首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 218 毫秒
1.
A new sample preparation and preconcentration technique – solid phase microextraction (SPME) – is reported for the application of several tinorganic compounds and tetrabutyllead in aqueous samples. The solvent-free procedure is rapid in comparison with liquid-liquid extraction or SFE but also sensitive. Analytical variables of the extraction such as adsorption and desorption time, stirring rate and temperature has been investigated. The determination has been performed by GC coupled with atomic emission detection (AED). After optimization of the conditions of SPME a calibration was realized on the basis of a multicomponent standard solution, prepared by ethylation of organotin salts directly in the sample using sodium tetraethylborate (NaBEt4) without prior separation of the analytes from the matrix. The method permits preconcentration. Values of about 10 can be reached. A detection limit of 0.09 pg Sn and 0.08 pg Pb can be achieved under optimized conditions. The proposed procedure has been successfully applied to the analysis of organotin compounds in various slurry samples.  相似文献   

2.
A method for the determination of organotin compounds (monobutyl = MBT, dibutyl = DBT, and tributyltin = TBT) in marine sediments by headspace Solid Phase Microextraction (SPME) has been developed. The analytical procedure involved 1) extraction of TBT, DBT and MBT from sediments with HCl and methanol mixture, 2) in situ derivatization with sodium tetraethylborate and 3) headspace SPME extraction using a fiber coated with poly(dimethylsiloxane). The derivatized organotin compounds were desorbed into the splitless injector and simultaneously analyzed by gas chromatography - mass spectrometry. The analytical method was optimized with respect to derivatization reaction and extraction conditions. The detection limits obtained for MBT, DBT and TBT ranged from 730 to 969 pg/g as Sn dry weight. Linear calibration curves were obtained for all analytes in the range of 30-1000 ng/L as Sn. Analysis of a standard reference sediment (CRM 462) demonstrates the suitability of this method for the determination of butyltin compounds in marine sediments. The application to the determination of TBT, DBT and MBT in a coastal marine sediment is shown.  相似文献   

3.
A method for the determination of organotin compounds (monobutyl = MBT, dibutyl = DBT, and tributyltin = TBT) in marine sediments by headspace Solid Phase Microextraction (SPME) has been developed. The analytical procedure involved 1) extraction of TBT, DBT and MBT from sediments with HCl and methanol mixture, 2) in situ derivatization with sodium tetraethylborate and 3) headspace SPME extraction using a fiber coated with poly(dimethylsiloxane). The derivatized organotin compounds were desorbed into the splitless injector and simultaneously analyzed by gas chromatography – mass spectrometry. The analytical method was optimized with respect to derivatization reaction and extraction conditions. The detection limits obtained for MBT, DBT and TBT ranged from 730 to 969 pg/g as Sn dry weight. Linear calibration curves were obtained for all analytes in the range of 30–1000 ng/L as Sn. Analysis of a standard reference sediment (CRM 462) demonstrates the suitability of this method for the determination of butyltin compounds in marine sediments. The application to the determination of TBT, DBT and MBT in a coastal marine sediment is shown.  相似文献   

4.
Optimal conditions of headspace solid-phase microextraction followed by gas chromatography coupled to pulsed flame photometric detection (SPME–GC–PFPD) have been investigated to validate the analysis of 11 organotin compounds in plant matrices including methyl-, butyl-, and phenyltin compounds. The extraction of organotin compounds from vegetal matrices has been carried out using optimized conditions of HCl-based extraction. The use of headspace SPME to preconcentrate the analytes allowed most of the detection limits to be obtained sub-0.5?ng(Sn)?g?1. The precision evaluated using RSD with six replicates ranges between 5 and 10% (except for triphenyltin: 17%). The accuracy of the method was validated on spiked or polluted vegetal samples taken from Bizerte Lagoon (Tunisia) and by comparison with classical liquid–liquid extraction (LLE). These results highlight the suitability of the selected method for organotin control in complex environmental matrices such as aquatic plants.  相似文献   

