首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A quantitative method for the determination of organic acids in atmospheric particles is developed. The method couples a derivatisation step (thermally assisted hydrolysis and methylation) and a Curie point pyrolyser as a thermal desorption technique and gas chromatography–mass spectrometry (CPP-GC–MS). Among the reagents tested (tetramethylammonium hydroxide (TMAH), tetramethylammonium acetate (TMAAc) and phenyltrimethylammonium hydroxide (TMPAH)), the best performance was found using TMAAc as a derivatisation reagent for the reaction time of 4 s at 510 °C as heating temperature. Calibration was performed for a series of fatty acids (FA), dicarboxylic acids (DCA) and terpenoic acids (TA) under these conditions. Coefficients of determination (R2) were between 0.94 and 0.98. Limits of detection (LOD) were in the nanogram-range between 0.1 and 3.6 ng. The method is applied on atmospheric particle samples to obtain the quantification reproducibility and quantification limits. Reproducibility was determined in terms of relative standard deviations (RSD) for ambient aerosol samples collected by a high-volume-sampler (HVS, RSD = 6–45%, n = 10) and a Berner impactor (BI, RSD = 5–34%, n = 10). Based on 24 h sampling time the developed method enables quantification of all three classes of acids for both sampling techniques. Calibration data and presented volume concentrations are compared with literature data. A comparison with an off-line methylation-GC–MS using BF3 as a derivatisation reagent and capillary electrophoresis coupled mass spectrometry (CE-MS) showed a good agreement. Minimal sample preparation is the main advantage of the developed method. Depending on the sensitivity requirements the present method can be a fast and simple alternative to GC–MS techniques with conventional sample preparation steps for semi-volatile organic acids.  相似文献   

2.
We performed the quantification of phosphorus in deoxynucleotides using capillary electrophoresis (CE) and micro-HPLC (μHPLC) hyphenated with inductively coupled plasma mass spectrometry (ICP-MS). DNA and its component units have conventionally been determined by photometry; however, more selective and sensitive methods are needed for small biological samples. CE and μHPLC offer the advantages of good separation and small consumption of samples, and ICP-MS is a highly sensitive technique for the determination of a chemical element. Therefore, we have developed an interface device for combining CE and μHPLC with ICP-MS for quantifying nucleotides based on phosphorus content. The interface utilizes 4.5 μL/min for nebulizing and effective introduction of the sample into ICP. The samples of nucleotides and free phosphoric acid were well separated in the CE–ICP-MS measurement, and the calibration curves (1–100 μg/mL) of the nucleotides showed a linear (R2 > 0.999) increase in intensity. Similarly, the samples of nucleotides were baseline separated using μHPLC–ICP-MS, and the calibration curves of the nucleotides were linear (R2 > 0.998). The detection limits of these species and phosphorus in nucleotides using CE–ICP-MS and μHPLC–ICP-MS were 0.77–6.5 ng/mL and 4.0–6.5 ng/mL, respectively. These values were about one or two orders lower than those in a previous report. The sample volumes of these experiments were calculated to be about 10 nL and 50 nL per analysis. Therefore, these analytical methods have the potential to be useful for the determination of biological samples, such as DNA and RNA molecules.  相似文献   

3.
An amplified electrochemical impedimetric aptasensor for ochratoxin A (OTA) was developed with picomolar sensitivity. A facile route to fabricate gold nanoparticles covalently bound reduced graphene oxide (AuNPs–rGO) resulted in a large number of well-dispersed AuNPs on graphene sheets with tremendous binding sites for DNA, since the single rGO sheet and each AuNP can be loaded with hundreds of DNA strands. An aptasensor with sandwich model was fabricated which involved thiolated capture DNA immobilized on a gold electrode to capture the aptamer, then the sensing interface was incubated with OTA at a desired concentration, followed by AuNPs–rGO functionalized reporter DNA hybridized with the residual aptamers. By exploiting the AuNPs–rGO as an excellent signal amplified platform, a single hybridization event between aptamer and reporter DNA was translated into more than 107 redox events, leading to a substantial increase in charge-transfer resistance (Rct) by 7∼ orders of magnitude compared with that of the free aptamer modified electrode. Such designed aptasensor showed a decreased response of Rct to the increase of OTA concentrations over a wide range of 1 pg mL−1–50 ng mL−1 and could detect extremely low OTA concentration, namely, 0.3 pg mL−1 or 0.74 pM, which was much lower than that of most other existed impedimetric aptasensors. The signal amplification platform presented here would provide a promising model for the aptamer-based detection with a direct impedimetric method.  相似文献   

