首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
This study presents a method based on the use of multiple headspace solid-phase microextraction (MHS-SPME) for the quantitative analysis of 4-ethylphenol, 4-ethylguaiacol, 4-vinylphenol and 4-vinylguaiacol. MHS-SPME is a modification of SPME that implies several consecutive extractions from the same sample and avoids possible matrix effects. This study demonstrates the existence of a matrix effect in the analysis of compounds responsible for Brett character in wine when an HS-SPME based method is used with a carbowax/divinylbenzene (CW/DVB) fibre. For this reason, MHS-SPME is proposed as an alternative technique with respect to HS-SPME. The method proposed was validated and the detection limits obtained were 0.06 microg/l for 4-ethylguaiacol and 4-ethylphenol and, 0.20 microg/l for 4-vinylguaiacol and 0.12 microg/l for 4-vinylphenol. These detection limits are below the odour detection thresholds of the compounds in wine matrices. The repeatability obtained, in terms of relative standard deviation (RSD), was considered acceptable, ranging from 1 to 12%. To evaluate the applicability of the proposed MHS-SPME method, concentration results were compared with those obtained with the standard addition method, and the results were similar with both methods. Furthermore, the new method was satisfactorily applied to a number of commercial red, white and rosé wines. Therefore, MHS-SPME can be considered as an alternative to avoid the matrix effect in wine samples.  相似文献   

2.
In this paper, we propose a comparative study to check the matrix effect on the extraction of three chlorophenols, 2,4,6-trichlorophenol (TCP), 2,3,4,6-tetrachlorophenol and pentachlorophenol, direct precursors of 2,4,6-trichloroanisole, in synthetic and commercial wines (white and red wines). A rapid, simple and sensitive methodology based on solid-phase microextraction (SPME) and GC with electron capture detection (GC-ECD) and mass spectrometric detection (GC-MS) was developed and the variables affecting the extraction process (temperature, time and salt content) were examined employing a factorial design at two levels. Since GC-ECD does not allow the clear identification of target analytes in white wine, owing to overlapped interferences, GC-MS/MS was used for subsequent examinations. Calibration curves were constructed in synthetic, white and red wine. Significant differences between the slopes of synthetic and red wine, with the exception of TCP, were observed. Analytical parameters were evaluated and satisfactory results were obtained, showing the usefulness of the headspace SPME (HS-SPME) method for determining chlorophenolic compounds in wines.  相似文献   

3.
The occurrence of off-flavours in wines and especially the so-called "cork taint defect" represents one of the most serious problem in wine industry in which 2,4,6-trichloroanisole has been blamed as the main responsible. The development of analytical methods for haloanisoles determination in wine/cork represent a challenge, mainly due to food matrix complexity and low taste and odour (T&O) threshold levels which are generally beyond the sensitivity of the analytical systems. In this work, a method based on the combined use of the recently developed multiple headspace solid-phase microextraction (MHS-SPME) and gas chromatography-ion-trap mass spectrometry has been optimised for the determination of haloanisoles in wines. This powerful analytical methodology is compared with several analytical approaches based on pervaporation, an innovative membrane-based technique similar to dynamic headspace. Analytical features of the methods assayed reveal their suitability for the appraisal of haloanisoles in this matrix in which threshold odor concentrations are in the range 4-40 ng l(-1). The analytical approaches have been applied to the analysis of haloanisoles in different Spanish white and red wines, in which spiking experiments showed good recoveries for the methodologies assayed.  相似文献   

4.
Multiple headspace solid-phase microextraction (MHS-SPME) coupled with gas chromatography-mass spectrometry has been applied in order to determine 2,4,6-trichloroanisole (2,4,6-TCA), guaiacol, 1-octen-3-ol and 1-octen-3-one in three samples of cork stoppers. These compounds are responsible for cork taint in wine and can modify the organoleptic properties of bottled wine. Variables such as temperature, addition of water, extraction time, and amount of cork were studied. The extractions were performed with a 50/30 microm divinylbenzene-carboxen-polydimethylsiloxane (DVB-CAR-PDMS) fibre for 45 min at 100 degrees C using 20 mg of cork. For calibration, 50 microL of VOC aqueous solutions were used and the extraction were carried out for 45 min at 75 degrees C. The limits of detection of the method expressed as ng of VOC per g of cork were 0.3 for 2,4,6-TCA, 7.5 for guaiacol, 1.7 for 1-octen-3-one and 1.9 for 1-octen-3-ol. Relative standard deviation of replicate samples was less than 10%. Significant losses of analytes were observed when the samples were ground at room temperature. Finally, a recovery study was performed and the MHS-SPME results were validated using Soxhlet extraction results.  相似文献   

