首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensitive and simple HPLC method has been developed and validated for the determination of oxyresveratrol (trans-2,4,3',5'-tetrahydroxystilbene, OXY) and resveratrol (trans-3,5,4'-trihydroxystilbene, RES) in rat plasma. The plasma samples were extracted with ethyl acetate and analyzed using HPLC on an Aglient Zorbax SB-C(18) column (250 x 4.6 mm, 5 microm) at a wavelength 320 nm, with a linear gradient of (A) acetonitrile and (B) 0.5% aqueous acetic acid (v/v), at a flow rate of 1.0 mL/min. The method was linear over the range of 0.1265-25.3 microg/mL for OXY and 0.117-23.4 microg/mL for RES. The extraction recovery for OXY, RES and internal standard ranged from 71.1 to 88.3%. The intra- and inter-day precisions were better than 10%, and the accuracy ranged from 89 to 108%. The validated method was used to study the pharmacokinetic profiles of OXY and RES in rat plasma after oral administration of Smilax china root extract.  相似文献   

2.
An ultra‐performance liquid chromatography tandem mass spectrometry method was developed for the simultaneous determination of protocatechuic acid, catechin, gallocatechin and formononetin in rat plasma, with genkwanin as the internal standard in this study. Plasma samples were prepared by liquid–liquid extraction with ethyl acetate. The four components were separated on an Agilent Zorbax Eclipse Plus C18 column (2.1 × 50 mm, 1.8 μm) with the mobile phase consisting of water containing 0.05% formic acid and methanol (35:65, v/v), and detected by negative ion electrospray ionization in the selected reaction monitoring mode. The method was linear for all analytes over the investigated ranges, with all correlation coefficients >0.99. The validated lower limit of quantification was 0.5 ng/mL for protocatechuic acid, catechin, and gallocatechin and 0.8 ng/mL for formononetin. The intra‐ and inter‐day precisions (RSD, %) were <13.1%, and accuracy (RE, %) ranged from ?13.8 to 9.9%. The mean absolute extraction recoveries of the analytes and internal standard from rat plasma were all >80.7%. The validated method was successfully applied for the first time to investigate the pharmacokinetics of four chemical ingredients after oral administration of Caulis Spatholobi Extract in rats. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

3.
A rapid, simple and sensitive, liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method was developed and validated for simultaneous determination of bergenin, chlorogenic acid and four flavonoids in a QingGanSanJie preparation in rat plasma. Puerarin was selected as the internal standard (IS). Plasma samples were precipitated with methanol and separated with a reverse phase Agilent Poroshell 120 EC‐C18 column using a gradient mobile phase of methanol–water containing 0.1% formic acid (v/v). A triple quadruple mass spectrometer was used for quantification (limit of detection 0.36–5.55 ng/mL). Intra‐day and inter‐day precisions were within 15% and the average extraction recoveries ranged from 85 to 115% for each analyte. The method allowed simultaneous quantification for the first time of the pharmacokinetics of bergenin, chlorogenic acid and four flavonoids after intragastric administration of a QingGanSanJie extract in Sprague–Dawley rats. It was found that bergenin and chlorogenic acid had typical extravascular administration concentration–time curves; flavonoids had a bimodal distribution improving bioavailability and extending the pharmacodynamics period. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

4.
A rapid, sensitive and specific high-performance liquid chromatography/electrospray ionization mass spectrometric (LC-ESI-MS) method was developed and validated for the quantification of madecassoside, a major active constituent of Centella asiatica (L.) Urb. herbs, in rat plasma. With paeoniflorin as an internal standard (IS), a simple liquid-liquid extraction process was employed for the plasma sample preparation. Chromatographic separation was achieved within 6 min on a Shim-pack CLC-ODS column using acetonitrile and water (60:40, v/v) containing 0.1% (v/v) formic acid as the mobile phase. The detection was performed by MS with electrospray ionization interface in negative selected ion monitoring (SIM) mode. The linear range was 11-5500 ng/mL with the square regression coefficient (r(2) ) of 0.9995. The lower limit of quantification was 11 ng/mL. The intra- and inter- day precision ranged from 4.99 to 9.03%, and the accuracy was between 95.82 and 111.80%. The average recoveries of madecassoside and IS from spiked plasma samples were >92%. The developed method was successfully applied to the pharmacokinetic study of madecassoside in rats after an oral administration.  相似文献   

