首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Through blocking the cardiac persistent sodium current, riluzole has the potential to prevent myocardial damage post cardiac bypass surgery. A sensitive UHPLC–MS/MS method was developed and validated for quantitation of riluzole and 5‐methoxypsoralen in human plasma and myocardial tissue homogenate using a liquid–liquid extraction with dichloromethane. The chromatographic separation was achieved using Shimadzu Shim‐pack XR‐ODS III, 2.0 × 50 mm, 1.6 μm column with a gradient mobile phase comprising methanol and ammonium acetate buffer pH 3.6 in purified water. The analyte and internal standard were separated within 3.5 min. Riluzole quantitation was achieved using the mass transitions of 235–138 for riluzole and 217–156 for 5‐methoxypsoralen. The method was linear for riluzole plasma concentrations from 0.2 to 500 ng/mL and myocardial tissue homogenate concentrations from 0.2 to 100 ng/mL. The method developed was successfully applied to a clinical study for patients receiving riluzole while undergoing cardiac bypass surgery.  相似文献   

2.
A high performance liquid chromatographic method for the measurement of bemoradan levels in plasma/serum is described. This method uses Varian's AASP (Varian Associates, Sunnyvale, CA, USA), a semi-automatic liquid/solid extraction sample preparation system. It requires only small volumes of plasma/serum samples (0.2-1 mL) and needs no organic solvent for sample preparation. The mean recovery of bemoradan at plasma or serum concentrations of 0.5-100 ng/mL is 82%. The assay has a detection limit of 0.5 ng/mL (when 1 mL of plasma/serum is used) and is linear in the concentration range 0.5-500 ng/mL.  相似文献   

3.
A simple and sensitive reversed-phase liquid chromatography method was developed and validated for the determination of nicardipine hydrochloride (NC) in rabbit plasma. Nicardipine hydrochloride and nimodipine, used as internal standard, were initially extracted from plasma by a rapid solid-phase extraction using C(18) cartridges. After extraction, nicardipine hydrochloride was separated by HPLC on a C(18) column and quantified by ultraviolet detection at 254 nm. A mixture of acetonitrile-0.02 M sodium phosphate buffer-methanol (45:40:15) with 0.2% of triethylamine of pH of 6.1 was used as mobile phase. The mean (+/-SD) extraction efficiency of NC was 77.56 +/- 5.4, 84.23 +/- 4.32 and 83.94 +/- 3.87% for drug concentrations of 5, 25 and 100 ng/mL, respectively. The method proved to be linear in the range of 5-100 ng/mL with a regression coefficient of 0.9993. The relative standard deviations of intra- and inter-day analysis for NC in plasma were 3.26-6.52% (n = 5) and 4.71-9.38% (n = 5), respectively. The differences of the mean value measured from the concentration prepared, expressed in percentages (bias percentage), were only - 5.2, 0.4 and 0.8% at NC 5, 25 and 50 ng/mL, which confirmed the accuracy of the method. The analytical technique was used to determine NC plasma concentration after drug oral administration to rabbits. The results inferred that NC is rapidly absorbed in rabbits and has a short half-life (t(1/2) = 1.34 h).  相似文献   

4.
The new-generation nebulizers are commonly used for the administration of salbutamol in mechanically ventilated patients. The different modes of administration and new devices have not been compared. We developed a liquid chromatography-tandem mass spectrometry method for the determination of concentrations as low as 0.05 ng/mL of salbutamol, corresponding to the desired plasma concentration after inhalation. Salbutamol quantification was performed by reverse-phase HPLC. Analyte quantification was performed by electrospray ionization-triple quadrupole mass spectrometry using selected reaction monitoring detection ESI in the positive mode. The method was validated over concentrations ranging from 0.05 to 100 ng/mL in plasma and from 0.18 to 135 ng/mL in urine. The method is precise, with mean inter-day coefficient of variation (CV%) within 3.1-8.3% in plasma and 1.3-3.9% in urine, as well as accurate. The proposed method was found to reach the required sensitivity for the evaluation of different nebulizers as well as nebulization modes. The present assay was applied to examine whether salbutamol urine levels, normalized with the creatinine levels, correlated with the plasma concentrations. A suitable, convenient and noninvasive method of monitoring patients receiving salbutamol by mechanical ventilation could be implemented.  相似文献   