5.
A method based on Headspace solid-phase microextraction (HS-SPME, with a 100 μm PDMS-fiber) in combination with gas-chromatography and pulsed flame-photometric detection (GC-PFPD) has been investigated for simultaneous determination of eight organotin compounds. Monobutyltin (MBT), dibutyltin (DBT), tributyltin (TBT), monophenyltin (MPhT), and the semi-volatile diphenyltin (DPhT), triphenyltin (TPhT), monooctyltin (MOcT), and dioctyltin (DOcT) were determined after derivatization with sodium tetraethylborate. The conditions used for the extraction and preconcentration step were optimised by experimental design methodology. Tripropyltin (TPrT) and diheptyltin (DHepT) were used as internal standards for quantification of volatile and semi-volatile organotin compounds, respectively. The analytical precision (RSD) for ten successive injections of a standard mixture containing all the organic tin compounds ranged between 2 and 11%. The limits of detection for all the organotin compounds were sub ng (Sn) L−1 in water and close to ng (Sn) kg−1 in sediments. The accuracy of the method was evaluated by analysis of two certified reference material (CRM) sediment samples. The HS-SPME–GC–PFPD was then applied to the analysis of three harbour sediment samples. The results showed that headspace SPME is an attractive tool for analysis of organotin compounds in solid environmental matrices.  相似文献   

6.
Solid-phase microextraction (SPME) has become a real alternative to liquid-liquid extraction in the field of speciation of organometallic compounds. Despite the high performance of this preconcentration technique, matrix effects in natural samples can affect the analytical precision. In order to understand the origin of these disturbances and control the extraction step as best as possible, the sorption-desorption behaviour of organotins was studied. In the first part, this paper discusses the analytical problems encountered in the daily use of SPME due to the particular problems observed for phenyltins. The sorption profile of these compounds was modelled using experimental design methodology to confirm the first-order kinetics. Desorption of the compounds was also observed after a given time and could not be attributed to competition between organotin compounds. In the same way, butyl- and phenyltins were studied in the presence of humic substances, which acted as representatives of organic matter found in natural samples. These substances drastically decrease the extraction yields, but do not affect the sorption profile of butyl- and phenyltins.  相似文献   

7.
In this study, a new solid-phase microextraction (SPME) method for simultaneous extraction of pharmaceutical compounds with acidic and basic characteristics (ibuprofen, fenoprofen, diclofenac, diazepam and loratadine) from residual water samples is proposed. In this procedure, the extraction is processed using two distinct sample pH values. The extraction is begun at pH 2.5 to promote the sorption of acidic pharmaceuticals and after 35 min the sample pH is changed to 7.0 by adding 0.4 mol L−1 disodium hydrogenphosphate, so that the basic compounds can be sorbed by the fiber (20 min). The pH change is performed without interruption of the extraction process. A comparison between the proposed method and the SPME method applied to each group of the target compounds was performed. Gas chromatography coupled to mass spectrometry was used for separation and detection of analytes. The extraction conditions for the three methods were optimized using full factorial experimental design, response surface through a Doehlert matrix and central composite design. Limits of detection (0.02-0.43 μg L−1) and correlation coefficients (0.9970-0.9998) were determined for the three methods. The proposed extraction procedure was applied to samples of sewage treatment plant effluent and untreated wastewater. Recovery and relative standard deviation values ranged from 67 to 116% and 4.6 to 14.5%, respectively, for all compounds studied. Modification of sample pH during the extraction procedure was shown to be an excellent option for all of the compounds and may be extended to the simultaneous extraction of other compounds with different acid-base characteristics.  相似文献   

8.
Solid-phase microextraction (SPME) is a solvent-free sample preparation technique using a thin coating attached to the surface of a fused silica-fiber as the extraction medium, which has been successfully applied to the analysis of a wide variety of compounds by coupling to gas chromatography (GC). In recent years, in-tube SPME using GC capillary column as the extraction medium has also been developed and coupled with liquid chromatography (LC) for the preconcentration of nonvolatile compounds. In this study, an on-line interface between the fiber-in-tube SPME and capillary electrophoresis (CE) has been developed, and the preconcentration and separation of four tricyclic antidepressant (TCA) drugs, amitriptyline, imipramine, nortriptyline, and desipramine, were performed with the hyphenated system. Under the optimized condition, a better extraction performance than conventional in-tube SPME was obtained, even the length of the extraction medium was much shorter. The results clearly indicated that the fiber was working effectively as an extraction medium. For the separation of these four TCAs, capillary electrophoretic separation with beta-cyclodextrin as the buffer additive has been employed and the application of the developed system to the analysis of complex sample mixtures in a biological matrix is also demonstrated.  相似文献   

