首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Wang  Fang  Gong  Wencheng  Wang  Lili  Chen  Zilin 《Mikrochimica acta》2015,182(11):1949-1956

Reduced graphene oxide (RGO) was used to construct a bienzyme biosensor containing horseradish peroxidase (HRP) and glucose oxidase (GOx). A poly(toluidine blue) (pTB) film containing RGO acted as both enzyme immobilization matrix and electron transfer mediator. The bienzyme biosensor was characterized by electrochemical techniques and displays a highly sensitive amperometric response to glucose and hydrogen peroxide (H2O2) at a potential as low as −0.1 V (vs. SCE). It is shown that use of RGO causes a strong enhancement on the amperometric responses. H2O2 formed by the action of GOx in the presence of oxygen can be further reduced by HRP in the pTB film contacting the RGO modified electrode. In the absence of oxygen, glucose oxidation proceeds by another mechanism in which electron transfer occurs from GOx to the electrode and with pTB acting as the mediator. Amperometric responses to glucose and H2O2 follow Michaelis-Menten kinetics. The experimental conditions were optimized, and under these conditions glucose can be determined in the 80 μM to 3.0 mM range with a detection limit of 50 μM. H2O2, in turn, can be quantified in up to 30.0 μM concentration with a detection limit of 0.2 μM. The bienzyme biosensor is reproducible, repeatable and stable. Finally, it has been successfully applied to the determination of glucose in plasma samples.

Schematic representation of glocuse detection at GCE/RGO/pTB-HRP-GOx.

  相似文献   

2.
3.
The formation of covalently linked composites of multi–walled carbon nanotubes (MWCNT) and glucose oxidase (GOD) with high-function density for use as a biosensing interface is described. The reaction intermediates and the final product were characterized by using FT–IR spectroscopy, and the MWCNT-coated GOD nanocomposites were examined by atomic force microscopy (AFM) and transmission electron microscopy (TEM). Interestingly, it was found that the GOD–MWCNT composites are highly water soluble. Electrochemical characterization of the GOD–MWCNT composites that were modified on a glassy carbon electrode shows that the covalently linked GOD retains its bioactivity and can specifically catalyze the oxidation of glucose. The oxidation current shows a linear dependence on the glucose concentration in the solution in the range of 0.5–40 mM with a detection limit of 30 μM and a detection sensitivity of 11.3 μA/mMcm2. The present method may provide a way to synthesize MWCNT related composites with other biomolecules and for the construction of enzymatic reaction-based biofuel cells and biosensors. Supported by grants from the National Natural Science Foundation of China (NSFC, No. 20125515; 90206037; 20375016) and the Natural Science Foundation of Jiangsu Province (Grant No. BK 2004210)  相似文献   

4.
An amperometric glucose biosensor is developed that is based on immobilization of glucose oxidase (GOD) in a composite film of poly(o-aminophenol) (POAP) and carbon nanotubes (CNT), which are electrochemically co-polymerized at a gold (Au) electrode. Because of the high surface per volume ratio and excellent electrical conductivity of CNT, the biosensor based on an Au/POAP/CNT/GOD electrode has lower detection limit (0.01 mM), larger maximum response current (0.24 mA cm(-2)) and higher sensitivity (11.4 mA M(-1) cm(-2)) than the values of the biosensor based on an Au/POAP/GOD electrode. Additionally, the biosensor shows fast response time, large response current, and good anti-interferent ability for ascorbic acid, uric acid and acetaminophen. Good reproducibility and stability of the biosensor are also observed.  相似文献   

