首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The highly diverse chemical structures of lipids make their analysis directly from biological tissue sections extremely challenging. Here, we report the in situ mapping and identification of lipids in a freshwater crustacean Gammarus fossarum using matrix‐assisted laser desorption/ionization (MALDI) mass spectrometry imaging (MSI) in combination with an additional separation dimension using ion mobility spectrometry (IMS). The high‐resolution trapped ion mobility spectrometry (TIMS) allowed efficient separation of isobaric/isomeric lipids showing distinct spatial distributions. The structures of the lipids were further characterized by MS/MS analysis. It is demonstrated that MALDI MSI with mobility separation is a powerful tool for distinguishing and localizing isobaric/isomeric lipids.  相似文献   

2.
Mass spectrometry imaging (MSI) is a comprehensive tool for the analysis of a wide range of biomolecules. The mainstream method for molecular MSI is matrix‐assisted laser desorption ionization, however, the presence of a matrix results in spectral interferences and the suppression of some analyte ions. Herein we demonstrate a new matrix‐free MSI technique using nanophotonic ionization based on laser desorption ionization (LDI) from a highly uniform silicon nanopost array (NAPA). In mouse brain and kidney tissue sections, the distributions of over 80 putatively annotated molecular species are determined with 40 μm spatial resolution. Furthermore, NAPA‐LDI‐MS is used to selectively analyze metabolites and lipids from sparsely distributed algal cells and the lamellipodia of human hepatocytes. Our results open the door for matrix‐free MSI of tissue sections and small cell populations by nanophotonic ionization.  相似文献   

3.
OrbiSIMS is a recently developed instrument for label‐free imaging of chemicals with micron spatial resolution and high mass resolution. We report a cryogenic workflow for OrbiSIMS (Cryo‐OrbiSIMS) that improves chemical detection of lipids and other biomolecules in tissues. Cryo‐OrbiSIMS boosts ionization yield and decreases ion‐beam induced fragmentation, greatly improving the detection of biomolecules such as triacylglycerides. It also increases chemical coverage to include molecules with intermediate or high vapor pressures, such as free fatty acids and semi‐volatile organic compounds (SVOCs). We find that Cryo‐OrbiSIMS reveals the hitherto unknown localization patterns of SVOCs with high spatial and chemical resolution in diverse plant, animal, and human tissues. We also show that Cryo‐OrbiSIMS can be combined with genetic analysis to identify enzymes regulating SVOC metabolism. Cryo‐OrbiSIMS is applicable to high resolution imaging of a wide variety of non‐volatile and semi‐volatile molecules across many areas of biomedicine.  相似文献   

4.
Paper spray ionization (PSI) is an extractive ambient ionization technique for mass spectrometry (MS), whereby a triangular paper tip serves as the sampling base and the electrospray tip. During PSI, analytes are extracted and transported to the edge of the paper tip by the applied spraying solvent. Analytes can be purified from a sample matrix and separated from each other by this transportation process. In this study, we investigated and utilized the analyte transportation process of PSI for the in situ separation and analysis of lipid mixtures. We found that differential transport of phosphatidylcholine (PC) and triacylglycerol (TAG), the two most abundant lipid classes in animals, occurred during PSI. We also found that the order in which these lipids moved strongly depended on how the spraying solvent was applied to the paper base. The more polar PC moved faster than the less polar TAG during PSI, when a polar solvent was slowly fed into a paper tip, whereas TAG was transported faster than PC when excess solvent was applied to the tip at once. In addition, we achieved a complete separation and detection of PC and TAG by slowly supplying a nonpolar solvent to a PSI tip.  相似文献   