9.
 The solid-phase microextraction (SPME) technique coupled with gas chromatography and atomic emission detection was successfully applied for the determination of selected organometallic species of Pb, As and Hg in aqueous samples. To obtain a high extraction yield, the SPME conditions were optimised for each element by fibre selection and varying the exposure time, stirring rate, pH range and desorption time. All the organometallic compounds tested were extracted from the aqueous phase using SPME. The preconcentration factors attained ranged between 40 and 150, depending on the compound. Detection limits in the pg/L and ng/L ranges were achieved. Received January 18, 2000. Revision April 11, 2000.  相似文献   

10.
Speciation of organotin in environmental sediment samples   总被引:1,自引:0,他引:1  
Ceulemans M  Slaets S  Adams F 《Talanta》1998,46(3):395-405
An optimized sample preparation procedure for organotin speciation in sediment samples has been applied to the analysis of sediments collected in the environment. The method is based on tropolone complexation of the ionic organotins, followed by extraction into a hexane-ethylacetate mixture and derivatization by NaBEt(4). The method was applied to the determination of organotin in various harbour, shipyard and dry-dock sediments in Belgium. Butyltin compounds were detected in all samples analyzed, often at high mg kg(-1) levels. A limited number of samples showed the presence of phenyltin compounds. Further, the method was adapted to the analysis of river sediments sampled from the vicinity of shipyards. Butyltin concentrations were detected at the microg kg(-1) level in the majority of samples.  相似文献   

11.
A method for speciation of organotin compounds in marine sediments by solvent extraction combined with hydride generation gas chromatography-atomic absorption spectrometry has been developed. Sediment samples spiked with tributyltin and triphenyltin chlorides were homogenized in hydrochloric acid. The chlorides were extracted twice into toluene. Recoveries of the organotin compounds from the spiked sediment samples were improved by the addition of 8-quinolinol. Tributyltin and triphenyltin chlorides form ion-associates with 8-quinolinol in aqueous hydrochloric acid. The method was optimized with respect to derivatization reactions and extraction conditions. Interferences from Sn(II/IV) and additional 13 ions were investigated. Recoveries of 84-100% for tributyltin and 86-100% for triphenyltin were achieved using this method. The detection limits obtained for tributyltin and triphenyltin chlorides were 95 and 145 pg, respectively, corresponding to a relative detection limit of 95 and 145 ng kg(-1) in the sediment.  相似文献   

12.
A headspace solid-phase micro-extraction (HS-SPME) method was developed and optimized for gas chromatographic separation and determination of commonly found organotin compounds in human urine after potential exposure. Butyl- and phenyltin compounds were in situ derivatized to ethylated derivatives by sodium tetraethylborate (NaBEt4) directly in the urine matrix. The relevant parameters affecting the yield of the SPME procedure were examined using tetrabutyltin as internal standard. The method was optimized for direct use in the analysis of undiluted human urine samples and mono-, di- and tri-substituted butyl- and phenyltin compounds could be determined after a 15-min headspace extraction time at room temperature. The selectivity of the microwave-induced plasma atomic emission detector (MIP-AED) as an element specific detector in combination with the relatively selective sample preparation technique of HS-SPME allowed the interference-free detection of the organotin compounds in all cases. A quadrupole mass spectrometer was used in parallel experiments as a detector for the confirmation of the identity molecular structure of the eluted compounds. The performance characteristics of the developed method are given for the determination of mixtures of these compounds. Finally the proposed method was applied to the analysis of several human urine samples.  相似文献   