5.
An enzymatic electrochemical biosensor was prepared based on glucose oxidase (GOD) immobilized on single-walled carbon nanotubes/Nile blue (Nb–SWCNTs) nanocomposite cross-linked with glutaraldehyde on graphite electrode. The function of glucose biosensor is based on the electrocatalytic reduction of H2O2 generated by the reaction of the enzyme with glucose molecules. The biosensor was characterized by Fourier transform infrared (FTIR) spectroscopy, emission scanning (FESEM), UV–Vis spectrometry, and voltammetric and amperometric methods. Parameters influencing the performance of the biosensor, namely pH and applied potential, were optimized. Inhibition was carried out for the detection of Hg2+ and Pb2+ species under optimized condition. Inhibition investigations showed that the type of inhibition for both the abov- mentioned heavy metal ions were reversible and competitive.  相似文献   

6.
A novel strategy for fabricating horseradish peroxidase (HRP)-based H(2)O(2) sensor has been developed by combining the merits of carbon sol-gel supporting matrix and nano-scaled particulate gold (nano-Au) mediator. The thiol functional group-derived carbon ceramic electrode (CCE) was first constructed using (3-mercaptopropyl) trimethoxy silane as sol-gel monomer. Then, the stable nano-Au monolayer was obtained through covalent linkage between nano-Au and thiol group on the surface of CCE. The experimental results showed that nano-Au monolayer formed not only could steadily immobilize HRP but also efficiently retain its bioactivity. Hydrogen peroxide was detected with the aid of hydroquinone mediator to transfer electrons between the electrode and HRP. The process parameters for the fabrication of the enzyme electrode and various experimental variables such as the operating potential, mediator concentration and pH of background electrolyte were explored for optimum analytical performance of the enzyme electrode. The biosensor had a fast response of less than 8 s with linear range of 1.22 x 10(-5) to 1.10 x 10(-3)mol l(-1) and a detection limit of 6.1 x 10(-6)mol l(-1). The sensitivity of the sensor for H(2)O(2) was 0.29 A l mol(-1) cm(-2). The activation energy for enzyme reaction was calculated to be 10.1 kJ mol(-1). The enzyme electrode retained 75% of its initial activity after 5 weeks storage in phosphate buffer at pH 7.  相似文献   

7.
Glucose oxidase (GOx) was immobilized in the organic-inorganic Langmuir-Bldogett (LB) films consisting of octadecyltrimethylammonium (ODTA) and nanosized Prussian blue (PB) clusters. The amperometric glucose biosensors based on the LB films were fabricated and tested. It was found that the sensors exhibited a clear response current under an applied voltage of 0.0 V (vs Ag/AgCl). The linearity of current density versus glucose concentration was confirmed below 15 mmol/L concentration. This is the first observation of biosensor function of the hybrid organic-inorganic LB films. The successful preparation of glucose sensors operating at the very low potential indicates that the adsorbed PB clusters in the LB films act as an electrocatalyst for the electrochemical reduction of hydrogen peroxide, which is the final product of the enzymatic reaction sequence. The observed low potential applicability is estimated to inhibit the responses of interferants such as ascorbic acid, uric acid, and acetominophen. It was also found that an electrostatic interaction between positively charged ODTA+ and the adsorbed species of both GOx and PB provided a stabilized adsorption state in the LB films. Such stable immobilization contributes to the steady amperometric response current observed in the present ODTA/PB/GOx LB films.  相似文献   

8.
An amperometric horseradish peroxidase (HRP) inhibition biosensor has been substantially constructed by the help of N,N-dicyclohexylcarbodiimide (DCC), N-hydroxysuccinimide (NHS). The preparation steps and the biosensor response to phenylhydrazine were monitored by electrochemical impedance spectroscopy (EIS), cyclic voltammetry, and chronoamperometry. The proposed biosensor could be applied to determine phenylhydrazine in a 0.10 M phosphate buffer solution containing 1.2 mM hydroquinone and 0.50 mM H(2)O(2) by phenylhydrazine, inhibiting the catalytic activity of the HRP enzyme in the reduction of H(2)O(2). The system was optimized to realize a reliable determination of phenylhydrazine in the range of 2.5 x 10(-7) to 1.1 x 10(-6) M with a detection limit of 8.2 x 10(-8) M and a correlation coefficient of 0.999. The modified electrode displayed good reproducibility, sensitivity and stability for the determination of phenylhydrazine.  相似文献   

