首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A single‐crystal momentum‐resolved resonant inelastic X‐ray scattering (RIXS) experiment under high pressure using an originally designed diamond anvil cell (DAC) is reported. The diamond‐in/diamond‐out geometry was adopted with both the incident and scattered beams passing through a 1 mm‐thick diamond. This enabled us to cover wide momentum space keeping the scattering angle condition near 90°. Elastic and inelastic scattering from the diamond was drastically reduced using a pinhole placed after the DAC. Measurement of the momentum‐resolved RIXS spectra of Sr2.5Ca11.5Cu24O41 at the Cu K‐edge was thus successful. Though the inelastic intensity becomes weaker by two orders than the ambient pressure, RIXS spectra both at the center and the edge of the Brillouin zone were obtained at 3 GPa and low‐energy electronic excitations of the cuprate were found to change with pressure.  相似文献   

2.
A compact and portable magnet system for measuring magnetic dichroism in resonant inelastic soft X‐ray scattering (SX‐RIXS) has been developed at the beamline BL07LSU in SPring‐8. A magnetic circuit composed of Nd–Fe–B permanent magnets, which realised ~0.25 T at the center of an 11 mm gap, was rotatable around the axis perpendicular to the X‐ray scattering plane. Using the system, a SX‐RIXS spectrum was obtained under the application of the magnetic field at an angle parallel, nearly 45° or perpendicular to the incident X‐rays. A dedicated sample stage was also designed to be as compact as possible, making it possible to perform SX‐RIXS measurements at arbitrary incident angles by rotating the sample stage in the gap between the magnetic poles. This system enables facile studies of magnetic dichroism in SX‐RIXS for various experimental geometries of the sample and the magnetic field. A brief demonstration of the application is presented.  相似文献   

3.
X‐ray absorption and scattering spectroscopies involving the 3d transition‐metal K‐ and L‐edges have a long history in studying inorganic and bioinorganic molecules. However, there have been very few studies using the M‐edges, which are below 100 eV. Synchrotron‐based X‐ray sources can have higher energy resolution at M‐edges. M‐edge X‐ray absorption spectroscopy (XAS) and resonant inelastic X‐ray scattering (RIXS) could therefore provide complementary information to K‐ and L‐edge spectroscopies. In this study, M2,3‐edge XAS on several Co, Ni and Cu complexes are measured and their spectral information, such as chemical shifts and covalency effects, are analyzed and discussed. In addition, M2,3‐edge RIXS on NiO, NiF2 and two other covalent complexes have been performed and different dd transition patterns have been observed. Although still preliminary, this work on 3d metal complexes demonstrates the potential to use M‐edge XAS and RIXS on more complicated 3d metal complexes in the future. The potential for using high‐sensitivity and high‐resolution superconducting tunnel junction X‐ray detectors below 100 eV is also illustrated and discussed.  相似文献   

4.
Fast detectors employed at third‐generation synchrotrons have reduced collection times significantly and require the optimization of commercial as well as customized software packages for data reduction and analysis. In this paper a procedure to collect, process and analyze single‐crystal data sets collected at high pressure at the Extreme Conditions beamline (P02.2) at PETRA III, DESY, is presented. A new data image format called `Esperanto' is introduced that is supported by the commercial software package CrysAlisPro (Agilent Technologies UK Ltd). The new format acts as a vehicle to transform the most common area‐detector data formats via a translator software. Such a conversion tool has been developed and converts tiff data collected on a Perkin Elmer detector, as well as data collected on a MAR345/555, to be imported into the CrysAlisPro software. In order to demonstrate the validity of the new approach, a complete structure refinement of boron‐mullite (Al5BO9) collected at a pressure of 19.4 (2) GPa is presented. Details pertaining to the data collections and refinements of B‐mullite are presented.  相似文献   

5.
Advances in resonant inelastic X‐ray scattering (RIXS) have come in lockstep with improvements in energy resolution. Currently, the best energy resolution at the Ir L3‐edge stands at ~25 meV, which is achieved using a diced Si(844) spherical crystal analyzer. However, spherical analyzers are limited by their intrinsic reflection width. A novel analyzer system using multiple flat crystals provides a promising way to overcome this limitation. For the present design, an energy resolution at or below 10 meV was selected. Recognizing that the angular acceptance of flat crystals is severely limited, a collimating element is essential to achieve the necessary solid‐angle acceptance. For this purpose, a laterally graded, parabolic, multilayer Montel mirror was designed for use at the Ir L3‐absorption edge. It provides an acceptance larger than 10 mrad, collimating the reflected X‐ray beam to smaller than 100 µrad, in both vertical and horizontal directions. The performance of this mirror was studied at beamline 27‐ID at the Advanced Photon Source. X‐rays from a diamond (111) monochromator illuminated a scattering source of diameter 5 µm, generating an incident beam on the mirror with a well determined divergence of 40 mrad. A flat Si(111) crystal after the mirror served as the divergence analyzer. From X‐ray measurements, ray‐tracing simulations and optical metrology results, it was established that the Montel mirror satisfied the specifications of angular acceptance and collimation quality necessary for a high‐resolution RIXS multi‐crystal analyzer system.  相似文献   

