首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到8条相似文献,搜索用时 0 毫秒
1.
Nickel sulphide-reduced graphene oxide (NiS-rGO) composite films have been prepared via modified Hummers’s method assisted with spin coating technique. The NiS-rGO samples were then employed as counter electrode in a dye-sensitized solar cell (DSSC). The main aim of this work is to investigate the relationship between the concentrations of NiCl2 with the properties of NiS-rGO and performance parameters of the device. The dominant rGO and minor NiS phase exist in the composite. The morphology of the composite is white strips rGO and NiS agglomerate particle. The element of C, O, Ni and S present in the composite. The highest η of 1.04% and Jsc of 7.39 mA cm−2 were obtained from the device with 0.06 M NiCl2 resulted from the longest carrier lifetime. The photovoltaic parameters results reveal that NiS-rGO composite has potential to become as a free platinum counter electrode of DSSC.  相似文献   

2.
Vastarella W  Nicastri R 《Talanta》2005,66(3):627-633
In this work quantum-sized CdS nanocrystals were synthesized using a quaternary water-in-oil microemulsion and immobilized onto gold working electrode by self-assembled monolayers techniques. Formaldehyde dehydrogenase was covalently immobilized onto a protecting membrane, which was stratified on part of the semiconductor nanoparticles modified electrode. The covalent enzyme immobilization has been required to improve the stability of the catalytic oxidation of formaldehyde, which occurs after light stimulation of the semiconductor through the electron/hole recombination. A study about the best electrochemical oxidation potentials under different flow conditions was performed. Preliminary sensor stability and interferences tests were also carried out, for a sensitive and selective detection of formaldehyde. A detection limit of 41 ppb of formaldehyde was calculated and an operational stability of 6 h was achieved under flow conditions by means of this novel amperometric biosensor based on FDH-semiconductor hybrid systems, not requiring NAD+/NADH as charge transfer in the enzymatic reaction.  相似文献   

3.
Tap water samples (Assiut city, lie in the middle north of upper Egypt, approx. 370 km from Cairo, January-March, 2002) were taken from the eight sampling sites of different locations at Assiut city. The samples are analyzed to determine the total content of cadmium, copper, lead and zinc by differential pulse anodic stripping voltammetry (DPASV) while nickel and cobalt are determined by a new simple differential pulse adsorptive stripping voltammetry (DPAdSV), using dimethylglyoxime (DMG) as the complexing agent. This method uses sodium sulfite as the supporting electrolyte, which facilitates the removal of oxygen interference without the traditional necessity of purging with inert gas. The effect of various parameters was studied using DPASV (for Cd, Pb, Cu and Zn) and AdSV (for Ni and Co) methods. Subsequently, under the so found experimental conditions, the stability of calibration curves and the detection limits (μg/l) have been determined. The data achieved (for all metals utility) are comparable to those measured by the graphite furnace atomic absorption spectrophotometric (GF-AAS) method. The effects of the interferences between these metal ions have been investigated. Moreover, the effect of storage was discussed and the obtained results were compared favorably with standard official methods. Statistical analysis of the database exhibits applicability and the accuracy of the techniques. The results obtained from the two techniques (Voltammetry and GF-AAS) are in very good agreements in the most tap water samples.  相似文献   

4.
A room temperature ionic liquid (IL) composed of a quaternary alkylphosphonium (trihexyltetradecylphosphonium, P66614+) and tetrakis(pentafluorophenyl)borate anion (TB) was employed within a water|P66614TB (w|P66614TB or w|IL) biphasic system to evaluate cesium ion extraction in comparison to that with a traditional water|organic solvent (w|o) combination. 137Cs is a major contributor to the radioactivity of spent nuclear fuel as it leaves the reactor, and its extraction efficiency is therefore of considerable importance. The extraction was facilitated by the ligand octyl(phenyl)-N,N′-diisobutylcarbamoylphosphine oxide (CMPO) used in TRans-Uranium EXtraction processes and investigated through well established liquid|liquid electrochemistry. This study gave access to the metal ion to ligand (1:n) stoichiometry and overall complexation constant, β, of the interfacial complexation reaction which were determined to be 1:3 and 1.6 × 1011 at the w|P66614TB interface while the study at w|o elicited an n equal to 1 with β equal to 86.5. Through a straightforward relationship, these complexation constant values were converted to distribution coefficients, δα, with the ligand concentrations studied for comparison to other studies present in the literature; the w|o and w|IL systems gave δα of 2 and 8.2 × 107, respectively, indicating a higher overall extraction efficiency for the latter. For the w|o system, the metal ion-ligand stoichiometries were confirmed through isotopic distribution analysis of mass spectra obtained by the direct injection of an emulsified water–organic solvent mixture into an electron spray ionization mass spectrometer.  相似文献   