5.
A simple HPLC method was developed for determination of quercitrin and isoquercitrin in rat plasma. Reversed-phase HPLC was employed for the quantitative analysis using kaempferol-3-O-beta-D-glucopyranoside-7-O-alpha-L-rhamnoside as an internal standard. Following extraction from the plasma samples with ethyl acetate-isopropanol (95:5, v/v), these two compounds were successfully separated on a Luna C(18) column (250 x 4.6 mm, 5 microm) with isocratic elution of acetonitrile-0.5% aqueous acetic acid (17:83, v/v) as the mobile phase. The flow-rate was set at 1 mL/min and the eluent was detected at 350 nm for both quercitrin and isoquercitrin. The method was linear over the studied ranges of 50-6000 and 50-5000 ng/mL for quercitrin and isoquercitrin, respectively. The intra- and inter-day precisions of the analysis were better than 13.1 and 13.2%, respectively. The lower limits of quantitation for quercitrin and isoquercitrin in plasma were both of 50 ng/mL. The mean extraction recoveries were 73 and 61% for quercitrin and isoquercitrin, respectively. The validated method was successfully applied to pharmacokinetic studies of the two analytes in rat plasma after the oral administration of Hypericum japonicum thunb. ethanol extract.  相似文献   

6.
Osthole, a major component isolated from the fruit of Cnidium monnieri (L.) Cusson, has been widely used in traditional Chinese medicine. We developed and validated a rapid and sensitive LC‐MS/MS method for the quantification of osthole in rat plasma. Sample preparation involved simple liquid–liquid extraction by ethyl acetate after addition of imperatorin as internal standard (IS). The analyte was separated using a C18 column with the mobile phase of methanol–0.1% formic acid (80:20, v/v) at a flow rate of 0.4 mL/min. The elutes were detected under positive electrospray ionization in multiple reaction monitoring mode. The method was sensitive with 0.5 ng/mL as the lower limit of detection. Good linearity was obtained over the range of 1.0–500.0 ng/mL. The intra and inter‐batch accuracy for osthole in rat plasma samples ranged from 99.5 to 108.1% and the variation was <8.9%. The stability, extraction efficiency and matrix effect were also acceptable. This method was successfully applied to the pharmacokinetic study of osthole in rat after intravenous and oral administration. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

7.
A sensitive and selective high-performance liquid chromatography method was developed and validated to determine the prototype of salvianolic acid B and the metabolites of phenolic acids (protocatechuic acid, vanillic acid and ferulic acid) in rat tissues after oral administration of total phenolic acids and salvianolic acid B extracted from the roots of Salvia miltiorrhiza, respectively. The tissue samples were treated with a simple liquid-liquid extraction prior to HPLC. Analysis of the extract was performed on a reverse-phase C(18) column with a mobile phase consisting of acetonitrile and 0.05% trifluoracetic acid. The calibration curves for the four phenolic acids were linear in the given concentration ranges. The intra-day and inter-day relative standard deviations in the measurement of quality control samples were less than 10% and the accuracies were in the range of 88-115%. The average recoveries of all the tissues ranged from 78.0 to 111.8%. This method was successfully applied to evaluate the distribution of the four phenolic acids in rat tissues after oral administration of total phenolic acids of Salvia miltiorrhiza or salvianolic acid B and the possible metabolic pathway was illustrated.  相似文献   

8.
We developed a method for the simultaneous quantification of aceclofenac and its three major metabolites in rat plasma. After protein precipitation with acetonitrile including flufenamic acid as an internal standard (IS), aceclofenac, diclofenac, 4'-hydroxyaceclofenac, 4'-hydroxydiclofenac, and the IS were chromatographed on a reverse-phase C18 analytical column. The isocratic mobile phase of acetonitrile/0.1% formic acid (aq; 9:1 [v/v]) was eluted at 0.3 mL/min. Quantification was performed on a triple-quadrupole mass spectrometer using electrospray ionization, and the ion transitions were monitored in selective reaction-monitoring mode. The coefficient of variation in the assay precision was less than 8%, and the accuracy was 92-103%. This method was successfully used to measure the concentrations of aceclofenac and its three major metabolites in rat plasma following the oral administration of a single 20 mg/kg oral dose of aceclofenac.  相似文献   