5.
A novel dispersive liquid-liquid microextraction (DLLME) method, coupled to gas chromatography-tandem mass spectrometry (GC-MS/MS), was developed for simultaneously determining the main compounds responsible for cork taint (2,4,6-trichloranisole (TCA), 2,3,4,6-tetrachloroanisole (TeCA), 2,4,6-tribromoanisole (TBA) and pentachloranisole (PCA)) and Brett character (4-ethylguaiacol (EG), 4-ethylphenol (EP), 4-vinylguaiacol (VG) and 4-vinylphenol (VP)) in wines. Optimisation of DLLME procedure was performed by evaluating the type of disperser and extraction solvents and the temperature and salt addition effects. The volumes of disperser and extraction solvents were also optimised by means of a central composite design combined with desirability functions. Under optimum conditions, 5 mL of wine were extracted with an extraction mixture consisting of 1.43 mL of acetone, and 173 μL of chloroform at room temperature. The analytical characteristics of the method were evaluated. Satisfactory linearity (with correlation coefficients over 0.992), repeatability (below 11.6%) and between-days precision (below 11.0%) were obtained for all target analytes. Detection limits attained were at similar levels or even lower than the olfactory threshold of the studied compounds. Finally, the developed method was successfully applied to the analysis of wine samples. To our knowledge, this is the first time that DLLME has been applied to simultaneously determine the compounds responsible for cork taint and Brett character in wine.  相似文献   

6.
Multiple headspace solid-phase microextraction (MHS-SPME) with gas chromatography–mass spectrometry is proposed for quantification of nine volatile oak compounds in aged wines. These compounds are formed and extracted by wine when it is matured in oak barrels and are responsible for particular organoleptic properties and the high quality of these wines. Some important variables of the extraction process, for example volume of sample and extraction time, were studied. Extraction of 50 μL wine was performed with a divinylbenzene–Carboxen–polydimethylsiloxane fibre at 55 °C for 60 min. For calibration the same conditions were used, except that the wine was substituted by 50 μL of a standard solution in synthetic wine. The linearity, detection limits, and repeatability of the method were determined by use of standard solutions in synthetic wine. Detection limits were between 0.01 and 10 μg L−1 (for eugenol and furfural, respectively) and repeatability, expressed as relative standard deviation, was from 2 to 6%. The method was used to analyse six red wines and the concentrations obtained were statistically compared with those obtained by the standard addition method for the same wines.  相似文献   

7.
This paper describes the development of an analytical method consisting of pressurised fluid extraction (PFE) and gas chromatography-mass spectrometry (GC-MS) using experimental designs to determine two volatile compounds in naturally-tainted cork stoppers. The target analytes, 2,4,6-trichloroanisole (2,4,6-TCA) and guaiacol, are involved in the cork taint of wine. First, a Plackett-Burman experimental design was carried out in order to determine the significant experimental parameters affecting the PFE process, and then a central composite design was used to optimise these significant parameters. Once the method had been optimised, the influence of the number of extraction cycles was studied. The method was applied to determine the concentration of 2,4,6-TCA and guaiacol in three cork samples, and the results were compared with the ones obtained by multiple headspace-solid-phase microextraction (MHS-SPME) and by Soxhlet extraction.  相似文献   

8.
In this study we present a rapid and simultaneous assay method using headspace (HS) solid-phase microextraction (SPME)/gas chromatography (GC)/electron impact (EI) mass spectrometry (MS) (selected ion monitoring) for contaminants causing the principal organoleptic defects of wine (2,4,6-trichloroanisole, 2,3,4,6-tetrachloroanisole, pentachloroanisole, 2,4,6-tribromoanisole, 1-octen-3-ol, geosmin, 2-methylisoborneol, 3-isopropyl-2-methoxypyrazine, fenchol, fenchone, 2-methoxy-3,5-dimethylpyrazine, 4-ethylphenol, 4-ethylguaiacol, 4-vinylphenol, 4-vinylguaiacol, 3-isobutyl-2-methoxypyrazine, guaiacol and ethyl acetate). The method was validated according to protocols NF ISO 5725-1, 2 and NF V03-110. Its characteristics (limit of detection (LOD), limit of quantification (LOQ), uncertainties) were determined after having optimised the SPME parameters. The target contaminants were quantified in the wines below their threshold of perception with a satisfactory relative standard deviation for all the analytes except ethyl acetate (RSD=36%); for that, the assay method permits clear differentiation of the wines that are at risk of presenting an acescent character, i.e. containing more than 120mgL(-1) ethyl acetate. The target volatile and odorous substances were determined at concentrations significantly below their threshold of perception in a hydroalcoholic context and their threshold of recovery in wines.  相似文献   