6.
A theory program intended for use with extended X‐ray‐absorption fine structure (EXAFS) spectroscopy and based on the popular FEFF8 is presented. It provides an application programming interface designed to make it easy to integrate high‐quality theory into EXAFS analysis software. This new code is then used to examine the impact of self‐consistent scattering potentials on EXAFS data analysis by methodical testing of theoretical fitting standards against a curated suite of measured EXAFS data. For each data set, the results of a fit are compared using a well characterized structural model and theoretical fitting standards computed both with and without self‐consistent potentials. It is demonstrated that the use of self‐consistent potentials has scant impact on the results of the EXAFS analysis.  相似文献   

7.
《X射线光谱测定》2006,35(2):106-111
Dy2O3 and Dy metal's resonant inelastic x‐ray scattering (RIXS) spectra were measured in the Beijing Synchrotron Radiation Facility. As a bulk sensitive probe and two‐photon process, RIXS provides more information on the electronic structure of matter. In this full RIXS experiment, the 2p64fn→ 2p54fn5d1 (2p54fn + 15d0) → 2p63d94fn5d1 (2p63d94fn + 15d0) channel of two samples (Dy2O3 and Dy metal) was studied. Further comparison shows that there are many differences in the RIXS spectra. Dy metal has only a single resonance and its 5d band is broader than that of Dy2O3. In the resonant regime, it has a lower final state energy, whereas in the non‐resonant regime it exceeds Dy2O3. This causes a broader bandwidth of the main final state B and a narrower bandwidth in the resonant and non‐resonant regime. The pre‐edge structure in Dy L3 absorption spectra was also resolved using RIXS, which cannot be seen in conventional XAS owing to 2p core hole lifetime broadening. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

8.
A spectrometer for resonant inelastic X‐ray scattering (RIXS) is proposed where imaging and dispersion actions in two orthogonal planes are combined to deliver a full two‐dimensional map of RIXS intensity in one shot with parallel detection at incoming hvin and outgoing hvout photon energies. Preliminary ray‐tracing simulations with a typical undulator beamline demonstrate a resolving power well above 11000 with both hvin and hvout near 930 eV, with a vast potential for improvement. Combining this instrument – nicknamed hv2 spectrometer – with an X‐ray free‐electron laser source simplifies its technical implementation and enables efficient time‐resolved RIXS experiments.  相似文献   

9.
A novel diced spherical quartz analyzer for use in resonant inelastic X‐ray scattering (RIXS) is introduced, achieving an unprecedented energy resolution of 10.53 meV at the Ir L3 absorption edge (11.215 keV). In this work the fabrication process and the characterization of the analyzer are presented, and an example of a RIXS spectrum of magnetic excitations in a Sr3Ir2O7 sample is shown.  相似文献   

10.
Resonant X-ray inelastic scattering spectra have been measured in BeO, phenakite (Be2SiO4) and chrysoberyl (BeAl2O4) with the excitation energy near the beryllium K edge.The RIXS spectra excited in the vicinity of the Be 1s core resonance show two principal features: the scattering on a valence excitation (which at higher excitation energies verges into the characteristic Kα emission), and a remarkably strong energy loss sideband to the elastic scattering peak. The energy loss shoulder appears to result from lattice relaxation in the absorption site. The comparison of the RIXS spectra of phenakite, chrysoberyl and BeO shows that the strength of the low energy sideband differs greatly; it is strongest in BeO and weakest in phenakite. The Si 2p RIXS spectra of phenakite also display a similar strong sub-bandgap energy loss tail.To gain further insight to this process, transitions in a system with a single vibrational mode have been modelled. The phonon relaxation has been simulated empirically by “smearing” the photoabsortion-populated vibrational levels with lower levels. This simple model is able to qualitatively explain this wide energy loss shoulder.  相似文献   

11.
The resonant inelastic x-ray scattering (RIXS) cross section at the L and M edges of transition-metal compounds is studied using an effective scattering operator. The intensities of the elastic peak and for spin-flip processes are derived. It is shown how the polarization dependence can be used to select transitions. Comparisons are made with experiment. A detailed analysis of the polarization and angular dependence of L- and M-edge RIXS for divalent copper compounds, such as the high-Tc superconductors, is given.  相似文献   