13.
In this work, the analysis of a group of four fungicides (pyrimethanil, nuarimol, procymidone and cyprodinil) and one insecticide (pirimicarb) by micellar electrokinetic chromatography (MEKC) with UV detection using the on-line preconcentration strategy called reversed electrode polarity stacking mode (REPSM) is proposed. After optimisation, an adequate separation electrolyte for the separation and stacking of these pesticides was obtained which consisted of 100 mM borate, 60 mM sodium dodecyl sulphate (SDS), at pH 9.0 and 2% 2-propanol. The use of this running buffer together with the REPSM preconcentration method provided limits of detection (LODs) between 38.3 and 241 microg/L. In order to apply the developed methodology for the analysis of these pesticides in wine samples, several off-line preconcentration strategies (mainly, solid-phase extraction, SPE, and solid-phase microextraction, SPME) were tested. Although the use of a SPE procedure, optimized in this work for water samples, using Oasis HLB cartridges, provided mean recovery values between 79 and 100% for spiked water samples, it could not be applied to the extraction of these pesticides from wine samples due to high interference from the sample matrix. However, the use of a SPME procedure using polydimethylsiloxane/divynilbenzene (PDMS/DVB) fibers allowed the selective extraction of four of the five pesticides which could be perfectly determined. The final combination of the off-line SPME and on-line REPSM preconcentration strategies allowed obtaining LODs between 17.6 and 32.3 microg/L.  相似文献   

14.
A solid-phase microextraction method (SPME) coupled to gas chromatography-mass spectrometry (GC-MS) has been developed for the determination of the six phthalate esters included in the US Environmental Protection Agency (EPA) Priority Pollutants list in water samples. These compounds are dimethyl phthalate (DMP), diethyl phthalate (DEP), di-n-butyl phthalate (DBP), butylbenzyl phthalate (BBP), di-2-ethylhexyl phthalate (DEHP) and di-n-octyl phthalate (DOP). Detailed discussion of the different parameters, which could affect the extraction process, is presented. Main factors have been studied and optimized by means of a multifactor categorical design. Different commercial fibers, polydimethylsiloxane (PDMS), polydimethylsiloxane-divinylbenzene (PDMS-DVB), polyacrylate (PA), Carboxen-polydimethylsiloxane (CAR-PDMS) and Carbowax-divinylbenzene (CW-DVB), have been investigated, as well as the extraction mode, exposing the fiber directly into the sample (DSPME) or into the headspace over the sample (HS-SPME), and different extraction temperatures. The use of this experimental design allowed for the evaluation of interactions between factors. Extraction kinetics has also been studied. The optimized microextraction method showed linear response and good precision for all target analytes. Detection limits were estimated considering the contamination problems associated to phthalate analysis. They were in the low pg mL(-1), excluding DEHP (100 pg mL(-1)). The applicability of the developed SPME method was demonstrated for several real water samples including mineral, river, industrial port and sewage water samples. All the target analytes were found in real samples. Levels of DEP and DEHP were over 1 ng mL(-1) in some of the samples.  相似文献   

15.
Because of the high toxicity of organotin compounds and the current regulation about their applications, analytical method usable in routine analysis is required. A speciation procedure based on NaBEt4 ethylation and GC-PFPD analysis has shown to be suitable for the organotin determination. Unfortunately, some matrix effects were observed during the analysis of harbour sediments from Chile. These effects were identified as the alkylation of elemental sulfur and the coelution between the organotin compounds and some dialkylsulfides. The re-optimization of GC parameters and application of solid phase microextraction (SPME) were proposed to solve these analytical problems. Certified reference materials and different harbour sediment samples were analysed in order to evaluate the suitability of the methods for organotin control in complex environment samples.  相似文献   

16.
Different headspace solid-phase microextraction (HS-SPME) methods have been selected and applied to the analysis of volatile compounds in ‘fino’ sherry wine by gas chromatography-mass spectrometry. A method based on rotary and continuous liquid-liquid extraction (LLE) for analysis of these same compounds has been optimised. The best conditions to extract this type of compounds using SPME and LLE were determined and both methods were validated. Both methodologies show adequate detection and quantitation limits, and linear ranges for correctly analysing these compounds. The recoveries obtained were close to 100%, with good repeatability values. The analytical and procedural advantages and disadvantages of these two methods have been compared. In general, SPME presented higher sensitivities. Both analytical methods were used to analyse five samples of ‘fino’ sherry wine supplied by different producers. No significant differences were found between the techniques at a significance level of 5%. The regression coefficients (r2) for analysis using LLE and SPME exceeded 0.94 for all compounds. The LLE procedure is a method with high repeatability and has the possibility of simultaneous extraction of several samples (up to 12), however the SPME technique is a solvent-free method presenting major advantages, such as small sample volume and higher sensitivity and simplicity.  相似文献   