9.
A new extraction method for the analysis of the volatile fraction of white and red wines has been developed and validated. A dehydration step with MgSO4 separated an aroma compounds-rich alcoholic-glycerine layer. Spiked samples showed good recoveries in the range between 75 and 120% with CVmax% of 17, except for 2-phenylethanol and y-butyrolactone for which recoveries in red wines were under 60%, and for monoethylsuccinate, where recoveries averaged 50 and 60% in white and red wines, respectively. Method repeatability and intermediate precision showed good CVmax% with minimum and maximum values between 7.7 and 24, and between 18.7 and 25.0, respectively. The average determination coefficients were greater than 0.99 with CVmax% of 13. The instrumental LOD and LOQ were, in all cases, under 0.05 mg/L, except for 2,3 butanediol (0.20 mg/L). Overall, the presence of wine matrix affected aroma compounds responses in GC/MS analysis. These observations indicate that the use of a matrix-matched calibration curve is mandatory to obtain reliable quantitative data.  相似文献   

10.
A method for analysis of heavy sulphur compounds in wines, based on gas chromatography (GC) with flame photometric detection, is reported. Wine samples preparation includes a dichloromethane liquid-liquid extraction followed by concentration under a nitrogen atmosphere. The extracted fraction was also analysed by GC-mass spectrometry. The method enables high recovery of sulphur compounds in wine and satisfies the requirements of repeatability and sensitivity. Applications of the method to red, white and Port wines are reported.  相似文献   

11.
A gas chromatography-high-resolution mass spectrometry (GC-HRMS) method using solid-phase microextraction (SPME) for the determination of 2,4,6-trichloroanisole (TCA) and 2,4,6-tribromoanisole (TBA) in wine at low ng L(-1) levels was developed. A robust SPME method was developed by optimizing several different parameters, including type of fiber, salt addition, sample volume, extraction and desorption time. The quantification limit for TCA and TBA in wine was lowered substantially using GC-HRMS in combination with the optimized SPME method and allowed the detection of low analyte concentrations (ng L(-1)) with good accuracy. Limits of quantification for red wine of 0.3 ng L(-1) for TCA and 0.2 ng L(-1) for TBA with gas chromatography-negative chemical ionization mass spectrometry and 0.03 ng L(-1) for TCA and TBA were achieved using GC-HRMS. The method was applied to 30 wines of which 4 wines were sensorically qualified as cork defected. TCA was found in three of these wines with concentrations in the range 2-25 ng L(-1). TBA was not detected in any of the samples.  相似文献   

12.
A method for analysing low-volatility sulphur compounds using solid-phase microextraction has been developed. The analytes were extracted directly from the liquid sample using fibres coated with different stationary phases. The best extraction efficiency was obtained with Carboxen-polydimethylsiloxane coating. Ionic strength, sample volume, time and temperature of the extraction were optimised and the matrix effect studied. The method enables 15 sulphur compounds in wine to be determined at trace levels with recoveries close to 100% and limits of detection between 0.05 and 5 microg/L. The overall method was successfully applied to the determination of the sulphur compounds studied in several red, white and rosé wines.  相似文献   

13.
Solid-phase extraction cartridges (SPE)-GC/MS method was used to analyse red wines aromas. The matrix effect was studied with chemicals standard prepared in synthetic wines with water/alcohol solutions (12% ethanol, v/v) following the procedure proposed. The method offers good reproducibility since the relative standard deviations (RSD%) for the volatile compounds levels were less than 9%. This method was used to differentiate the aroma of one hundred mono-varietal young, crianza, reserva and gran reserva La Mancha D.O. wines (cv. Tempranillo) on the basis of oak barrel contact period. Samples were checked at ten time points over 36 months. Sixty important wine odorants, such as volatile phenols, vanillin derivatives, lactones, norisoprenoids, benzene compounds, esters and terpenols, can be quantitatively determined in a single run. Results showed significant quantitative differences in the volatile profiles of wines depending on the length of time in contact with wood, even in wines belonging to the same commercial category. Stepwise multiple linear regression (SMLR) was used to obtain a model that predicted the time of barrel ageing to which wines were submitted in relation with the wine volatile composition. A successful function based on eight compounds with a mean deviation of 0.37 months in the predictions, was obtained.  相似文献   

