1.
The purpose of this paper is to study the effect of the high-voltage power supply waveform and the presence of a dielectric barrier on the collection of submicron particles in a wire-to-cylinder electrostatic precipitator. The experiments are carried out on two reactors (with or without dielectric barrier on the surface of the cylindrical collector electrode) with the same active section and volume. The results show that the highest collection efficiency is obtained with the negative dc corona. At equivalent electric power consumption, the Dielectric Barrier Discharge (DBD) is as effective as the positive dc corona and the ac corona. The efficiency can reach 99% with both studied reactors, if the necessary power is provided.  相似文献   

2.
A high-temperature electrostatic precipitator (ESP) presents a good solution for hot gas cleaning, which can remove fly ash from pyrolysis gas at temperatures higher than the tar dew point. In this paper, the characteristics of negative DC corona discharge in air and simulated coal pyrolysis gas were studied. The removal of coal pyrolysis furnace fly ash (ash A) was investigated and compared with that of coal-fired power plant fly ash (ash B) in ESP with a temperature ranging from 300?K to 900?K. The current density of simulated gas was higher than that of air under the same discharge voltage and at different temperatures. The simulated gas also had a higher spark voltage and a lower onset voltage compared with air. The fractional collection efficiency of ash A was lower for particles with diameters of larger than 0.1?µm at high temperature, compared with ash B. A lower collection efficiency in simulated gas was obtained for particles with diameters of less than 0.1?µm compared with air. The collection efficiency of submicron particles in simulated gas was usually higher than it in air, especially for particles with diameters of less than 0.04?µm. In simulated gas, the overall collection efficiency of ash A was obviously lower than that of ash B, especially at high temperature. From 300?K to 700?K, the collection efficiencies of both ash samples were as high as above 93%, but the collection efficiency of ash A in simulated gas decreased to 78.7% at 900?K.  相似文献   

3.
The aim of the present parametric study is to enhance the performances of a wire-to-square tube electrostatic precipitator (ESP) for the collection of submicrometer particles using dielectric barrier discharge (DBD). The input parameters under study are: the high voltage waveform, the wire electrode diameter, the collection electrode dimensions (width, discretization and number of collection sides) and the tube cross-section. The electrical measurements show that the discharge mode of the ESP is rather homogeneous. The particle collection efficiency as determined from aerosol spectroscopy measurements is higher at high applied voltage and within a certain frequency range. The parametric study of the ESP points out that using thicker wire electrodes as well as collection electrodes with different number of sides does not deteriorate the ESP performance. However, the penetration decreases with larger or discretized collection electrodes and larger tube cross-sections.  相似文献   

4.
The electrostatic precipitator (ESP) has been extensively used for collecting aerosol particles emitted from coal combustion, but its collection efficiency of PM2.5 (Particulate matter whose aerodynamic diameter is less than 2.5 μm) is relatively low due to insufficient particle charging. The positive pulsed ESP is considered to enhance particle charging and improve collection efficiency. A laboratory-scale pulsed ESP with wire-plate electrode configuration was established to investigate the particle charging and penetration efficiency under controlled operating conditions of different applied impulse peak voltages, impulse frequencies, dust loadings and residence times. The results show that most particles larger than 0.2 μm are negatively charged, while most particles smaller than 0.2 μm are positively charged. For a given operating condition, the particle penetration efficiency curve has the highest penetration efficiency for particles with a diameter near 0.2 μm, and there is always a negative correlation between the particle penetration efficiency and the average number of charges per particle. Under the same operating conditions, the particle penetration efficiency decreases with increasing impulse peak voltage and impulse frequency, but increases as the dust loading increases. The results imply that residence time of 4 s is optimum for particle charging and collection. PM2.5 number reduction exceeding 90% was achieved in our pulsed ESP.  相似文献   

5.
In the present paper, an analytical approach is proposed to determine the radial distributions of electric field, electrons, ion densities and temperature of a DC corona discharge in wire-to-cylinder geometry, using oxygen as feed gas. The current–voltage (CV) characteristic measured in experiments is used as an input in the calculation. The objective of this work is to provide approximated analytical solutions of the corona discharge with low computational cost, which can be useful in different technological applications, such as the generation of ozone or the decomposition of pollutant gases. The predictions of the analytical model are compared with the results obtained from a much more complete numerical simulation.  相似文献   

