首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 750 毫秒
1.
Quantitation of thin-layer chromatography (TLC) using image analysis is attractive for its low cost and convenience. The image analysis is investigated by designing a digital imaging system with simple equipment, developing an image analysis software based on our algorithm, and validated the system in the TLC quantitative assay of cichoric acid present in Echinacea purpurea (L.) Moench. TLC used a polyamide thin-layer plate with chloroform-methanol formic acid-water (3:6:1:1) as the mobile phase and 3% (m/v) aqueous aluminum chloride solution as the visualization reagent. Images are acquired with a standard digital camera under a UV viewing lamp (365 nm) in a dark room. The three-dimensional gray scale digital image dataset (x, y, gray) is reduced to two-dimensional dataset (distance, accumulative gray) and then plotted as a curve. The area under the peak corresponding to the cichoric acid spot is integrated and used for quantitation. The whole method was validated by the assay tests of detection limit, calibration curve, repeatability, reproducibility, and recovery. The results showed that our digital imaging method and image analysis algorithm were applicable for the quantification of TLC. The whole method is convenient, efficient, and moderately accurate for the quantitative assay of cichoric acid present in Echinacea purpurea (L.) Moench.  相似文献   

2.
A micellar electrokinetic chromatographic (MEKC) method was developed for the separation of ten phenolic acids including cichoric acid and caftaric acids, specific marker phytochemicals of Echinacea purpurea. The MEKC method involved the use of 70 mM sodium deoxycholate (SDC) in 40 mM borate (pH 9.2) buffer and UV detection at 300 nm. The bile acid was used as biosurfactant able to provided a micellar system with different and more selective properties than sodium dodecyl sulfate. The effects of SDC and borate concentration and buffer pH on the analyte resolution were evaluated. The validated method was applied to the determination of cichoric acid and related compounds in E. purpurea root extracts, and in commercial E. purpurea based dried extracts and tablets.  相似文献   

3.
Analytical methodologies with ultrasonic extraction and liquid chromatography (LC) were developed for the determination of phenolic compounds in dietary supplements containing Echinacea. The phenolic compounds determined by these methods included caftaric acid, chlorogenic acid, cynarin, echinacoside, and cichoric acid. Samples from tablets, capsules, and bags of tea blends were extracted by sonication for < or = 30 min with methanol-water (60 + 40). The extracts were centrifuged and filtered, and the filtrates were diluted and analyzed by LC using a reversed-phase column and coulometric electrochemical (EC) detection. The mobile phase was acetonitrile-ammonium formate buffer, pH 3.5 (15.3 + 84.7) containing tetrabutyl ammonium hydrogen sulfate as an ion-pairing reagent. Extraction conditions (e.g., composition of the extraction solvent and sonication time) were optimized for different types of samples. Intra- and interday analytical variations were determined, and intraday analyses were performed by 2 independent analysts using 2 different LC systems. Results were generally comparable. The LC method with EC detection showed better sensitivity and selectivity when compared with LC with ultraviolet detection, although results were similar for the 2 methods for major compounds, i.e., caftaric acid, echinacoside, and cichoric acid. The identities of these major compounds found in samples were confirmed by LC/electrospray ionization mass spectrometry.  相似文献   

4.
The dietary sources of CoQ10 and the evaluation of CoQ10 in dairy products were characterized. For quantitation of CoQ10 in food samples, 2 liquid chromatography (LC) methods with UV and mass spectrometry (MS) detections were developed. LC with UV detection was performed at 25 degrees C on a Hyperclone ODS 5 microm 150 x 4.6 mm column with mobile phase consisting of methanol-ethanol-2-propanol (70 + 15 + 15, v/v/v). Flow rate was 1.0 mL/min. Retention time of CoQ10 was 10.9 +/- 0.1 min. The method was sensitive [limit of detection (LOD) = 0.2 mg/kg], reproducible [relative standard deviation (RSD) = 3:0%), and linear up to 25 mg/kg (R > 0.999). LC/MS analysis was performed on a LUNA C18 3 microm, 150 x 4.6 mm column, using mobile phase consisting of ethanol-dioxane-acetic acid (9 + 1 + 0.01, v/v/v), flow rate was 0.6 mL/min, and the retention time of CoQ10 was 4.1 +/- 0.1 min. Identification and quantitation were performed with a Finnigan-LCQ mass detector in positive atmospheric pressure chemical ionization mode. Mass spectra were obtained in selected-ion monitoring mode; molecular mass (M+H)+ m/z 863.4 +/- 1 was used for quantitative determination. MS detection is more sensitive than UV detection (LOD = 0.1 mg/kg), less reproducible (RSD = 4.0%), and linear in selected range. Analytical recoveries are 75-90% and depend on the ratio between the amount of fat in the matrix and the concentration of CoQ10 in the sample. Some soybean milk products were analyzed together with different cow, goat, and sheep milk products. Concentrations obtained with LC and LC/MS were compared with a few accessible results available from the literature. Concentrations varied from 0 ppm in soybean milk to nearly 2 ppm in fresh milk from local farms.  相似文献   