14.
An analytical method for the determination of volatile and semi-volatile compounds representing various chemical groups in ice wines was developed and optimized in the presented study. A combination of the fully automated solid-phase microextraction (SPME) sample preparation technique and gas chromatographic-mass spectrometric (GC-MS) system to perform the final chromatographic separation and identification of the analytes of interest was utilized. A time-of-flight mass spectrometric (TOF-MS) analyzer provided very rapid analysis of this relatively complex matrix. Full spectral information in the range of m/z 35-450 was collected across the short GC run (less than 5 min). Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS) 50/30 microm fiber performed best during the optimization experiments and it was used in the headspace SPME mode to isolate compounds from ice wine samples, consisting of 3 mL wine with 1g salt addition. After the sample incubation and extraction (both 5 min at 45 degrees C), analytes were thermally desorbed in the GC injector for 2 min (injector maintained at 260 degrees C) and transferred into the column. The MS data acquisition rate of 50 spectra/s was selected as optimal. The optimized analytical method did not exceed 20 min per sample, including both the isolation and pre-concentration of the analytes of interest, the final GC-TOF-MS analysis and the fiber bake-out. Both a linear temperature-programmed retention index (LTPRI) method using C(8)-C(20) alkanes loaded onto the fiber and a mass spectral library search were employed to identify the target compounds. The repeatability of the developed and optimized HS-SPME-GC-TOF-MS method for ice wine analysis, expressed as relative standard deviation (RSD, %, n=7), ranged from 3.2 to 9.0%.  相似文献   

15.
A rapid HPLC-diode array detection (DAD) method was developed for the routine analysis of 16 anthocyanins in wine. Direct injection of filtered wine samples followed by selective detection at 520 nm allowed quantitation of these compounds in red wines. The method was linear for malvidin-3-glucoside over the range 5-250ppm, and the limit of detection for this compound was 0.18 ppm. A volatile mobile phase is used, which enables hyphenation to mass spectrometry (MS). With HPLC-MS, a total of 44 pigments could be identified in South African wines. Obtained mass spectra are discussed for a series of representative wine constituents and results are compared with literature references. An attempt was made to differentiate between different cultivars according to the anthocyanin content using stepwise forward linear discriminant analysis (LDA).  相似文献   

16.
A compound associated with oxidized flavor in red wines was recently-identified as 3-methyl-2,4-nonanedione (MND). In order to quantify it, positive chemical ionization (PCI) in an ion trap was studied using conventional liquid reagents such as methanol, acetonitrile, and acetone, as well as non-conventional liquid reagents such as ethyl acetate, diethyl ether, pentane, isohexane, and heptane. Under laboratory conditions, very different response factors were obtained with MND depending on the gas. We also compared the detection limit of conventional CI with hybrid chemical ionization (HCI). Finally, this compound was quantified in red wines by liquid/liquid extraction without any derivatization steps, followed by GC/MS-CI analysis, using methanol as the reagent gas. Coelutions of compounds with the same m/z were checked using methanol-d(4). The method we developed was linear in the 10-300 ng/L range of MND concentrations, with satisfactory repeatability. The detection limit was 4.3 ng/L, over 3 times lower than the olfactory perception threshold of this compound (16 ng/L). The suitability of this method for assaying this diketone in red wine was demonstrated by the analyzing many wines from different vintages.  相似文献   

