首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A spectrophotometric method for simultaneous determination of Fe(III), Al(III) and Cu(II) using Alizarin Red S as a chelating agent was developed. The parameters controlling behavior of the system were investigated and optimum conditions were selected. A partial least-squares multivariate calibration method was used for the analysis of ternary mixtures of Fe(III), Al(III) and Cu(II) over the range of 450-6000, 140-4000 and 450-15000 ng ml(-1), respectively. Absorbance data were taken between 400 and 800 nm. Applying this method to simultaneous determination of these metal ions in several synthetic alloy solutions with total relative standard error of less than 5% validated the proposed method.  相似文献   

2.
Chang X  Su Q  Liang D  Wei X  Wang B 《Talanta》2002,57(2):253-261
Poly(acryldinitrophenylamidrazone-dinitroacrylphenylhydrazine) chelating fiber was synthesized from polyacrylonitrile fiber and used for enrichment and separation for traces of Au(III), Ru(III), In(III), Bi(III), Zr(IV), V(V), Ga(III) and Ti(IV) ions from solution samples. The acidity, rate, re-use, capacity and interference on the adsorption of ions on the chelating fiber as well as the conditions of desorption of these ions from the chelating fiber were investigated by means of inductively coupled plasma optical emission spectrometry. The results show that 10-100 ngml(-1) of Au(III), Ru(III), In(III), Bi(III), Zr(IV), V(V), Ga(III) and Ti(IV) ions can be quantitatively enriched by the chelating fiber at a 2 mlmin(-1) of flow rate in the range pH 4-5, and desorbed quantitatively with 20 ml of 5 M HCl for In(III), Bi(III), Zr(IV), V(V), Ga(III), Ti(IV) and 20 ml of 4 M HCl+2% CS(NH(2))(2) solution for Au(III), Ru(III) (with recovery>95%). 50- to 500- fold excesses of Fe(III), Al(III), Mg(II), Mn(II), Ca(II), Cu(II), Ni(II) ions cause little interference in the concentration and determination of analyzed ions. When the fiber was reused for 8 times, the recoveries of the above ions enriched by the fiber were still over 87%. The relative standard deviations (RSDs) for the enrichment and determination of 10 ngml(-1) Au, Ru, In, Bi, Ga and 1 ngml(-1) Zr, V, Ti were lower than 3.0%. The results obtained for these ions in real solution samples by this method were basically in agreement with the given values with average errors of less than 6.3%. FT-IR spectra show that existence of NNCNHNH, OCNHNH and NO(2) functional groups are verified in chelating fiber, and Au(III) or Ru(III) is mainly combined with nitrogen (or oxygen) of the groups to form a chelate complex.  相似文献   

3.
Abbaspour A  Mirzajani R 《Talanta》2004,64(2):435-441
Simultaneous determination of V(V) and Al(III) was performed by application of neural networks when the calibration matrix was performed using β-correction spectra. Two reactions between V(V) and Al(III) and Alizarin Red S (ARS) as a ligand have been investigated and applied for the simultaneous spectrophotometric determination of these metal ions. The parameters controlling behavior of the system were investigated and optimum conditions selected. Feed-forward neural networks have been trained to quantify considered metal ions in mixtures under optimum conditions. Sigmoidal functions were used in the hidden and output layers. Determinations were made over the concentration range 0.10-7.80 μg ml−1 of V(V) and 0.11-4.20 μg ml−1 of Al(III). Applying this method satisfactorily to simultaneous determination of these metal ions in several synthetic solutions with total relative standard error less than 4.02% validated the proposed method.  相似文献   

4.
Microcrystalline naphthalene extraction has been used for the preconcentration of p-benzoquinone and tetrachloro-p-benzoquinone (chloranil), after their reaction by aniline, and later simultaneous spectrophotometric analysis by genetic algorithm-partial least squares (GA-PLS) calibration. The chemical variables affecting the analytical performance of the methodology were studied and optimized. Under the optimum conditions i.e., [aniline] = 0.05 M and [naphthalene] = 2.2% (w/v), preconcentration of 25 ml of sample solution permitted the detection of 0.32 and 0.23 microg ml(-1) for p-benzoquinone and chloranil, respectively. The predictive abilities of partial least squares regression (PLS) and genetic algorithm-partial least squares regression (GA-PLS) were examined for simultaneous determination of two quinones. The GA-PLS shows superiority over other PLS methods due to the wavelength selection in PLS calibration using a genetic algorithm without loss of prediction capacity, provides useful information about the chemical system.  相似文献   