5.
OrbiSIMS is a recently developed instrument for label-free imaging of chemicals with micron spatial resolution and high mass resolution. We report a cryogenic workflow for OrbiSIMS (Cryo-OrbiSIMS) that improves chemical detection of lipids and other biomolecules in tissues. Cryo-OrbiSIMS boosts ionization yield and decreases ion-beam induced fragmentation, greatly improving the detection of biomolecules such as triacylglycerides. It also increases chemical coverage to include molecules with intermediate or high vapor pressures, such as free fatty acids and semi-volatile organic compounds (SVOCs). We find that Cryo-OrbiSIMS reveals the hitherto unknown localization patterns of SVOCs with high spatial and chemical resolution in diverse plant, animal, and human tissues. We also show that Cryo-OrbiSIMS can be combined with genetic analysis to identify enzymes regulating SVOC metabolism. Cryo-OrbiSIMS is applicable to high resolution imaging of a wide variety of non-volatile and semi-volatile molecules across many areas of biomedicine.  相似文献   

6.
A combination of methodologies using the extremely high mass accuracy and resolution of 15‐T Fourier transform ion cyclotron resonance (FT‐ICR) mass spectrometry (MS) was introduced for the identification of intact cancer cell phospholipids. Lipids from a malignant glioma cell line were initially analyzed at a resolution of >200 000 and identified by setting the mass tolerance to ±1 mDa using matrix‐assisted laser desorption/ionization (MALDI) 15‐T FT‐ICR MS in positive ion mode. In most cases, a database search of potential lipid candidates using the exact masses of the lipids yielded only one possible chemical composition. Extremely high mass accuracy (<0.1 ppm) was then attained by using previously identified lipids as internal standards. This, combined with an extremely high resolution (>800 000), yielded well‐resolved isotopic fine structures allowing for the identification of lipids by MALDI 15‐T FT‐ICR MS without using tandem mass spectrometric (MS/MS) analysis. Using this method, a total of 38 unique lipids were successfully identified. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

7.
Mass spectrometry imaging (MSI) is a powerful tool that has advanced our understanding of complex biological processes by enabling unprecedented details of metabolic biology to be uncovered. Through the use of high‐spatial resolution MSI, metabolite localizations can be obtained with high precision. Here we describe our recent progress to enhance the spatial resolution of matrix‐assisted laser desorption/ionization (MALDI) MSI from ∼50 μm with the commercial configuration to ∼5 μm. Additionally, we describe our efforts to develop a ‘multiplex MSI’ data acquisition method to allow more chemical information to be obtained on a single tissue in a single instrument run, and the development of new matrices to improve the ionization efficiency for a variety of small molecule metabolites. In combination, these contributions, along with the efforts of others, will bring MSI experiments closer to achieving metabolomic scale.  相似文献   

8.
流动注射-电感耦合等离子体质谱法的基体效应   总被引:6,自引:0,他引:6  
曹淑琴  陈杭亭  曾宪津  王东平 《分析化学》2000,28(12):1476-1480
研究了流动注射小体积进样,电感耦合等离子体质谱法的在体效应,并与连续进样作了比较,流动注射小体积(100μL)进样时,电离电位较高的As和Au基体对分析元素的信号表现为增强效应,分析元素的质量数越大,所受增强效应越小。了电位较低的Cu、In、Li、Na和Pb基体对分析元素的信号则表为抑制效应,基体元素的质量数越大,对分析元素的抑制效应也越大;质量数较大的分析元素,所受的抑制效应较;对质量数相近的分析元素,电离电位较高者受的抑制较大,与连续进样相比,流动注射小体积进样时,基体元素对分析元素的抑制效应较弱,而增强效应较强。  相似文献   

9.
Time-of-flight secondary ion mass spectrometry (ToF-SIMS) is used for chemical analysis of surfaces. ToF-SIMS is a powerful tool for polymer science because it detects a broad mass range with good mass resolution, thereby distinguishing between polymers that have similar elemental compositions and/or the same types of functional groups. Chemical labeling techniques that enhance contrast, such as deuterating or staining one constituent, are generally unnecessary. ToF-SIMS can generate both two-dimensional images and three-dimensional depth profiles, where each pixel in an image is associated with a complete mass spectrum. This Review begins by introducing the principles of ToF-SIMS measurements, including instrumentation, modes of operation, strategies for data analysis, and strengths/limitations when characterizing polymer surfaces. The sections that follow describe applications in polymer science that benefit from characterization by ToF-SIMS, including thin films and coatings, polymer blends, composites, and electronic materials. The examples selected for discussion showcase the three standard modes of operation (spectral analysis, imaging, and depth profiling) and highlight practical considerations that relate to experimental design and data processing. We conclude with brief comments about broader opportunities for ToF-SIMS in polymer science.  相似文献   

