首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A simple and fast method for determining the content of Na, K, Ca, Mg, P, and 20 heavy metals in biodiesel samples with inductively coupled plasma optical emission spectrometry (ICP OES) using a two-nozzle Flow Blurring® multinebulizer prototype and on-line internal standard calibration, are proposed. The biodiesel samples were produced from different feedstock such as sunflower, corn, soybean and grape seed oils, via a base catalyst transesterification. The analysis was carried out without any sample pretreatment. The standards and samples were introduced through one of the multinebulizer nozzles, while the aqueous solution containing yttrium as an internal standard was introduced through the second nozzle. Thus, the spectral interferences were compensated and the formation of carbon deposits on the ICP torch was prevented. The determination coefficients (R2) were greater than 0.99 for the studied analytes, in the range 0.21–14.75 mg kg−1. Short-term and long-term precisions were estimated as relative standard deviation. These were acceptable, their values being lower than 10%. The LOQ for major components such as Ca, K, Mg, Na, and P, were within a range between 4.9 ng g−1 for Mg (279.553 nm) and 531.1 ng g−1 for Na (588.995 nm), and for the other 20 minor components they were within a range between 1.1 ng g−1 for Ba (455.403 nm) and 2913.9 ng g−1 for Pb (220.353 nm). Recovery values ranged between 95% and 106%.  相似文献   

2.
The concentrations of chromium (III) and (VI) in fly ash from nine Australian coal fired power stations were determined. Cr(VI) was completely leached by extraction with 0.01 M NaOH solution and the concentration was determined by inductively coupled plasma atomic emission spectrometry (ICP-AES). This was confirmed by determining Cr(III) and Cr(VI) in the extracts of fly ash that had been spiked with chromium salts. These analytical measurements were done using a combination of ion-exchange chromatography and ICP-AES. The elutant was 0.05 M HNO3 containing 0.5%-CH3OH. When the column was operated at a flow rate of 1.2 ml min−1 and samples were injected by use of a sample loop with a volume of 100 μl, Cr(III) and Cr(VI) in sample solution was exclusively separated within approximately 10 min. The detection limits (3σ) were 5 ng for Cr(III) (0.050 mg l−1) and 9 ng for Cr(VI) (0.090 mg l−1), respectively. A relative standard deviation of 1.9% (n = 6) was obtained for the determination by IC-ICP-AES of 0.25 mg l−1 Cr(III) and Cr(VI).  相似文献   

3.
The concentrations of Cu, Zn, Mn, Fe, K, Ca, Mg, Al, Ba and B in 26 herbal drugs of special importance in phytopharmacy were studied. Flame atomic absorption and emission spectrometry (FAAS, FAES), as well as inductively coupled plasma atomic emission spectrometry (ICP-AES), were applied in this work. The whole procedure, from sample preparation, via dissolution, to measurements, was validated by using CRM (NIST 1573a—tomato leaves), and the obtained recovery values are in the range from 91 to 102%. Drug samples originated from medicinal plants cultivated in Serbia contained Cu (4.47-14.08 mg kg−1), Zn (8.4-54.5 mg kg−1), Mn (9-155 mg kg−1), Fe (47-546 mg kg−1), K (0.20-6.24%), Ca (0.18-1.84%), Mg (0.13-1.09%), Al (16-416 mg kg−1), Ba (11.70-84.83 mg kg−1) and B (5.1-118.7 mg kg−1). In order to get a better insight into the elemental patterns, a common chemometric approach to data evaluation was used. Four significant factors identified by principal component analysis (PCA) were attributed partly to the significant influential sources and high mobility of some elements thus referring to potential anthropogenic contamination as well.  相似文献   

