首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 73 毫秒
1.
A simple flow injection chemiluminescence (CL) method was developed for the determination of atenolol using Eu3+ as the probe. It was found that the weak CL generated by the KMnO4-Na2SO3 reaction can be significantly enhanced by the atenolol-Eu3+ complex. The experimental conditions were optimized. The CL intensity was linearly related to atenolol concentration in the range from 8.0 × 10−9 to 1.0 × 10−5 g mL−1. The detection limit (3s b) was 3 × 10−9 g mL−1 and the relative standard deviation for 1.0 × 10−7 g mL−1 atenolol solution was 2.4% (n = 11). The method has high sensitivity, wide linear range, inexpensive instrumentation, and has been applied to the determination of atenolol in spiked human urine and plasma samples with recoveries within the range 95.5–104.0%. Supplementary material to this paper is available in electronic form at Electronic supplementary material: Discussion of the reaction mechanism and additional figures are available online as electronic supplementary material (ESM) at . Correspondence: Jianxiu Du, Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Materials Science, Shaanxi Normal University, Xi’an 710062, P.R. China  相似文献   

2.
 Yttrium was determined by means of the resonance light scattering (RLS) technique. The characteristics of resonance light scattering spectra of yttrium-1, 6-bi(1′-phenyl-3′-methyl-5′-pyrazolone-4′-) hexanedione (BPMPHD), the effective factors and optimum conditions were studied. In the pH range of 5.0–6.1, yttrium-BPMPHD complex produces three characteristic peaks of RLS at 365, 402 and 467 nm. The enhanced intensity of RLS is proportional to the concentration of yttrium in the range of 1.0×10−8 to 1.0×10−5 mol · L−1. The limit of detection is 5.9×10−9 mol · L−1. The method has been used for the determination of Y3+ in mixed rare earths. Correspondence: Key Lab for Colloid and Interface Chemistry of Education Ministry, School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100, People’s Republic of China. e-mail: wux@sdu.edu.cn Received July 3, 2002; accepted October 20, 2002  相似文献   

3.
A square wave adsorptive stripping voltammetric (SWAdSV) method was developed for the determination of proflavine. The electrochemical behaviour of proflavine was investigated by cyclic (CV) and square wave voltammetry (SWV) at the hanging mercury drop electrode (HMDE) and carbon paste electrode (CPE). Different parameters were tested to optimize the conditions of the determination. Better results were obtained by square wave voltammetry using CPE where two oxidation and a reduction peak, appeared, at 0.19, 0.94 and 0.20 V, respectively. The peak at 0.19 V is quasi-reversible and deposition dependent. Linearity was observed in the range of (0.2–23.4) × 10−8 M (r = 0.998) during the anodic scan and in the range of (1.17–117) × 10−8 M (r = 0.999) during the cathodic scan. The second peak at 0.94 V is irreversible and deposition independent. The linearity of this peak was observed in the range of (1.29–11.7) × 10−8 M (r = 0.998). The method was applied to the analysis of bovine serum and gave satisfactory results. Correspondence: S. Th. Girousi, Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University, Thessaloniki 54124, Greece  相似文献   

4.
Perovskite-type compounds, Li x La(1− x )/3NbO3 and (Li0.25La0.25)1− x Sr0.5 x NbO3 as lithium ionic conductors, were synthesized by a solid-state reaction. From powder X-ray diffraction, the solid solution ranges of the two compounds were determined to be 0≤x≤0.25 and 0≤x≤0.125, respectively. In the Li x La(1− x )/3NbO3 system, the ionic conductivity of lithium at room temperature, σ25, exhibited a maximum value of 4.7 × 10−5 S · cm−1 at x = 0.10. However, because of the decrease in the lattice parameters with increasing Li concentration , σ25 of the samples decreased with increasing x from 0.10 to 0.25. Also, in the (Li0.25La0.25)1− x Sr0.5 x NbO3 system, the lattice parameter increased with the increase of Sr concentration and the σ25 achieved a maximum (7.3 × 10−5 S · cm−1 at 25 °C) at x = 0.125. Received: 12 September 1997 / Accepted: 15 November 1997  相似文献   