10.
A chemical characterization of major lipid components, namely, triacylglycerols, fatty acids and the unsaponifiable fraction, in a Quinoa seed lipids sample is reported. To tackle such a task, non‐aqueous reversed‐phase high‐performance liquid chromatography with mass spectrometry detection was employed. The latter was interfaced with atmospheric pressure chemical ionization for the analysis of triacylglycerols. The main triacylglycerols (>10%) were represented by OLP, OOL and OLL (P = palmitoyl, O = oleoyl, L = linoleoyl); the latter was present in the oil sample at the highest percentage (18.1%). Furthermore, fatty acid methyl esters were evaluated by gas chromatography with flame ionization detection. 89% of the total fatty acids was represented by unsaturated fatty acid methyl esters with the greatest percentage represented by linoleic and oleic acids accounting for approximately 48 and 28%, respectively. An extensive characterization of the unsaponifiable fraction of Quinoa seed lipids was performed for the first time, by using comprehensive two‐dimensional gas chromatography with dual mass spectrometry/flame ionization detection. Overall, 66 compounds of the unsaponifiable fraction were tentatively identified, many constituents of which (particularly sterols) were confirmed by using gas chromatography with high‐resolution time‐of‐flight mass spectrometry.  相似文献   

11.
微流控芯片与质谱联用为细胞研究提供了一个很好的研究平台.质谱的高灵敏度和对化合物独特的鉴别能力可以从复杂的化学信息背景中筛选识别出微量目标物,是细胞分析理想的检测手段.本文重点综述了近年来基于微流控芯片-质谱联用技术的细胞研究进展,从芯片-电喷雾质谱(ESI-MS)接口技术、集成化的样品前处理技术、细胞的药物代谢和细胞相互作用研究及基质辅助激光解吸电离质谱(MALDI-MS)的细胞分析应用等方面总结了最新的方法和技术发展.并展望了芯片-质谱联用新技术应用于细胞分析的可能性.  相似文献   

12.
磷脂是所有生物细胞膜的主要成分,在许多生命活动过程中具有重要的功能。但由于生物样本中的磷脂种类繁多,含量极低,存在基质抑制效应,且结构中缺少易电离的官能团,从而导致对磷脂的定性和定量分析较困难。利用化学衍生化技术对其进行结构修饰可以提高离子化效率、改善色谱分离度且提高质谱(MS)检测的灵敏度和选择性。MS与衍生化方法结合已被广泛用于蛋白组学、糖组学、代谢物等的分析。近年来,这一策略逐渐被应用于脂质组学的分析研究。该文综述了国内外近10年基于衍生化技术的甘油磷脂分析方法及其应用研究进展,以激发衍生化技术在脂质组学分析中的应用潜能。  相似文献   

13.
With the implementation of focused primary ion beams, secondary ion mass spectrometry (SIMS) has become a significant technique in the rapidly emerging field of mass spectral imaging in the biological sciences. Liquid metal ion guns (LMIG) offered the prospect of sub-100 nm spatial resolution, however this aspiration has yet to be reached for molecular imaging. This brief review shows that using LMIG the limitations of the static limit and low ionization probability will restrict useful imaging to around 2 μm spatial resolution with high-yield molecules. The only prospect of going beyond this in the absence of factors of 100 increase in ionization probability is to use polyatomic ion beams such as C60+, for which bombardment induced damage is low. In these cases sub-micron imaging becomes possible, using voxels together with molecular depth profiling and 3D imaging. The discussion shows that conventional ToF-SIMS instrumentation then becomes a limitation in that the pulsed ion beam has a very low duty cycle which results in inordinately long analysis times, and pulsing the beam means that high-mass resolution and high spatial resolution are mutually incompatible. New instrumental configurations are described that allow the use of a dc ion beam and separate the mass spectrometry for the ion formation process. Early results from these instruments suggest that sub-micron analysis and imaging with high mass resolution and good ion yields are now realizable, although the low ion yield issue still needs to be solved.  相似文献   