4.
Mineral content and botanical origin of Spanish honeys   总被引:2,自引:0,他引:2  
Eleven elements (Zn, P, B, Mn, Mg, Cu, Ca, Ba, Sr, Na and K) were determined by inductively plasma coupled spectrometry in 40 honey samples from different places of Spain and four different botanical origins: Eucalyptus (Eucalyptus sp.), Heather (Erica sp.), Orange-blossom (Citrus sinensis) and Rosemary (Rosmarinus officinalis). K, Ca and P show the higher levels with average concentrations ranged between 434.1-1935 mg kg−1 for K; 42.59-341.0 mg kg−1 for Ca and 51.17-154.3 mg kg−1 for P. Levels of Cu (0.531-2.117 mg kg−1), Ba (0.106-1.264 mg kg−1) and Sr (0.257-1.462 mg kg−1) are the lowest in all honey samples. Zn (1.332-7.825 mg kg−1), Mn (0.133-9.471 mg kg−1), Mg (13.26-74.38 mg kg−1) and Na (11.69-218.5 mg kg−1) concentrations were found strongly dependent on the kind of botanical origin.Results were submitted to pattern recognition procedures, unsupervised methods such as cluster and principal components analysis and supervised learning methods like linear discriminant analysis in order to evaluate the existence of data patterns and the possibility of differentiation of Spanish honeys from different botanical origins according to their mineral content. Cluster analysis shows four clusters corresponding to the four botanical origins of honey and PCA explained 71% of the variance with the first two PC variables. The best-grouped honeys were those from heather; eucalyptus honeys formed a more dispersed group and finally orange-blossom and rosemary honeys formed a less distinguishable group.  相似文献   

5.
Reference materials for quantitative determination of Cd, Cr, Hg and Pb in polycarbonate were developed. Reference materials with two concentration level of elements were prepared by adding appropriate amounts of chemicals to a blank polycarbonate base material. It was shown that ten bottles with triplicate analysis are enough to demonstrate the homogeneity of these candidate reference materials. The statistical results also showed no significant trends in both short-term stability test for four weeks and long-term stability test for twelve months. The certification of the four elements was carried out by isotope-dilution-inductively coupled plasma mass spectrometry (ID-ICP-MS) with microwave-assisted digestion. Certification of candidate reference materials in a single laboratory was confirmed with interlaboratory comparison participated by a certain number of well-recognized testing laboratories in Korea. The certified values and expanded uncertainties (k = 2) for the candidate reference material with low level and the one with high level were (51.7 ± 2.1) mg kg−1 Cd, (103.8 ± 2.9) mg kg−1 Cd, (98.8 ± 4.5) mg kg−1 Cr, (1004 ± 49.8) mg kg−1 Cr, (107.4 ± 4.6) mg kg−1 Hg, (1133 ± 50.7) mg kg−1 Hg, (94.8 ± 3.7) mg kg−1 Pb and (988.4 ± 53.6) mg kg−1 Pb, respectively. The reference materials developed in this study demonstrated their suitability for the quality assurance in Cd, Cr, Hg and Pb analysis for the implementation of RoHS Directive.  相似文献   

6.
B.D. Real  L.A. Sarabia 《Talanta》2007,71(4):1599-1609
Using a central composite design, the signal of the process for the spectrophotometric determination of hexavalent chromium (λ = 543 nm) is maximised and its variability minimised using as complexing agent 1,5-diphenylcarbazide in sufficiently acid medium. To analyse the interference of various analytes (Mo(VI), V(V), Fe(III) and Mn(VII)) on the Cr(VI) as a function of concentration of interferent, a factorial design was prepared at three levels of each (zero, medium and high concentration), which implies performing 81 determinations. However, a D-optimal design with just nine experiments is sufficiently good to estimate the model proposed.The interference of these metals makes it impossible to determine Cr(VI) when they are present in the sample. To avoid prior separation steps, a multivariate regression by partial least squares, PLS, is proposed to calibrate the Cr(VI) in the presence of these analytes varying the concentration of the Cr(VI) between 0.1 and 0.9 μg ml−1 and that of the interferents between 3 and 5 μg ml−1. The average errors obtained were 4.5% and 3.29% fitted and in prediction, respectively, with a standard error in prediction (RMSEP) of 0.016% presenting absence of both constant and proportional bias.The detection limit with the PLS regression in the presence of interferents is 0.1 μg ml−1 with a probability of false positive equal to 5% and less than 5% for false negative. The capability of detection is similar to that obtained with the univariate calibration (absorbance at 543 nm) in absence of interferents.With the PLS regression it is possible to discriminate 0.085 μg ml−1 of Cr(VI) in a sample with 0.5 μg ml−1 of Cr(VI) with probabilities of false compliance and false non-compliance equal to 0.05. For the univariate calibration without interferents, it was established at 0.0971 μg ml−1 of Cr(VI) for the same nominal concentration.In relation to interference of V(V), Fe(III) and Mn(VII), the PLS calibration could be an efficient alternative to the separation step for Cr(VI) spectrophotometric determination using 1,5-diphenylcarbazide.  相似文献   