5.
A simple and sensitive HPLC-UV method was developed for the determination of paclitaxel (TXL) in human and rat blood samples. 4-Hydroxybenzoic acid n-hexyl ester was used as an internal standard. TXL was extracted by a liquid-liquid extraction with tert-butylmethyl ether. The disturbing peaks in the case of serum sample were removed by pre-extraction with hexane. The separation of TXL was achieved within 25 min using an ODS column with 50% acetonitrile aqueous solution as a mobile phase at a flow rate of 1.0 mL/min. The eluent was monitored at 230 nm, and the resulted retention times of TXL and IS were 11.2 and 20.4 min. The detection limits of TXL for human plasma, serum and rat plasma samples at a signal-to-noise ratio of 3 were 10, 9.5 and 7.5 ng/mL, respectively. The proposed methods were applicable to the determination of TXL in human patients' plasma ranging from 15 to 27 ng/mL. Furthermore, monitoring of the time course of TXL after its single administration to rat could be demonstrated.  相似文献   

6.
A high-performance liquid chromatographic (HPLC) method has been developed for the simultaneous determination of fluvoxamine and its major metabolite fluvoxamino acid in plasma. Fluvoxamine and fluvoxamino acid in plasma were extracted using a C18 bonded-solid phase cartridge, followed by C4 reversed-phase HPLC separation.Fluvoxamine, fluvoxamino acid and moperone as an internal standard were detected by ultraviolet absorbance at 254 nm. It was possible to determine both fluvoxamine and fluvoxamino acid in the concentration range of 25.0-200.0 ng/mL, respectively. The detection limits of both fluvoxamine and fluvoxamino acid were 10.0 ng/mL, respectively. The mean recoveries of fluvoxamine and fluvoxamino acid added to plasma were more than 94.0% and 96.5%, with a coefficient of variation of less than 7.6% and 8.2%, respectively. This method has been used for the simultaneous determination of steady-state plasma concentration (Css) of fluvoxamine and fluvoxamino acid in depressive patients treated with 200 mg of oral fluvoxamine dosed as 100 mg twice-daily. The Css values of fluvoxamine and fluvoxamino acid in twelve Japanese patients were showed individual variations, which were in the range of 48.3-532.9 ng/ml and 35.6-307.1 ng/ml, respectively.  相似文献   

7.
A novel, sensitive and specific method for the quantitative determination of diclazuril in animal plasma using liquid chromatography combined with electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) with negative ion detection is presented. Extraction of the samples was performed with a rapid deproteinization step using acetonitrile. Chromatography of diclazuril and the internal standard was achieved on a Nucleosil ODS 5-microm column, using a gradient elution with 0.01 M ammonium acetate and acetonitrile. To obtain the highest sensitivity and specificity possible, the mass spectrometer was operated in the multiple reaction monitoring (MRM) mode. The method was validated according to the requirements defined by the European Community. Calibration curves using plasma fortified between 1-100 ng/mL and 100-2000 ng/mL showed good linear correlation (r >or= 0.9991, goodness-of-fit coefficient 相似文献   

8.
A sensitive high-performance liquid chromatographic method with fluorescence detection (excitation 435 and emission 515 nm) was established and validated for quantification of five anthraquinones (aloe-emodin, rhein, emodin, chrysophanol and physcion) in rat plasma. Following a single-step liquid-liquid extraction, the analytes and internal standard (1,8-dihydroxyanthraquinone) were separated on a reversed-phase C(18) column with water-phosphoric acid-methanol as mobile phase at a flow rate of 1 mL/min. The linear ranges of the calibration curves were 6.5-1300 ng/mL for aloe-emodin, 20-4000 ng/mL for rhein, 40-8000 ng/mL for emodin, 15-3000 ng/mL for chrysophanol and 13-2600 ng/mL for physcion. The lower limit of quantification was 6.5 ng/mL for aloe-emodin, 20 ng/mL for rhein, 40 ng/mL for emodin, 15 ng/mL for chrysophanol and 13 ng/mL for physcion. The mean accuracy was 94.3-105.1% for aloe-emodin, 90.3-108.8% for rhein, 92.6-106.7% for emodin, 95.8-103.8% for chrysophanol and 98.7-101.2% for physcion. The within-batch and between-batch precisions were < or = 5.5% and < or = 13.4%, respectively. This method is suitable for determining the five anthraquinones in plasma simultaneously and thus investigating the pharmacokinetics of anthraquinones from Xiexin decoction in rats.  相似文献   