9.
This study aimed to develop a specific UHPLC‐ESI‐MS/MS method for simultaneous determination and pharmacokinetics of pinoresinol glucoside and chlorogenic acid in rat plasma after oral administration of Eucommia ulmoides . The chromatographic separation was achieved on a Hypersil GOLD column with gradient elution by using a mixture of 0.1% formic acid aqueous solution and acetonitrile as the mobile phase at a flow rate of 200 μL/min. A tandem mass spectrometric detection was conducted using multiple‐reaction monitoring via an electrospray ionization source in negative ionization mode. Samples were pre‐treated by a single‐step protein precipitation with acetonitrile, and bergenin was used as internal standard. After oral administration of 3 mL/kg E. ulmoides extract in rats, the maximum plasma concentrations of pinoresinol glucoside and chlorogenic acid were 57.44 and 61.04 ng/mL, respectively. The times to reach the maximum plasma concentration were 40.00 and 23.33 min for pinoresinol glucoside and chlorogenic acid, respectively. The intra‐ and inter‐day precision (RSD) values for the two analytes were <2.46 and 5.15%, respectively, and the accuracy (RE) values ranged from −12.76 to 0.00. This is the first study on pharmacokinetics of bioactive compounds in rat plasma after oral administration of E. ulmoides extract.  相似文献   

10.
A simple and specific high-performance liquid chromatography (HPLC) method was developed for the pharmacokinetic study of vitexin-4″-O-glucoside (VOG) in rats after oral administration. The plasma samples were deproteinised with methanol after the addition of an internal standard, hesperidin. HPLC analysis was performed on a Diamonsil C(18) analytical column, using methanol -0.5% aqueous phosphoric acid (45:55, v/v) as the mobile phase with ultraviolet detection at 330?nm. The calibration curve was linear over the range of 5-450?μg?mL(-1) in rat plasma. The average extraction recovery of VOG was 98.74%?±?0.44%, and the relative standard deviations of the intra- and inter-day precisions were not greater than 4.1% and 2.0%, respectively. The validated method was successfully applied during a pharmacokinetic study in rats after oral administration of VOG at different doses, and all the results indicated that the pharmacokinetics of VOG in rats obeyed nonlinear processes.  相似文献   

11.
A simple and sensitive high-performance liquid chromatographic (HPLC) method is developed for the determination of osthole in rat plasma and applied to a pharmacokinetic study in rats after administration of Fructus Cnidii extract. After addition of fluocinonide as an internal standard, plasma samples are extracted with diethyl ether. HPLC analysis of the extracts is performed on a Hypersil ODS2 analytical column, using methanol-0.4% acetic acid (65:35, v/v) as the mobile phase. The UV detector is set at 322 nm. The standard curve is linear over the range 0.0520-5.20 microg/mL (r = 0.9979). The mean extraction recoveries of osthole at three concentrations were 81.0%, 91.2%, and 90.7%, respectively. The intra- and interday precisions have relative standard deviations from 1.9% to 4.9%. The limit of quantitation is 0.0520 microg/mL. The HPLC method developed can easily be applied to the determination and pharmacokinetic study of osthole in rat plasma after the animals are given the Fructus Cnidii extract. The plasma concentration of osthole from six rats showed a Cmax of 0.776 +/- 0.069 microg/mL at Tmax of 1.0 +/- 0.3 h.  相似文献   