14.
内源性代谢物是机体生命活动的中间体和终产物,对其进行定性和定量分析在生命科学研究中具有重要意义.质谱能够同时提供化合物的定性和定量信息,已经成为一种通用的内源性代谢物分析技术.由于质谱是通过检测离子质荷比获取化合物组成信息,区分生物体内复杂多样代谢物同分异构体仍然是质谱分析亟待解决的难题之一.化学衍生通过放大同分异构体...  相似文献   

15.
Cho IH  Park JW  Lee TG  Lee H  Paek SH 《The Analyst》2011,136(7):1412-1419
The molecular orientation of antibody layers formed on separate solid matrices (e.g., gold-coated glass substrate) was characterized by means of time-of-flight secondary ion mass spectrometry (ToF-SIMS) in static mode. For comparison, three different antibody species, IgG, F(ab')(2), and Fab, were prepared, biotinylated in random and site-directed fashions, and immobilized on distinct streptavidin-coated surfaces. ToF-SIMS analyses of each antibody layer revealed that the secondary ion intensity peaks measured at the mass-to-charge (m/z) ratio 253, 325, and 647 were unique to the site-directly immobilized antibodies. The ions in the three peaks were detected neither from the streptavidin layer nor from the randomly prepared antibody, indicating that the insolubilized antibody layers constructed in the two different manners had distinct molecular arrangements. The antibody preparations were further tested for their binding characteristics in sandwich-type immunoassays, which showed that the site-directed antibodies consistently enhanced the detection capability comparing to those randomly prepared. Based on the analytical results of both the ToF-SIMS analysis and sandwich-type immunoassays, the site-directed antibody species were immobilized on the surfaces in a more orientated manner, with their antigen binding sites exposed to the bulk solution, than when random immobilization was used.  相似文献   

16.
The specific matrix used in matrix‐assisted laser desorption/ionization imaging mass spectrometry (MALDI IMS) can have an effect on the molecules ionized from a tissue sample. The sensitivity for distinct classes of biomolecules can vary when employing different MALDI matrices. Here, we compare the intensities of various lipid subclasses measured by Fourier transform ion cyclotron resonance (FT‐ICR) IMS of murine liver tissue when using 9‐aminoacridine (9AA), 5‐chloro‐2‐mercaptobenzothiazole (CMBT), 1,5‐diaminonaphthalene (DAN), 2,5‐Dihydroxyacetophenone (DHA), and 2,5‐dihydroxybenzoic acid (DHB). Principal component analysis and receiver operating characteristic curve analysis revealed significant matrix effects on the relative signal intensities observed for different lipid subclasses and adducts. Comparison of spectral profiles and quantitative assessment of the number and intensity of species from each lipid subclass showed that each matrix produces unique lipid signals. In positive ion mode, matrix application methods played a role in the MALDI analysis for different cationic species. Comparisons of different methods for the application of DHA showed a significant increase in the intensity of sodiated and potassiated analytes when using an aerosol sprayer. In negative ion mode, lipid profiles generated using DAN were significantly different than all other matrices tested. This difference was found to be driven by modification of phosphatidylcholines during ionization that enables them to be detected in negative ion mode. These modified phosphatidylcholines are isomeric with common phosphatidylethanolamines confounding MALDI IMS analysis when using DAN. These results show an experimental basis of MALDI analyses when analyzing lipids from tissue and allow for more informed selection of MALDI matrices when performing lipid IMS experiments.  相似文献   