9.
A selective, sensitive and rapid liquid chromatography-tandem mass spectrometry method has been developed for the determination of caudatin-2,6-dideoxy-3-O-methy-beta-d-cymaropyranoside (CDMC) in rat plasma. This method involves a plasma clean-up step using liquid-liquid extraction, followed by LC separation and positive electrospray ionization mass spectrometry detection (LC/ESI-MS/MS). Chromatographic separation of the analytes was achieved using a C(18) column with a mobile phase of acetonitrile and water (70:30, v/v) at a flow rate of 1.0 mL/min. Low energy collision tandem mass spectrometric analysis (CID-MS/MS) using the multiple reaction monitoring (MRM) mode was used for analyte quantification. For the MRM analysis of CDMC, the following transition at m/z 658.4 --> 529.6 derived from the protonated molecule [M + Na](+). A calibration curve was linear in the 5-500 ng/mL range for CDMC, and the limit of detection was 5 ng/mL. The inter- and intra-day precisions (RSD) were 相似文献   

10.
A HPLC method has been developed for the simultaneous determination of seven tricyclic antidepressants (TCAs) and seven metabolites in human plasma. The analyte separation was obtained using a C8 reversed phase column and a mobile phase composed of 68% aqueous phosphate buffer at pH 3.0 and 32% ACN. The UV detector was set at 220 nm and loxapine was used as the internal standard. A careful pre‐treatment procedure for plasma samples was developed, using SPE on C2 cartridges, which gives satisfactory extraction yields (>80%) and good sample purification. The LOQs were always lower than 9.1 ng/mL and the LODs always lower than 3.1 ng/mL for all analytes. The method was successfully applied to plasma samples from depressed patients undergoing therapy with one or more TCA drugs. Precision data (RSD <8.1%), as well as accuracy results (recovery >80%), were satisfactory and no interference from other drugs was found. Hence the method seems to be suitable for the therapeutic drug monitoring of patients treated with TCAs under monotherapy or polypharmacy regimens.  相似文献   

11.
A sensitive high-performance liquid chromatographic method with fluorescence detection was developed to determine memantine (MT) in rat plasma. The method consists of pre-column labeling of MT with 4-(4,5-diphenyl-1H-imidazol-2-yl)benzoyl chloride (DIB-Cl) and a clean-up step with solid-phase extraction. A good separation of DIB-MT was achieved within 12 min on an octadecylsilica (ODS) column (150 × 4.6 mm i.d.; 5 μm) with a mobile phase of acetonitrile-water (70:30, v/v). The calibration curve prepared with fluoxetine as an internal standard showed good linearity in the range of 10-400 ng/mL (r = .999). The limits of detection and quantitation at signal-to-noise ratios of 3 and 10 were 2.0 and 6.6 ng/mL, respectively. The method was shown to be reliable with precisions of <5% for intra-day and <9% for inter-day as relative standard deviation. The fluorescence property and reaction yield of authentic DIB-MT were also examined. The proposed method was successfully applied to study the pharmacokinetic interaction between MT and methazolamide.  相似文献   

12.
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was developed and validated to simultaneously determine mifepristone and monodemethyl-mifepristone in human plasma using levonorgestrel as the internal standard (IS). After solid-phase extraction of the plasma samples, mifepristone, monodemethyl-mifepristone and the IS were subjected to LC-MS/MS analysis using electro-spray ionization (ESI) in the multiple reaction monitoring (MRM) mode. Chromatographic separation was performed on an XTERRA MS C(18) column (150 x 2.1 mm i.d., 5 microm). The method had a chromatographic run time of 4.5 min and linear calibration curves over the concentration ranges of 5-2000 ng/mL for mifepristone and monodemethyl-mifepristone. The recoveries of the method were found to be 94.5-103.7% for mifepristone and 70.7-77.3% for monodemethyl-mifepristone. The method had a lower limit of quantification (LLOQ) of 5.0 ng/mL and a lower limit of detection (LOD) of 1.0 ng/mL for both mifepristone and monodemethyl-mifepristone. The intra- and inter-batch precision was less than 15% for all quality control samples at concentrations of 10, 100 and 1000 ng/mL. These results indicate that the method was efficient with a short run time (4.5 min) and acceptable accuracy, precision and sensitivity. The validated LC-MS/MS method was successfully used in a pharmacokinetic study in healthy female volunteers after oral administration of 25 mg mifepristone tablet.  相似文献   

