首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple validated LC-UV method for the phytochemical analysis of four bioactive quassinoids, 13alpha(21)-epoxyeurycomanone (EP), eurycomanone (EN), 13alpha,21-dihydroeurycomanone (ED) and eurycomanol (EL) in rat plasma following oral (200 mg/kg) and intravenous administration (10 mg/kg) of a standardized extract Fr 2 of Eurycoma longifolia Jack was developed for pharmacokinetic and bioavailability studies. The extract Fr 2 contained 4.0%, 18.5%, 0.7% and 9.5% of EP, EN, ED and EL, respectively. Following intravenous administration, EP displayed a relatively longer biological half-life (t1/2 = 0.75 +/- 0.25 h) due primarily to its lower elimination rate constant (k(e)) of 0.84 +/- 0.26 h(-1)) when compared with the t1/2 of 0.35 +/- 0.04 h and k(e) of 2.14 +/- 0.27 h(-1), respectively of EN. Following oral administration, EP showed a higher C(max) of 1.61 +/- 0.41 microg/mL over that of EN (C(max) = 0.53 +/- 0.10 microg/mL). The absolute bioavailability of EP was 9.5-fold higher than that of EN, not because of chemical degradation since both quassinoids were stable at the simulated gastric pH of 1. Instead, the higher log K(ow) value of EP (-0.43) contributed to greater membrane permeability over that of EN (log K(ow) = -1.46) at pH 1. In contrast, EL, being in higher concentration in the extract than EP, was not detected in the plasma after oral administration because of substantial degradation by the gastric juices after 2 h. Similarly, ED, being unstable at the acidic pH and together with its low concentration in Fr 2, was not detectable in the rat plasma. In conclusion, upon oral administration of the bioactive standardized extract Fr 2, EP and EN may be the only quassinoids contributing to the overall antimalarial activity; this is worthy of further investigation.  相似文献   

2.
In previous studies, new electrospray ionization mass spectrometry (ESI‐MS) approaches were developed for the highly sensitive detection of singly and doubly charged anions in positive mode ESI‐MS by using specially synthesized dicationic and tricationic ion‐pairing agents, respectively. By detecting the positively charged ion complex in the positive mode, limits of detection (LODs) for the anions can be lowered by several magnitudes. In this work, we used eighteen newly synthesized tetracationic ion‐pairing agents, constructed with different geometries, linkages and cation moieties, for the detection of eighteen triply charged anions of different structural motifs. The LODs for these anions were from ten to several thousand times lower in the positive selective ion monitoring (SIM) mode than in the negative mode. These tetracationic agents also were shown to be useful for the detection of ?1 and ?2 anions. In addition, the LODs for ?3 anions can be further lowered by monitoring the product fragments of the ion‐pairing complexes in the single reaction monitoring (SRM) mode. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

3.
In contrast to common expectations, the differences in limits of detection (LODs) between electron capture negative ionization (ECNI) and electron ionization (EI) mass spectrometry (MS) were found to be insignificant for a wide range of aldehydes derivatized with o-(2,3,4,5,6-pentafluorobenzyl)-hydroxylamine hydrochloride. Comparison of the two ionization methods based on LOD confidence intervals revealed that a traditional presentation of the LOD or limit of quantitation (LOQ) as a single value may over/underestimate the significance of obtained results. LODs were between 20 and 150 pg injected for the majority of tested derivatized carbonyls using both ionization methods. ECNI-MS improved LODs by ~10- to 20-fold only for two derivatized aldehydes, 4-hydroxybenzaldehyde and 5-(hydroxymethyl)furfural. Selectivity of ECNI did not appear to be beneficial when analyzing a wood smoke particulate matter (WS-PM) extract, possibly because the majority of interferences were removed during sample preparation (i.e., liquid-liquid extraction). The impact of four different data acquisition modes of transmission quadrupole (TQ)-MS on LODs and their precisions was also investigated. As expected, LODs in the selected ion monitoring (SIM) were ~two to four times lower than those obtained using total ion current (TIC) mode. More importantly, TQ-MS in the selected ion-total ion (SITI) mode (i.e., acquiring SIM and TIC data in a single analysis) provided signal-to-noise ratios and precisions, which were comparable to SIM alone.  相似文献   

