首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
报道了应用X射线荧光光谱技术在中国本土获得的普通人群原位人体活体骨铅数据,发表了中国大陆普通居民的胫骨和根骨活体骨铅浓度及其研究结果。采用Pb的K系谱线进行了原位活体分析人胫骨和根骨骨铅含量。普通人群样本中所测骨铅含量加权平均值在0.4~22.7μg.(g骨矿物质)-1之间,不确定度在7.0~12.5μg.(g骨矿物质)-1之间,平均最小检出限20.3μg.(g骨矿物质)-1。在污染调查区居民中发现骨铅最高可达73.9μg.(g骨矿物质)-1。  相似文献   

2.
In vivo measurement of T2 relaxation times in multiple sclerosis (MS) lesions by magnetic resonance imaging (MRI) is potentially useful for the evaluation of the disease activity. Seven patients with definite MS were investigated over a period of three years (19 examinations), using a whole-body MRI scanner operating at 0.15 T with a specially designed high-power radio-frequency head coil. A modified CPMG sequence with a 180 degree pulse interval of TE = 6 msec and 128 echoes was used for the T2 relaxation measurement of the areas of increased signal (AIS) and white matter (WM). A biexponential T2 analysis of each pixel of the spin-echo images was computed. The T2 relaxation processes were found to be a monoexponential function in WM. The T2 relaxation times of apparently normal white matter in MS patients was significantly longer than in control subjects. The T2 relaxation curves of the AIS were found in most cases to fit a biexponential function characterized by a short and a long T2. T2 long relaxation times of AIS were spread out over a wide range (150-560 msec). The study of T2 long histograms shows that some AIS can be divided into two or three parts depending on the T2 long values. Each of these parts may correspond to a pathological process such as edema, demyelination and gliosis. Evolution of T2 relaxation times over a period of time cannot as yet be correlated with modifications in the clinical state.  相似文献   

3.
Region-selected intensity determination (RSID) is a method for obtaining the temporal changes in electron paramagnetic resonance (EPR) signal intensity from a target region, without the use of complicated procedures employed in the conventional imaging methods. An in vivo 700-MHz radio frequency EPR spectrometer equipped with a bridged loop-gap resonator was used with the RSID method to estimate intracerebral reducing ability in the rat following acute administration of olanzapine (OZP) or haloperidol (HPD). To this end, temporal changes in EPR signal intensity of target regions (the striatum and the prefrontal cortex) of rats which had received a blood-brain-barrier-permeable nitroxide radical (3-hydroxymethyl-2,2,5,5-tetramethylpyrrolidine-1-oxyl) via an intravenous route were observed. The half-lives of EPR signal intensity in both regions of OZP- or HPD-treated rats were significantly longer than in control animals. This indicated that reducing abilities of the striatum and cerebral cortex decreased in the rats to which either OZP or HPD had been acutely administered.  相似文献   

4.
In vivo natural-abundance17O and1H magnetic resonance imaging (MRI) techniques were combined to image the whole body of a rhesus monkey. The results demonstrate the feasibility of acquiring consecutive fast17O and1H images with a standard MRI scanner. The method has applications in the field of functional MRI and in17O MRI measurements of metabolism rate.  相似文献   

5.
A phase-insensitive pulse sequence serving the volume-selective editing of resonances in biomedical NMR spectroscopy is described. The editing principle is the temporary transfer of polarization of the spins to be detected to other species coupled to them. The technique is of particular interest for the localized detection of the lactate methyl proton line while spoiling coherences of uncoupled as well as coupled lipid nuclei otherwise overlapping the lactate resonance. The whole line-editing and coherence-spoiling procedure takes place completely in each scan of any accumulation or phase-cycling series. Phantom studies were carried out with an experimental 4.7 T system. The technique was also tested with volunteers in whole-body tomographs operating at 2 and 3 T. Comparative spectra are presented. It is concluded that editing is crucial for the reliable determination of lactate in muscle and in brain.  相似文献   

6.
OBJECTIVE: The objective of this study was to use magnetic resonance imaging (MRI) to detect the time when and the location at which orally delivered mucoadhesive drugs are released. MATERIALS AND METHODS: Drug delivery systems comprising tablets or capsules containing a mucoadhesive polymer were designed to deliver the polymer to the intestine in dry powder form. Dry Gd-DTPA [diethylenetriaminepentaacetic acid gadolinium(III) dihydrogen salt hydrate] powder was added to the mucoadhesive polymer, resulting in a susceptibility artifact that allows tracking of the application forms before their disintegration and that gives a strong positive signal on disintegration. Experiments were performed with rats using T(1)-weighted spin-echo imaging on a standard 1.5-T MRI system. RESULTS: The susceptibility artifact produced by the dry Gd-DTPA powder in tablets or capsules was clearly visible within the stomach of the rats and could be followed during movement towards the intestine. Upon disintegration, a strong positive signal was unambiguously observed. The time between ingestion and observation of a positive signal was significantly different for different application forms. Quantification of the remaining mucoadhesive polymer in the intestine 3 h after observed release showed significant differences in mucoadhesive effectiveness. CONCLUSION: MRI allows detection of the exact time of release of the mucoadhesive polymer in vivo, which is a prerequisite for a reliable quantitative comparison between different application forms.  相似文献   

