首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Collision induced dissociation (CID) is one of the most established techniques for tandem mass spectrometry analysis. The CID of mass selected ion could be realized by ion resonance excitation with a digital rectangular waveform. The method is simple, and highly efficient CID result could be obtained by optimizing the experimental parameters, such as digital waveform voltage, frequency, and q value. In this work, the relationship between ion trapping waveform voltage and frequency at preselected q value, the relationship between waveform frequency and the q value at certain ion trapping voltage for optimum CID efficiency were investigated. Experiment results showed that the max CID efficiency of precursor reserpine ions can be obtained at different trapping waveform voltage and frequency when q and β are different. Based on systematic experimental analysis, the optimum experimental conditions for high CID efficiency can be calculated at any selected β or q. By using digital ion trap technology, the CID process and efficient fragmentation of parent ions can be realized by simply changing the trapping waveform amplitude, frequency, and the β values in the digital ion trap mass spectrometry. The technology and method are simple. It has potential use in ion trap mass spectrometry.
Graphical Abstract ?
  相似文献   

2.
Selective and nonselective cleavages in ion trap low-energy collision-induced dissociation (CID) experiments of the fragments generated from in-source decay (ISD) with matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) of intact proteins are described in both positive and negative ion modes. The MALDI-ISD spectra of the proteins demonstrate common, discontinuous, abundant c- and z′-ions originating from cleavage at the N–Cα bond of Xxx-Asp/Asn and Gly-Xxx residues in both positive- and negative-ion modes. The positive ion CID of the c- and z′-ions resulted in product ions originating from selective cleavage at Asp-Xxx, Glu-Xxx and Cys-Xxx residues. Nonselective cleavage product ions rationalized by the mechanism of a “mobile proton” are also observed in positive ion CID spectra. Negative ion CID of the ISD fragments results in complex product ions accompanied by the loss of neutrals from b-, c-, and y-ions. The most characteristic feature of negative ion CID is selective cleavage of the peptide bonds of acidic residues, Xxx-Asp/Glu/Cys. A definite influence of α-helix on the CID product ions was not obtained. However, the results from positive ion and negative ion CID of the MALDI-ISD fragments that may have long α-helical domains suggest that acidic residues in helix-free regions tend to degrade more than those in helical regions.
Figure
?  相似文献   

3.
The gas-phase structures of protein ions have been studied by electron transfer dissociation (ETD) and collision-induced dissociation (CID) after electrospraying these proteins from native-like solutions into a quadrupole ion trap mass spectrometer. Because ETD can break covalent bonds while minimally disrupting noncovalent interactions, we have investigated the ability of this dissociation technique together with CID to probe the sites of electrostatic interactions in gas-phase protein ions. By comparing spectra from ETD with spectra from ETD followed by CID, we find that several proteins, including ubiquitin, CRABP I, azurin, and β-2-microglobulin, appear to maintain many of the salt bridge contacts known to exist in solution. To support this conclusion, we also performed calculations to consider all possible salt bridge patterns for each protein, and we find that the native salt bridge pattern explains the experimental ETD data better than nearly all other possible salt bridge patterns. Overall, our data suggest that ETD and ETD/CID of native protein ions can provide some insight into approximate location of salt bridges in the gas phase.
Figure
?  相似文献   

4.
An ion mobility/time-of-flight mass spectrometer (IMS/TOF MS) platform that allows for resonant excitation collision induced dissociation (CID) is presented. Highly efficient, mass-resolved fragmentation without additional excitation of product ions was accomplished and over-fragmentation common in beam-type CID experiments was alleviated. A quadrupole ion guide was modified to apply a dipolar AC signal across a pair of rods for resonant excitation. The method was characterized with singly protonated methionine enkephalin and triply protonated peptide angiotensin I, yielding maximum CID efficiencies of 44 % and 84 %, respectively. The Mathieu qx,y parameter was set at 0.707 for these experiments to maximize pseudopotential well depths and CID efficiencies. Resonant excitation CID was compared with beam-type CID for the peptide mixture. The ability to apply resonant waveforms in mobility-resolved windows is demonstrated with a peptide mixture yielding fragmentation over a range of mass-to-charge (m/z) ratios within a single IMS-MS analysis.
Figure
?  相似文献   