4.
Phospholipids make up one of the more important classes of biological molecules. Because of their amphipathic nature and their charge state (e.g., negatively charged or zwitterionic) detection of trace levels of these compounds can be problematic. Electrospray ionization mass spectrometry (ESI-MS) is used in this study to detect very small amounts of these analytes by using the positive ion mode and pairing them with fifteen different cationic ion pairing reagents. The phospholipids used in this analysis were phosphatidylethanolamine (PE), phosphatidylcholine (PC), phosphatidylglycerol (PG), phosphatidylserine (PS), phosphatidylinositol (PI), phosphatidic acid (PA), 1,2-diheptanoyl-sn-glycero-3-phosphocholine (DHPC), cardiolipin (CA) and sphingosyl phosphoethanolamine (SPE). The analysis of these molecules was carried out in the single ion monitoring (SIM) positive mode. In addition to their detection, a high performance liquid chromatography and mass spectrometry (HPLC-MS) method was developed in which the phospholipids were separated and detected simultaneously within a very short period of time. Separation of phospholipids was developed in the reverse phase mode and in the hydrophilic interaction liquid chromatography (HILIC) mode HPLC. Their differences and impact on the sensitivity of the analytes are compared and discussed further in the paper. With this technique, limits of detection (LODs) were very easily recorded at low ppt (ng L(-1)) levels with many of the cationic ion pairing reagents used in this study.  相似文献   

5.
The effect of nine different eluent compositions on the ionization efficiency of five flavonoids was studied using ion spray (IS), atmospheric pressure chemical ionization (APCI), and the novel atmospheric pressure photoionization (APPI), in positive and negative ion modes. The eluent composition had a great effect on the ionization efficiency, and the optimal ionization conditions were achieved in positive ion IS and APCI using 0.4% formic acid (pH 2.3) as a buffer, and in negative ion IS and APCI using ammonium acetate buffer adjusted to pH 4.0. For APPI work, the eluent of choice appeared to be a mixture of organic solvent and 5 mM aqueous ammonium acetate. The limits of detection (LODs) were determined in scan mode for the analytes by liquid chromatography/mass spectrometry using IS, APCI and APPI interfaces. The results show that negative ion IS with an eluent system consisting of acidic ammonium acetate buffer provides the best conditions for detection of flavonoids in mass spectrometry mode, their LODs being between 0.8 and 13 microM for an injection volume of 20 microl.  相似文献   

6.
This study compared the sensitivities and matrix effects of four ionization modes and four reversed-phase liquid chromatographic (LC) systems on analyzing estrone (E1), 17β-estradiol (E2), estriol (E3), 17α-ethinylestradiol (EE2), 4-nonylphenol (NP), 4-tert-octylphenol (OP), bisphenol A (BPA) and their derivatives of dansyl chloride or pentafluorobenzyl bromide (PFBBr) in water matrixes using a triple-quadrupole mass spectrometer with selected reaction monitoring (SRM). The four probes were electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI), atmospheric pressure photoionization (APPI) and APCI/APPI; the four LC systems were ultra-performance liquid chromatography (UPLC) with or without post-column split, a mixed-mode column and two-dimensional LC (2D-LC). Dansylated compounds with ESI at UPLC condition had the most intense signals and less matrix effects of the various combinations of ionization and LC systems. The on-column limits of detection (LODs) of dansylated estrogens by SRM were 0.05–0.20 pg, and the LODs in sewage treatment plant effluent and in river water were 0.23–0.52 and 0.56–0.91 ng/L, respectively. The LODs using selected ion monitoring (SIM) reached low ng/L levels in real samples and measured concentrations were comparable with those of SRM.  相似文献   