7.
Enrichment techniques have become an important feature in the trace analysis of oestrogen mimicking chemicals in the environment. Recent developments such as accelerated solvent extraction (ASE) have improved extraction recoveries in a wide variety of solid matrices including sediments, sludges and leachate soils. Such samples taken from the Irish Midlands Shannon Catchment region during the winter of 2004/5 and suspected to contain certain xenooestrogens or hormonally active agents were extracted using this technique, which was then coupled with high performance liquid chromatography (HPLC) for quantification purposes. ASE was thus employed to both isolate and pre-concentrate targeted analytes using the minimum amount of solvent hence making extractions more conservational. Two simple, yet extremely sensitive liquid chromatographic methods were developed based on UV detection; one for phthalates and one for alkylphenols, with recoveries reaching up to 92.0%. Acid digestion was used for the extraction of the tin and organotin compounds with analysis by polarography. In river sediment, levels of up to 24.4 mg kg−1 phthalate, 1.14 mg kg−1 4-nonylphenol and 118 mg kg−1 tin were found. In leachate sediments, values up to 49.8 mg kg−1 phthalate, 1.57 mg kg−1 4-nonylphenol, and 36.0 mg kg−1 tin were determined. In sludge, values up to 174 mg kg−1 phthalate and 22.8 mg kg−1 4-nonylphenol were quantified. The highest value of tin (118 mg kg−1) was found present in an area of high leisure craft activity. Typical sediment levels of tin at other river locations ranged between 1.20 and 37.5 mg kg−1.  相似文献   

8.
Wu Y  Jiang Z  Hu B 《Talanta》2005,67(4):854-861
A simple and selective method of flow injection (FI) using a micro-column packed with quinine modified resin as solid phase extractant has been developed for preconcentration and separation of trace amount of vanadium(V) and vanadium(IV) in water samples, followed by determination with fluorination assisted electrothermal vaporization (FETV)-inductively coupled plasma optical emission spectrometry (ICP-OES). At pH 3 ∼ 3.8, the modified resin is selective towards V(V) and almost not towards V(IV), while, V(IV) could be quantitatively adsorbed by the modified resin at pH 5 ∼ 7. The two vanadium species adsorbed by modified resin could be readily desorbed quantitatively with 0.3 ml of 0.5 mol l−1 HCl. Both vanadium species in elution were then determined by ETV-ICP-OES with the use of polytetrafluoroethylene (PTFE) as chemical modifier. Effects of acidity, sample flow rate, concentration of elution solution and interfering ions on the recovery of the analytes have been systematically investigated. Under the optimal conditions, the adsorption capacities of the quinine modified resin for V(V) and V(IV) are 7.6 and 8.0 mg g−1, respectively. The detection limit (3σ) of V is 0.072 ng ml−1 for FETV-ICP-OES and 0.56 pg ml−1 for FETV-ICP-MS with enrichment factor of 62.5, and the relative standard deviation (R.S.D.) is 4.9% (n = 9, C = 0.2 μg ml−1) and 3.8% (n = 9, C = 1.0 ng ml−1), respectively. The proposed method has been applied to the determination of trace V(V) and V(IV) in different water samples, and the recoveries of V(V) and V(IV) are 100 ± 10%. In order to further verify the accuracy of the developed method, FETV-ICP-MS was employed to analyze the vanadium species in water samples after separation/preconcentration, and analytical results are in good agreement with that obtained by the proposed method. The developed method was also applied to the analysis of the total V in GBW07401 soil certified reference material and in GBW07605 tea leaves certified reference material, and the determined values coincided with the certified values very well.  相似文献   