7.
In vivo NMR techniques are currently well established in pharmaceutical research and will likely become increasingly important in the future, as they procure noninvasively morphological, physiological, and biochemical information. The status of magnetic resonance imaging (MRI) and spectroscopy (MRS) in drug development is discussed on the basis of the characterization and evaluation of a rat model of ischemic stroke and the development and profiling of drugs for cerebral ischemia in this model. It can be concluded that MRI is well suited for drug screening (quantitative determination of lesion size), while dynamic MRI and MRS techniques provide relevant information on the mechanism of drug actions. The possibility to follow changes, pathological and therapeutic, in the same individual is important from two points of view. First, variations due to interindividual differences may be eliminated, increasing the statistical power of the results. Second, dose and/or time dependence of a drug can be explored in the same individual. As a result, the number of animals required for a study will be reduced, which from both ethical and economic aspects is highly desirable.  相似文献   

8.
By using a narrow single electron spin resonance (ESR) line agent, triarylmethyl, tris(8-carboxy-2,2,6,6-tetrahydroxyethylbenzo[1,2-d:4,5-d′] bis(1,3)dithiole-4-yl)methyl sodium salt (TAM OX063), pulsed longitudinally detected ESR (LODESR) measurements of a phantom or the chest of a living mouse at the operating frequency of ca. 300 MHz were taken and the effective longitudinal relaxation time (T 1*) was estimated for oximetry. Under irradiation of a pair of π-pulses with a variable interval between pulses (τ), in-phase LODESR signal intensities were obtained from the phantoms containing TAM dissolved in a physiological saline solution at a concentration of 1 mM and various concentrations of oxygen. TheT 1* of the phantom was calculated from the plotted curve of the LODESR signal intensity against τ. It was found that the reciprocal ofT 1*, i.e., the longitudinal relaxation rate, increased with the concentration of oxygen. In vivo pulsed LODESR measurements of the chest of living mice that had received a TAM injection via the intraperitoneal route were made. While the LODESR measurements were being made, the mice in one group breathed normal air and those in another group breathed 100% oxygen. It was found that the longitudinal relaxation rate of the mice breathing 100% oxygen was significantly greater than that of mice breathing normal air, indicating that breathing 100% oxygen elevates the thoracic longitudinal relaxation rate.  相似文献   

9.
Experimental gliomas (F98) were inoculated in cat brain for the systematic study of their in vivo T2 relaxation time behavior. With a CPMG multi-echo imaging sequence, a train of 16 echoes was evaluated to obtain the transverse relaxation time and the magnetization M(0) at time t = 0. The magnetization decay curves were analyzed for biexponentiality. All tissues showed monoexponential T2, only that of the ventricular fluid and part of the vital tumor tissue were biexponential. Based on these NMR relaxation parameters the tissues were characterized, their correct assignment being assured by comparison with histological slices. T2 of normal grey and white matter was 74 ± 6 and 72 ± 6 msec, respectively. These two tissue types were distinguished through M(0) which for white matter was only 0.88 of the intensity of grey matter in full agreement with water content, determined from tissue specimens. At the time of maximal tumor growth and edema spread a tissue differentiation was possible in NMR relaxation parameter images. Separation of the three tissue groups of normal tissue, tumor and edema was based on T2 with T2(normal) < T2(tumor) < T2(edema). Using M(0) as a second parameter the differentiation was supported, in particular between white matter and tumor or edema. Animals were studied at 1–4 wk after tumor implantation to study tumor development. The magnetization M(0) of both tumor and peritumoral edema went through a maximum between the second and third week of tumor growth. T2 of edema was maximal at the same time with 133 ± 4 msec, while the relaxation time of tumor continued to increase during the whole growth period, reaching values of 114 ± 12 msec at the fourth week. Thus, a complete characterization of pathological tissues with NMR relaxometry must include a detailed study of the developmental changes of these tissues to assure correct experimental conditions for the goal of optimal contrast between normal and pathological regions in the NMR images.  相似文献   