13.
A fully validated and clinically relevant assay was developed for the assessment of nevirapine concentrations in neonate blood plasma samples. Solid-phase extraction with an acid-base wash series was used to prepare subject samples for analysis. Samples were separated by high performance liquid chromatography and detected at 280 nm on a C8 reverse-phase column in an isocratic mobile phase. The retention times of nevirapine and its internal standard were 5.0 and 6.9 min, respectively. The method was validated by assessment of accuracy and precision (statistical values <15%), specificity, and stability. The assay was linear in the range 25-10,000 ng/mL (r2 > 0.996) and the average recovery was 93% (n = 18). The lower limit of quantification (relative standard deviation <20%) was determined to be 25 ng/mL for 50 microL of plasma, allowing detection of as little as 1.25 ng of nevirapine in a sample. This value represents an increase in sensitivity of up to 30-fold over previously published methods.  相似文献   

14.
A validated high-performance liquid chromatography (HPLC) method was developed for simultaneous determination and pharmacokinetic study of aloe emodin and chrysophanol in rats. It was performed on a reverse-phase C(18) column and a mobile phase made up of methanol and 0.2% acetic acid (83:17, v/v). The ultraviolet detection was 254 nm. 1,8-dihydroxyanthraquinone was used as the internal standard. The assay was linear over the range 28-2800 ng/mL (r(2) = 0.9993) for aloe emodin and 25.6-2560 ng/mL (r(2) = 0.9991) for chrysophanol. The average percentage recoveries of three spiked plasmas were 98.8-104.8% and 97.7-103.2% for aloe emodin and chrysophanol, respectively. Their RSD of intra-day and inter-day precision at concentrations of 56, 280 and 1400 ng/mL for aloe emodin and 51.6, 258 and 1290 ng/mL for chrysophanol were less than 3.5%. This method was applied for the first time to simultaneously determinate aloe emodin and chrysophanol in rats following oral administration of traditional Chinese medicine of Da-Cheng-Qi decoction. The pharmacokinetic parameters showed that chrysophanol was better absorbed with higher concentrations in plasma than aloe emodin did. They both eliminated slowly in male rats. The assay is suitable for identifying the plasma and tissue levels of aloe emodin and chrysophanol in preclinical investigations.  相似文献   

15.
A simple, sensitive, selective and reliable reversed-phase high-performance liquid chromatographic (HPLC) method with UV detection is described for the determination of naltrexone in plasma samples. Naltrexone and the internal standard, naloxone, were isolated from plasma either with a liquid-liquid extraction method using ethyl acetate or with a solid-phase extraction method using Sep-Pack C18 cartridge before chromatography. The extracts were dried under a stream of nitrogen and the samples were reconstituted in the mobile phase, then 20 microL were injected on a Waters Symmetry C18 column (5 microm particle size, 4.6 x 150 mm). The mobile phase consisted of 0.06% triethylamine (pH 2.8)-acetonitrile (92:8, v/v) pumped at 1 mL/min. The peak-area ratio versus plasma concentration was linear over the range of 10-500 ng/mL and the detection limit was less than 8 ng/mL. Quantification was by ultra-violet detection at 204 nm. The present method was applied to the determination of the plasma concentration of naltrexone in dialyzed patients. Patients (n = 8) with severe generalized pruritus received 50 mg of naltrexone orally per day for 2 weeks. The variability in the therapeutic response in treated patients required plasma concentration investigations of this opioid antagonist.  相似文献   

16.
A sensitive and specific method was developed and validated for the determination of mitiglinide in human plasma using liquid chromatographic separation with electrospray ionization tandem mass spectrometric detection. Acidified plasma samples were extracted with ethyl acetate. The chromatographic separation was performed on an Agilent Zorbax Eclipse Plus C(18) column with a mobile phase of methanol-10 mm ammonium acetate solution at a flow rate of 0.3 mL/min. Analytes were detected with an Agilent 6410 Triple qudrupole mass spectrometer equipped with an electrospray ionization source in positive multiple reaction monitoring mode: m/z 316.2 (precursor ion) to 298.2 (product ion) for mitiglinide and m/z 318.2 (precursor ion) to 120.2 (product ion) for the internal standard. This method was validated over a linear range of 0.5-4000 ng/mL for mitiglinide in human plasma. The lower limit of quantification (LLOQ) was 0.5 ng/mL, while a relative standard deviation (RSD) was less than 3.9%. The intra- and inter-run precision (as RSD, %) obtained from three validation runs were all less than 15%. The validated method was successfully used to analyze human plasma samples for application in pharmacokinetic studies.  相似文献   