9.
Xu Y  Zhou J  Wang G  Zhou J  Tao G 《Analytica chimica acta》2007,584(1):204-209
Inductively coupled plasma atomic emission spectrometry (ICP-AES) was applied to the determination of lead, arsenic, nickel and cobalt in high-purity iron oxide pigment. Samples were dissolved with hydrochloric acid and hydrogen peroxide. The digest was passed through a column, which was packed with a polymer resin containing a neutral organophosphorus extractant, tri-n-butylphosphate. Iron was sorbed selectively on the resin and the analytes of interest passed through the column, allowing the effective separation of them from the iron matrix. Conditions of separation were optimized. The detection limits (3σ) in solution were 10, 40, 7 and 5 μg L−1, and in pigment were 0.2, 0.8, 0.14 and 0.1 mg kg−1 for lead, arsenic, cobalt and nickel, respectively. The recoveries ranged from 95% to 107% when sample digests were spiked with 5 μg of the analytes of interest, and relative standard deviations (n = 6) were 1.5-17.6% for the determination of the spiked samples. The method was successfully applied to the determination of trace amounts of these elements in high-purity iron oxide pigment samples.  相似文献   

10.
The aim of this study was to develop a fast capillary electrophoresis method for the determination of inorganic cations (Na+, K+, Ca2+, Mg2+) in biodiesel samples, using barium (Ba2+) as the internal standard. The running electrolyte was optimized through effective mobility curves in order to select the co-ion and Peakmaster software was used to determine electromigration dispersion and buffer capacity. The optimum background electrolyte was composed of 10 mmol L−1 imidazole and 40 mmol L−1 of acetic acid. Separation was conducted in a fused-silica capillary (32 cm total length and 23.5 cm effective length, 50 μm I.D.), with indirect UV detection at 214 nm. The migration time was only 36 s. In order to obtain the optimized conditions for extraction, a fractional factorial experimental design was used. The variables investigated were biodiesel mass, pH, extractant volume, agitation and sonication time. The optimum conditions were: biodiesel mass of 200 mg, extractant volume of 200 μL and agitation of 20 min. The method is characterized by good linearity in the concentration range of 0.5-20 mg kg−1 (r > 0.999), limit of detection was equal to 0.3 mg kg−1, inter-day precision was equal to 1.88% and recovery in the range of 88.0-120%. The developed method was successfully applied to the determination of cations in biodiesel samples.  相似文献   

11.
A method is described for quantification of sulfur at low concentrations on the order of mg kg−1 in biodiesel and diesel fuels using isotope dilution and sector field inductively coupled plasma mass spectrometry (ID-SF-ICP-MS). Closed vessel microwave-assisted digestion was employed using a diluted nitric acid and hydrogen peroxide decomposition medium to reduce sample dilution volumes. Medium resolution mode was employed to eliminate isobaric interferences at 32S and 34S related to polyatomic phosphorus and oxygen species, and sulfur hydride species. The method outlined yielded respective limits of detection (LOD) and limits of quantification (LOQ) of 0.7 mg kg−1 S and 2.5 mg kg−1 S (in the sample). The LOD was constrained by instrument background counts at 32S but was sufficient to facilitate value assignment of total S mass fraction in NIST SRM 2723b Sulfur in Diesel Fuel Oil at 9.06 ± 0.13 mg kg−1. No statistically significant difference at a 95% confidence level was observed between the measured and certified values for certified reference materials NIST SRM 2773 B100 Biodiesel (Animal-Based), CENAM DRM 272b and NIST SRM 2723a Sulfur in Diesel Fuel Oil, validating method accuracy.  相似文献   

