首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
X‐ray analyzer‐based phase‐contrast imaging is combined with computed laminography for imaging regions of interest in laterally extended flat specimens of weak absorption contrast. The optics discussed here consist of an asymmetrically cut collimator crystal and a symmetrically cut analyzer crystal arranged in a nondispersive (+, ?) diffraction geometry. A generalized algorithm is given for calculating multi‐contrast (absorption, refraction and phase contrast) images of a sample. Basic formulae are also presented for laminographic reconstruction. The feasibility of the method discussed was verified at the vertical wiggler beamline BL‐14B of the Photon Factory. At a wavelength of 0.0733 nm, phase‐contrast sectional images of plastic beads were successfully obtained. Owing to strong circular artifacts caused by a sample holder, the field of view was limited to about 6 mm in diameter.  相似文献   

2.
X‐ray phase‐contrast imaging is an effective approach to drastically increase the contrast and sensitivity of microtomographic techniques. Numerous approaches to depict the real part of the complex‐valued refractive index of a specimen are nowadays available. A comparative study using experimental data from grating‐based interferometry and propagation‐based phase contrast combined with single‐distance phase retrieval applied to a non‐homogeneous sample is presented (acquired at beamline ID19‐ESRF). It is shown that grating‐based interferometry can handle density gradients in a superior manner. The study underlines the complementarity of the two techniques for practical applications.  相似文献   

3.
Visualization of the microvascular network and thrombi in the microvasculature is a key step to evaluating the development of tumor growth and metastasis, and influences treatment selection. X‐ray phase‐contrast computed tomography (PCCT) is a new imaging technique that can detect minute changes of density and reveal soft tissues discrimination at micrometer‐scale resolution. In this study, six human resected hepatocellular carcinoma (HCC) tissues were investigated with PCCT. A histological stain was added to estimate the accuracy of PCCT. The results showed that the fine structures of the microvasculature (measuring 30–100 µm) and thrombi in tiny blood vessels were displayed clearly on imaging the HCC tissues by PCCT. Moreover, density distributions of the thrombi were obtained, which could be reliably used to distinguish malignant from benign thrombi in HCC. In conclusion, PCCT can clearly show the three‐dimensional subtle structures of HCC that cannot be detected by conventional absorption‐based computed tomography and provides a new method for the imageology of HCC.  相似文献   

4.
Propagation‐based phase‐contrast X‐ray imaging (PB‐PCXI) using synchrotron radiation has achieved high‐resolution imaging of the lungs of small animals both in real time and in vivo. Current studies are applying such imaging techniques to lung disease models to aid in diagnosis and treatment development. At the Australian Synchrotron, the Imaging and Medical beamline (IMBL) is well equipped for PB‐PCXI, combining high flux and coherence with a beam size sufficient to image large animals, such as sheep, due to a wiggler source and source‐to‐sample distances of over 137 m. This study aimed to measure the capabilities of PB‐PCXI on IMBL for imaging small animal lungs to study lung disease. The feasibility of combining this technique with computed tomography for three‐dimensional imaging and X‐ray velocimetry for studies of airflow and non‐invasive lung function testing was also investigated. Detailed analysis of the role of the effective source size and sample‐to‐detector distance on lung image contrast was undertaken as well as phase retrieval for sample volume analysis. Results showed that PB‐PCXI of lung phantoms and mouse lungs produced high‐contrast images, with successful computed tomography and velocimetry also being carried out, suggesting that live animal lung imaging will also be feasible at the IMBL.  相似文献   

5.
Phase‐contrast X‐ray imaging using a crystal X‐ray interferometer can depict the fine structures of biological objects without the use of a contrast agent. To obtain higher image contrast, fixation techniques have been examined with 100% ethanol and the commonly used 10% formalin, since ethanol causes increased density differences against background due to its physical properties and greater dehydration of soft tissue. Histological comparison was also performed. A phase‐contrast X‐ray system was used, fitted with a two‐crystal X‐ray interferometer at 35 keV X‐ray energy. Fine structures, including cortex, tubules in the medulla, and the vessels of ethanol‐fixed kidney could be visualized more clearly than that of formalin‐fixed tissues. In the optical microscopic images, shrinkage of soft tissue and decreased luminal space were observed in ethanol‐fixed kidney; and this change was significantly shown in the cortex and outer stripe of the outer medulla. The ethanol fixation technique enhances image contrast by approximately 2.7–3.2 times in the cortex and the outer stripe of the outer medulla; the effect of shrinkage and the physical effect of ethanol cause an increment of approximately 78% and 22%, respectively. Thus, the ethanol‐fixation technique enables the image contrast to be enhanced in phase‐contrast X‐ray imaging.  相似文献   