5.
A systematic approach is described that can pinpoint the stereo-structures (sugar identity, anomeric configuration, and location) of individual sugar units within linear oligosaccharides. Using a highly modified mass spectrometer, dissociation of linear oligosaccharides in the gas phase was optimized along multiple-stage tandem dissociation pathways (MSn, n = 4 or 5). The instrument was a hybrid triple quadrupole/linear ion trap mass spectrometer capable of high-efficiency bidirectional ion transfer between quadrupole arrays. Different types of collision-induced dissociation (CID), either on-resonance ion trap or beam-type CID could be utilized at any given stage of dissociation, enabling either glycosidic bond cleavages or cross-ring cleavages to be maximized when wanted. The approach first involves optimizing the isolation of disaccharide units as an ordered set of overlapping substructures via glycosidic bond cleavages during early stages of MSn, with explicit intent to minimize cross-ring cleavages. Subsequently, cross-ring cleavages were optimized for individual disaccharides to yield key diagnostic product ions (m/z 221). Finally, fingerprint patterns that establish stereochemistry and anomeric configuration were obtained from the diagnostic ions via CID. Model linear oligosaccharides were derivatized at the reducing end, allowing overlapping ladders of disaccharides to be isolated from MSn. High confidence stereo-structural determination was achieved by matching MSn CID of the diagnostic ions to synthetic standards via a spectral matching algorithm. Using this MSn (n = 4 or 5) approach, the stereo-structures, anomeric configurations, and locations of three individual sugar units within two pentasaccharides were successfully determined.
Fig. a
?  相似文献   

6.
Structural elucidation and distinction of isomeric neurotoxic agents remain a challenge. Tandem mass spectrometry can be used for this purpose in particular if a “diagnostic” product ion is observed. Different vibrational activation methods were investigated to enhance formation of diagnostic ions through consecutive processes from O,O-dialkyl alkylphosphonates. Resonant and non-resonant collisional activation and infrared multiphoton dissociation (IRMPD) were used with different mass spectrometers: a hybrid quadrupole Fourier transform ion cyclotron resonance (Qh-FTICR) and a hybrid linear ion trap-Orbitrap (LTQ/Orbitrap). Double resonance (DR) experiments, in ion cyclotron resonance (ICR) cell, were used for unambiguous determination of direct intermediate yielding diagnostic ions. From protonated n-propyl and isopropyl O-O-dialkyl-phosphonates, a diagnostic m/z 83 ion characterizes the isopropyl isomer. This ion is produced through consecutive dissociation processes. Conditions to favor its formation and observation using different activation methods were investigated. It was shown that with the LTQ, consecutive experimental steps of isolation/activation with modified trapping conditions limiting the low mass cut off (LMCO) effect were required, whereas with FT-ICR by CID and IRMPD the diagnostic ion detection was provided only by one activation step. Among the different investigated activation methods it was shown that by using low-pressure conditions or using non-resonant methods, efficient and fast differentiation of isomeric neurotoxic agents was obtained. This work constitutes a unique comparison of different activation modes for distinction of isomers showing the instrumental dependence characteristic of the consecutive processes. New insights in the dissociation pathways were obtained based on double-resonance IRMPD experiments using a FT-ICR instrument with limitation at low mass values.
?  相似文献   

7.
A one-step enzymatic reaction for improving the collision-induced dissociation (CID)-based tandem mass spectrometry (MS/MS) analysis of phosphorylated peptides in an ion trap is presented. Carboxypeptidase-B (CBP-B) was used to selectively remove C-terminal arginine or lysine residues from phosphorylated tryptic/Lys-C peptides prior to their MS/MS analysis by CID with a Paul-type ion trap. Removal of this basic C-terminal residue served to limit the extent of gas-phase neutral loss of phosphoric acid (H3PO4), favoring the formation of diagnostic b and y ions as determined by an increase in both the number and relative intensities of the sequence-specific product ions. Such differential fragmentation is particularly valuable when the H3PO4 elimination is so predominant that localizing the phosphorylation site on the peptide sequence is hindered. Improvement in the quality of tandem mass spectral data generated by CID upon CBP-B treatment resulted in greater confidence both in assignment of the phosphopeptide primary sequence and for pinpointing the site of phosphorylation. Higher Mascot ion scores were also generated, combined with lower expectation values and higher delta scores for improved confidence in site assignment; Ascore values also improved. These results are rationalized in accordance with the accepted mechanisms for the elimination of H3PO4 upon low energy CID and insights into the factors dictating the observed dissociation pathways are presented. We anticipate this approach will be of utility in the MS analysis of phosphorylated peptides, especially when alternative electron-driven fragmentation techniques are not available.
Figure
?  相似文献   