10.
In preclinical research, genetic studies have made considerable progress as a result of the development of transgenic animal models of human diseases. Consequently, there is now a need for higher resolution MRI to provide finer details for studies of small animals (rats, mice) or very small animals (insects). One way to address this issue is to work with high-magnetic-field spectrometers (dedicated to small animal imaging) with strong magnetic field gradients. It is also necessary to develop a complete methodology (transmit/receive coil, pulse sequence, fixing system, air supply, anesthesia capabilities, etc.). In this study, we developed noninvasive protocols, both in vitro and in vivo (from coil construction to image generation), for drosophila MRI at 9.4 T. The 10*10*80-μm resolution makes it possible to visualize whole drosophila (head, thorax, abdomen) and internal organs (ovaries, longitudinal and transverse muscles, bowel, proboscis, antennae and optical lobes). We also provide some results obtained with a Drosophila model of muscle degeneration. This opens the way for new applications of structural genetic modification studies using MRI of drosophila.  相似文献   

11.
Song KH  Stoica G  Wang LV 《Optics letters》2006,31(16):2453-2455
An in vivo photoacoustic imaging system was designed and implemented to image the entire small animal head. A special scanning gantry was designed to enable in vivo imaging in coronal cross sections with high contrast and good spatial resolution for the first time to our knowledge. By use of a 2.25 MHz ultrasonic transducer with a 6 mm diameter active element, an in-plane radial resolution of approximately 312 microm was achieved. Deeply seated arterial and venous vessels in the head measuring up to 1.7 cm in diameter were simultaneously imaged in vivo with 804 nm wavelength laser excitation of photoacoustic waves.  相似文献   

12.
We propose a method to determine the nonlinearity parameter B/A of a liquid from the spatial evolution of harmonic components. We describe an analytical model, in the parabolic and quasi-linear approximations, that predicts the continuous finite amplitude sound beam propagation radiated by a plane piston source. This model takes into consideration attenuation, diffraction and nonlinear effects. The fundamental and second harmonic ultrasonic fields are expressed as the superposition of Gaussian beams. Axial propagation curves are then compared with those obtained by direct numerical solution of the transformed beam equation using the finite difference method, and with experimental results. Accurate measurements of pressure levels for the nonlinearly generated harmonics in water are performed along and across the propagation axis for different pressure values delivered at the piston surface. Experimental results, for water and ethanol, are in agreement with those of our model, which allows us to obtain the expected value of the nonlinearity parameter B/A.  相似文献   

13.
Chen H  Cui S  Tu Z  Gu Y  Chi X 《Journal of fluorescence》2012,22(2):699-706
CdHgTe/SiO2 nanoparticles were prepared by SiO2 capping on the surface of CdHgTe QDs. The characteristics, such as optical spectra, photostability, size and cell toxicity were investigated. The dynamic distribution of CdHgTe/SiO2 nanoparticles was in vivo monitored by near infrared fluorescence imaging system. CdHgTe/SiO2 nanoparticles acted as a novel fluorescence probe have a maximum fluorescence emission of 785 nm and high photo-stability. The hydrodynamic diameter of CdHgTe/SiO2 nanoparticles could be adjusted to 122.3 nm. Compared to CdHgTe QDs, inhibitory effects of CdHgTe/SiO2 nanoparticles on proliferation of HCT116 cells decreased to a certain extent. CdHgTe/SiO2 nanoparticles had their specific dynamic distribution behavior, which provided new perspectives for bio-distribution of nanoparticles.  相似文献   

14.
Photoacoustic ophthalmoscopy(PAOM) is a novel imaging modality, which is capable of non-invasively detecting optical absorption properties in the retina. We visualize the microvasculature in retina and choroid in albino mouse using PAOM guided by spectral-domain optical coherence tomography. Since albino mouse characterizes by lacking melanin in retinal pigment epithelium(RPE), PAOM illumination laser can penetrate through the RPE onto choroid, and consequently provides volumetric visualization of chorioretinal vasculatures as a result of strong hemoglobin optical absorption. The high-quality chorioretinal microvascular imaging acquired by PAOM implies its great potential in understanding pathological mechanisms and developing therapeutic strategies for major chorioretinal diseases that correlate with vascular disorders.  相似文献   

15.
OBJECTIVE: This study aimed to explore the potential of in vivo q-space imaging in the differentiation between different cerebral water components. MATERIALS AND METHODS: Diffusion-weighted imaging was performed in six directions with 32 equally spaced q values and a maximum b value of 6600 s/mm(2). The shape of the signal-attenuation curve and the displacement propagator were examined and compared with a normal distribution using the kurtosis parameter. Maps displaying kurtosis, fast and slow components of the apparent diffusion coefficients, fractional anisotropy and directional diffusion were calculated. The displacement propagator was further described by the full width at half and at tenth maximum and by the probability density of zero displacement P(0). Three healthy volunteers and three patients with previously diagnosed multiple sclerosis (MS) were examined. RESULTS: Simulations indicated that the kurtosis of a signal-attenuation curve can determine if more than one water component is present and that care must be taken to select an appropriate threshold. It was possible to distinguish MS plaques in both signal and diffusional kurtosis maps, and in one patient, plaques of different degree of demyelinization showed different behavior. DISCUSSION: Our results indicate that in vivo q-space analysis is a potential tool for the assessment of different cerebral water components, and it might extend the diagnostic interpretation of data from diffusion magnetic resonance imaging.  相似文献   