5.
A spectrophotometric method for simultaneous determination of Al(III) and Fe(III) using the chelator Desferal® (desferrioxamine B) was developed. Partial least squares (PLS) regression was performed to resolve the overlapped signals obtained from Al(III) and Fe(III) complexes. The parameters controlling behavior of the system were investigated and optimum conditions were selected. PLS was the choice for the analysis of binary mixtures of Fe(III) and Al(III) over the range of 0.1 to 0.8 mg L?1 by using the data of first derivative spectra. Absorbance data were taken between 200 and 600 nm. The calculated sensitivity values for the multivariate method were 4.88 and 5.64 for Al(III) and Fe(III), respectively. Multivariate detection limits were 0.075 and 0.064 mg L?1 for Al(III) and Fe(III), respectively. The method was applied to real post-hemodialysis samples, and sample digestion by UV irradiation was discussed.  相似文献   

6.
Simultaneous determination of Fe(II) and Fe(III) was studied using partial least squares regression (PLS) and principal component regression (PCR) methods. The models were based on the difference observed in the rates of the complex formation of iron in its two oxidation states with 1,2-naphthaquinone-2-thiosemicarbazone-4-sulphonic acid (NQT4S) at pH 4.0 in cetyltrimethylammoniumbromide (CTAB) as micellar media. The results showed that simultaneous determination of Fe(II) and Fe(III) could be performed in their concentration ranges of 0.10-2.10 and 0.25-2.25 μg/ml, respectively. The models used can proceed the data with low percent relative error of prediction (i.e. <5.5%). The procedure was successfully applied for the simultaneous determination of Fe(II) and Fe(III) in some environmental samples. The method would allow the transformation of the two oxidation states of iron to be monitored overtime in a water sample.  相似文献   

7.
In this work, a new method has been proposed to simultaneously determine V(V), Co(II) and Cu(II) ions from aqueous solution by spectrophotometry after cloud point extraction using partial least squares regression (PLS). The metal ions in 10 ml of aqueous solution (containing 0.2 M sodium acetate buffer solution, pH 3.5) were formed complexes with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP). Then, Triton X-114 (2 %, v/v) was added to the solution. By increasing the temperature of the solution up to 55 °C, a phase separation occurred. After centrifugation at 3,000 rpm for 10 min, the surfactant-rich phase was dissolved and diluted to 0.5 mL with ethanol. The metal ions were then determined using spectrophotometry. At these optimal extraction and operating conditions, linearity was obeyed in the range 7–300, 3–100 and 15–700 ng mL?1 of V(V), Co(II) and Cu(II), with the detection limit of 2.2, 1.0 and 4.5 ng mL?1, respectively. The relative predictive error for the simultaneous determination of 15 test samples of different concentrations of V(V), Co(II) and Cu(II) was 3.28, 3.64 and 4.04 %, respectively. The root mean square error of prediction for applying the PLS method to 15 synthetic samples in the linear ranges of these metal ions was 3.4, 1.6 and 18.1 ng mL?1. The interference effect of some anions and cations was also tested. The proposed method has been applied successfully to the simultaneous determination of V(V), Co(II) and Cu(II) ions in real matrix samples with the recoveries of 96.75–104.80 %.  相似文献   

8.
A new methodology is presented for the simultaneous determination of chromium(VI) and aluminum(III) by differential‐pulse adsorptive stripping voltammetry (DPAdSV) with Pyrocatechol Violet (PCV) as a complexing agent. In this procedure, a partial least‐squares regression (PLS) is used for the resolution of the strongly overlapping voltammetric signals from mixtures of CrVI and AlIII in the presence of PCV. The procedure was successfully applied to the determination of these metals in river water.  相似文献   