6.
A new data collection strategy for performing synchrotron energy‐dispersive X‐ray diffraction computed tomography has been devised. This method is analogous to angle‐dispersive X‐ray diffraction whose diffraction signal originates from a line formed by intersection of the incident X‐ray beam and the sample. Energy resolution is preserved by using a collimator which defines a small sampling voxel. This voxel is translated in a series of parallel straight lines covering the whole sample and the operation is repeated at different rotation angles, thus generating one diffraction pattern per translation and rotation step. The method has been tested by imaging a specially designed phantom object, devised to be a demanding validator for X‐ray diffraction imaging. The relative strengths and weaknesses of the method have been analysed with respect to the classic angle‐dispersive technique. The reconstruction accuracy of the method is good, although an absorption correction is required for lower energy diffraction because of the large path lengths involved. The spatial resolution is only limited to the width of the scanning beam owing to the novel collection strategy. The current temporal resolution is poor, with a scan taking several hours. The method is best suited to studying large objects (e.g. for engineering and materials science applications) because it does not suffer from diffraction peak broadening effects irrespective of the sample size, in contrast to the angle‐dispersive case.  相似文献   

7.
Results are presented of a recent experiment at the Imaging and Medical beamline of the Australian Synchrotron intended to contribute to the implementation of low‐dose high‐sensitivity three‐dimensional mammographic phase‐contrast imaging, initially at synchrotrons and subsequently in hospitals and medical imaging clinics. The effect of such imaging parameters as X‐ray energy, source size, detector resolution, sample‐to‐detector distance, scanning and data processing strategies in the case of propagation‐based phase‐contrast computed tomography (CT) have been tested, quantified, evaluated and optimized using a plastic phantom simulating relevant breast‐tissue characteristics. Analysis of the data collected using a Hamamatsu CMOS Flat Panel Sensor, with a pixel size of 100 µm, revealed the presence of propagation‐based phase contrast and demonstrated significant improvement of the quality of phase‐contrast CT imaging compared with conventional (absorption‐based) CT, at medically acceptable radiation doses.  相似文献   

8.
In‐line X‐ray phase‐contrast computed tomography (IL‐PCCT) can reveal fine inner structures for low‐Z materials (e.g. biological soft tissues), and shows high potential to become clinically applicable. Typically, IL‐PCCT utilizes filtered back‐projection (FBP) as the standard reconstruction algorithm. However, the FBP algorithm requires a large amount of projection data, and subsequently a large radiation dose is needed to reconstruct a high‐quality image, which hampers its clinical application in IL‐PCCT. In this study, an iterative reconstruction algorithm for IL‐PCCT was proposed by combining the simultaneous algebraic reconstruction technique (SART) with eight‐neighbour forward and backward (FAB8) diffusion filtering, and the reconstruction was performed using the Shepp–Logan phantom simulation and a real synchrotron IL‐PCCT experiment. The results showed that the proposed algorithm was able to produce high‐quality computed tomography images from few‐view projections while improving the convergence rate of the computed tomography reconstruction, indicating that the proposed algorithm is an effective method of dose reduction for IL‐PCCT.  相似文献   

9.
The first imaging results obtained from a small‐size synchrotron are reported. The newly developed Compact Light Source produces inverse Compton X‐rays at the intersection point of the counter propagating laser and electron beam. The small size of the intersection point gives a highly coherent cone beam with a few milliradian angular divergence and a few percent energy spread. These specifications make the Compact Light Source ideal for a recently developed grating‐based differential phase‐contrast imaging method.  相似文献   