5.
The development of a simple and sensitive assay for the quantitative analysis of the marine anticancer agent Yondelis (ET-743, trabectedin) in human plasma using liquid chromatography (LC) with column switching and tandem mass spectrometric (MS/MS) detection is described. After protein precipitation with methanol, diluted extracts were injected on to a small LC column (10 x 3.0 mm i.d.) for on-line concentration and further clean-up of the sample. Next, the analyte and deuterated internal standard were back-flushed on to an analytical column for separation and subsequent detection in an API 2000 triple-quadrupole mass spectrometer. The lower limit of quantitation was 0.05 ng mL(-1) using 100 micro l of plasma with a linear dynamic range up to 2.5 ng ml(-1). Validation of the method was performed according to the most recent FDA guidelines for bioanalytical method validation. The time needed for off-line sample preparation has been reduced 10-fold compared with an existing LC/MS/MS method for ET-743 in human plasma, employing a labor-intensive solid-phase extraction procedure for sample pretreatment. The proposed column switching method was successfully applied in phase II clinical trials with Yondelis and pharmacokinetic monitoring.  相似文献   

6.
Three long and 1 short reversed-phase C18 columns were compared for separation of deoxynivalenol (DON) in extracts of naturally contaminated wheat samples using liquid chromatography with ultraviolet detection and liquid chromatography/mass spectrometry (LC/MS). Among the 3 long columns used, a Symmetry C18 column with an isocratic solvent mixture of water-acetonitrile-methanol (90 + 5 + 5, v/v/v) gave the best separation for DON without interferences from other compounds in the wheat extracts. The Symmetry short (75 mm) column was comparable with the long column (250 mm) in resolving DON but significantly reduced retention time (i.e., 5.8 versus 16.3 min). Increasing the column temperature from 25 to 45 degrees C resulted in a further reduction in retention time. Identity of DON in the wheat extracts and standard solutions was confirmed by LC/MS in the positive ion mode, whereby DON appeared with an (M+1)+ ion at a mass-to-charge ratio of 297 plus fragment ions associated with loss of water and/or a 30 atomic mass unit (amu) CH2O fragment. The Symmetry short column was also capable of separating a mixture of the mycotoxins DON, 15-acetyl-DON, nivalenol, and zearalenone by use of a combination of an isocratic and gradient solvent system. The overall method showed high precision, exhibiting a relative standard deviation of 4.8%, limit of detection of 50 ng/g, and limit of quantitation of 165 ng/g. It was significantly correlated with enzyme-linked immunosorbent assay analysis, indicating its appropriateness for safety and quality assurance of wheat and related grains.  相似文献   

7.
Brazilin is a major homoisoflavonoid component isolated from the dried heartwood of traditional Chinese medicine Caesalpinia sappan L., which is a natural red pigment used for histological staining. Herein a sensitive, specific and rapid analytical LC‐MS/MS method was established and validated for brazilin in rat plasma. After a simple step of protein precipitation using acetonitrile, plasma samples were analyzed using an LC‐MS/MS system. Brazilin and the IS (protosappanin B) were separated on a Diamonsil C18 analytical column (150 × 4.6 mm, 5 µm) using a mixture of water and 10 mm ammonium acetate in methanol (20:80, v/v) as mobile phase at a flow rate of 0.6 mL/min. The method was sensitive with a lower limit of quantitation of 10.0 ng/mL, with good linearity (r2 ≥ 0.99) over the linear range 10.0–5000 ng/mL. All the validation data, such as accuracy and precision, matrix effect, extraction recovery and stability tests were within the required limits. The assay method was successfully applied to evaluate the pharmacokinetics parameters of brazilin after an oral dose of 100 mg/kg brazilin in rats. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