5.
 It was found that the hypericinate salts of (R)-1-phenylethylamine and (S)-1-(1-naphthyl)-ethylamine display a small chiroptical signal of the same sign only at high concentrations in an apolar solvent. No further indications of a chiral discrimination between the helical conformers of hypericinate could be found in these cases. However, upon esterification of the 3-hydroxyl group of hypericin with (1S)-camphanic chloride, the two diastereomers were found in an 1:1 ratio equilibrating rather fast at temperatures above 30°C with one diastereomer in excess. From the temperature dependence of the equilibrium positions (measured by means of CD and 1H NMR), a ΔG 0 value of 5.8±0.5 kJ·mol−1 was derived. Accordingly, the chiral discrimination of the (M)-configured enantiomer of the helix by the (S)-configured auxiliary occurred at an intermediate level. From the temperature dependence of the equilibration kinetics an activation energy of E a = 70±0.5 kJ·mol−1 was derived, which thus defines the upper limit of the helix inversion of hypericin and hypericinate. This value is by about 10 kJ·mol−1 lower than the recently estimated limit.  相似文献   

6.
This work describes a new analytical procedure for trace vanadium by graphite furnace atomic absorption spectroscopy coupled to cloud point extraction (CPE) as the separation-preconcentration method. The CPE behavior of vanadium using methylene blue as complex agent and Triton X-100 as a surfactant was investigated systematically. Under the optimized conditions, the detection limit was 0.7 ng · mL−1, and the relative standard deviation was 4.3% for vanadium (c = 50.0 ng · mL−1, n = 5). The recovery of vanadium was in the range of 98.9–102.8%. The method was applied to the analysis of vanadium in certified reference materials and real samples. The results obtained were in good agreement with the certified values. Correspondence: Xiashi Zhu, Key Laboratory of Environmental Material and Environmental Engineering of Jiangsu province/College of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou 225002, P.R. China  相似文献   

7.
Summary.  It was found that the hypericinate salts of (R)-1-phenylethylamine and (S)-1-(1-naphthyl)-ethylamine display a small chiroptical signal of the same sign only at high concentrations in an apolar solvent. No further indications of a chiral discrimination between the helical conformers of hypericinate could be found in these cases. However, upon esterification of the 3-hydroxyl group of hypericin with (1S)-camphanic chloride, the two diastereomers were found in an 1:1 ratio equilibrating rather fast at temperatures above 30°C with one diastereomer in excess. From the temperature dependence of the equilibrium positions (measured by means of CD and 1H NMR), a ΔG 0 value of 5.8±0.5 kJ·mol−1 was derived. Accordingly, the chiral discrimination of the (M)-configured enantiomer of the helix by the (S)-configured auxiliary occurred at an intermediate level. From the temperature dependence of the equilibration kinetics an activation energy of E a = 70±0.5 kJ·mol−1 was derived, which thus defines the upper limit of the helix inversion of hypericin and hypericinate. This value is by about 10 kJ·mol−1 lower than the recently estimated limit. Corresponding author. E-mail: heinz.falk@jku.at Received March 22, 2002; accepted April 3, 2002  相似文献   

8.
A new Schiff-base ligand [N, N′, N″-Tri- (2,4-dihydroxyacetophenone) – triaminotriethylamine (TDATA)] with a tripodal structure was synthesized. Its fluorescence intensity with the europium(III) complex was increased about 178-fold in the presence of sodium acetate (NaAc) and about 126-fold in the presence of sodium phosphate (Na3PO4) solution. After adding the organic solvent dimethylsulfoxide (DMSO) to the above system, which leads to Eu3+ the fluorescence was further enhanced about 12-fold. Spectrofluorimetric determination of trace amounts of Eu3+ based on the phenomenon was performed. The excitation and emission wavelength is 365 nm and 615 nm, respectively. Under optimum conditions, the fluorescence intensities vary linearly with the concentration of Eu3+ in the range of 4.9 × 10−12–3.2 × 10−6 mol · L−1 with a detection limit of 4.5 × 10−12 mol · L−1 (for the TDATA-NaAc-DMSO system) or 6.2 × 10−11–8.6 × 10−6 mol · L−1 with a detection limit of 6.0 × 10−11 mol · L−1 (for the TDATA-Na3PO4-DMSO system). Interferences of some rare earth metals and other inorganic ions are described. The method is a selective, sensitive, rapid and simple analytical procedure for the determination of europium(III) in a high purity yttrium oxide and synthetic sample. The mechanism for the fluorescence enhancement is also discussed.  相似文献   