12.
A sensitive liquid chromatography–electrospray ionization–mass spectrometry method has been developed and validated for determination of two major bioactive saponins in rat plasma after oral administration of saponins extracted from Rhizoma Panacis Japonici, including chikusetsusaponin V and chikusetsusaponin IV for the first time. Akebia saponin D was used as the internal standard (IS). Plasma samples were prepared by protein precipitation with methanol. A Phenomenex C18 column (150 × 4.6 mm, 4 µm) was used as the analytical column with a mobile phase of acetonitrile and 0.05% aqueous formic acid. Mass spectrometric detection was achieved by single quadrupole mass spectrometer equipped with an electrospray ionization interface operating in negative ionization mode. Calibration curves showed good linearity over the concentration range of 5–500 ng/mL for the two analytes in rat plasma. The lower limit of quantification was 5 ng/mL. The intra‐ and inter‐batch precisions were within 10.3% and accuracy ranged from ?3.9 to 5.4%. The method was validated and successfully applied to the preliminary pharmacokinetic study of chikusetsusaponin V and chikusetsusaponin IV in rat plasma after oral administration of saponins extracted from Rhizoma Panacis Japonici. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

13.
A selective and sensitive liquid chromatography tandem mass spectrometry method was developed for the simultaneous determination of salviaflaside and rosmarinic acid in rat plasma. Sample preparation was carried out through liquid–liquid extraction with ethyl acetate using curculigoside as internal standard (IS). The analytes were determined by selected reaction monitoring operated in the positive ESI mode. Chromatographic separation was performed on an Agilent Eclipse Plus C18 column (100 × 4.6 mm, 1.8 μm) with a mobile phase consisting of methanol–water–formic acid (50:50:0.1, v/v/v) at a flow rate of 0.3 mL/min. The run time was 1.9 min per sample and the injection volume was 5 μL. The method had an LLOQ of 1.6 ng/mL for salviaflaside and 0.94 ng/mL for rosmarinic acid in plasma. The linear calibration curves were fitted over the range of 1.6–320 ng/mL for salviaflaside and 0.94–188 ng/mL for rosmarinic acid in plasma with correlation coefficients (r2) >0.99. Intra‐ and inter‐day precisions (relative standard deviation) were < 13.5%, and accuracies (relative error) were between −8.6% and 14.5% for all quality control samples. The method was validated and applied to the pharmacokinetics of salviaflaside and rosmarinic acid in plasma after oral administration of Prunella vulgaris extract to rats.  相似文献   

14.
A simple, rapid, sensitive and specific liquid chromatography/electrospray ionization mass spectrometry method was developed and validated to quantify azithromycin in human plasma, using erythromycin as the internal standard (IS). A simple sample preparation method of protein precipitation with methanol was employed. Methanol, acetonitrile and water (12:30:58, v/v/v) were used as the isocratic mobile phase, with 0.1% formic acid and 0.1% ammonium acetate in water. Selected ion monitoring was specific for azithromycin and erythromycin. The assay was linear over the concentration range 4.69-600 ng/mL. The correlation coefficients for the calibration curves ranged from 0.9994 to 0.9998. The intra- and inter-day precisions, calculated from quality control samples, were less than 8.24%. The method was employed in a pharmacokinetic study after oral administration of 500 mg azithromycin dispersible tablet to 20 healthy volunteers.  相似文献   

15.
An HPLC method is described for determination of ferulic acid in rat plasma. The concentration of ferulic acid in rat plasma was determined after deproteinization with acetonitrile using sulfamethoxazole as internal standard. Chromatographic separations were performed on a C(18) stationary phase with a mobile phase composed of acetonitrile-water (16:84, v/v) with 1% glacial acetic acid. The UV detection wavelength was set at 320 nm. The method was successfully applied to the determination of pharmacokinetic parameters in rat plasma after oral administration of Rhizoma Chuanxiong and and its compound preparation Suanzaoren decoctions. The calibration curve was linear over the range 0.0510-4.08 micro g/mL in rat plasma. Within-day and between-day precisions were less than 4.5% RSD. Mean recovery was determined as 96.9%. The limit of quantitation was 0.0510 micro g/mL. The pharmacokinetic parameters of the two preparations were different significantly (p < 0.05), which may attribute to the effects of other ingredients present in Suanzaoren decoction.  相似文献   