8.
A rapid and sensitive assay based on ultra‐high performance liquid chromatography with electrospray ionization tandem mass spectrometry was established and validated for the simultaneous determination of cichoric acid, chlorogenic acid, quinic acid, and caffeic acid in rat plasma after oral administration of Echinacea purpurea extract using butylparaben as the internal standard. Samples were pretreated by liquid–liquid extraction with ethyl acetate. The separations for analytes were performed on an ACQUITY UPLC HSS C18 column (1.8 μm 2.1 × 100 mm) using a gradient elution program with acetonitrile/10 mM ammonium acetate (pH 5.6) at a flow rate of 0.3 mL/min. The analytes were detected in multiple reaction monitoring mode with negative electrospray ionization. The lower limit of quantification of each analyte was not higher than 10.85 ng/mL. The relative standard deviation of the intraday and interday precisions was less than 14.69%. The relative errors of accuracies were in the range of –13.80 to 14.91%. The mean recoveries for extraction recovery and matrix effect were higher than 80.79 and 89.98%, respectively. The method validation results demonstrated that the proposed method was sensitive, specific, and reliable, which was successfully applied to the pharmacokinetic study of four components after oral administration of Echinacea purpurea extract.  相似文献   

9.
This paper describes a sensitive and selective liquid chromatography with tandem mass spectrometry (LC-MS/MS) method for determination of the novel survivin suppressant YM155, 1-(2-methoxyethyl)-2-methyl-4,9-dioxo-3-(pyrazin-2-ylmethyl)-4,9-dihydro-1H-naphtho[2,3-d]imidazolium, which is developed for the treatment of solid tumors. This method uses a liquid-liquid extraction from 0.25 mL of dog plasma. LC separation was carried out on a Genesis Silica column (50 mm x 3.0 mm i.d.) at a flow-rate of 0.5 mL/min. Compounds were eluted using a mobile phase of 5 mm ammonium acetate and 0.1% formic acid in water-0.1% formic acid in acetonitrile, 17:83 (v/v). MS/MS detection was carried out with an MDS-Sciex API3000 triple quadrupole mass spectrometer in positive electrospray ionization mode. The standard curve was linear from 0.05 to 50 ng/mL (r > or = 0.9968). The lower limit of quantitation was 0.05 ng/mL. Good intra- and inter-day assay precision (within 7.4% RSD) and accuracy (within +/-12.3%) were obtained. The extraction recovery was 66.2%. The method was successfully applied to preclinical pharmacokinetic studies in dogs.  相似文献   

10.
Kahalalide F (KF) is a novel cyclic depsipeptide anticancer drug, which has shown anticancer activity both in vitro and in vivo especially against human prostate cancer cell lines. To characterize the pharmacokinetics of KF during a phase I clinical trial in patients with androgen refractory prostate cancer, a method was developed and validated for the quantitative analysis of KF in human plasma using high-performance liquid chromatography (HPLC) coupled to positive electrospray ionization tandem mass spectrometry (ESI-MS/MS). Microbore reversed-phase liquid chromatography (LC) performed with mobile phases containing trifluoroacetic acid, an additive commonly used for separating peptides, resulted in substantial suppression of the signal for KF on ESI-MS/MS. An alternative approach employing a basic mobile phase provided an excellent response for KF when detected in the positive ion mode. Plasma samples were prepared for LC MS/MS by solid-phase extraction on C(18) cartridges. The LC separation was performed on a Zorbax Extend C(18) column (150 x 2.1 mm i.d., particle size 5 micro m) with acetonitrile -10 mM aqueous ammonia (85 : 15, v/v) as the mobile phase, at a flow-rate of 0.20 ml min(-1). A butyric acid analogue of KF was used as the internal standard. The lower limit of quantitation (LLQ) using a 500 micro l sample volume was 1 ng ml(-1) and the linear dynamic range extended to 1000 ng ml(-1). The inter-assay accuracy of the assay was -15.1% at the LLQ and between -2.68 and -9.05% for quality control solutions ranging in concentration from 2.24 to 715 ng ml(-1). The inter-assay precision was 9.91% or better at these concentrations. The analyte was stable in plasma under all relevant conditions evaluated and for a period of 16 h after reconstituting plasma extracts for LC analysis at ambient temperature.  相似文献   

