ReO2 (α‐ReO2) under hydrostatic pressure up to 1.2 GPa was investigated for the first time using both X‐ray absorption spectroscopy and high‐resolution synchrotron X‐ray powder diffraction and a home‐built B4C anvil pressure cell developed for this purpose. Extended X‐ray absorption fine‐structure (EXAFS) data analysis at pressures from ambient up to 1.2 GPa indicates that there are two distinct Re—Re distances and a distorted ReO6 octahedron in the α‐ReO2 structure. X‐ray diffraction analysis at ambient pressure revealed an unambiguous solution for the crystal structure of the α‐phase, demonstrating a modulation of the Re—Re distances. The relatively small portion of the diffraction pattern accessed in the pressure‐dependent measurements does not allow for a detailed study of the crystal structure of α‐ReO2 under pressure. Nonetheless, a shift and reduction in the (011) Bragg peak intensity between 0.4 and 1.2 GPa is observed, with correlation to a decrease in Re—Re distance modulation, as confirmed by EXAFS analysis in the same pressure range. This behavior reveals that α‐ReO2 is a possible inner pressure gauge for future experiments up to 1.2 GPa.  相似文献   

9.
Combined small‐ and wide‐angle X‐ray scattering (SAXS/WAXS) is a powerful technique for the study of materials at length scales ranging from atomic/molecular sizes (a few angstroms) to the mesoscopic regime (~1 nm to ~1 µm). A set‐up to apply this technique at high X‐ray energies (E > 50 keV) has been developed. Hard X‐rays permit the execution of at least three classes of investigations that are significantly more difficult to perform at standard X‐ray energies (8–20 keV): (i) in situ strain analysis revealing anisotropic strain behaviour both at the atomic (WAXS) as well as at the mesoscopic (SAXS) length scales, (ii) acquisition of WAXS patterns to very large q (>20 Å?1) thus allowing atomic pair distribution function analysis (SAXS/PDF) of micro‐ and nano‐structured materials, and (iii) utilization of complex sample environments involving thick X‐ray windows and/or samples that can be penetrated only by high‐energy X‐rays. Using the reported set‐up a time resolution of approximately two seconds was demonstrated. It is planned to further improve this time resolution in the near future.  相似文献   

10.
Hydrothermal formation of tobermorite from a pre‐cured cake has been investigated by transmission X‐ray diffraction (XRD) using high‐energy X‐rays from a synchrotron radiation source in combination with a newly designed autoclave cell. The autoclave cell has a large and thin beryllium window for wide‐angle X‐ray diffraction; nevertheless, it withstands a steam pressure of more than 1.2 MPa, which enables in situ XRD measurements in a temperature range of 373 to 463 K under a saturated steam pressure. Formation and/or decomposition of several components has been successfully observed during 7.5 h of reaction time. From the intensity changes of the intermediate materials, namely non‐crystalline C–S–H and hydroxylellestadite, two pathways for tobermorite formation have been confirmed. Thus, the newly developed autoclave cell can be used for the analyses of reaction mechanisms under specific atmospheres and temperatures.  相似文献   

11.
The X‐ray mass attenuation coefficients of silver were measured in the energy range 5–20 keV with an accuracy of 0.01–0.2% on a relative scale down to 5.3 keV, and of 0.09–1.22% on an absolute scale to 5.0 keV. This analysis confirms that with careful choice of foil thickness and careful correction for systematics, especially including harmonic contents at lower energies, the X‐ray attenuation of high‐Z elements can be measured with high accuracy even at low X‐ray energies (<6 keV). This is the first high‐accuracy measurement of X‐ray mass attenuation coefficients of silver in the low energy range, indicating the possibility of obtaining high‐accuracy X‐ray absorption fine structure down to the L1 edge (3.8 keV) of silver. Comparison of results reported here with an earlier data set optimized for higher energies confirms accuracy to within one standard error of each data set collected and analysed using the principles of the X‐ray extended‐range technique (XERT). Comparison with theory shows a slow divergence towards lower energies in this region away from absorption edges. The methodology developed can be used for the XAFS analysis of compounds and solutions to investigate structural features, bonding and coordination chemistry.  相似文献   