16.
Liquid chromatography–electrospray ionization tandem mass spectrometry has been used for rapid, selective, and sensitive quantitative analysis of gallic acid in rat plasma. Sample pretreatment involved a one-step extraction using ethyl acetate with protocatechic acid as internal standard. Separation was on a C18 column using an isocratic mobile phase, consisting of methanol-0.1% aqueous formic acid (40:60, v/v) at 0.2 mL min?1. The stability of gallic acid was evaluated in acidified and non-acidified plasma. The method was validated then successfully applied to a pharmacokinetic study in rats after oral administration of rhubarb extract.  相似文献   

17.
A rapid, sensitive and selective liquid chromatography-tandem spectrometry method was developed and validated for determination of paeoniflorin in rat plasma using geniposide as the internal standard. The samples were pretreated with solid-phase extraction using Extract-Clean cartridges. Separation of paeoniflorin and IS was achieved on a reversed-phase C18 column (50x4.6 mm i.d.) with a mobile phase made up of acetonitrile and 0.05% formic acid (25:75, v/v) at a flow rate of 0.5 mL/min. Detection was carried out on a triple quadrupole tandem mass spectrometer by multiple-reaction monitoring and an electrospray ionization source was employed as the ionization source. The lower limit of quantification obtained was 4 ng/mL (n=6) using 200 microL plasma with an accuracy of -3.67% (relative error) and a precision of 4.13% (relative standard deviation). A good linearity was found in the range of 4-1000 ng/mL. The intra- and inter-day relative standard deviations in the measurement of quality control samples 10, 150 and 800 ng/mL ranged from 3.73 to 4.94% and from 4.31 to 6.56%, respectively. The accuracy was from -3.93 to -1.11% in terms of relative error. The analyte and IS were stable in the battery of stability studies. This method was successfully applied to a pharmacokinetic study of paeoniflorin after a single oral administration of 53.36 mg/kg paeoniflorin to rats.  相似文献   

18.
19.
In this work, a sensitive and selective ultra‐performance liquid chromatography–tandem mass spectrometry (UPLC‐MS/MS) method for determination of hupehenine in rat plasma was developed and validated. After addition of imperialine as an internal standard (IS), protein precipitation by acetonitrile–methanol (9:1, v/v) was used to prepare samples. Chromatographic separation was achieved on a UPLC BEH C18 column (2.1 × 100 mm, 1.7 µm) with 0.1% formic acid and acetonitrile as the mobile phase with gradient elution. An electrospray ionization source was applied and operated in positive ion mode; multiple reaction monitoring mode was used for quantification using target fragment ions m/z 416.3 → 98.0 for hupehenine, and m/z 430.3 → 138.2 for IS. Calibration plots were linear throughout the range 2–2000 ng/mL for hupehenine in rat plasma. Mean recoveries of hupehenine in rat plasma ranged from 92.5 to 97.3%. Relative standard deviations of intra‐day and inter‐day precision were both <6%. The accuracy of the method was between 92.7 and 107.4%. The method was successfully applied to a pharmacokinetic study of hupehenine after either oral or intravenous administration. For the first time, the bioavailability of hupehenine was reported as 13.4%. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

20.
A simple, rapid and accurate HPLC method has been developed for simultaneous determination of hydroxysafflor yellow A and ferulic acid in rat plasma after oral administration of the co-extractum of Rhizoma chuanxiong and Flos Carthami. Plasma samples were deproteinized with 6% perchloric acid, and riboflavin was used as internal standard. The supernatant after centrifuge was injected into a Shimadzu C(18) (150 x 4.6 mm, i.d. 5 microm) column. Gradient elution for A:B (0 min, 90:10; 25 min, 70:30; 27 min, stop) was applied. The mobile phase was composed of 0.022 mol/L potassium dihydrogen phosphate solutions, adjusted to pH 3.0 with phosphoric acid for pump A, and 90% (v/v) acetonitrile for pump B. The assay was shown to be linear over the range 0.046-4.6 microg/mL (r(2) = 0.9995) for hydroxysafflor yellow A and 0.037-3.7 microg/mL (r(2) = 0.9998) for ferulic acid. Mean recovery was 97.5% for hydroxysafflor yellow A and 83.6% for ferulic acid. Both of the intra-day and inter-day precisions were 相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号