7.
Steroid sex hormones and related synthetic compounds have been shown to provoke alarming estrogenic effects in aquatic organisms, such as feminization, at very low concentrations (ng/L or pg/L). In this work, different chromatographic techniques, namely, gas chromatography/mass spectrometry (GC/MS), liquid chromatography/mass spectrometry (LC/MS) and liquid chromatography/tandem mass spectrometry (LC/MS/MS), are discussed for the analysis of estrogens, both free and conjugated, and progestogens, and the sensitivities achieved with the various techniques are inter-compared. GC/MS analyses are usually carried out after derivatization of the analytes with bis(trimethylsilyl)trifluoroacetamide (BSTFA). For LC/MS and LC/MS/MS analyses, different instruments, ionization techniques (electrospray (ESI) and atmospheric pressure chemical ionization (APCI)), ionization modes (negative ion (NI) and positive ion (PI)) and monitoring modes (selected ion monitoring (SIM) and selected reaction monitoring (SRM)) are generally employed. Based on sensitivity and selectivity, LC/ESI-MS/MS is generally the method of choice for determination of estrogens in the NI mode and of progestogens in the PI mode (instrumental detection limits (IDLs) 0.1-10 ng/mL). IDLs achieved by LC/ESI-MS in the SIM mode and by LC/ESI-MS/MS in the SRM mode were, in general, comparable, although the selectivity of the latter is significantly higher and essential to avoid false positive determinations in the analysis of real samples. Conclusions and future perspectives are outlined.  相似文献   

8.
Metals play a very important role in many scientific and environmental fields, and thus their detection and analysis is of great necessity. A simple and very sensitive method has been developed herein for the detection of metals in positive ion mode ESI‐MS. Metal ions are positively charged, and as such they can potentially be detected in positive ion mode ESI‐MS; however, their small mass‐to‐charge (m/z) ratio makes them fall in the low‐mass region of the mass spectrum, which has the largest background noise. Therefore, their detection can become extremely difficult. A better and well‐known way to detect metals by ESI‐MS is by chelating them with complexation agents. In this study eleven different metals, Fe(II), Fe(III), Mg(II), Cu(II), Ru(III), Co(II), Ca(II), Ni(II), Mn(II), Sn(II), and Ag(I), were paired with two commercially available chelating agents: ethylenediaminetetraacetic acid (EDTA) and ethylenediaminedisuccinic acid (EDDS). Since negative ion mode ESI‐MS has many disadvantages compared to positive ion mode ESI‐MS, it would be very beneficial if these negatively charged complex ions could be detected in the positive mode. Such a method is described in this paper and it is shown to achieve much lower sensitivities. Each of the negatively charged metal complexes is paired with six cationic ion‐pairing reagents. The new positively charged ternary complexes are then analyzed by ESI‐MS in the positive single ion monitoring (SIM) and single reaction monitoring (SRM) modes. The results clearly revealed that the presence of the cationic reagents significantly improved the sensitivity for these analytes, often by several orders of magnitude. This novel method developed herein for the detection of metals improved the limits of detection (LODs) significantly when compared to negative ion mode ESI‐MS and shows great potential in future trace studies of these and many other species. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

9.
Mass spectrometry is widely applied in carbohydrate analysis, but still quantitative evaluation of data is critical due to different ionization efficiencies of the constituents in a mixture. Different size and chemical structure of the analytes cause their uneven distribution in droplets (electrospray ionization, ESI) or matrix spots (matrix-assisted laser desorption/ionization, MALDI). In addition, instrumental parameters affect final ion yields. In order to study and optimize the latter, an equimolar mixture of malto-oligosaccharides (DP1-6) was analyzed using varying target masses for ESI as well as different matrices and laser power for MALDI. The sodium adducts and derivatives for positive ion mode (hydrazones with Girard's T Reagent, GT) and negative ion mode (reductively aminated with o-aminobenzoic acid, oABA) were studied. Negatively charged oABA-labeled malto-oligosaccharides turned out to be unsuitable for quantification of the malto-oligomeric composition. Best agreement was achieved when applying target masses in the range of the highest homolog in the mixture in electrospray ionization ion trap (ESI-IT) (1-2% deviation with GT label or as Na(+) adducts). Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) gave best results when the laser power was adjusted significantly over the desorption/ionization threshold (1% deviation with GT label). Both parameters show significant influence on the determined oligomeric composition. Consequently, estimation and even quantitative determination of amounts of oligosaccharides in a mixture can be achieved when the analytes are labeled and the proper instrumental parameters are used.  相似文献   