12.
A new data collection strategy for performing synchrotron energy‐dispersive X‐ray diffraction computed tomography has been devised. This method is analogous to angle‐dispersive X‐ray diffraction whose diffraction signal originates from a line formed by intersection of the incident X‐ray beam and the sample. Energy resolution is preserved by using a collimator which defines a small sampling voxel. This voxel is translated in a series of parallel straight lines covering the whole sample and the operation is repeated at different rotation angles, thus generating one diffraction pattern per translation and rotation step. The method has been tested by imaging a specially designed phantom object, devised to be a demanding validator for X‐ray diffraction imaging. The relative strengths and weaknesses of the method have been analysed with respect to the classic angle‐dispersive technique. The reconstruction accuracy of the method is good, although an absorption correction is required for lower energy diffraction because of the large path lengths involved. The spatial resolution is only limited to the width of the scanning beam owing to the novel collection strategy. The current temporal resolution is poor, with a scan taking several hours. The method is best suited to studying large objects (e.g. for engineering and materials science applications) because it does not suffer from diffraction peak broadening effects irrespective of the sample size, in contrast to the angle‐dispersive case.  相似文献   

13.
The use of in situ time‐resolved dispersive X‐ray absorption spectroscopy (DXAS) to monitor the formation of Cu2(OH)3Cl particles in an aqueous solution is reported. The measurements were performed using a dedicated reaction cell, which enabled the evolution of the Cu K‐edge X‐ray absorption near‐edge spectroscopy to be followed during mild chemical synthesis. The formed Cu2(OH)3Cl particles were also characterized by synchrotron‐radiation‐excited X‐ray photoelectron spectroscopy, X‐ray diffraction and scanning electron microscopy. The influence of polyvinylpyrrolidone (PVP) on the electronic and structural properties of the formed particles was investigated. The results indicate clearly the formation of Cu2(OH)3Cl, with or without the use of PVP, which presents very similar crystalline structures in the long‐range order. However, depending on the reaction, dramatic differences were observed by in situ DXAS in the vicinities of the Cu atoms.  相似文献   

14.
A new system of slits called `spiderweb slits' have been developed for depth‐resolved powder or polycrystalline X‐ray diffraction measurements. The slits act on diffracted X‐rays to select a particular gauge volume of sample, while absorbing diffracted X‐rays from outside of this volume. Although the slit geometry is to some extent similar to that of previously developed conical slits or spiral slits, this new design has advantages over the previous ones in use for complex heterogeneous materials and in situ and operando diffraction measurements. For example, the slits can measure a majority of any diffraction cone for any polycrystalline material, over a continuous range of diffraction angles, and work for X‐ray energies of tens to hundreds of kiloelectronvolts. The design is generated and optimized using ray‐tracing simulations, and fabricated through laser micromachining. The first prototype was successfully tested at the X17A beamline at the National Synchrotron Light Source, and shows similar performance to simulations, demonstrating gauge volume selection for standard powders, for all diffraction peaks over angles of 2–10°. A similar, but improved, design will be implemented at the X‐ray Powder Diffraction beamline at the National Synchrotron Light Source II.  相似文献   

15.
X‐ray absorption near‐edge structure (XANES) and X‐ray photoelectron spectroscopy (XPS) of Nd‐doped phosphate glasses have been studied before and after gamma irradiation. The intensity and the location of the white line peak of the L3‐edge XANES of Nd are found to be dependent on the ratio O/Nd in the glass matrix. Gamma irradiation changes the elemental concentration of atoms in the glass matrix, which affects the peak intensity of the white line due to changes in the covalence of the chemical bonds with Nd atoms in the glass (structural changes). Sharpening of the Nd 3d5/2 peak profile in XPS spectra indicates a deficiency of oxygen in the glasses after gamma irradiation, which is supported by energy‐dispersive X‐ray spectroscopy measurements. The ratio of non‐bridging oxygen to total oxygen in the glass after gamma radiation has been found to be correlated to the concentration of defects in the glass samples, which are responsible for its radiation resistance as well as for its coloration.  相似文献   