12.
实验势精修是20世纪80年代英国散裂中子源无定型材料组开发的用于分析中子散射实验数据的软件. 实验势精修的目标是根据中子散射数据重建样品的三维原子结构. 在过去的几十年,实验势精修被广泛用于中子散射实验数据分析,为实验用户提供了可靠的分析结果. 但是实验势精修是基于共享内存并行计算(OpenMP)的Fortran程序,不支持计算机服务器集群跨节点并行加速和GPU加速;这限制了它的分析速度. 随着计算机服务器集群的广泛建设和GPU加速技术的普遍使用,有必要重新编写EPSR程序以提高运算速度. 本文使用面向对象的C++语言,开发了一套实现EPSR算法的开源软件包NeuDATool;软件通过MPI和CUDA C实现了计算机集群跨节点并行和GPU加速. 使用液态水和玻璃态二氧化硅的中子散射实验数据对软件进行了测试. 测试显示软件可以正确重建出样品的三维原子结构;并且模拟体系达到10万原子以上时,使用GPU加速可以比串行的CPU算法提高400倍以上的模拟速度. NeuDATool为中子实验用户尤其是对熟悉C++编程并希望定义特殊分析算法的实验科学家提供了一种新的选择.  相似文献   

13.
A simple, inexpensive procedure is described for calibrating a silicon drift detector‐based PIXE system for the analysis of geological and other “thick‐target” materials. It rests on the use of single element, chemical compound, and National Institute for Standards and Technology multielement standards. Much less effort has been focussed on the impact of mass attenuation coefficients on PIXE's analytical accuracy than on ionization cross sections and fluorescence yields. The calibrated system enables us to investigate the effects of inserting different mass attenuation coefficient datasets into the GUPIX database. For the K X‐rays of light elements, accuracy is significantly improved by replacing the formerly used XCOM self‐attenuation coefficients by the corresponding FFAST values; this effect decreases rapidly with increasing atomic number. Similar improvement was found for L X‐rays of medium‐Z, but not for high‐Z atoms.  相似文献   

14.
15.
The dispersion of the elusive elementary excitations of orbital ordered systems, orbitons, has escaped detection so far. The recent advances in resonant inelastic x-ray scattering (RIXS) techniques have made it, in principle, a powerful new probe of orbiton dynamics. We compute the detailed traces that orbitons leave in RIXS for an e{g} orbital ordered system, using the ultrashort core-hole lifetime expansion for RIXS. We observe that both single- and double-orbiton excitations are allowed, where the former, at lower energy, have sharper features. The rich energy- and momentum-dependent intensity variations that we observe make clear that RIXS is an ideal method to identify and map out orbiton dispersions.  相似文献   

16.
17.

Stanford Synchrotron Radiation Laboratory (SSRL) entered a new era of synchrotron radiation experimentation in March 2004 with the start of the first experimental run following the completion of the SPEAR3 upgrade project [1]. Intense X-rays at the macromolecular crystallography stations, combined with state-of-the-art equipment, including high-speed CCD detectors and sophisticated control system software, now enable high-quality diffraction images to be collected in only a few seconds and entire crystallography datasets in a matter of minutes.

With significant reduction in the time required to collect a dataset, the period necessary to enter the experimental hutch to manually mount and dismount crystal samples is often a significant percentage of the users' total beam time allocation.  相似文献   

18.
Automated scanning capabilities have been added to the data acquisition software, JBluIce‐EPICS, at the National Institute of General Medical Sciences and the National Cancer Institute Collaborative Access Team (GM/CA CAT) at the Advanced Photon Source. A `raster' feature enables sample centering via diffraction scanning over two‐dimensional grids of simple rectangular or complex polygonal shape. The feature is used to locate crystals that are optically invisible owing to their small size or are visually obfuscated owing to properties of the sample mount. The raster feature is also used to identify the best‐diffracting regions of large inhomogeneous crystals. Low‐dose diffraction images taken at grid positions are automatically processed in real time to provide a quick quality ranking of potential data‐collection sites. A `vector collect' feature mitigates the effects of radiation damage by scanning the sample along a user‐defined three‐dimensional vector during data collection to maximize the use of the crystal volume and the quality of the collected data. These features are integrated into the JBluIce‐EPICS data acquisition software developed at GM/CA CAT where they are used in combination with a robust mini‐beam of rapidly changeable diameter from 5 µm to 20 µm. The powerful software–hardware combination is being applied to challenging problems in structural biology.  相似文献   

19.
20.
The new synchrotron‐radiation circular‐dichroism (SRCD) endstation on the UV‐visible synchrotron beamline DISCO has been commissioned at the SOLEIL synchrotron. The design has been focused on preservation of a high degree of linear polarization at high flux and moderate resolving power covering the vacuum ultraviolet to visible spectral range (125–600 nm). The beam dimensions have been set to 4 mm × 4 mm at 1 nm bandwidth for lower sample degradation. The nitrogen‐purged sample chamber fits three types of sample holders accommodating conventional round cell mounting, automated rotation of the samples, as well as a microfluidic set‐up. Automated temperature‐controlled data collection on microvolumes is now available to the biology and chemistry communities. Macromolecules including membrane proteins, soluble proteins, bio‐nanotubes, sugars, DNA and RNAs are now routinely investigated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号