9.
We constructed a biosensor by electrodeposition of gold nano-particles (AuNPs) on glassy carbon (GC) and subsequent formation of a 4-mercaptobenzoic acid self-assembled monolayer (SAM). The enzyme horseradish peroxidase (HRP) was then covalently immobilized onto the SAM. Two forms of HRP were employed: non-modified and chemically glycosylated with lactose. Circular dichroism (CD) spectra showed that chemical glycosylation did neither change the tertiary structure of HRP nor the heme environment. The highest sensitivity of the biosensor to hydroquinone was obtained for the biosensor with HRP-lactose (414 nA μM−1) compared to 378 nA μM−1 for the one employing non-modified HRP. The chemically glycosylated form of the enzyme catalyzed the reduction of hydroquinone more rapidly than the native form of the enzyme. The sensor employing lactose-modified HRP also had a lower limit of detection (74 μM) than the HRP biosensor (83 μM). However, most importantly, chemically glycosylation improved the long-term stability of the biosensor, which retained 60% of its activity over a four-month storage period compared to only 10% for HRP. These results highlight improvements by an innovative stabilization method when compared to previously reported enzyme-based biosensors.  相似文献   

10.
 A reagentless amperometric sensor highly sensitive to H2O2 has been prepared by incorporating fumed silica, horseradish peroxidase (HRP) and Meldola Blue into carbon paste. The efficient mediating ability to shift electrons between HRP and the carbon paste electrode via Meldola Blue was investigated by cyclic voltammetric and amperometric measurements. Reproducibility, response time, detection limit, selectivity and effects of applied potential, temperature and pH on the response of the sensor are reported. The high sensitivity of the sensor with a detection limit of 0.1 μmol/l arose from the high efficiency of the bioelectrocatalytic reduction of hydrogen peroxide via HRP and Meldola Blue. The dependence of the Michaelis-Menten constant on the applied potential and the mediator concentration has been investigated and the results are presented. Received: 20 December 1995/Revised: 13 March 1996/Accepted: 16 March 1996  相似文献   

11.
利用溶胶 凝胶法制备壳聚糖 二氧化硅有机无机复合杂化膜,用于对辣根过氧化酶进行固定,制得测定H2O2的电流型生物传感器。以1mmol/LK4Fe(CN)6作为电子媒介体。研究了各种因素如壳聚糖与二氧化硅的比率、pH、温度、工作电位等对传感器响应电流的影响。计时电流法测定H2O2的线性范围为2.0×10-6~6.8×10-4mol/L,检出限为8.0×10-7mol/L。测得酶催化动力学参数米氏常数Km=0 87mmol/L。用该法对实际样品进行了测定。  相似文献   

12.
Ferrocene (Fc) was encapsulated in the cavities of a NaY zeolite by vapor diffusion via sublimation at below 100?°C. The resulting Fc@NaY zeolite composite was investigated by power X-ray diffraction, diffuse reflectance UV?Cvis and FT-IR spectroscopy, and by cyclic voltammetry. The results indicated that Fc was encapsulated into the zeolite whose microporous structure had remained intact. The Fc in the silica matrix had retained its electroactivity and did not leach out. A glucose biosensor was obtained by immobilization of the modified zeolite and glucose oxidase on a carbon paste electrode. It displays a linear response to glucose (from 0.8???M to 4.0?mM), a detection limit of 0.2???M, and a response time of 4?s. The good performance of the biosensor is ascribed to the biocompatibility of the zeolite and presence of Fc which facilitates the electron transfer from the enzyme to the surface of the electrode.
Figure
Reagentless glucose biosensor is constructed by immobilization of glucose oxidase on a ferrocene@NaY zeolite composite. The biosensor displays very good responses to the different concentrations of glucose.  相似文献   