11.
A liquid chromatographic-mass spectrometry (LC/MS) assay method was developed for the determination of amiodarone and desethylamiodarone in rat specimens. Analytes were extracted using liquid-liquid extraction in hexane. The LC/MS system consisted of a Waters Micromass ZQtrade mark 4000 spectrometer with an autosampler and pump. A C(18) 3.5 microm (2.1 x 50 mm) column heated to 45 degrees C was used for separation. The mobile phase consisted of methanol and 0.2% aqueous formic acid pumped at 0.2 mL/min as a linear gradient. Components eluted within 12 min. The concentrations of ethopropazine (internal standard), desethylamiodarone and amiodarone were monitored for m/z of 313.10, combination of 546.9 and 617.73, and 645.83, respectively. In plasma (0.1 mL), linearity was achieved between the peak area ratios and concentrations over the range of 2.5-1000 ng/mL for both amiodarone and desethylamiodarone (r(2) > 0.999). The intraday and interday CV were equal or less than 18%, and mean error was <12%. Similarly, in homogenates containing 0.1 g of rat tissue, linearity was observed in standards ranging from 5 to 5000 ng/g. The method was successfully used to measure tissue and plasma concentrations of drug. The validated lower limit of quantitation was 2.5 ng/mL for drug and metabolite, based on 0.1 mL of plasma.  相似文献   

12.
A highly hydrophilic poly(7-oxonorbornene-5,6-dicarboxylic acid-block-norbornene) [=poly-(ONDCA-b-NBE)]-coated silica was investigated for the liquid chromatographic (LC) determination of flavonoids in plant extracts of complex biological origin using UV absorbance and mass spectrometric (MS) detection. Compared to the most commonly used octadecyl derivatized silica this sorbent allowed fast separations even at extreme pH values. Furthermore, UV absorbance and MS detection were evaluated. As we found, UV detection at 254 nm allows the determination of flavonoids down to the ng range with a linearity of R2>0.9906. For the more selective characterization the validated LC system was coupled to a quadrupole ion trap mass spectrometer via an electrospray ionization (ESI) interface. MS detection showed high linearity (R2>0.9904) for all investigated flavonoids. Due to the relatively high flow-rate of 1 ml/min the limits of detection were found in the lower-microg range. Collision induced dissociation was applied to obtain characteristic fragmentation fingerprints. Finally, the validated LC-ESI-MS-MS method demonstrated that this poly-(ONDCA-b-NBE) stationary phase allows fast characterization and quantitation in onion, elderflower blossom, lime blossom, St. John's Wort and red wine.  相似文献   

13.
A sensitive LC/MS/MS assay for determining zidovudine (ZDV) and lamivudine (3TC) in human plasma was validated to support antiretroviral pharmacology research programs. After addition of stable labeled isotopic zidovudine (ZDV‐IS) and lamivudine (3TC‐IS) as internal standard, a solid‐phase extraction was performed with an Oasis HLB 1 cm3 cartridge, with recoveries of 92.3% for ZDV and 93.9% for 3TC. A Phenomonex Synergi Hydro‐RP (2.0 × 150 mm) reversed‐phase analytical column was utilized for chromatographic separation. The mobile phase consisted of an aqueous solution of 15% acetonitrile and 0.1% acetic acid. Detection was accomplished by ESI/MS/MS in the positive ion mode, monitoring 268/127, 271/130, 230/112 and 233/115 transitions, for ZDV, ZDV‐IS, 3TC and 3TC‐IS, respectively. The method was linear from 1 to 3000 ng/mL with a minimum quantifiable limit of 1 ng/mL when 100 μL of plasma was analyzed. Validation results demonstrated high accuracy (≤8.3% deviation) and high precision (≤10% CV) for the quality control samples. The method was also shown to be specific and reproducible. The value of the high sensitivity was demonstrated by quantitation of approximately 100 existing samples that had ZDV below the limit of quantitation using a previously validated, less sensitive HPLC‐UV method utilized in the laboratory. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