8.
The ion enhanced activation and collision-induced dissociation (CID) by simultaneous dipolar excitation of ions in the two radial directions of linear ion trap (LIT) have been recently developed and tested by experiment. In this work, its detailed properties were further studied by theoretical simulation. The effects of some experimental parameters such as the buffer gas pressure, the dipolar excitation signal phases, power amplitudes, and frequencies on the ion trajectory and energy were carefully investigated. The results show that the ion activation energy can be significantly increased by dual-direction excitation using two identical dipolar excitation signals because of the addition of an excitation dimension and the fact that the ion motion radius related to ion kinetic energy can be greater than the field radius. The effects of higher-order field components, such as dodecapole field on the performance of this method are also revealed. They mainly cause ion motion frequency shift as ion motion amplitude increases. Because of the frequency shift, there are different optimized excitation frequencies in different LITs. At the optimized frequency, ion average energy is improved significantly with relatively few ions lost. The results show that this method can be used in different kinds of LITs such as LIT with 4-fold symmetric stretch, linear quadrupole ion trap, and standard hyperbolic LIT, which can significantly increase the ion activation energy and CID efficiency, compared with the conventional method.
Graphical Abstract ?
  相似文献   

9.
Microcystins (MC) are a large group of toxic cyclic peptides, produced by cyanobacteria in eutrophic water systems. Identification of MC variants mostly relies on liquid chromatography (LC) combined with collision-induced dissociation (CID) mass spectrometry. Deviations from the essential amino acid complement are a common feature of these natural products, which makes the CID analysis more difficult and not always successful. Here, both CID and electron capture dissociation (ECD) were applied in combination with ultra-high resolution Fourier transform ion cyclotron resonance mass spectrometry to study a cyanobacteria strain isolated from the Salto Grande Reservoir in Sao Paulo State, Brazil, without prior LC separation. CID was shown to be an effective dissociation technique for quickly identifying the MC variants, even those that have previously been difficult to characterize by CID. Moreover, ECD provided even more detailed and complementary information, which enabled us to precisely locate metal binding sites of MCs for the first time. This additional information will be important for environmental chemists to study MC accumulation and production in ecosystems.
Figure
?  相似文献   

10.
Sequence scrambling from y-type fragment ions has not been previously reported. In a study designed to probe structural variations among b-type fragment ions, it was noted that y fragment ions might also yield sequence-scrambled ions. In this study, we examined the possibility and extent of sequence-scrambled fragment ion generation from collision-induced dissociation (CID) of y-type ions from four peptides (all containing basic residues near the C-terminus) including: AAAAHAA-NH2 (where “A” denotes carbon thirteen (13C1) isotope on the alanine carbonyl group), des-acetylated-α-melanocyte (SYSMEHFRWGKPV-NH2), angiotensin II antipeptide (EGVYVHPV), and glu-fibrinopeptide b (EGVNDNEEGFFSAR). We investigated fragmentation patterns of 32 y-type fragment ions, including y fragment ions with different charge states (+1 to +3) and sizes (3 to 12 amino acids). Sequence-scrambled fragment ions were observed from ~50 % (16 out of 32) of the studied y-type ions. However, observed sequence-scrambled ions had low relative intensities from ~0.1 % to a maximum of ~12 %. We present and discuss potential mechanisms for generation of sequence-scrambled fragment ions. To the best of our knowledge, results on y fragment dissociation presented here provide the first experimental evidence for generation of sequence-scrambled fragments from CID of y ions through intermediate cyclic “b-type” ions.
Figure
?  相似文献   

11.
High-field asymmetric waveform ion mobility spectrometry (FAIMS) is shown to be capable of resolving isomeric and isobaric glycosaminoglycan negative ions and to have great utility for the analysis of this class of molecules when combined with Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) and tandem mass spectrometry. Electron detachment dissociation (EDD) and other ion activation methods for tandem mass spectrometry can be used to determine the sites of labile sulfate modifications and for assigning the stereochemistry of hexuronic acid residues of glycosaminoglycans (GAGs). However, mixtures with overlapping mass-to-charge values present a challenge, as their precursor species cannot be resolved by a mass analyzer prior to ion activation. FAIMS is shown to resolve two types of mass-to-charge overlaps. A mixture of chondroitin sulfate A (CSA) oligomers with 4–10 saccharides units produces ions of a single mass-to-charge by electrospray ionization, as the charge state increases in direct proportion to the degree of polymerization for these sulfated carbohydrates. FAIMS is shown to resolve the overlapping charge. A more challenging type of mass-to-charge overlap occurs for mixtures of diastereomers. FAIMS is shown to separate two sets of epimeric GAG tetramers. For the epimer pairs, the complexity of the separation is reduced when the reducing end is alkylated, suggesting that anomers are also resolved by FAIMS. The resolved components were activated by EDD and the fragment ions were analyzed by FTICR-MS. The resulting tandem mass spectra were able to distinguish the two epimers from each other.
Figure
?  相似文献   