17.
A new analytical method, using gas chromatography-mass spectrometry (GC/MS) and liquid chromatography-mass spectrometry (LC/MS) techniques, was developed for the determination in packaged food beverages of five ink photoinitiator residues: 2-isopropylthioxanthone (ITX), benzophenone, 2-ethylhexyl-4-dimethylaminobenzoate (EHDAB), 1-hydroxycyclohexyl-1-phenyl ketone (IRGACURE 184) and ethyl-4-dimethylaminobenzoate (EDAB). Samples were extracted from selected beverages (milk, fruit juices and wine) and relative packagings, using n-hexane and dichloromethane, respectively, purified on solid-phase extraction (SPE) silica gel cartridges, and then analyzed in GC/MS and LC/MS. The recovery percentages, obtained spiking the beverage samples at concentrations of 4 and 10 microgl(-1) with a standard mixture of photoinitiators, were in the range 42-108% (milk), 50-84% (wine), and 48-109% (fruit juices). The repeatability of the method was assessed in all cases by the % of correlation value, that was lower than 19%. The lowest limits of detection (LODs) and limits of quantification (LOQs), obtained using GC/MS, were in the range 0.2-1 and 1-5 microgl(-1), respectively. The method was applied to the analysis of forty packaged food beverages (milk, fruit juices and wine samples). The most significant contamination was that of benzophenone, found in all samples in a concentration range of 5-217mugl(-1). Its presence was confirmed by an LC/Atmospheric-Pressure PhotoIonization (APPI)/MS/MS analysis. The photoinitiator (EHDAB) was found in eleven out of forty beverages in a concentration range of 0.13-0.8 microgl(-1). Less important was the ITX contamination, found in three out of forty samples in a range 0.2-0.24 microgl(-1). The work proposes a new method to analyze ink photoinitiator residues in polycoupled carton packaging and in contained food beverages.  相似文献   

18.
The previously developed and optimized headspace solid-phase microextraction (HS-SPME)-GC-time-of-flight (TOF) MS analytical method for the determination of compounds with a wide range of polarities and volatilities was successfully used in this study to characterize and classify a large set of ice wines according to their origin, grape variety and oak or stainless steel fermentation/ageing conditions, based on a statistical evaluation (principal component analysis (PCA)) of the measured data. More than 130 ice wine samples collected directly from Canadian and Czech wine producers were analyzed in this study. The SPME step was beneficially carried out utilizing the new-generation super elastic divinylbenzene/Carboxen/polydimethylsiloxane (DVB/CAR/PDMS) 50 microm/30 microm fiber assembly. One fiber was used for the whole sequence of ice wine samples, control and blank experiments, which consisted of more than 600 individual extraction/injection cycles. Utilizing the high-speed TOF analyzer, full spectral information within the range of 35-450 u was collected for the entire GC run (as short as 4.5 min) without compromising in the detection sensitivity, as compared to other scanning mass analyzers operated in selected ion monitoring or MS(n) mode to achieve similar sensitivity. The identification of analytes was performed by a combination of the linear temperature-programmed retention index (LTPRI) approach with the comparison of the obtained spectra with three libraries included in the ChromaTOF software. A total of 201 peaks were tentatively assigned as ice wine aroma components and 58 of those compounds were evaluated in all of the examined samples.  相似文献   

19.
A solid-phase microextraction (SMPE) method coupled to a gas chromatography–mass spectrometry analysis was optimized to analyze the pentafluorobenzyl bromide (PFBBr) derivatives of the volatile thiols 4-methyl-4-mercapto-2-pentanone (4MMP), 3-mercaptohexyl acetate (3MHA) and 3-mercaptohexanol (3MH) in wine. This method used deuterated analogue compounds as internal standards. It allowed us to significantly reduce the matrix effect, resulted in good repeatability for all the compounds (RDS < 9.5% for 4MMP; <6% for 3MH and <4.1% for 3MHA) with limits of detection below their odour thresholds. The method was validated using white, rosé and red wines. When applied to analyze different wines, quantities closed to the odour threshold were determined.  相似文献   

20.
Multiple HS-solid-phase microextraction (MHS-SPME) is a modification of SPME developed for quantitative analysis that avoids possible matrix effects based on an exhaustive analyte extraction from the sample. In this paper, the theory of this process associated with a non-equilibrium situation has been presented. The application of an optimised HS-SPME-based method in the analysis of chloroanisoles and chlorophenols, previously acetylated, associated with the occurrence of cork taint in different red, white and rosé wine samples, has revealed the existence of matrix effects. This fact determines the choice of standard addition as the adequate technique for the quantification of these compounds in real samples. MHS-SPME is proposed as a good alternative technique with respect to HS-SPME because it avoids matrix effects, simplifies the quantification of these compounds in real samples and reduces analysis time, providing sensitivity below chloroanisole sensory threshold with acceptable precision.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号