12.
A novel, inexpensive and fast method based on the electrooxidation of glycerol on platinum electrodes by the potential cycling technique has been designed for the determination of free glycerol in biodiesel. A wide range of linearity was achieved between 15 and 150 mg L−1 (0.16 and 1.6 mmol L−1), which corresponds to concentrations ranging between 56 and 560 mg kg−1 (glycerol:biodiesel) for an extraction using 2 g biodiesel. A method for the fast extraction of glycerol from biodiesel with water followed by elimination of organic interferents has also been developed, so that the novel determination method can be applied to various biodiesel samples. The excellent repeatability allows determination of glycerol in numerous samples, with no need for recalibration.  相似文献   

13.
In this work, two kinds of chelating resin, bis(2-aminoethylthio)methylated resin (BAETM) and γ-aminobutyrohydroxamate resin (γ-ABHX) were synthesized. Of these, the former has a hydrophobic skeleton, and the latter a hydrophilic skeleton. The functionalities of each were 0.91 and 2.21 mmol g−1, respectively. The chelating behavior of these resins towards vanadium, molybdenum and tungsten as a function of pH was studied. To perform trace metals analysis in complex matrices, a hyphenated method-chelation ion chromatography (CIC) coupled on-line detection with inductively coupled plasma mass spectrometry (ICP-MS) was developed. With a BAETM resin column (5×0.4 cm i.d.) as the separator, a sample volume of 20 μl, nitric acid (pH 1.5) as the eluent and a flow rate of 1 ml min−1, the detection limits for the determination of vanadium, molybdenum and tungsten were lower than 0.05 ng ml−1and the linear ranges were up to 100 ng ml−1 for each element. By increasing the injected sample volume to 250 μl, the resin concentrator improved the detection limit to 0.01 ng ml−1. For the determination of these elements (5 ng ml−1 for each) spiked in artificial sea water samples, γ-ABHX resin column (3×0.6 cm i.d.) demonstrated well resolved peak separation between the analytes and the matrix elements—calcium and magnesium, by using sodium nitrate (10 ml, 10−4 M) as the eliminator.  相似文献   

14.
In this work, a non-chromatographic procedure for the on-line determination of ultratraces of V(V) and V(IV) is presented. The method involves a solid phase extraction-flow injection system coupled to electrothermal atomic absorption spectrometry (SPE-FI-ETAAS). The system holds two microcolumns (MC) set in parallel and filled with lab-made mesoporous silica functionalized with 3-aminopropyltriethoxy silane (APS) and mesoporous silica MCM-41, respectively. The pre-concentration of V(V) is performed by sorption onto the first MC (C1) filled with APS at pH 3, whilst that of V(IV) is performed by sorption onto the second column (C2) filled with mesoporous silica MCM-41 at pH 5. Aqueous samples containing both analytes are loaded and, after pre-concentration (pre-concentration factor PCF = 10, sorption flow rate = 1 mL min−1, sorption time = 10 min), they are eluted in separate vessels with hydroxylammonium chloride (HC) 0.1 mol L−1 in HCl 0.5 mol L−1 (elution volume = 1 mL, elution flow rate = 0.5 mL min−1). Afterwards, both analytes are determined through ETAAS with graphite furnace. Under optimized conditions, the main analytical figures of merit for V(V) and V(IV) are, respectively: detection limits (3 s): 0.5 and 0.6 μg L−1, linear range: 2-100 μg L−1 (both analytes), sensitivity: 0.015 and 0.013 μg−1 L and sample throughput: 6 h−1 (both analytes). Recoveries of both species were assayed in different water samples. Validation was performed through certified reference materials for ultratraces of total vanadium in river water.  相似文献   