10.
Synchrotron radiation inline phase‐contrast imaging combined with computed tomography (SR‐inline‐PCI‐CT) offers great potential for non‐invasive characterization and three‐dimensional visualization of fine features in weakly absorbing materials and tissues. For cartilage tissue engineering, the biomaterials and any associated cartilage extracellular matrix (ECM) that is secreted over time are difficult to image using conventional absorption‐based imaging techniques. For example, three‐dimensional printed polycaprolactone (PCL)/alginate/cell hybrid constructs have low, but different, refractive indices and thicknesses. This paper presents a study on the optimization and utilization of inline‐PCI‐CT for visualizing the components of three‐dimensional printed PCL/alginate/cell hybrid constructs for cartilage tissue engineering. First, histological analysis using Alcian blue staining and immunofluorescent staining assessed the secretion of sulfated glycosaminoglycan (GAGs) and collagen type II (Col2) in the cell‐laden hybrid constructs over time. Second, optimization of inline PCI‐CT was performed by investigating three sample‐to‐detector distances (SDD): 0.25, 1 and 3 m. Then, the optimal SDD was utilized to visualize structural changes in the constructs over a 42‐day culture period. The results showed that there was progressive secretion of cartilage‐specific ECM by ATDC5 cells in the hybrid constructs over time. An SDD of 3 m provided edge‐enhancement fringes that enabled simultaneous visualization of all components of hybrid constructs in aqueous solution. Structural changes that might reflect formation of ECM also were evident in SR‐inline‐PCI‐CT images. Summarily, SR‐inline‐PCI‐CT images captured at the optimized SDD enables visualization of the different components in hybrid cartilage constructs over a 42‐day culture period.  相似文献   

11.
Phase‐contrast X‐ray imaging using a paper analyzer enables the visualization of X‐ray transparent biological structures using the refractive properties of the sample. The technique measures the sample‐induced distortions of a spatially random reference pattern to retrieve quantitative sample information. This phase‐contrast method is promising for biomedical application due to both a simple experimental set‐up and a capability for real‐time imaging. The authors explore the experimental configuration required to achieve robustness and accuracy in terms of (i) the paper analyzer feature size, (ii) the sample‐to‐detector distance, and (iii) the exposure time. Results using a synchrotron source confirm that the technique achieves accurate phase retrieval with a range of paper analyzers and at exposures as short as 0.5 ms. These exposure times are sufficiently short relative to characteristic physiological timescales to enable real‐time dynamic imaging of living samples. A theoretical guide to the choice of sample‐to‐detector distance is also derived. While the measurements are specific to the set‐up, these guidelines, the example speckle images, the strategies for analysis in the presence of noise and the experimental considerations and discussion will be of value to those who wish to use the speckle‐tracking paper analyzer technique.  相似文献   

12.
13.
Dental burs are used extensively in dentistry to mechanically prepare tooth structures for restorations (fillings), yet little has been reported on the bur debris left behind in the teeth, and whether it poses potential health risks to patients. Here it is aimed to image dental bur debris under dental fillings, and allude to the potential health hazards that can be caused by this debris when left in direct contact with the biological surroundings, specifically when the debris is made of a non‐biocompatible material. Non‐destructive micro‐computed tomography using the BioMedical Imaging & Therapy facility 05ID‐2 beamline at the Canadian Light Source was pursued at 50 keV and at a pixel size of 4 µm to image dental bur fragments under a composite resin dental filling. The bur's cutting edges that produced the fragment were also chemically analyzed. The technique revealed dental bur fragments of different sizes in different locations on the floor of the prepared surface of the teeth and under the filling, which places them in direct contact with the dentinal tubules and the dentinal fluid circulating within them. Dispersive X‐ray spectroscopy elemental analysis of the dental bur edges revealed that the fragments are made of tungsten carbide–cobalt, which is bio‐incompatible.  相似文献   

14.
A full‐field hard X‐ray imaging beamline (BL‐4) was designed, developed, installed and commissioned recently at the Indus‐2 synchrotron radiation source at RRCAT, Indore, India. The bending‐magnet beamline is operated in monochromatic and white beam mode. A variety of imaging techniques are implemented such as high‐resolution radiography, propagation‐ and analyzer‐based phase contrast imaging, real‐time imaging, absorption and phase contrast tomography etc. First experiments on propagation‐based phase contrast imaging and micro‐tomography are reported.  相似文献   

15.
Using a two‐crystal‐interferometer‐based phase‐contrast X‐ray imaging system, the portal vein, capillary vessel area and hepatic vein of live rats were revealed sequentially by injecting physiological saline via the portal vein. Vessels greater than 0.06 mm in diameter were clearly shown with low levels of X‐rays (552 µGy). This suggests that in vivo vessel imaging of small animals can be performed as conventional angiography without the side effects of the presently used iodine contrast agents.  相似文献   