9.
An ensemble of carbon fibers ultra-microelectrode modified with carbon nanotubes (EUME-CNTS) has been constructed based on a thin carbon nanotubes film which was coated onto surfaces of carbon fibers of ultra-microelectrode. SEM micrographs illustrated the image of carbon nanotubes on the carbon fiber surface. The electrochemical characteristics of the EUME-CNTS has been investigated by cyclic voltammetry. The electrochemical properties of dopamine on this electrode were also studied, and the detection limit was found to be 2.0 × 10−9 mol·L−1. Linear calibration plots were obtained for the oxidation peak current in a range 1.0 × 10−7–8.0 × 10−5 mol·L−1. Correspondence: Xiuhua Liu, Kuaizhi Liu, Department of Chemistry and Chemical Engineering, Henan University, Henan Kaifeng 475001, P.R. China  相似文献   

10.
A novel flow injection procedure has been developed for the determination of tannic acid based on the inhibition of the chemiluminescences in luminol-H2O2-Manganese tetrasulfonatophthalocyanine (MnTSPc) system by tannic acid. The method is simple, rapid and sensitive with a detection limit of 8 × 10−10 mol·L−1 and a linear range of 7 × 10−9–5 × 10−6 mol·L−1. The relative standard deviation is 1.9% for eleven measurements of 5 × 10−7 mol·L−1 tannic acid. The method has been successfully applied to the determination of tannic acid in real Chinese gall and hop pellets samples.  相似文献   

11.
A kinetic-potentiometric method is described for the quantitative assay of formaldehyde (HCHO) in pharmaceutical and industrial preparations. It is based on the reaction of HCHO with (ethylenediamine)-Cu(II)-sulfate [Cu(CH2NH2)2(H2O)2] · SO4. The changes in potential, resulting from the release of the Cu(II) cations, are monitored with a Cu(II)-ion selective electrode. The calibration curve for the HCHO is linear in the concentration range 50–250 mg L−1, with a limit of detection of 8.5 mg L−1. The method shows very good reproducibility with an RSD of 2.6% for successive injections (n = 5) of 150 mg L−1 HCHO primary solution, while it is interference free. The method was successfully tested in various industrial and pharmaceutical preparations.  相似文献   

12.
CeO2 nanoparticles approximately 12 nm in size were synthesized and subsequently characterized by XRD, TEM and UV-vis spectroscopy. Then, a gold electrode modified with CeO2 nanoparticles was constructed and characterized by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). The modified electrode demonstrated strong catalytic effects with high stability towards electrochemical oxidation of rutin. The anodic peak currents (measured by differential pulse voltammetry) increased linearly with the concentration of rutin in the range of 5.0 × 10−7–5.0 × 10−4 mol · L−1. The detection limit (S/N = 3) was 2.0 × 10−7 mol · L−1. The relative standard deviation (RSD) of 8 successive scans was 3.7% for 5.0 × 10−6 mol · L−1 rutin. The method showed excellent sensitivity and stability, and the determination of rutin in tablets was satisfactory.  相似文献   

13.
Vesuvianite, a complex sorosilicate, often contains variable (from trace-to-minor-element) amounts of H, B and F. We describe a microanalytical study of H, B and F in vesuvianite by means of Electron Probe Microanalysis (EPMA), Secondary Ion Mass Spectrometry (SIMS), and single-crystal Fourier-Transform InfraRed (FTIR) spectroscopy. Most crystals investigated are B- (up to 3.67 wt% B2O3) and F-rich (up to 2.38 wt%); H2O ranges from 0.243 to 0.665 wt%. The H data obtained by SIMS allowed us to calibrate the quantitative analysis of H2O by FTIR spectroscopy. The resulting molar absorption coefficient (ɛ i = 100 000 ± 2000 L · mol−1 · cm−2) is in excellent agreement with working curves available from the literature. Moreover, the SIMS data allowed us to obtain the calibration curve to estimate the B2O3 content on the basis on the FTIR absorbance: a i = 34000 ± 1400 · B2O3 (wt%).  相似文献   