10.
A simple, rapid and sensitive method was developed for the simultaneous quantification of chlorogenic acid (CGA) and caffeic acid (CA) in rat plasma using a high-performance liquid chromatography system coupled to a negative ion electrospray mass spectrometric analysis. The plasma sample preparation was a simple deproteinization by the addition of two volumes of acetonitrile followed by centrifugation. The analytes and internal standard ferulic acid were separated on an Intersil C8-3 column (5 mm; 250 x 2.1 mm) with acetonitrile/0.05% triethylamine solution (70:30, v/v) as mobile phase at a flow rate of 0.2 mL/min with an operating temperature of 30 degrees C. Detection was performed on a quadrupole mass spectrometer equipped with an electrospray ionization (ESI) source operated in selected ion monitoring (SIM) mode. Negative ion ESI was used to form deprotonated molecules at m/z 353 for chlorogenic acid, m/z 179 for caffeic acid, and m/z 193 for the internal standard ferulic acid. Linear detection responses were obtained for CGA concentrations ranging from 0.005 to 2.0 microg/mL and for CA concentrations ranging from 0.010 to 2.0 microg/mL and the lower limits of quantitation (LLOQs) for CGA and CA were 0.005 and 0.01 microg/mL, respectively. The intra- and inter-day precisions (RSD%) were within 9.0% for both analytes. Deviation of the assay accuracies was within +/-10.0% for both analytes. Their average recoveries were greater than 88.0%. Both analytes were proved to be stable during all sample storage, preparation and analytic procedures. The method was successfully applied to the pharmacokinetic study of CGA and CA following an intravenous dose of 5 mL/kg mailuoning injection to rats.  相似文献   

11.
陈勇  张玲  王世敏 《分析化学》2004,32(11):1485-1488
应用电喷雾-质谱(ESI-MS)技术研究了原儿茶醛和丹参素的ESI-MS规律,结合ESI-MS技术,对9种丹参水溶性成分的质谱行为进行了研究,并对其中5种成分进行了定性分析。同时利用选择性离子检测质谱技术,初步建立了丹参水溶性成分SIM-MS特征图谱,该图谱简单、易于解析,重现性与特征性较好,可以用于丹参药材及复方丹参的快速指纹鉴别。  相似文献   

12.
A sensitive, rapid and specific method for the simultaneous quantification of oxysophocarpine (OSC) and its active metabolite sophocarpine (SC) in rat plasma was developed and validated, using a liquid-liquid extraction procedure followed by liquid chromatography/electrospray ionization mass spectrometric (LC/ESI-MS) analysis. The separation was performed on a Zorbax Extend-C(18) column (2.1 mm i.d. x 50 mm, 5 microm) with a C(18) guard column using methanol-water containing 5 mm ammonium acetate (15:85, v/v) as mobile phase. Analysis was performed in selected ion monitoring (SIM) mode with an electrospray ionization (ESI) interface. [M + H](+) at m/z 263 for OSC, [M + H](+) at m/z 247 for SC and [M + H](+) at m/z 249 for matrine (internal standard) were selected as detecting ions, respectively. The method was linear in the concentration ranges 10-1000 ng/mL for OSC and 5-500 ng/mL for SC. The intra- and inter-day precisions (coefficient of variation) were within 7% for both analytes. Their accuracy (relative error) ranged from -6.4 to 1.5%. The limits of detection for OSC and SC were 3 and 1.5 ng/mL, respectively. The limits of quantitation for OSC and SC were 10 and 5 ng/mL, respectively. Recoveries of both analytes were greater than 85% at the low, medium and high concentrations. Both analytes were stable during all sample storage, preparation and analytic procedures. The method was successfully applied to a pharmacokinetic study after an oral administration of OSC to rats with a dose of 15 mg/kg.  相似文献   