12.
Space Charge Induced Nonlinear Effects in Quadrupole Ion Traps   总被引:1,自引:0,他引:1  
A theoretical method was proposed in this work to study space charge effects in quadrupole ion traps, including ion trapping, ion motion frequency shift, and nonlinear effects on ion trajectories. The spatial distributions of ion clouds within quadrupole ion traps were first modeled for both 3D and linear ion traps. It is found that the electric field generated by space charge can be expressed as a summation of even-order fields, such as quadrupole field, octopole field, etc. Ion trajectories were then solved using the harmonic balance method. Similar to high-order field effects, space charge will result in an “ocean wave” shape nonlinear resonance curve for an ion under a dipolar excitation. However, the nonlinear resonance curve will be totally shifted to lower frequencies and bend towards ion secular frequency as ion motion amplitude increases, which is just the opposite effect of any even-order field. Based on theoretical derivations, methods to reduce space charge effects were proposed.
Figure
?  相似文献   

13.
Stored waveform inverse Fourier transform and double resonance techniques have been used in conjunction with a quadrupole ion trap to study the dissociation patterns of peptide ions. These experiments provide insight into the origin of individual product ions in an MS/MS spectrum. Results show for a series of leucine enkephalin analogues with five amino acid residues that the b 4 ion is the main product ion through which many other product ions arise. It was also observed that the percentage of the a 4 product ions that are formed directly from the protonated molecule (M+H)+ depends on the nature of the fourth amino acid residue. In addition, it was determined that in the peptides studied here lower series b ions (e.g., b 3 arise from direct dissociation of higher series b ions (e.g., b 4 only about 50% of the time.  相似文献   

14.
We explore the feasibility of conducting electron ionization (EI) in a radio-frequency (rf) ion source trap for mass spectrometry applications. Electrons are radially injected into a compact linear ion trap in the presence of a magnetic field used essentially to lengthen the path of the electrons in the trap. The device can either be used as a stand-alone mass spectrometer or can be coupled to a mass analyzer. The applied parallel magnetic field and the oscillating rf electric field produced by the trap give rise to a set of coupled Mathieu equations of motion. Via numerical simulations, electron trajectories are studied under varying intensities of the magnetic field in order to determine the conditions that enhance ion production. Likewise, the dynamic behavior of the ions are investigated in the proposed EI source trap and the fast Fourier transform FFT formalism is used to obtain the frequency spectrum from the numerical simulations to study the motional frequencies of the ions which include combinations of the low-frequency secular and the high-frequency micromotion with magnetron and cyclotron frequencies. The dependence of these motional frequencies on the trapping conditions is examined and particularly, the limits of applying a radial magnetic field to the EI ion trap are characterized.
Figure
?  相似文献   

15.
16.
Obtaining unambiguous linkage information between sugars in oligosaccharides is an important step in their detailed structural analysis. An approach is described that provides greater confidence in linkage determination for linear oligosaccharides based on multiple-stage tandem mass spectrometry (MSn, n >2) and collision-induced dissociation (CID) of Z1 ions in the negative ion mode. Under low energy CID conditions, disaccharides 18O-labeled on the reducing carbonyl group gave rise to Z1 product ions (m/z 163) derived from the reducing sugar, which could be mass-discriminated from other possible structural isomers having m/z 161. MS3 CID of these m/z 163 ions showed distinct fragmentation fingerprints corresponding to the linkage types and largely unaffected by sugar unit identities or their anomeric configurations. This unique property allowed standard CID spectra of Z1 ions to be generated from a small set of disaccharide samples that were representative of many other possible isomeric structures. With the use of MSn CID (n = 3 – 5), model linear oligosaccharides were dissociated into overlapping disaccharide structures, which were subsequently fragmented to form their corresponding Z1 ions. CID data of these Z1 ions were collected and compared with the standard database of Z1 ion CID using spectra similarity scores for linkage determination. As the proof-of-principle tests demonstrated, we achieved correct determination of individual linkage types along with their locations within two trisaccharides and a pentasaccharide.
Figure
?  相似文献   

17.
Collision-induced dissociation (CID) of protonated N-benzylindoline and its derivatives was investigated by electrospray ionization tandem mass spectrometry (ESI-MS/MS). Elimination of benzene was observed besides hydride transfer and electron transfer reactions. D-labeling experiments and accurate mass determinations of the product ions confirm that the external proton is retained in the fragment ion, and the elimination reaction was proposed to be initiated by benzyl cation transfer rather than proton transfer. Benzyl cation transfer from the nitrogen atom to one of the sp2-hybridized carbon atoms in the indoline core is the key step, and subsequent proton transfer reaction leads to the elimination of benzene. Density functional theory (DFT)-based calculations were performed and the computational results also support the benzyl cation/proton transfer mechanism.
Figure
?  相似文献   