14.
A sensitive adsorptive anodic stripping procedure for the determination of trace zirconium at a carbon paste electrode (CPE) has been developed. The method is based on adsorptive accumulation of the Zr(IV)-alizarin red S(ARS) complex onto the surface of the CPE, followed by oxidation of adsorbed species. The optimal experimental conditions include the use of 0.10 mol · L−1 ammonium acetate buffer (pH 4.3), ARS, an accumulation potential of 0.20 V (versus SCE), an accumulation time of 2 min, a scan rate of 200 mV · s−1 and a second-order derivative linear scan mode. The oxidation peak for the complex appears at 0.69 V. The peak current is proportional to the concentration of Zr(IV) over the range of 1.0 × 10−9–2.0 × 10−7 mol · L−1, and the detection limit is 3 × 10−10 mol · L−1 for a 2 min adsorption time. The relative standard deviations (n = 8) for 5.0 × 10−8 and 5.0 × 10−9 mol · L−1 Zr(IV) are 3.3 and 4.8%, respectively. The proposed method was applied to the determination of zirconium in ore samples with satisfactory results.  相似文献   

15.
The differential pulse (dp) polarograms of thiamine in neutral aqueous solutions exhibited six peaks at low depolarizer concentration (⋦10−4 mol dm−3) and only three peaks at concentrations ≥10−3 mol dm−3. Only one of these was found to correspond to the diffusion-controlled reduction of this compound at the dme and this was shown to be an irreversible two-electron process. The kinetic parameters derived from the dp polarograms were found to be in good agreement with those calculated from classical polarograms and were:E 1/2=−1·261 Vvs SCE,an a=0·54 andD≈3·5×10−6 cm2 sec−1 for 10−3 mol dm−3 thiamine in 0·1 mol dm−3 acetate buffer (pH 6·5). The reduction product has been identified as dihydrothiamine. The effect of pH on the dpp of thiamine was studied in the pH range 0–7. In the pH region 5·5 to 7·0 only one peak attributable to the B1 + form of thiamine is present. In the pH region 3·5–5·5 another dpp peak attributable to the protonated form (B1H2+) of thiamine was also observed. At pHs less than 3 only one peak was observed which could be attributed to the doubly protonated form (B1 H2 3+) of thiamine. Surfactants like triton-X-100 and CTABr were found to inhibit the electroreduction of thiamine due to the strong adsorption of these compounds on the dme. Thiamine itself was found to have an inhibitory effect on its own electroreduction, although to a smaller extent.  相似文献   

16.
Multilayer films of multiwalled carbon nanotubes (MWNTs) were homogeneously and stably assembled on a glassy carbon (GC) electrode using the layer-by-layer (LBL) method based on electrostatic interaction between MWNTs (negatively charged) and a biopolymer chitosan (CHIT) (positively charged). Scanning electron microscopy (SEM) image of the resulting {CHIT/MWNTs}9 film indicated that the substrate was mostly covered with MWNTs in the form of small bundles or single nanotubes. The multilayer film was used to study the electrocatalytic oxidation of NADH. The assembled {CHIT/MWNTs}9/GC electrode could decrease the oxidation overpotential of NADH by more than 350 mV. The {CHIT/MWNTs}9/GC electrode exhibited a wide linear response range of 8 × 10−7 to 1.6 × 10−3 mol · L−1 with a correlation coefficient of 0.997 for the detection of NADH. The response time and detection limit (S/N = 3) were determined to be 3 s and 0.3 × 10−6 mol · L−1, respectively. Another attractive characteristic was that the method was simple and the assembled {CHIT/MWNTs}9/GC electrode was highly stable.  相似文献   