17.
In this report, we describe the visible-laser desorption/ionization of biomolecules deposited on gold-coated porous silicon and gold nanorod arrays. The porous silicon made by electrochemical etching was coated with gold using argon ion sputtering. The gold nanorod arrays were fabricated by electrodepositing gold onto a porous alumina template, and the subsequent partial removal of the alumina template. A frequency-doubled/tripled Nd : YAG laser was used to irradiate the gold nanostructured substrate, and the desorbed molecular ions were mass-analyzed by a time-of-flight mass spectrometer. The desorption/ionization of biomolecules for both substrates was favored by the use of the 532-nm visible-laser, which is in the range of the localized surface plasmon resonance of the gold nanostructure. The present technique offers a potential analytical method for low-molecular-weight analytes that are rather difficult to handle in the conventional matrix-assisted laser desorption/ionization (MALDI) mass spectrometry.  相似文献   

18.
Matrix-free laser desorption/ionization was studied on two-layered sample plates consisting of a substrate and a thin film coating. The effect of the substrate material was studied by depositing thin films of amorphous silicon on top of silicon, silica, polymeric photoresist SU-8, and an inorganic-organic hybrid. Des-arg9-bradykinin signal intensity was used to evaluate the sample plates. Silica and hybrid substrates were found to give superior signals compared with silicon and SU-8 because of thermal insulation and compatibility with amorphous silicon deposition process. The effect of surface topography was studied by growing amorphous silicon on hybrid micro- and nanostructures, as well as planar hybrid. Compared with planar sample plates, micro- and nanostructures gave weaker and stronger signals, respectively. Different coating materials were tested by growing different thin film coatings on the same substrate. Good signals were obtained from titania and amorphous silicon coated sample plates, but not from alumina coated, silicon nitride coated, or uncoated sample plates. Overall, the strongest signals were obtained from oxygen plasma treated and amorphous silicon coated inorganic-organic hybrid, which was tested for peptide-, protein-, and drug molecule analysis. Peptides and drugs were analyzed with little interference at low masses, subfemtomole detection levels were achieved for des-arg9-bradykinin, and the sample plates were also suitable for ionization of small proteins.  相似文献   

19.
The review discusses the pitfalls of the matrix effect in mass spectrometry detection hyphenated to liquid chromatography separation. Matrix effect heavily influences both qualitative and quantitative analyses, giving rise to suppression or enhancement of the signal. As generally recognised, the predominant cause is the presence of undesired components that co-elute in the chromatographic separation and alter the ionisation process. The interfering species can be components of the sample, compounds released during the pre-treatment/extraction process or reagents added to the mobile phase to improve chromatographic resolution. The different mechanisms proposed in literature to explain the suppression or the enhancement of the signal both in electrospray and atmospheric pressure chemical ionisations are presented and the results observed in the different experimental conditions are compared and discussed. All data together lead to conclude that the chemical properties of the target analyte, the kind of matrix, the matrix to analyte concentration ratio, the extraction process, the chromatographic conditions as well as the kind of the mass spectrometry instrumentation and the ionisation conditions can play a role. Likely all these potential causes act in a synergic way and the final effect observed is hardly due to only one of them. Depending on an unpredictable combination of conditions, signal suppression or enhancement can be observed. The review discusses the matrix effects observed in HPLC–MS and HPLC–MS/MS analysis proposes hypotheses to explain the observed behaviours and proposes methods and strategies to overcome the matrix effects.  相似文献   

20.
In mass spectrometry imaging (MSI) applications of infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI), an exogenous ice layer is the gold standard for an energy-absorbing matrix. However, the formation of the ice matrix requires additional time and instrument hardware, so glycerol was investigated herein as an alternative to the ice matrix to potentially improve spatial resolution and ionization, while decreasing experiment time. Glycerol solutions of varying concentrations were sprayed over top of rat liver tissue sections for analysis by IR-MALDESI and compared to the typical ice matrix condition. Additionally, we tested if combining the ice matrix and glycerol matrix would further improve analyses. Matrix conditions were evaluated by comparing ion abundance of six lipid species, the laser ablation spot diameter, and number of METASPACE annotations. The ion abundances were also normalized to the volume of tissue ablated to correct for lower abundance values due to less ablated tissue. It was observed that utilizing a 50% glycerol matrix without ice provides improved spatial resolution with lipid abundances and annotations comparable to the ice matrix standard, while decreasing the time required to complete an IR-MALDESI tissue imaging experiment.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号