16.
X‐ray fluorescence nanotomography provides unprecedented sensitivity for studies of trace metal distributions in whole biological cells. Dose fractionation, in which one acquires very low dose individual projections and then obtains high statistics reconstructions as signal from a voxel is brought together (Hegerl & Hoppe, 1976), requires accurate alignment of these individual projections so as to correct for rotation stage runout. It is shown here that differential phase contrast at 10.2 keV beam energy offers the potential for accurate cross‐correlation alignment of successive projections, by demonstrating that successive low dose, 3 ms per pixel, images acquired at the same specimen position and rotation angle have a narrower and smoother cross‐correlation function (1.5 pixels FWHM at 300 nm pixel size) than that obtained from zinc fluorescence images (25 pixels FWHM). The differential phase contrast alignment resolution is thus well below the 700 nm × 500 nm beam spot size used in this demonstration, so that dose fractionation should be possible for reduced‐dose, more rapidly acquired, fluorescence nanotomography experiments.  相似文献   

17.
Synchrotron‐radiation computed tomography has been applied in many research fields. Here, PITRE (Phase‐sensitive X‐ray Image processing and Tomography REconstruction) and PITRE_BM (PITRE Batch Manager) are presented. PITRE supports phase retrieval for propagation‐based phase‐contrast imaging/tomography (PPCI/PPCT), extracts apparent absorption, refractive and scattering information of diffraction enhanced imaging (DEI), and allows parallel‐beam tomography reconstruction for conventional absorption CT data and for PPCT phase retrieved and DEI‐CT extracted information. PITRE_BM is a batch processing manager for PITRE: it executes a series of tasks, created viaPITRE, without manual intervention. Both PITRE and PITRE_BM are coded in Interactive Data Language (IDL), and have a user‐friendly graphical user interface. They are freeware and can run on Microsoft Windows systems via IDL Virtual Machine, which can be downloaded for free and does not require a license. The data‐processing principle and some examples of application will be presented.  相似文献   

18.
A series of computed microtomography experiments are reported which were performed by using a third‐generation synchrotron radiation source on volcanic rocks from various active hazardous volcanoes in Italy and other volcanic areas in the world. The applied technique allowed the internal structure of the investigated material to be accurately imaged at the micrometre scale and three‐dimensional views of the investigated samples to be produced as well as three‐dimensional quantitative measurements of textural features. The geometry of the vesicle (gas‐filled void) network in volcanic products of both basaltic and trachytic compositions were particularly focused on, as vesicle textures are directly linked to the dynamics of volcano degassing. This investigation provided novel insights into modes of gas exsolution, transport and loss in magmas that were not recognized in previous studies using solely conventional two‐dimensional imaging techniques. The results of this study are important to understanding the behaviour of volcanoes and can be combined with other geosciences disciplines to forecast their future activity.  相似文献   

19.
A new method of phase‐shifting digital holography is demonstrated in the hard X‐ray region. An in‐line‐type phase‐shifting holography setup was installed in a 6.80 keV hard X‐ray synchrotron beamline. By placing a phase plate consisting of a hole and a band at the focusing point of a Fresnel lens, the relative phase of the reference and objective beams could be successfully shifted for use with a three‐step phase‐shift algorithm. The system was verified by measuring the shape of a gold test pattern and a silica sphere.  相似文献   

20.
Phase‐contrast synchrotron X‐ray microtomography (pcSyncX) based on the highly coherent X‐ray beam has previously been used to visualize the microstructures of biologic specimens, but it has never been used to evaluate embolic debris adherent on a cerebral protection device (CPD). The purpose of this study was to demonstrate the feasibility of pcSyncX for evaluating embolic debris during carotid artery stenting (CAS). Five patients (four males, age range 67–77 years) with severe carotid artery stenosis underwent CAS. The retrieved CPD was exposed to synchrotron radiation and 1000 pcSyncX projection images were obtained by rotating the CPD through 180°. An X‐ray shadow of a CPD was converted into a visual image by the scintillator. After microtomographic reconstruction, the three‐dimensionally reconstructed images were further segmented into the embolic debris and CPD. The total volume of emboli was calculated by summing the volume at each scanning level. The number of membrane pores covered by emboli as seen from the outer surface was counted and the percentage of covered area was calculated. Embolic debris was clearly demonstrated not only on the inner surface and within pores but also on the outer surface of the CPD. The mean total volume of embolic debris was 0.538 × 10–6 mm3 (range 0.225–0.965 × 10–6 mm3). Most (61.5%) of the debris was located at the apical one‐third of the CPD and 20.8% of the pore area was covered by debris.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