17.
Functionalized polypyrrole films were prepared by incorporation of Fe(CN)6 3− as doping anion during the electropolymerization of pyrrole at a glassy carbon electrode from aqueous solution. The electrochemical behavior of the Fe(CN)6 3−/Fe(CN)6 4− redox couple in polypyrrole was studied by cyclic voltammetry. An obvious surface redox reaction was observed and dependence of this reaction on the solution pH was illustrated. The electrocatalytic ability of polypyrrole film with ferrocyanide incorporated was demonstrated by oxidation of ascorbic acid at the optimized pH of 4 in a glycine buffer. The catalytic effect for mediated oxidation of ascorbic acid was 300 mV and the bimolecular rate constant determined for surface coverage of 4.5 × 10−8 M cm−2 using rotating disk electrode voltammetry was 86 M−1 s−1. Furthermore, the catalytic oxidation current was linearly dependent on ascorbic acid concentration in the range 5 × 10−4–1.6 × 10−2 M with a correlation coefficient of 0.996. The plot of i p versus v 1/2 confirms the diffusion nature of the peak current i p. Received: 12 April 1999 / Accepted: 25 May 1999  相似文献   

18.
Summary.  The kinetics of the CrO(O2)2 formation by H2O2 and Cr2O7 2− in aqueous acidic media was measured at 293 ± 2 K in a pH range between 2.5 and 3.3. Using the stopped-flow method with rapid scan UV-VIS detection, the rate law of the formation of CrO(O2)2 was determined. For the media HClO4, HNO3 and CH3COOH, the reaction order in the Cr2O7 2− concentration was found to be 0.5. For [H2O2] as well as for [H+], the reaction was first order in all acids used. In HCl and H2SO4 media the reaction was first order in Cr2O7 2−. At T = 293 ± 2 K the rate constant for the formation of Cr(O)(O2)2 was found to be (7.3 ± 1.9) · 102 M−3/2 s−1 in HClO4. Corresponding author. E-mail: grampp@ptc.tu-graz.ac.at Received January 30, 2002; accepted (revised) June 5, 2002  相似文献   

19.
In the presence of carbonate and uranine, the chemiluminescent intensity from the reaction of luminol with hydrogen peroxide was dramatically enhanced in a basic medium. Based on this fact and coupled with the technique of flow-injection analysis, a highly sensitive method was developed for the determination of carbonate with a wide linear range. The method provided the determination of carbonate with a wide linear range of 1.0 × 10−10–5.0 × 10−6 mol L−1 and a low detection limit (S/N = 3) of carbonate of 1.2 × 10−11 mol L−1. The average relative standard deviation for 1.0 × 10−9–9.0 × 10−7 mol L−1 of carbonate was 3.7% (n = 11). Combined with the wet oxidation of potassium persulfate, the method was applied to the simultaneous determination of total inorganic carbon (TIC) and total organic carbon (TOC) in water. The linear ranges for TIC and TOC were 1.2 × 10−6–6.0 × 10−2 mg L−1 and 0.08–30 mg L−1 carbon, respectively. Recoveries of 97.4–106.4% for TIC and 96.0–98.5% for TOC were obtained by adding 5 or 50 mg L−1 of carbon to the water samples. The relative standard deviations (RSDs) were 2.6–4.8% for TIC and 4.6–6.6% for TOC (n = 5). The mechanism of the chemiluminescent reaction was also explored and a reasonable explanation about chemical energy transfer from luminol to uranine was proposed. Figure Chemiluminescence profiles in batch system. 1, Injection of 100 μL of K2CO3 into 1.0 mL luminol-1.0 mL H2O2 solution; 2-3 and 4-5, Injection in sequence of 100 μL of K2CO3 and 100 μL of uranine into 1.0 ml luminol-1.0 mL H2O2 solution; Cluminol = 1.0 × 10−7 mol/L, CH2O2 = 1.0 × 10−5 mol/L, Curanine = 1.0 × 10−5 mol/L, CK2CO3 = 1.0 × 10−7 mol/L except for 4-5 where CK2CO3 = 1.0 × 10−4 mol/L  相似文献   

20.
A method was developed for determining selenium with a self-made ion-selective electrode was developed. This electrode was made by using Ag2Se as electroactive material. Optimal working conditions and interferences were investigated. The electrode exhibits good potentiometric response for Se2− ions over the concentration range from 6 × 10−7 mol · L−1 to 1 × 10−4 mol · L−1 with a Nernstian slope of 28 ± 1 mV per decade and a detection limit of about 4.5 × 10−7 mol · L−1. It was used over six months and exhibits good selectivity and sensitivity towards Se2−. The method was applied to determine selenium in biological materials. The recovery ranges between 92% and 105.5%, and the relative standard derivation is less than 3.6% (n = 6).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号