6.
《Current Applied Physics》2010,10(6):1391-1401
The purpose of this work is to highlight the chemical kinetics in plasma of pure oxygen. A comprehensive model of ozone generation in wire-to-cylinder negative corona discharge is presented. The model combines the physical processes in the discharge with the chemistry of ozone formation. It is based on an extensive reaction scheme including the major electronic and ionic processes. The importance of excited atomic and molecular states is demonstrated. The obtained results show clearly that the surface material affect quite well the ozone decomposition.  相似文献   

7.
A CFD model was developed to describe the particle laden gas flow through an ESP, particle charging and collection. The corona discharge was modeled using the open source software OpenFOAM to solve the Poison and charge conservation equations, and results were entered using user-defined field functions in the commercial CFD software STAR-CCM+. The gas flow, EHD flow, particle charging and dynamics were modeled using STAR-CCM+. The developed CFD model allows for direct solution of the drift and diffusional flux of gas ions. The influence of the various ESP dimensions, operating parameters and ash properties on the collection efficiency are reported.  相似文献   

8.
Recently, narrow electrostatic precipitators (ESPs) have become a subject of interest because of their possible application for the cleaning of the exhaust gases emitted by diesel engines. Diesel engines emit fine particles, which are harmful to human and animal health. There are several methods for decrease particulate emission from a diesel engines, but up to now, these methods are not enough effective or very expensive. Therefore, an electrostatic precipitation was proposed as an alternative method for control of a diesel particulate emission.In this work, results of electrohydrodynamic (EHD) secondary flow and particle collection efficiency measurements in a narrow wire-cylinder type ESP are presented. The ESP was a glass cylinder (300 mm × 29 mm) equipped with a wire discharge electrode and two collecting cylinder-electrodes. A 0.23 mm in diameter and 100 mm long stainless-steel discharge wire electrode was mounted in the center of the cylinder, parallel to the main flow direction. The collecting electrodes were made of stainless steel cylinders, each with a length of 100 mm and inner diameter of 25.5 mm. An air flow seeded with a cigarette smoke was blown along the ESP duct with an average velocity of 0.9 m/s.The EHD secondary flow was measured using 2-dimensional particle image velocimetry (PIV) method. The PIV measurements were carried out in the wire electrode mid-plane, perpendicularly to the wire and the collecting electrodes. The results show similarities and differences of the particle flow in the wire-cylinder type ESP for a negative and a positive DC voltage polarity.The collection efficiency was calculated from the fractional particle concentration. The fractional particle concentration was measured using the optical aerosol spectrometer. The results of the fractional collection efficiency confirmed the common view that the collection efficiency of fine particles in the ESP increases with increasing voltage and it is higher for negative voltage polarity and decreases when decreasing particle diameter.  相似文献   

9.
In this work, the results of electrohydrodynamic (EHD) secondary flow and particle collection efficiency measurements in a spike-plate type electrostatic precipitator (ESP) are presented. The EHD secondary flow was measured using 2- and 3-dimensional particle image velocimetry (PIV) method under the negative DC voltage. The PIV measurements were carried out in several cross-sectional planes along and across the ESP duct. The results show a complex and turbulent flow structure in the ESP. The EHD secondary flow significantly depends on applied voltage and measuring cross-sectional plane position in respect to the spike tip. The partial collection efficiency of the ESP was measured for negative and positive DC voltage. The particle concentration with and without discharge was measured at the ESP exit using an optical aerosol spectrometer.  相似文献   

10.
Using electrostatic precipitators (ESPs) in filtration systems results in higher system energy efficiency than fiber-based filters, but particle re-entrainment could lower the collection efficiency of ESPs. This paper demonstrates a novel ESP that utilizes foam-covered collecting electrodes to reduce particle re-entrainment and enhance collection efficiency. Particles that settle down within the pores of the foam are less likely to re-enter the airflow. Results show that foam-covered ESPs have 99 percent collection efficiency. Parametric plots demonstrate the effects of the key design variables, such as corona voltage, repelling voltage, and free airflow velocity on collection efficiency.  相似文献   