5.
The combination of electrochemistry (EC) and mass spectrometry (MS) has become a more and more frequently used approach in metabolism studies in the last decade. This review provides insight into the importance of metabolism studies during the drug development process and gives a short overview about the conventionally used methods since electrochemistry is often intended to substitute or minimize animal-based studies. The optimization of the electrochemical conditions is of great importance for a successful comparison with in vitro approaches. The type of metabolism reactions, which can be simulated by EC, has been extended with new cell types and working electrodes. Although the mechanism differs from the enzyme-catalyzed turnover, electrochemistry can be used to simulate a significant number of the respective reactions.  相似文献   

6.
Herein, highly efficient solid-state ECL sensor was introduced for the first time onto the screen printed electrodes of the paper-based chips (PCs) based on the composite film of poly(sodium 4-styrenesulfonate) functionalized graphene (PSSG) and Nafion. Attributed to the cooperative characteristics of both PSS and graphene, PSSG ensured both effective Ru(bpy)32+ immobilization and fast electron transfer of Ru(bpy)32+ in the composite film. The ECL behaviors at the developed sensor were investigated using tripropylamine as a representative analyte and low detection limit (S N−1 = 3) of 5.0 nM was obtained. It also exhibited more excellent reproducibility (relative standard deviations of 0.63% for continuous 45 cycles) and long-term stability (∼80% of its initial ECL intensity could be retained over 3 months). More importantly, assisted by the developed ECL sensor, discrimination of 1.0 nM single-nucleotide mismatch in human urine matrix could be realized on the PCs for the first attempt. Thus, the developed sensor was confirmed with the advantages of highly sensitivity, long-term stability, simplicity, low cost, disposability, high efficiency and potential applicability.  相似文献   

7.
The unique electronic properties and miniaturized dimensions of silicon nanowires (SiNWs) are attractive for label-free, real-time and sensitive detection of biomolecules. Sensors based on SiNWs operate as field effect transistors (FETs) and can be fabricated either by top–down or bottom–up approaches. Advances in fabrication methods have allowed for the control of physicochemical and electronic properties of SiNWs, providing opportunity for interfacing of SiNW-FET probes with intracellular environments. The Debye screening length is an important consideration that determines the performance and detection limits of SiNW-FET sensors, especially at physiologically relevant conditions of ionic strength (>100 mM). In this review, we discuss the construction and application of SiNW-FET sensors for detection of ions, nucleic acids and protein markers. Advantages and disadvantages of the top–down and bottom–up approaches for synthesis of SiNWs are discussed. An overview of various methods for surface functionalization of SiNWs for immobilization of selective chemistry is provided in the context of impact on the analytical performance of SiNW-FET sensors. In addition to in vitro examples, an overview of the progress of use of SiNW-FET sensors for ex vivo studies is also presented. This review concludes with a discussion of the future prospects of SiNW-FET sensors.  相似文献   

8.
Paper-based analytical devices have become lately “must have” components in equipment and instrumental designed for point-of-care applications, especially when they are used in tandem with microfluidic platforms. Nowadays, paper-based electrochemical devices (PEDs) represent the first choice in the development of lab-on-a-chip biosensors because of their benefits in biomedical diagnosis in terms of simplicity, affordability, portability, and disposability. Moreover, cellulose is a biodegradable and biocompatible substrate, ideal for building disposable devices for use in remote locations or low-resource settings. Despite their low costs and simplicity, PEDs must face a tough challenge—meeting the affordable, sensitive, specific, user-friendly, rapid and robust, equipment-free, and deliverable to end users criteria. The latest achievements in microfluidic PEDs for clinical diagnosis will be critically discussed, putting emphasis on innovative assay formats and methods for surface modification.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号