9.
This paper describes a procedure for the speciation of antimony by UV-vis spectroscopy using pyrogallol as complexing agent. A partial least squares (PLS) regression was performed to resolve highly overlapping spectrophotometric signals obtained from mixtures of Sb(III) and Sb(V). The relative error in absolute value was less than 5% when concentrations of several mixtures were calculated. The minimum concentration determined was 3.96 × 10−5 mol dm−3 and 3.98 × 10−5 mol dm−3 for Sb(V) and Sb(III), respectively. The analysis of the possible effect of the presence of foreign ions in the solution was performed and the procedure was successfully applied to the speciation of antimony in pharmaceutical preparations and aqueous samples.  相似文献   

10.
Simultaneous determination of V(IV) and V(V) was performed by application of partial least squares when the calibration matrix was obtained using beta-correction spectra. Two reaction between V(IV) and V(V) and Pyrogallol Red as a ligand in presence of cethyltrimethylammoniumbromide (CTAB) media has been investigated and applied to the simultaneous spectrophotometric determination of these species. The parameters controlling behavior of the system were investigated and optimum conditions selected. Determinations were made over the concentration range 0.6-4.50 microg ml-1 of V(IV) and 0.3-5.50 microg ml-1 of V(V). Applying this method to simultaneous determination of these metal ions in several real samples with total relative standard error less than 5% validated the proposed method.  相似文献   

11.
Abbaspour A  Najafi M 《Talanta》2003,60(5):1079-1084
A method for simultaneous spectrophotometric determination of Sb(III) and Sb(V) using multivariate calibration method is proposed. This method is based on the development of the reaction between the analytes and pyrogallol red at pH 2.00. The selection of variables was studied. A series of synthetic solutions containing different concentrations of Sb(III) and Sb(V) were used to check the prediction ability of the partial least squares model. The calibration curves were linear over the range of 0.3-3.4 and 0.3-3.0 μg ml−1 for Sb(III) and Sb(V), respectively. The detection limits were 0.177 and 0.200 μg ml−1 for Sb(III) and Sb(V), respectively.  相似文献   

12.
《Analytical letters》2012,45(6):1209-1226
Abstract

A sensitive method for the simultaneous spectrophotometric determination of Fe(II), Cu(II), Zn(II), and Mn(II) in mixtures has been developed with the aid of multivariate calibration methods, such as classical least squares (CLS), principal component regression (PCR) and partial least squares (PLS). The method is based on the spectral differences of the analytes in their complexation reaction with 4‐(2‐pyridylazo)‐resorcinol (PAR) and the use of full spectra with wavelengths in the range of 300–600 nm. It was found that both the spectral positive and negative bands obtained against the PAR blank, are proportional to the concentration for each metal complex. The obtained linear calibration concentration ranges are 0.025–0.6, 0.05–0.8, 0.025–0.8, and 0.05–0.8 µg ml?1 for Fe(II), Cu(II), Zn(II), and Mn(II), respectively, and the LODs for the four metal ions were found to be approximately 1–3×10?2 µg ml?1. The proposed method was applied to a verification set of synthetic mixtures of these four metal ions, with models built in three different wavelength ranges, i.e., 300–450, 450–600, and 300–600 nm, corresponding to the positive, negative bands and their combinations, respectively. It was shown that the PLS model for the 300–600 nm range gave the best results (RPET=6.9% and average recovery ~100%; cf. PCR: RPET=9.5% and average Recovery ~110%). This method was also successfully applied for the determination of the four metal ions in pharmaceutical preparations, chicken feedstuff, and water samples.  相似文献   