15.
Cobalt is used as chemical modifier to improve sensitivity and minimize matrix effects in Cr determinations by tungsten coil atomic emission spectrometry (WCAES). The atomizer is a tungsten filament extracted from microscope light bulbs. A solid-state power supply and a handheld CCD-based spectrometer are also used in the instrumental setup. In the presence of 1000 mg L−1 Co, WCAES limit of detection for Cr (λ = 425.4 nm) is calculated as 0.070 mg L−1; a 10-fold improvement compared to determinations without Co modifier. The mechanism involved in such signal enhancement is similar to the one observed in ICP OES and ICP-MS determinations of As and Se in the presence of C. Cobalt increases the population of Cr+ by charge transfer reactions. In a second step, Cr+/e recombination takes place, which results in a larger population of excited-state Cr atoms. This alternative excitation route is energetically more efficient than heat transfer from atomizer and gas phase to analyte atoms. A linear dynamic range of 0.25–10 mg L−1 and repeatability of 3.8% (RSD, n = 10) for a 2.0 mg L−1 Cr solution are obtained with this strategy. The modifier high concentration also contributes to improving accuracy due to a matrix-matching effect. The method was applied to a certified reference material of Dogfish Muscle (DORM-2) and no statistically significant difference was observed between determined and certified Cr values at a 95% confidence level. Spike experiments with bottled water samples resulted in recoveries between 93% and 112%.  相似文献   

16.
Silva SG  Rocha FR 《Talanta》2010,83(2):559-564
A flow system designed with solenoid micro-pumps is proposed for fast and greener spectrophotometric determination of free glycerol in biodiesel. Glycerol was extracted from samples without using organic solvents. The determination involves glycerol oxidation by periodate, yielding formaldehyde followed by formation of the colored (3,5-diacetil-1,4-dihidrolutidine) product upon reaction with acetylacetone. The coefficient of variation, sampling rate and detection limit were estimated as 1.5% (20.0 mg L−1 glycerol, n = 10), 34 h−1, and 1.0 mg L−1 (99.7% confidence level), respectively. A linear response was observed from 5 to 50 mg L−1, with reagent consumption estimated as 345 μg of KIO4 and 15 mg of acetylacetone per determination. The procedure was successfully applied to the analysis of biodiesel samples and the results agreed with the batch reference method at the 95% confidence level.  相似文献   

17.
This study proposes a procedure for determining sodium, potassium, calcium and magnesium in biodiesel samples by flame atomic absorption spectrometry (F AAS). The sample was prepared as a microemulsion without surfactant. The optimized composition of the microemulsion was 10% (w/v) biodiesel, 75% (v/v) n-propanol, 1% (v/v) concentrated nitric acid and 14% (v/v) of aqueous solution formed by 0.2% (v/v) of nitric acid and 0.5% (v/v) of ionization suppressor. Analyte signals in the samples as microemulsion were found to be stable for a period of 15 days. Analytical curves were obtained using organometallic standard solutions. The limits of detection (LOD) found for the proposed procedure were 0.1 µg g− 1, 0.01 µg g− 1, 0.04 µg g− 1, and 0.004 µg g− 1 for Na, K, Ca and Mg, respectively. The reference method established by ABNT (Brazilian Association of Technical Norms) NBR 15556:2008 was used to verify the accuracy of the proposed procedure. No significant statistical difference was found between the results obtained with the proposed and the chosen reference procedure. The proposed procedure showed no matrix influence when recovery tests were performed (89%-103%). The results found in this study show that the proposed procedure is a good alternative for determining Na, K, Ca, and Mg by F AAS in biodiesel samples.  相似文献   