11.
Formation of back corona and its effect on the voltage–current characteristics, etc., have been analysed by several authors. It has also been examined how the harmful effect of back corona can be reduced, for example by the application of pulse energisation. However, to find an optimal solution, modelling of the back corona effect is necessary. Different back corona models were created to estimate the time of its development, the change in current–voltage characteristics, the decrease in particle charge and finally, the collection efficiency of the ESP with back corona. In this paper the authors present an improved numerical ESP model that is capable of determining the parameters of back corona in such cases, when pulse energisation is applied for the power supply of the electrostatic precipitator. Based on the modular structure of the model, different modules calculate the distribution of gas velocity, electric field intensity, particle charging and particle movement. All these parameters are important to determine the properties of back corona while it feeds back on these parameters; therefore iteration is necessary to obtain reliable result. The harmful effects of back corona can be characterised with the help of the evaluation of calculated results.  相似文献   

12.
In this paper, experimental investigations of the discharge characteristics of magnetically enhanced corona discharges, for the purpose of capturing fine aerosol particles, are presented. The discharge mechanism during such a process is analyzed as well. The effects of magnetic enhancement under different magnet flux densities, and in positive- or negative-corona discharges, were experimentally compared. The magnetically enhanced effects in different inter-electrode regions were studied. Experimental results demonstrated that the magnetic field could efficiently increase the concentrations of both the negative ions and the free electrons during negative-corona discharge. The dominant mechanism of magnetic enhancement in a corona discharge involves the Larmor precessions of free electrons which enhance ionization of the gas molecules near the discharge electrode. A convenient configuration for enhancing corona discharge was formed by placing permanent magnets with a local strong magnetic field near the discharge electrode. A magnetically enhanced negative-corona (MNC) pre-charger was assembled in front of an electrostatic enhancement filter. The influence of the MNC pre-charger on the efficiencies of an electrostatic enhancement filter was measured and compared with that of a conventional corona pre-charger. The free-electron-charging mechanism of the MNC pre-charger was preliminarily analyzed. Our results show that the new pre-charging technique is promising for capturing fine aerosol particles in electrostatic enhancement filters or electrostatic precipitators.  相似文献   

13.
A laboratory electrostatic precipitator (ESP) together with a bipolar pre-charger has been designed for studying charge-induced agglomeration and fine particle collection. In terms of particle numbers, the ESP collection efficiency drops to its minimum of near 90% for particles with diameters of near 0.2 μm and 3 μm. For other particles, its value is around 94%–95%. By using the bipolar pre-charger, the grade efficiency can be significantly increased for all particle sizes due to the charge-induced particle agglomeration. The grade collection efficiency rises to about 95%–98% for all size particles.  相似文献   

14.
Lab-scale, two-stage electrostatic precipitation system comprising of precharging stage, in which PM2.5 particles are electrically charged, and collection stage, in which the charged particles are removed from the flowing gas by electric field, was investigated in this paper. Two types of electrostatic particle prechargers were compared with respect to the collection efficiency of the system: (1) co-flow precharger, in which ionic current was generated co-currently with the gas conveying the particles, and (2) counter-flow precharger, in which ionic current was generated oppositely to the flowing gas. In each case, the electrodes of precharger were supplied with DC or AC high-voltage in order to compare the effect of discharge mode on the collection efficiency of two-stage electrostatic precipitator. The collection stage was formed by two parallel-plate electrodes connected to DC high voltage source. Plate electrodes without discharge points (spikes) are corona-free electrodes, which prevent the collection stage from electrical discharges, and reduce the probability of back discharge ignition. The back discharge decreases collection efficiency of conventional electrostatic precipitators.It was concluded that the co-flow electrode configuration of the precharger, supplied with DC high voltage, has the highest total number collection efficiency for PM2.5 particles, higher than 95% and the mass collection efficiency larger than 99%. The counter-flow precharger provided only about 90% number collection efficiency of two-stage electrostatic precipitator. It was also shown that by AC electrode excitation, the collection efficiency of the system is lower than for DC supply. The two-stage electrostatic precipitators allowed obtaining higher fractional collection efficiency for PM2.5 particles than other conventional systems and can be recommended as highly effective devices for gas cleaning in power plants or cement industry.  相似文献   