13.
The simultaneous determination of manganese(II) and iron(II) mixtures by using spectrophotometric methods is a difficult problem in analytical chemistry, due to spectral interferences. By multivariate calibration methods, such as partial least squares (PLS), it is possible to obtain a model adjusted to the concentration values of the mixtures used in the calibration range. Orthogonal signal correction (OSC) is a preprocessing technique used to remove the information unrelated to the target variables based on constrained principal component analysis. OSC is a suitable preprocessing method for partial least squares calibration of mixtures without loss of prediction capacity using spectrophotometric method. In this study, the calibration model is based on absorption spectra in the 450-600 nm range for 21 different mixtures of manganese(II) and iron(II). Calibration matrices were containing 0.05-1.2 and 0.1-2.3 microg mL(-1) Mn(II) and Fe(II), respectively. The RMSEP for manganese(II) and iron(II) with OSC and without OSC were 0.0316, 0.0291, and 0.0907, 0.115, respectively. This procedure allows the simultaneous determination of manganese(II) and iron(II) in synthetic and real matrix samples with good reliability of the determination.  相似文献   

14.
Ghasemi J  Niazi A  Leardi R 《Talanta》2003,59(2):311-317
Genetic algorithm (GA) is a suitable method for selecting wavelengths for PLS (partial least squares) calibration of mixtures with almost identical spectra without loss of prediction capacity using spectrophotometric method. The method is based on the development of the reaction between the analytes and Zincon at pH 9. A series of synthetic solution containing different concentrations of copper and zinc were used to check the prediction ability of the GA-PLS models. The RMSD for copper and zinc with GA and without GA were 0.0407 and 0.0865, 0.2147 and 0.3005, respectively. Calibration matrices were 0.05-1.8 and 0.05-1.5 μg ml−1 for copper and zinc, respectively. This procedure allows the simultaneous determination of cited ions in natural, tap and waste waters good reliability of the determination was proved.  相似文献   

15.
A novel, sensitive and highly selective first derivative spectrophotometric method is proposed for the determination of vanadium(V) and iron(III) metal ions separately and simultaneously in a mixture. 2-Hydroxy-1-naphthaldehyde benzoylhydrazone (OHNABH) reacts with vanadium(V) and iron(III) in sodium acetate–acetic acid buffer medium (pH 5.0) forming yellow and yellowish brown colored soluble complexes, respectively. The first derivative curves of these colored solutions show maximum derivative amplitudes at 465 nm (V(V)) and 540 nm (Fe(III)) obeying Beer's law in the range 0.12–2.50 g ml–1 and 0.14–4.20 g ml–1, respectively. Large number of foreign ions do not interfere in the present method. A very simple and accurate simultaneous first derivative method is also reported for the determination of V(V) and Fe(III) in mixtures without solving simultaneous equations. The method is applied for the analysis of various natural samples, food and biological materials.  相似文献   

16.
Metal ions such as Co(II), Ni(II), Cu(II), Fe(III) and Cr(III), which are commonly present in electroplating baths at high concentrations, were analysed simultaneously by a spectrophotometric method modified by the inclusion of the ethylenediaminetetraacetate (EDTA) solution as a chromogenic reagent. The prediction of the metal ion concentrations was facilitated by the use of an orthogonal array design to build a calibration data set consisting of absorption spectra collected in the 370-760 nm range from solution mixtures containing the five metal ions earlier. With the aid of this data set, calibration models were built based on 10 different chemometrics methods such as classical least squares (CLS), principal component regression (PCR), partial least squares (PLS), artificial neural networks (ANN) and others. These were tested with the use of a validation data set constructed from synthetic solutions of the five metal ions. The analytical performance of these chemometrics methods were characterized by relative prediction errors and recoveries (%). On the basis of these results, the computational methods were ranked according to their performances using the multi-criteria decision making procedures preference ranking organization method for enrichment evaluation (PROMETHEE) and geometrical analysis for interactive aid (GAIA). PLS and PCR models applied to the spectral data matrix that used the first derivative pre-treatment were the preferred methods. They together with ANN-radial basis function (RBF) and PLS were applied for analysis of results from some typical industrial samples analysed by the EDTA-spectrophotometric method described. DPLS, DPCR and the ANN-RBF chemometrics methods performed particularly well especially when compared with some target values provided by industry.  相似文献   