13.
Chen X  Chen J  Deng C  Xiao C  Yang Y  Nie Z  Yao S 《Talanta》2008,76(4):763-767
Doped carbon nanotubes are now extremely attractive and important nanomaterials in bioanalytical applications due to their unique physicochemical properties. In this paper, the boron-doped carbon nanotubes (BCNTs) were used in amperometric biosensors. It has been found that the electrocatalytic activity of the BCNTs modified glassy carbon (GC) electrode toward the oxidation of hydrogen peroxide is much higher than that of the un-doped CNTs modified electrode due to the large amount of edge sites and oxygen-rich groups located at the defective sites induced by boron doping. Glucose oxidase (GOD) was selected as the model enzyme and immobilized on the BCNTs modified glassy carbon electrode by entrapping GOD into poly(o-aminophenol) film. The performance of the sensor was investigated by electrochemical methods. At an optimum potential of +0.60 V and pH 7.0, the biosensor exhibits good characteristics, such as high sensitivity (171.2 nA mM(-1)), low detection limit (3.6 microM), short response time (within 6s), satisfactory anti-interference ability and good stability. The apparent Michaelis-Menten constant (K(m)(app)) is 15.19 mM. The applicability to the whole blood analysis of the enzyme electrode was also evaluated.  相似文献   

14.
A.K. Upadhyay 《Talanta》2009,79(1):38-9495
A novel amperometric biosensor for the analytical determination of hydrogen peroxide was developed. The fabrication of the biosensor was based on the coimmobilization of horseradish peroxidase (HRP), methylene green (MG) and multiwalled carbon nanotubes within ormosils; 3-aminopropyltrimethoxysilane (APTMOS), 2-(3,4-epoxycyclohexyl)ethyltrimethoxysilane (ETMOS) and phenyltrimethoxysilane (PHTMOS). APTMOS determined the hydrophilicity/hydrophobicity of the ormosils and PHTMOS and ETMOS increased the physical and mechanical strength of the ormosil matrix. The ormosil modified electrodes were characterized with SEM, UV-vis spectroscopy and electrochemical methods. Cyclic voltammetry and amperometric measurements demonstrated the MG coimmobilized with HRP in this way, displayed good stability and could efficiently shuttle electrons between immobilized enzyme and electrode, and MWCNTs facilitated the electrocatalytic reduction of H2O2 at reduced over potential. The Micheaelis constant of the immobilized HRP was 1.8 mM, indicating a high affinity of the HRP to H2O2 without loss of enzymatic activity in ormosil matrix. The prepared biosensor had a fast response of H2O2, less than 10 s, and excellent linear range of concentration from 5 × 10−7 to 2 × 10−5 M with the detection limit of 0.5 μM (S/N = 3) under the optimum conditions. At the same time, the influence of solution pH, effect of enzyme amount, steady-state applied potential and temperature on the biosensor were investigated. The enzyme electrode retained about 90% of its initial activity after 30 days of storage in a dry state at 4 °C. The preparation of the developed biosensor was convenient and showed high sensitivity with good stability.  相似文献   

15.
This paper reports a transparent and flexible glucose biosensor of which multi-wall carbon nanotubes (MWNTs) and glucose oxidase (GOx) is layer-by-layer (LBL) self-assembled on a polymer substrate. A thin Ti and Au layers is firstly deposited on the polymer substrate through plasma immersion ion implantation (PIII) and sputtering, respectively. An organic monolayer then forms on the gold surface using thiol chemistry. Subsequently, negatively charged MWNTs and GOx are stably LBL assembled on the modified Au surface, respectively, via alternative electrostatic interaction of the positively charged polyelectrolyte with the oppositely charged MWNTs and GOx. Electrochemical studies show that the multilayer membrane exhibits remarkable electrocatalytic activity to detect glucose molecule. The biosensor displays a linear response range of 0.02–2.2 mM (a correlation coefficient of 0.998) with a low detection limit of 10 μM. This remarkable performance, combined with the large area preparation process, demonstrates this CNT-based multilayer biosensor is well suited for commercial applications.  相似文献   