15.
Several electrode arrangements have been proposed to enhance the efficiency of insulating materials charging by corona discharge. Recent studies pointed out that the presence of metal strips in the proximity of a dual-type high voltage electrode increases the total current measured at the surface of the collecting electrode, decreases the corona onset voltage value and enlarges the reparation of current density as well. The aim of this paper is to evaluate the benefits of using such an electrode arrangement for corona charging of non-conductive particulate materials in belt-type corona-electrostatic separators. The experimental study was carried out with samples of Aluminum and Polystyrene particles in the size class 125–250 μm. The presence of grounded strips reduces the electric wind, which is associated to corona discharge but not tolerated in such processes that involve micronized materials. At the same time, it improves the corona charging conditions of non-conductive materials and as consequence the overall efficiency of the corona-electrostatic separation process. The use of the new electrode configuration is characterized by both high recovery rates and better purities of the separated products.  相似文献   

16.
An analysis of the electrostatic gas cleaning fundamental phenomenon shows an essential influence of discharge electrode construction on the gas cleaning process efficiency.In the physical model tests there were used rigid discharge electrodes with corona emitting elements of various geometries. Different constructions of discharge electrode were tested in the aspect of discharge current uniform distribution on collecting electrode surfaces. Measurements of discharge current distribution has been carried out for discharge electrodes with different spike shapes and in different electric field geometry. The research aim was to determine the optimal discharge electrode construction ensuring high collection efficiency of fine particles. Collection efficiency measurements of selected fly ash samples (from coal fired boilers) were carried out on a laboratory testing bench in a horizontal electrostatic precipitator model.  相似文献   

17.
In order to improve the particle collection efficiency of the electrostatic precipitator (ESP), a transverse plate ESP with bipolar discharge electrodes is proposed. The simulations of the velocity distribution have shown that when the inlet velocity is 1 m/s, within the range of 40 mm from electrode plate, the average velocities of windward side and leeward side are less than 0.7 m/s and 0.3 m/s respectively. It is clear that the velocity near the collection electrode plate of this bipolar ESP is much lower than that of the ordinary ESP at the same inlet velocity. This low velocity can lead to higher efficiency for fine dust collection due to the less dust re-entrainment in ESP. It is also found that the average velocities are getting lower when the distance between plates electrodes are greater than 150 mm in accordance with the simulations. The voltage current characteristics of the bipolar ESP are superior to the ordinary ESP. The pressure drop of the bipolar ESP is about 30% higher than that of the ordinary one. The dust penetration of the bipolar ESP is about 54% less than that of the ordinary ESP when the sintering dust with 25.405 μm mass median diameter is used as the test particulate under the condition of the electric field from 2.1 kV/cm to 3.2 kV/cm and the velocity from 1.0 m/s to 1.5 m/s.  相似文献   

18.
Results of spectroscopic investigations of back discharge generated in point-plane electrode geometry in ambient air at atmospheric pressure are presented in the paper. The back discharge was generated for the plate electrode covered with fly ash layer. To characterize the discharge process, the emission spectra were measured for the back discharges and compared with those obtained for corona discharge generated in the same electrode configuration but with dielectric layer removed. The measurements have shown that spectral lines emitted by the back discharge depend on the forms of discharge and the discharge current. From comparison of spectral lines of back and normal discharges an effect of the dust layer on discharge morphology can be determined. In normal conditions, the emission spectra are dominated by atmospheric components (molecular nitrogen, atomic oxygen and nitrogen) but for back-discharges, additional lines due to elements and compounds in fly ash were also identified. The studies of back discharge were undertaken because this type of discharge decreases the collection efficiency in electrostatic precipitators.  相似文献   

19.
Electrospray was combined with an electrostatic precipitator (ESP) to enhance the collection efficiency of monodisperse nanometer-sized particles. The electrospray of deionized water produced water droplets with sizes ranging from 10 to 300 μm. The combination of the ESP with the electrospray enhanced collection of particles by 21–36% depending on the particle size. The combination of the ESP and the electrospray was also found to reduce the energy consumption of the ESP.  相似文献   

20.
环形电极单间隙电晕放电伏安特性   总被引:1,自引:1,他引:0       下载免费PDF全文
基于用于直线变压器型驱动源的多间隙气体开关结构,提出一种环形放电间隙与电晕针并联的气体火花间隙。通过测量间隙耐压过程中电晕放电的伏安特性,研究了气体介质、气压、电晕极性、电晕针长度以及针尖对应电极结构等因素对伏安特性的影响。结果表明:以空气为绝缘气体,负极性电晕可获得较稳定的伏安特性;改变电晕针长度和针尖对应电极结构可方便地实现对电晕放电伏安特性的调节以满足开关要求。  相似文献   