17.
A method for simultaneous analysis of V(IV) and Co(II) has been developed by using artificial neural network (ANN). This method is based on the difference of the chemical reaction rate of V(IV) and Co(II) with Fe(III) in the presence of chromogenic reagent, 1,10-phenanthroline. The reduced product of the reaction, Fe(II), can form a colored complex with 1,10-phenanthroline and make a visible spectrophotometric signal for indirect monitoring of the V(IV) and Co(II) concentrations. Feed forward neural networks have been trained to quantify considered metal ions in mixtures under optimum conditions. The networks were shown to be capable of correlating reduced spectral kinetic data using principal component analysis (PCA) of mixtures with individual metal ion. In this way an ANN containing three layers of nodes was trained. Sigmoidal and linear transfer functions were used in the hidden and output layers, respectively, to facilitate nonlinear calibration. Both V(IV) and Co(II) were analyzed in the concentration range of 0.1-4.0 μg ml−1. The proposed method was also applied satisfactorily to the determination of considered metal ions in several synthetic and water samples.  相似文献   

18.
In this paper, a flow-injection chemiluminescence (CL) system is proposed for simultaneous determination of Co(II) and Cr(III) with partial least squares calibration. This method is based on the fact that both Co(II) and Cr(III) catalyze the luminol-H(2)O(2) CL reaction, and that their catalytic activities are significantly different on the same reaction condition. The CL intensity of Co(II) and Cr(III) was measured and recorded at different pH of reaction medium, and the obtained data were processed by the chemometric approach of partial least squares. The experimental calibration set was composed with nine sample solutions using orthogonal calibration design for two component mixtures. The calibration curve was linear over the concentration range of 2 x 10(-7) to 8 x 10(-10) and 2 x 10(-6) to 4 x 10(-9) g/ml for Co(II) and Cr(III), respectively. The proposed method offers the potential advantages of high sensitivity, simplicity and rapidity for Co(II) and Cr(III) determination, and was successfully applied to the simultaneous determination of both analytes in real water sample.  相似文献   

19.
Resolution of binary mixtures of vitamin B12, methylcobalamin and B12 coenzyme with minimum sample pre-treatment and without analyte separation has been successfully achieved by methods of partial least squares algorithm with one dependent variable (PLS1), orthogonal signal correction/partial least squares (OSC/PLS), principal component regression (PCR) and hybrid linear analysis (HLA). Data of analysis were obtained from UV-vis spectra. The UV-vis spectra of the vitamin B12, methylcobalamin and B12 coenzyme were recorded in the same spectral conditions. The method of central composite design was used in the ranges of 10-80mgL(-1) for vitamin B12 and methylcobalamin and 20-130mgL(-1) for B12 coenzyme. The models refinement procedure and validation were performed by cross-validation. The minimum root mean square error of prediction (RMSEP) was 2.26mgL(-1) for vitamin B12 with PLS1, 1.33mgL(-1) for methylcobalamin with OSC/PLS and 3.24mgL(-1) for B12 coenzyme with HLA techniques. Figures of merit such as selectivity, sensitivity, analytical sensitivity and LOD were determined for three compounds. The procedure was successfully applied to simultaneous determination of three compounds in synthetic mixtures and in a pharmaceutical formulation.  相似文献   

20.
A multivariate calibration model (PLS) was developed for the simultaneous spectrophotometric determination of Al(III) and Fe(III) in post-hemodialysis fluids with pyrocathecol violet (PCV) as chromogenic reagent. The analytes build stable complexes with PCV in presence of hexamine buffered medium at pH 6.1. The complexes show overlapped absorption bands in the spectral range of 220-800 nm so that absorptions of 580 wavelengths were necessary for the calibrations. Determinations of Al(III) and Fe(III) were done without masking agents. The best calibration model was obtained by using PLS-1 regression with three components after data mean centering. The spectrophotometric method applied to assay the analytes in real post-hemodialysis samples containing no desferrioxamine B presented good agreement with voltammetric measurements used as reference. Concentrations ranging from 0.20 to 0.60 mg L−1 for Al(III) and for Fe(III) were determined in real samples. The multivariate detection limits for Al(III) and Fe(III) were 0.044 and 0.052 mg L−1, respectively, and the calculated values of sensitivity were 6.33 for Al(III) and 3.44 for Fe(III). The proposed method showed to be straightforward and useful to follow the hemodialysis progress for patients under treatment. Interferents were also investigated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号