16.
Synchrotron‐based scanning transmission soft X‐ray microscopy (STXM) with nanometer resolution was used to investigate the existence and behavior of interfacial gas nanobubbles confined between two silicon nitride windows. The observed nanobubbles of SF6 and Ne with diameters smaller than 2.5 µm were quite stable. However, larger bubbles became unstable and grew during the soft X‐ray imaging, indicating that stable nanobubbles may have a length scale, which is consistent with a previous report using atomic force microscopy [Zhang et al. (2010), Soft Matter, 6 , 4515–4519]. Here, it is shown that STXM is a promising technique for studying the aggregation of gases near the solid/water interfaces at the nanometer scale.  相似文献   

17.
18.
X‐ray magnetic circular dichroism (XMCD) has become in recent years an outstanding tool for studying magnetism. Its element specificity, inherent to core‐level spectroscopy, combined with the application of magneto‐optical sum rules allows quantitative magnetic measurements at the atomic level. These capabilities are now incorporated as a standard tool for studying the localized magnetism in many systems. However, the application of XMCD to the study of the conduction‐band magnetism is not so straightforward. Here, it is shown that the atomic selectivity is not lost when XMCD probes the delocalized states. On the contrary, it provides a direct way of disentangling the magnetic contributions to the conduction band coming from the different elements in the material. This is demonstrated by monitoring the temperature dependence of the XMCD spectra recorded at the rare‐earth L2‐edge in the case of RT2 (R = rare‐earth, T = 3d transition metal) materials. These results open the possibility of performing element‐specific magnetometry by using a single X‐ray absorption edge.  相似文献   

19.
The electrode of Li‐ion batteries is required to be chemically and mechanically stable in the electrolyte environment for in situ monitoring by transmission X‐ray microscopy (TXM). Evidence has shown that continuous irradiation has an impact on the microstructure and the electrochemical performance of the electrode. To identify the root cause of the radiation damage, a wire‐shaped electrode is soaked in an electrolyte in a quartz capillary and monitored using TXM under hard X‐ray illumination. The results show that expansion of the carbon–binder matrix by the accumulated X‐ray dose is the key factor of radiation damage. For in situ TXM tomography, intermittent X‐ray exposure during image capturing can be used to avoid the morphology change caused by radiation damage on the carbon–binder matrix.  相似文献   

20.
A portable powder–liquid high‐corrosion‐resistant reaction cell has been designed to follow in situ reactions by X‐ray powder diffraction (XRD) and X‐ray absorption spectroscopy (XAS) techniques. The cell has been conceived to be mounted on the experimental stations for diffraction and absorption of the Spanish CRG SpLine‐BM25 beamline at the European Synchrotron Radiation Facility. Powder reactants and/or products are kept at a fixed position in a vertical geometry in the X‐ray pathway by a porous membrane, under forced liquid reflux circulation. Owing to the short pathway of the X‐ray beam through the cell, XRD and XAS measurements can be carried out in transmission configuration/mode. In the case of the diffraction technique, data can be collected with either a point detector or a two‐dimensional CCD detector, depending on specific experimental requirements in terms of space or time resolution. Crystallization processes, heterogeneous catalytic processes and several varieties of experiments can be followed by these techniques with this cell. Two experiments were carried out to demonstrate the cell feasibility: the phase transformations of layered titanium phosphates in boiling aqueous solutions of phosphoric acid, and the reaction of copper carbonate and l ‐isoleucine amino acid powders in boiling aqueous solution. In this last case the shrinking of the solid reactants and the formation of Cu(isoleucine)2 is observed. The crystallization processes and several phase transitions have been observed during the experiments, as well as an unexpected reaction pathway.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号