16.
An electron transfer mediator, 8-dimethylamino-2,3-benzophenoxazine (Meldola Blue), dissolved in the carrier solution in a flow-injection system, was found to reduce the oxidation potential for hydrogen peroxide from 600-1200 mV without mediator to-100 mV vs. Ag/AgCl with the mediator present. The very low background current of reticulated vitreous carbon (RVC) at this potential makes it possible to detect very low levels of hydrogen peroxide or glucose. Glucose oxidase was covalently coupled with carbodiimide to RVC, and the RVC was formed into a column inserted in a flow-injection system. The calibration curve was linear from 30 nM to 10 microM glucose with 5 microM mediator. At higher mediator concentrations, the linear range was extended to 1000 microM, but with a much higher background current. The sample throughput was about 60 h(-1). The current response decreased to 50% of the original response after 20 days. The coulometric yield was high because the sample was pumped through the pores of the RVC. It was 16% and 55% at a flow rate of 1 ml min(-1) at mediator concentrations of 5 and 50 microM respectively.  相似文献   

17.
18.
A new biosensor for the amperometric detection of hydrogen peroxide was developed based on the coimmobilization of horseradish peroxidase (HRP) and methylene blue on a beta-type zeolite modified glassy carbon electrode without the commonly used bovine serum albumin-glutaraldehyde. The intermolecular interaction between enzyme and zeolite matrix was investigated using FT-IR. The cyclic voltammetry and amperometric measurement demonstrated that methylene blue co-immobilized with HRP in this way displayed good stability and could efficiently transfer electrons between immobilized HRP and the electrode. The sensor responded rapidly to H2O2 in the linear range from 2.5 x 10(-6) to 4.0 x 10(-3) M with a detection limit of 0.3 microM. The sensor was stable in continuous operation.  相似文献   

19.
One-step, diameter-selective dispersion of single-walled carbon nanotubes (SWCNTs) has been accomplished through noncovalent complexation of the nanotubes with a water-soluble, biocompatible polymer chitosan at room temperature. Such chitosan-wrapped individual SWCNTs can be used for the immobilization of horseradish peroxidase (HRP) and be used to construct an electrode for direct bioelectrochemical sensing without an electron mediator. The direct electron transfer between HRP and the electrode surface was observed with a formal potential of approximately −0.35 V (vs. saturated calomel electrode) in phosphate buffer solution and the calculated heterogeneous electron transfer rate constant is approximately 23.5 s−1. Experimental results indicate that the immobilized HRP retains its catalytic activity for the reduction of nitric oxide. Such an HRP–SWCNT–chitosan-based biosensor exhibited a rapid response time of less than 6 s and a good linear detection range for nitrite concentration, from 25 to 300 μM with a detection limit of 3 μM. The apparent Michaelis–Menten constant (K m) and the maximum electrode sensitivity (imax/K m) are found to be 7.0 mM and 0.16 μA mM−1, respectively. Both the unique electrical properties of SWCNTs and biocompatibility of chitosan enable the construction of an excellent biosensing platform for improved electrocatalysis of HRP, allowing, specifically, the detection of trace levels of nitric oxide.  相似文献   

20.
A new amperometric biosensor based on adsorption of glucose oxidase (GOx) at the CuGeO3 nanowires (NW) modified glassy carbon electrode (GCE) is reported in this article. The properties of the biosensor were characterized by Fourier transform infrared spectroscopy (FTIR), electrochemical impedance spectroscopy (EIS) and electrochemical techniques. The GCE modified with the CuGeO3 NW/GOD showed excellent electrocatalytical response to the oxidation of glucose. Different parameters including GOx concentration, working potential and pH of supporting electrolyte that governed the analytical performance of the biosensor have been studied in detail and optimized. The biosensor was applied to detect glucose with a linear range of 0.5 to 7 mM. The biosensor exhibited excellent reproducibility and stability.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号