18.
The usefulness of the secondary line at 252.744 nm and the approach of side pixel registration were evaluated for the development of a method for sequential multi-element determination of Cu, Fe, Mn and Zn in soil extracts by high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS). The influence of side pixel registration on the sensitivity and linearity was investigated by measuring at wings (248.325, 248.323, 248.321, 248.329, and 248.332 nm) of the main line for Fe at 248.327 nm. For the secondary line at 252.744 nm or side pixel registration at 248.325 nm, main lines for Cu (324.754 nm), Mn (279.482 nm) and Zn (213.875 nm), sample flow-rate of 5.0 mL min−1 and calibration by matrix matching, analytical curves in the 0.2-1.0 mg L−1 Cu, 1.0-20.0 mg L−1 Fe, 0.2-2.0 mg L−1 Mn, 0.1-1.0 mg L−1 Zn ranges were obtained with linear correlations better than 0.998. The proposed method was applied to seven soil samples and two soil reference materials (IAC 277; IAC 280). Results were in agreement at a 95% confidence level (paired t-test) with reference values. Recoveries of analytes added to soil extracts containing 0.15 and 0.30 mg L−1 Cu, 7.0 and 14 mg L−1 Fe, 0.60 and 1.20 mg L−1 Mn, 0.07 and 0.15 mg L−1 Zn, varied within the 94-99, 92-98, 93-101, and 93-103% intervals, respectively. The relative standard deviations (n = 12) were 2.7% (Cu), 1.4% (Fe - 252.744 nm), 5.7% (Fe - 248.325 nm), 3.2% (Mn) and 2.8% (Zn) for an extract containing 0.35 mg L−1 Cu, 14 mg L−1 Fe, 1.1 mg L−1 Mn and 0.12 mg L−1 Zn. Detection limits were 5.4 μg L−1 Cu, 55 μg L−1 Fe (252.744 nm), 147 μg L−1 Fe (248.325 nm), 3.0 μg L−1 Mn and 4.2 μg L−1 Zn.  相似文献   

19.
A simple and sensitive multicommutated flow procedure, implemented by employing a homemade light emitting diode (LED) based photometer, has been developed for the determination of chromium (VI) and total chromium in water. The flow system comprised a set of four solenoid micro-pumps, which were assembled to work as fluid propelling and as commutating devices. The core of the detection unit comprised a green LED source, a photodiode and a homemade flow cell of 100 mm length and 2 mm inner diameter. The photometric procedure for the speciation of chromium in natural waters was based on the reaction of Cr (VI) with 1,5-diphenylcarbazide. Cr (III) was previously oxidized to Cr (VI) and determined as the difference between total Cr and Cr (VI). After carrying out the assays to select the best operational conditions the features of the method included: a linear response ranging from 10 to 200 μg l−1 Cr (III) and Cr (VI) (r = 0.999, n = 7); limits of detection of 2.05 and 1.0 μg l−1 for Cr (III) and Cr (VI), respectively; a relative standard deviation lower than 2.0% (n = 20) for a typical solution containing 50 μg l−1 Cr; a sampling throughput of 67 and 105 determinations per hour for total Cr and Cr (VI), respectively, and recovery values within the range of 93-108% for spiked concentrations of the order of 50 μg l−1.  相似文献   

20.
A new solvent-free analytical procedure based on headspace solid-phase microextraction (SPME) coupled to gas chromatography employing an electron capture detector (GC/ECD) or alternatively a mass spectrometric detector (GC/MSD) has been developed for the determination of phthalic acid esters (dimethyl-[DMP], diethyl-[DEP], di-n-butyl-[DnBP], butylbenzyl-[BBP], di-2-ethylhexyl-[DEHP] and di-n-octyl [DnOP] phthalate) in vegetable oils. Four different fiber coatings were evaluated, among them polydimethylsiloxane with a thickness of 100 μm appeared to be the best choice for allowing extraction of the whole group of analytes. Various solvents were tested as sample matrix modification agents with the aim to facilitate the transfer of esters with low vapour pressure (DEHP and DnOP) from oil matrix into the headspace. The addition of methanol resulted in optimal set-up applicable for all phthalate esters. Temperature control and the way of sample stirring were recognized as critical points of the whole procedure. Primarily, because shaking rather than stirring of the sample is carried out using a CombiPal multipurpose sampler, the automation of the SPME method employing this instrument was found to be not fully suitable for efficient stripping of phthalates from the oil matrix into the sample headspace. Nevertheless, the optimized manual SPME method, encompassing GC/ECD or GC/MSD for the separation and detection of target analytes, offers a unique solution and showed acceptable performance characteristics: linear response in the range of 0.5-2 mg kg−1 and repeatability expressed as R.S.D. between 14 and 23% at the spiking level of 2 mg kg−1.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号