16.
We introduce a compact two-photon fluorescence microendoscope based on a compound gradient refractive index endoscope probe, a DC micromotor for remote adjustment of the image plane, and a flexible photonic bandgap fiber for near distortion-free delivery of ultrashort excitation pulses. The imaging head has a mass of only 3.9 g and provides micrometer-scale resolution. We used portable two-photon microendoscopy to visualize hippocampal blood vessels in the brains of live mice.  相似文献   

17.
In vivo proton and phosphorus magnetic resonance spectroscopy (MRS) studies were performed at 1.5 T on two patients (siblings) diagnosed as having a mitochondrial cytopathy. The clinical diagnosis was based on a complete battery of biochemical tests, electron microscopy and modified Gomori trichrome stain studies of muscle. Proton spectra from the gastrocnemius muscle were recorded using the stimulated echo acquisition mode (STEAM) and the phosphorus spectra were obtained using the depth-resolved surface coil spectroscopy (DRESS) sequence. Proton resonances from neutral fats in the patients were found to be strikingly weak compared to normals. The ratios [PCr]/[ATP] and [PCr]/[Pi] and the pH values, as inferred from the phosphorus MRS, were found to be marginally decreased compared to normals. These studies indicate defective fatty acid metabolism in these two patients. It is, however, not known whether the abnormal mitochondrial ultrastructure represents a primary abnormality or secondary to defective fatty acid metabolism.  相似文献   

18.
主要探讨频率校正技术在活体肝脏1H磁共振波谱的应用价值.肝脏单体素1H 磁共振波谱采用PRESS序列,频率位移分析和校正基于频域谱的残余水峰. 结果表明,5例健康志愿者频率变化的标准偏差为7.92±4.12 Hz; 采用频率校正方法处理后, 残余水峰和脂肪峰(-(CH2)n-)的谱线明显变窄,信噪比得到一定程度的改善. 因此频率校正技术可以改善活体肝脏1H磁共振波谱的谱质量,从而增加磁共振波谱在肝脏病变评价中的准确性.  相似文献   

19.
In vivo full-field (FF) optical coherence tomography (OCT) images of human retina are presented by using a rapidly tunable laser source in combination with an ultra-high-speed camera. Fourier-domain FF-OCT provided a way to increase the speed of retinal imaging by parallel acquisition of A-scans. Reduced contrast caused by cross talk was observed only below the retinal pigment epithelium. With a 100Hz sweep rate, FF-OCT was fast enough to acquire OCT images with acceptable motion artifacts. FF-OCT allows ultrafast retinal imaging, boosting image speed by a lack of moving parts and a considerably higher irradiation power.  相似文献   

20.
The diffusion coefficient of lipids, Dl, within bone marrow, fat deposits and metabolically active intracellular lipids in vivo will depend on several factors including the precise chemical composition of the lipid distribution (chain lengths, degree of unsaturation, etc.) as well as the temperature. As such, Dl may ultimately prove of value in assessing abnormal fatty acid distributions linked to diseases such as cystic fibrosis, diabetes and coronary heart disease. A sensitive temperature dependence of Dl may also prove of value for MR-guided thermal therapies for bone tumors or disease within other fatty tissues like the breast. Measuring diffusion coefficients of high molecular weight lipids in vivo is, however, technically difficult for a number of reasons. For instance, due to the much lower diffusion coefficients compared to water, much higher b factors than those used for central nervous system applications are needed. In addition, the pulse sequence design must incorporate, as much as possible, immunity to motion, susceptibility and chemical shift effects present whenever body imaging is performed. In this work, high b-factor line scan diffusion imaging sequences were designed, implemented and tested for Dl measurement using a 4.7-T horizontal bore animal scanner. The gradient set available allowed for b factors as high as 0.03 μs/nm2 (30,000 s/mm2) at echo times as short as 42 ms. The methods were used to measure lipid diffusion coefficients within the marrow of rat paws in vivo, yielding lipid diffusion coefficients approximately two orders of magnitude smaller than typical tissue water diffusion coefficients. Phantom experiments that demonstrate the sensitivity of lipid diffusion coefficients to chain length and temperature were also performed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