18.
Secular frequency scanning is implemented and characterized using both a benchtop linear ion trap and a miniature rectilinear ion trap mass spectrometer. Separation of tetraalkylammonium ions and those from a mass calibration mixture and from a pesticide mixture is demonstrated with peak widths approaching unit resolution for optimized conditions using the benchtop ion trap. The effects on the spectra of ion trap operating parameters, including waveform amplitude, scan direction, scan rate, and pressure are explored, and peaks at black holes corresponding to nonlinear (higher-order field) resonance points are investigated. Reverse frequency sweeps (increasing mass) on the Mini 12 are shown to result in significantly higher ion ejection efficiency and superior resolution than forward frequency sweeps that decrement mass. This result is accounted for by the asymmetry in ion energy absorption profiles as a function of AC frequency and the shift in ion secular frequency at higher amplitudes in the trap due to higher order fields. We also found that use of higher AC amplitudes in forward frequency sweeps biases ions toward ejection at points of higher order parametric resonance, despite using only dipolar excitation. Higher AC amplitudes also increase peak width and decrease sensitivity in both forward and reverse frequency sweeps. Higher sensitivity and resolution were obtained at higher trap pressures in the secular frequency scan, in contrast to conventional resonance ejection scans, which showed the opposite trend in resolution on the Mini 12. Mass range is shown to be naturally extended in secular frequency scanning when ejecting ions by sweeping the AC waveform through low frequencies, a method which is similar, but arguably superior, to the more usual method of mass range extension using low q resonance ejection.
Graphical Abstract ?
  相似文献   

19.
A miniature, planar, differential ion mobility spectrometer (DMS) was interfaced to an LCQ classic ion trap to conduct selective ion filtration prior to mass analysis in order to extend the dynamic range of the trap. Space charge effects are known to limit the functional ion storage capacity of ion trap mass analyzers and this, in turn, can affect the quality of the mass spectral data generated. This problem is further exacerbated in the analysis of mixtures where the indiscriminate introduction of matrix ions results in premature trap saturation with non-targeted species, thereby reducing the number of parent ions that may be used to conduct MS/MS experiments for quantitation or other diagnostic studies. We show that conducting differential mobility-based separations prior to mass analysis allows the isolation of targeted analytes from electrosprayed mixtures preventing the indiscriminate introduction of matrix ions and premature trap saturation with analytically unrelated species. Coupling these two analytical techniques is shown to enhance the detection of a targeted drug metabolite from a biological matrix. In its capacity as a selective ion filter, the DMS can improve the analytical performance of analyzers such as quadrupole (3D or linear) and ion cyclotron resonance (FT-ICR) ion traps that depend on ion accumulation.
?  相似文献   

20.
Electron transfer dissociation (ETD) has attracted increasing interest due to its complementarity to collision-induced dissociation (CID). ETD allows the direct localization of labile post-translational modifications, which is of main interest in proteomics where differences and similarities between ETD and CID have been widely studied. However, due to the fact that ETD requires precursor ions to carry at least two charges, little is known about differences in ETD and CID of small molecules such as metabolites. In this work, ETD and CID of desmosine (DES) and isodesmosine (IDS), two isomers that due to the presence of a pyridinium group can carry two charges after protonation, are studied and compared. In addition, the influence of DES/IDS derivatization with propionic anhydride and polyethyleneglycol (PEG) reagents on ETD and CID was studied, since this is a common strategy to increase sensitivity and to facilitate the analysis by reversed-phase chromatography. Clear differences between ETD and CID of non-derivatized and derivatized-DES/IDS were observed. While CID is mainly attributable to charge-directed fragmentation, ETD is initiated by the generation of a hydrogen atom at the initial protonation site and its subsequent transfer to the pyridinium ring of DES/IDS. These differences are reflected in the generation of complex CID spectra dominated by the loss of small, noninformative molecules (NH3, CO, H2O), while ETD spectra are simpler and dominated by characteristic side-chain losses. This constitutes a potential advantage of ETD in comparison to CID when employed for the targeted analysis of DES/IDS in biological samples.
Figure
A mechanistic study of electron transfer dissociation (ETD) and collision-induced dissociation (CID) of labeled and free desmosine and isodesmosine provides evidence that CID is mainly due to charge-directed fragmentation while ETD is initiated by the generation of a hydrogen atom at the initial protonation site, and its subsequent transfer to the pyridinium ring.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号