13.
陈婷  温裕云  欧延  弓振斌 《色谱》2014,32(1):89-94
建立了固相萃取(SPE)净化、超高效液相色谱-串联质谱(UHPLC-MS/MS)测定橡胶制品中13种N-亚硝胺的方法。样品于密闭萃取瓶中于60 ℃下用甲醇超声萃取30 min,C18固相萃取小柱对萃取液进行净化,经C18色谱柱分离,最后用电喷雾正离子(ESI+)和多重反应监测模式(MRM)对13种N-亚硝胺进行定性、定量测定。实验中对样品前处理、色谱分离条件和质谱检测条件进行了优化。在优化的实验条件下,橡胶样品中添加N-亚硝基二甲胺(NDMA)与N-亚硝基-二乙基胺(NDEA)为500 μg/kg、其他组分均为50 μg/kg时,各组分的相对标准偏差(RSD,n=7)小于10%;在实际样品中的加标回收率为70.7%~117.0%;方法的检出限(LOD,以10倍标准偏差计)为0.5~500 μg/kg。方法可应用于橡胶制品中13种N-亚硝胺的测定。  相似文献   

14.
建立了同时测定全血、尿液和肝组织等生物样品中18种氨基甲酸酯类农药的在线固相萃取/液相色谱-线性离子阱质谱(On-line SPE/LC-LIT/MS)分析方法。样品经乙腈处理,稀释和离心后直接进样。经Waters OasisHLB在线SPE柱富集纯化,以BETASIL C18柱为分析柱,甲醇-水(均含0.1%甲酸)为流动相进行梯度洗脱;使用电喷雾电离(ESI)正离子模式测定,扫描方式为选择反应监测(SRM)和连续反应监测(CRM)。18种农药在考察的质量浓度范围内线性关系良好(权重因子1/X),相关系数为0.994 3~0.999 4;在全血和尿液中的检出限为0.1~5 ng/m L,在肝组织中的检出限为0.1~5 ng/g;3个加标水平的回收率为90.2%~114.5%,相对标准偏差(n=4)为0.5%~7.5%。该方法简单准确,灵敏度高,能够满足生物样品中18种氨基甲酸酯类农药的快速分析要求。  相似文献   

15.
液相色谱-串联质谱法同时测定8种花草茶中77种农药残留   总被引:1,自引:0,他引:1  
蓝梦哲  林绪  刘雅琼  王海鸣  曹小彦 《色谱》2018,36(9):938-945
以QuEChERS作为样品前处理手段,采用高效液相色谱-串联质谱(HPLC-MS/MS)检测技术,建立了适用于8种花草茶中77种农药残留同时检测的方法。8种花草茶样品均采用1%(v/v)乙酸乙腈溶液和1 g乙酸铵提取,经4 g无水硫酸镁、0.50 g C18、0.50 g N-丙基乙二胺(PSA)和0.05 g石墨化炭黑(GCB)分散萃取净化,然后采用Venusil MP C18色谱柱分离,以0.1%(v/v)甲酸水溶液和乙腈为流动相梯度洗脱,在电喷雾电离(ESI)源、正负离子交替扫描模式下进行检测,基质匹配标准溶液定量。结果表明,77种农药在0.5~100.0 μ g/L范围内线性关系良好,相关系数大于0.995;77种农药的加标回收率为70.3%~110.0%,相对标准偏差为2.6%~9.8%,检出限为1.0~10.0 μ g/kg。该法灵敏度、准确度和精密度均符合相关农药残留测定的技术要求。  相似文献   

16.
A method was developed for screening crops for a range of pesticide residues by liquid chromatography/tandem mass spectrometry (LC/MS/MS). A complete set of LC, electrospray ionization (ESI), and tandem MS acquisition parameters was established for the determination of 108 analytes; these parameters were used for the simultaneous acquisition of 98 analytes in the positive ESI mode and 10 analytes in an additional MS/MS method in the negative ESI mode. The entire procedure involves extraction of residues with methanol-water and partition into dichloromethane. The utility of the method is demonstrated by the analysis of crops of 5 matrix types (water-containing, acidic, dry, sugar-containing, and fatty). Of 108 pesticides/metabolites tested, 104 showed sufficient stability in most matrixes for determination by LC/MS/MS. These analytes belong to 20 chemical classes, which demonstrate the general applicability of the method for multiclass analysis. By using matrix-matched standards, 67 compounds could be determined in most matrixes with recoveries of 70-120% and a relative standard deviation of < or = 25% at the 0.01 mg/kg level.  相似文献   