17.
A rapid, sensitive and automated in-tube solid-phase microextraction-liquid chromatography-mass spectrometry (in-tube SPME/LC-MS) method was developed for the analysis of ten antidepressants in urine and plasma. A hybrid organic-inorganic silica monolith with cyanoethyl functional groups was prepared and used as a sorbent for in-tube SPME. Integration of the sample extraction, LC separation and MS detection into a single system permitted direct injection of the diluted urine or plasma after filtration. Under the optimized conditions, good extraction efficiencies for the targets were obtained with no matrix interference in the subsequent LC-MS. Automation of the sampling, extraction and separation procedures was realized under the control of a program in this study. The total process time was 30 min and only 30 μL of urine or plasma was required in one analysis cycle. Good linearities were obtained for ten antidepressants with the correlation coefficients (R) above 0.9933. The limits of detection (S/N=3) for ten antidepressants were found to be 0.06-2.84 ng/mL in urine and 0.07-2.95 ng/mL in plasma. The recoveries of antidepressants spiked in urine and plasma were from 75.2% to 113.0%, with relative standard deviations less than 16.5%. The developed method was successfully used to analyze urine sample from ageing patients undergoing therapy with antidepressants.  相似文献   

18.
A simple and sensitive reversed-phase high performance liquid chromatographic method (HPLC) has been developed and validated for the routine analysis of diltiazem in human plasma and the study of the pharmacokinetics of the drug in the human body. Diltiazem and diazepa (internal standard) were extracted with a mixed organic solution of hexane, chloroform and isopropanol (60:40:5, v/v/v), and then HPLC separation of the drugs was performed on an Spherisorb C(18) column and detected by ultraviolet absorbance at 239 nm. The use of methanol-water solution (containing 2.8 mm triethylamine, 80:20, v/v) as the mobile phase at a fl ow-rate of 1.2 mL/min enables the baseline separation of the drugs free from interferences with isocratic elution. The method was linear in the clinical range 0-300 ng/mL and the lower limit of detection of diltiazem in plasma was 3 ng/mL. The range of percentage of relative standard deviation (%RSD) was from 3.5 to 6.8% for within-day analyses and from 6.2 to 8.4% for between-day analyses, respectively. The extraction recoveries of diltiazem from spiked human plasma (n = 5) at three concentrations were 91.4-104.0%. The method has been used to determine diltiazem in human plasma samples from eight volunteers who had taken diltiazem hydrochloride slow release tables and the data obtained was fitted with a program on computer to study the pharmacokinetics. The results showed that the peak level in plasma approximately averaged 118.5 +/- 14.3 ng/mL at 3.1 +/- 0.4 h, and the areas under the drug concentration curves (AUC) was 793.1 +/- 83.1 ng.h/mL.  相似文献   

19.
Huperzine A is a potent, reversible acetylcholinesterase inhibitor. In the present work, a rapid and sensitive LC-MS-MS method for the determination of huperzine A in human plasma using codeine phosphate as internal standard has been developed and validated. The analyte and internal standard were extracted from plasma using ethyl acetate, chromatographed on a C(18) column (5 microm, 150 x 4.6 mm i.d.) with a mobile phase consisting of 1% formic acid-methanol (40:60, v/v), and detected using a tandem mass spectrometer with a TurboIonSpray ionization interface. The run time was only 2 min. Good linearity was achieved in the range 0.126 -25.2 ng/mL and the limit of detection in plasma was 0.064 ng/mL. The average recovery for huperzine A was 83.4% from plasma. The analytical sensitivity and accuracy of this assay is adequate for characterization of huperzine A in human plasma.  相似文献   

20.
A rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the estimation of amlodipine in human plasma. Amlodipine was extracted from human plasma by using a solid-phase extraction technique. Imipramine was used as the internal standard. A Hypersil BDS C18 column provided chromatographic separation of analytes followed by detection with mass spectrometry. The method involves a rapid solid-phase extraction from plasma, simple isocratic chromatography conditions and mass spectrometric detection that enables detection at sub-nanogram levels. The proposed method has been validated for a linear range of 0.1-10.0 ng/mL with correlation coefficient >or=0.9990. The intrarun and interrun precision and accuracy were within 10.0%. The overall recovery for amlodipine was 63.67%. Total run time was 3.2 min only.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号