14.
This paper reports a rapid and sensitive method for determination of the anti-inflammatory compound vicenin-2 in L. ericoides Mart. using liquid chromatography-tandem mass spectrometry. Separation of the compound of interest was performed on a VP-ODS(18) (150 x 2 mm, Shimadzu, Japan) column and a pre-column packed with GPV-ODS C(18) (5 x 2 mm, Sigma-Aldrich, USA) with acetonitrile-water (15:85) mobile phase containing 2% acetic acid using isocratic flow at 0.5 mL/min for 2 min. Multiple-reaction monitoring of vicenin-2 was performed using electrospray positive ionization. The linear calibration curves were generated using a concentration range of 5-2500 ng/mL with correlation coefficients >0.99. The values of limit of detection and limit of quantitation were found to be 1 and 5 ng/mL, respectively. The method developed based on LC-ESIMS/MS is advantageous because it permits the rapid and selective detection of vicenin-2. Furthermore, the method can be easily applied to the routine analysis of vicenin-2 in plant extracts using a minimal amount of sample.  相似文献   

15.
A rapid and sensitive method for the simultaneous confirmatory analysis of three forensic most relevant cannabinoids, Delta(9)-tetrahydrocannabinol (THC), 11-hydroxy-Delta(9)-tetrahydrocannabinol (11-OH-THC) and 11-nor-9-carboxy-Delta(9)-tetrahydrocannabinol (THC-COOH), by means of high-performance liquid chromatography/tandem mass spectrometry (LC/MS/MS) in human plasma was developed and fully validated. Sample clean-up was performed by automated silica-based solid-phase extraction and the separation was carried out using a PhenylHexyl column (50 x 2 mm i.d., 3 micro m) and acetonitrile-5 mM ammonium acetate gradient elution. Data were acquired with an API 3000 LC/MS/MS system equipped with a turboionspray interface and triple quadrupole mass analyzer using positive electrospray ionization and multiple reaction monitoring. Two MS/MS transitions for each substance were monitored and deuterated analogues of analytes were used as internal standards for quantitation. The limit of quantitation was 0.8 ng ml(-1) for THC, 0.8 ng ml(-1) for 11-OH-THC and 4.3 ng ml(-1) for THC-COOH and linearity with a correlation coefficient r(2) = 0.999 was achieved up to 100 ng ml(-1) for THC and 11-OH-THC and 500 ng ml(-1) for THC-COOH. The limits of detection were 0.2 ng ml(-1) for THC, 0.2 ng ml(-1) for 11-OH-THC and 1.6 ng ml(-1) for THC-COOH. The developed LC/MS/MS method was also successfully used for the determination of THC-COOH-glucuronide, the phase II metabolite of THC-COOH.  相似文献   

16.
A rapid and sensitive method for the quantitation of buspirone in human plasma by liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) was developed. Plasma samples were treated by liquid-liquid extraction with methyl tert-butyl ether (MTBE). The chromatographic separation was performed isocratically on a reversed-phase Shiseido C18 column (50 mm x 2.0 mm, 3 microm) with a mobile phase of acetonitrile/0.1% acetic acid (1:1, v/v). The acquisition was performed in multiple reaction monitoring (MRM) mode, monitoring the transitions m/z 386 --> 122 for buspirone and m/z 409 --> 238 for amlodipine (the internal standard). The method was validated to determine its specificity, recovery, limit of quantitation, accuracy and precision. The lower limit of quantitation was 0.02 ng/mL with a relative standard deviation of less than 10%. The present method provides an accurate, precise and sensitive tool for buspirone and was successfully applied to a pharmacokinetic study in eight subjects.  相似文献   