17.
A sensitive and rapid method based on liquid chromatography-triple-quadrupole tandem mass spectrometry (LC-MS/MS) with electrospray ionization (ESI) has been developed and validated for the screening and confirmation of 44 exogenous anabolic steroids (29 parent steroids and 15 metabolites) in human urine. The method involves an enzymatic hydrolysis, liquid-liquid extraction, and detection by LC-MS/MS. A triple-quadrupole mass spectrometer was operated in positive ESI mode with selected reaction monitoring (SRM) mode for the screening and product ion scan mode for the confirmation. The protonated molecular ions were used as precursor ions for the SRM analysis and product ion scan. The intraday and interday precisions of the target analytes at concentrations of the minimum required performance levels for the screening were 2-14% and 2-15%, respectively. The limits of detection for the screening and confirmation method were 0.1-10 ng/mL and 0.2-10 ng/mL, respectively, for 44 steroids. This method was successfully applied to analysis of urine samples from suspected anabolic steroid abusers.  相似文献   

18.
We have studied the feasibility of fast high-performance liquid chromatography coupled to electrospray ionization mass spectrometry in the selected ion monitoring mode for the quantitative determination of aspartic acid in an aspartate drug. Internal standardization was required, but mass spectrometric detection allowed for very short retention times of approximately 0.5 min for the analyte and the internal standard without chromatographic separation. The analytical system was found stable, as demonstrated by multiple injections giving a coefficient of variation of 4% for the peak area ratio of aspartic acid and glutamic acid. Calibrations were linear between 0.5 ng and 150 ng aspartic acid injected, with accuracies between 99.8% and 102% found for the back-calculated amounts. Investigation of several drug batches gave reasonable results. Therefore, the method appeared feasible for the determination of aspartic acid in an aspartate drug from 0.3 wt% to 100 wt% aspartic acid.Abbreviations CV coefficient of variation - ESI electrospray ionization - HPLC high-performance liquid chromatography - HSGC headspace gas chromatography - KaFi Karl Fischer titration - MS mass spectrometry - MSD mass-selective detector - % m/m percentage by weight - PAR peak area ratio - r2 coefficient of determination - RP reversed-phase - SIM selected ion monitoringThis work was originally presented as a poster at the Conference of the German Society for Mass Spectrometry, 9–12 March 2003, in Münster, Germany  相似文献   

19.
A sensitive and rapid liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS) method has been developed and validated for the determination of mizolastine in human plasma using dipyridamole as the internal standard (I.S.). Plasma samples were simply pretreated with methanol for deproteinization. Chromatographic separation was performed on an Agilent Zorbax C18 column with a mobile phase of 10 mM ammonium acetate buffer containing 0.1% formic acid–methanol (20:80, v/v) at a flow rate of 1 mL min−1. The electrospray ionization (ESI) interface was employed in a single quadrupole mass spectrometer. The analytes were protonated in the positive ESI interface and detected in single ion monitoring (SIM) mode. Chromatographic separation was achieved in less than 3.5 min. The linearity was established over the range of 0.5–600 ng mL−1. The lower limited of quantification (LLOQ) of the method was 0.5 ng mL−1. The intra- and inter-run standard deviations were both less than 11.2%. The method was applied to study the pharmacokinetics of the mizolastine sustained-release tablets in healthy volunteers.  相似文献   

20.
Electrospray ionization (ESI) efficiency is known to be affected by the properties of the analytes, source design and source parameters. In this study, the ionization efficiency of 17 acidic compounds at various conditions in ESI negative ion mode was evaluated. Namely, the influence of organic solvent content in the mobile phase, ionization source parameters, ionization source geometry and functionality (conventional ESI, ESI with thermal focussing and with additional internal nebulizer gas) was studied. It was observed that the ionization efficiency in thermal focussing ESI is only marginally affected by the organic solvent composition, while for conventional ESI and ESI with internal nebulizer gas, the ionization efficiency increases significantly with increasing organic modifier content. For all ionization sources and mobile phase compositions, the ionization efficiency values between different setups showed good correlation. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号