17.
The growing concern about the fate of organotin in the environment created an imperative need for the development of faster, more sensitive and reliable methods for speciation analysis of organotin compounds. A novel method has been developed in our laboratory for the extraction and determination of butyltin species in water by solid phase microextraction (SPME) combined with capillary gas chromatography-flame photometric detector(GC-FPD).  相似文献   

18.
A novel "fiber-in-tube" configuration has been applied to the extraction tube of solid phase microextraction (SPME), and the direct coupling of the extraction process to liquid chromatography (LC) has been accomplished for the analysis of n-butylphthalate in wastewater. By using this fiber-in-tube SPME/LC system the preconcentration factor for the phthalate was about 160 with 20 min extraction and no interference peak was observed in the chromatogram. The results also showed the potential applications of this fiber-in-tube SPME/LC for the analysis of sub-ppb level (i.e., lower than 1 ng/mL) of various organic analytes in aqueous sample matrix without a large solvent consumption during the preconcentration process.  相似文献   

19.
A fiber coating from polyaniline (PANI) was electrochemically prepared and employed for solid phase microextraction (SPME) of some polycyclic aromatic hydrocarbons (PAHs) from water samples. The PANI film was directly electrodeposited on the platinum wire surface in sulfuric acid solution using cyclic voltammetry (CV) technique. The applicability of this coating was assessed employing a laboratory-made SPME device and gas chromatography with mass spectrometry (GC-MS) for the extraction of some PAHs from the headspace of aqueous samples. Application of wider potential range in CV led to a PANI with more stability against the temperature. The homogeneity and the porous surface structure of the film were examined by the scanning electron microscopy (SEM). The study revealed that this polymer is a suitable SPME fiber coating for extracting the selected PAHs. Important parameters influencing the extraction process were optimized and an extraction time of 40 min at 40 degrees C gave maximum peak area, when the aqueous sample was added with NaCl (20%, w/v). The synthesis of the PANI can be carried out conveniently and in a reproducible manner while it is rather inexpensive and stable against most of organic solvents. The film thickness of PANI can be precisely controlled by the number of CV cycles. The resulting thickness was roughly 20 microm after 20 cycles. At the optimum conditions, the relative standard deviation (RSD) for a double distilled water spiked with selected PAHs at ppb level were 8.80-16.8% (n = 3) and detection limits for the studied compounds were between 0.1-6 pg mL(-1). The performance of PANI was, also, compared with a commercial solid coated-based SPME fiber, carbowax/divinylbenzene (CW/DVB), under similar experimental conditions.  相似文献   

20.
The simultaneous extraction of acidic and basic pollutants from water samples is an interesting and debatable work in sample preparation techniques. A novel and efficient method named ion pair based surfactant assisted microextraction (IP-SAME) was applied for extraction and preconcentration of five selected acidic and basic aromatic species as model compounds in water samples, followed by high performance liquid chromatography-ultraviolet detection. A mixture including 1 mL of ultra-pure water (containing ionic surfactant as emulsifier agent) and 60 μL 1-octanol (as extraction solvent) was rapidly injected using a syringe into a 10.0 mL water sample which formed an emulsified solution. IP-SAME mechanism can be interpreted by two types of molecular mass transfer into the organic solvent (partitioning and ion pairing for non-ionized and ionized compounds, respectively) during emulsification process. The effective parameters on the extraction efficiency such as the extraction solvent type and its volume, type of the surfactant and its concentration, sample pH and ionic strength of the sample were optimized. Under the optimum conditions (60 μL of 1-octanol; 1.5 mmol L(-1) cethyltrimethyl ammonium bromide (CTAB) as emulsifier agent and sample pH 10.0), the preconcentration factors (PFs), detection limits and linear dynamic ranges (LDRs) were obtained in the range of 87-348, 0.07-0.6 μg L(-1) and 0.1-200 μg L(-1) respectively. All of natural water samples were successfully analyzed by the proposed method.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号