17.
A simple, rapid and high sensitive liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method for the determination of neostigmine in small‐volume beagle dog plasma was developed to assess the plasma pharmacokinetics of neostigmine. After protein precipitation in a Sirocco 96‐well filtration plate, the filtrate was directly injected into the LC‐MS/MS system. The analytes were separated on a Hanbon Hedera CN column (100 × 4.6 mm, 5 µm) with a mobile phase composed of methanol–water (60:40, v/v) and the water containing 0.01% formic acid at a flow rate of 0.6mL/min, with a split ratio of 1:1 flowing 300 μL into the mass spectrometer. The run time was 3 min. Detection was accomplished by electrospray ionization source in multiple reactions monitoring mode with the precursor‐to‐product ion transitions m/z 223.0 → 72.0 and 306.0 → 140.0 for neostigmine and anisodamine (internal standard), respectively. The method was sensitive with a lower limit of quantitation of 0.1 ng/mL, and good linearity in the range 0.1–100ng/mL for neostigmine (r ≥ 0.998). All the validation data, such as accuracy, intra‐run and inter‐run precision, were within the required limits. The method was successfully applied to pharmacokinetic study of neostigmine methylsulfate injection in beagle dogs. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

18.
A simple and inexpensive liquid chromatography/mass spectrometry (LC/MS) method was developed for the quantitation of acrylamide in various food products. The method involved spiking the isotope-substituted internal standard (1-C13 acrylamide) onto 6.00 g of the food product, adding 40 mL distilled/deionized water, and heating at 65 degrees C for 30 min. Afterwards, 10 mL ethylene dichloride was added and the mixture was homogenized for 30 s and centrifuged at 2700 x g for 30 min, and then 8 g supernatant was extracted with 10, 5, and 5 mL portions of ethyl acetate. The extracts were combined, dried with sodium sulfate, and concentrated to 100-200 microL. Acrylamide was determined by analysis of the final extract on a single quadrupole, bench-top mass spectrometer with electrospray ionization, using a 2 mm id C18 column and monitoring m/z = 72 (acrylamide) and m/z = 73 (internal standard). For difficult food matrixes, such as coffee and cocoa, a solid-phase extraction cleanup step was incorporated to improve both chromatography and column lifetime. The method had a limit of quantitation of 10 ppb, and coefficients of determination (r2) for calibration curves were typically better than 0.998. Acceptable spike recovery results were achieved in 11 different food matrixes. Precision in potato chip analyses was 5-8% (relative standard deviation). This method provides an LC/MS alternative to the current LC/MS/MS methods and derivatization gas chromatography/mass spectrometry methods, and is applicable to difficult food products such as coffee, cocoa, and high-salt foods.  相似文献   

19.
A rapid analytical method based on liquid chromatography/tandem mass spectrometry (LC/MS/MS) using electrospray ionization in negative ion detection mode was developed for the analysis of underivatized iodoacetic acid in water. The method was applied to model reaction mixtures in the study of the formation of iodoacetic acid after chlorinated tap water was boiled in the presence of potassium iodide or iodized table salt. Samples can be directly analyzed by the LC/MS/MS system without extraction or chemical derivatization. Limit of detection was determined to be 0.3 microg/L (or 0.3 ng/mL) and limit of quantitation was about 1 microg/L (1 ng/mL).  相似文献   

20.
A highly sensitive, specific and fully validated LC‐MS/MS method as per general practices of industry has been developed for estimation of lamotrigine (LAM) with 100 μL of human plasma using flucanozole as an internal standard (IS). The API‐4000 LC‐MS/MS was operated under the multiple reaction‐monitoring mode using electrospray ionization. A simple liquid–liquid extraction process was used to extract LAM and IS from human plasma. The total run time was 2.0 min and the elution of LAM and IS occurred at 1.25 and 1.45 min; this was achieved with a mobile phase consisting of 0.1% formic acid–methanol (20:40:40, v/v) at a flow rate of 0.50 mL/min on a Discovery CN (50 × 4.6 mm, 5 µm) column. The developed method was validated in human plasma with a lower limit of quantitation of 0.1 ng/mL for LAM. A linear response function was established for the range of concentrations 0.1–1500 ng/mL (r > 0.998) for LAM. The intra‐ and inter‐day precision values for LAM met the acceptance as per Food and Drug Administration guidelines. LAM was stable in the set of stability studies, viz. bench‐top, autosampler and freeze–thaw cycles. The developed assay method was applied to an oral bioequivalence study in humans. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号