4.
In this publication, a novel solid phase microextraction (SPME) coating functionalized with a DNA aptamer for selective enrichment of a low abundance protein from diluted human plasma is described. This approach is based on the covalent immobilization of an aptamer ligand on electrospun microfibers made with the hydrophilic polymer poly(acrylonitrile-co-maleic acid) (PANCMA) on stainless steel rods. A plasma protein, human α-thrombin, was employed as a model protein for selective extraction by the developed Apt-SPME probe, and the detection was carried out with liquid chromatography/tandem mass spectrometry (LC–MS/MS). The SPME probe exhibited highly selective capture, good binding capacity, high stability and good repeatability for the extraction of thrombin. The protein selective probe was employed for direct extraction of thrombin from 20-fold diluted human plasma samples without any other purification. The Apt-SPME method coupled with LC–MS/MS provided a good linear dynamic range of 0.5–50 nM in diluted human plasma with a good correlation coefficient (R2 = 0.9923), and the detection limit of the proposed method was found to be 0.30 nM. Finally, the Apt-SPME coupled with LC–MS/MS method was successfully utilized for the determination of thrombin in clinical human plasma samples. One shortcoming of the method is its reduced efficiency in undiluted human plasma compared to the standard solution. Nevertheless, this new aptamer affinity-based SPME probe opens up the possibility of selective enrichment of a given targeted protein from complex sample either in vivo or ex vivo.  相似文献   

5.
Camptothecin (CPT) and its derivative have been revealed to possess special anti-cancer activity, extraction methods are necessary for trace determination of CPTs in complex samples. In this work, we prepared a high efficient boronic acid-based polymer monolithic layer for microextraction of CPTs. A disposable membrane filter-based extraction device was developed, and boronic acid groups were co-polymerized into a polyporous polymer skeleton and served as the monolithic sorbent. The prepared poly(4-VB-MA-TRIM) showed good stability and great extraction efficiency toward four CPTs. After optimization of extraction conditions, poly(4-VB-MA-TRIM)-based solid-phase microextraction was coupled HPLC for determination of CPTs in biological samples. The method exhibited low limits of detection of 0.05–0.2 ng mL−1, which is significantly more sensitive than reported HPLC methods. The method also showed wide linear range (0.1–100 and 0.5–200 ng mL−1), good linearity (R2 ≥ 0.9981) and good reproducibility (RSD ≤3.76%). The method has been applied in plasma samples, with good selectivity and good recoveries ranging from 85.1 to 104.7%.  相似文献   

6.
We have developed and validated a sensitive method for the simultaneous determination of some monoamine neurotransmitters like dopamine (DA), norepinephrine (NE) and serotonin (5-HT) in rat brain microdialysate using high-performance liquid chromatography coupled to tandem mass spectrometry (LC/MS/MS). Sensitivity enhancement has been achieved by amine derivatization with the reagent (5-N-succinimidoxy-5-oxopentyl)triphenylphosphonium bromide (SPTPP) under mild conditions. The use of the selected reaction monitoring (SRM) mode has allowed detection of the analytes at a concentration of 30 pM (lower limit of quantification, LLOQ, signal-to-noise ratio higher than 5) with an accuracy of ≤3.80% and a precision of ±7.39 (%CV) for all neurotransmitters. Derivatization improves resolution and chromatographic retention times (3 min) by lipophilization. Linearity has been good (R > 0.99) over a large concentration range (30–50,000 pM). The intra and inter-batch accuracy and precision were not greater than 4.8% and 6.4%, respectively. Therefore, the method was successfully applied for monitoring the concentration changes of neurotransmitters in microdialysis samples deriving from striatum rat brain region after amphetamine administration (3 mg kg−1, i.p.).  相似文献   

7.
A selective and sensitive isotope dilution–high performance liquid chromatography–linear ion trap mass spectrometry (Isotope Dilution–HPLC–LIT-MS3) method was developed for the simultaneous determination of 19 triazine pesticides and their degradation products in processed cereal samples from Chinese total diet study (TDS). The method integrated the addition of isotope internal standards, liquid–liquid extraction (LLE), clean-up with MCX solid-phase extraction (SPE) cartridges and HPLC–LIT-MS3 analysis with selected reaction monitoring (SRM) mode. Matrix-matched calibration curves showed good linearity (R2 ≥ 0.9940) verified by applying the Mandel's fitting test (p > 0.087) performed at the 95% confidence level. Decision limits (CCαs) and detection capabilities (CCβs) of the 19 triazine pesticides and their degradation products fell in the ranges of 0.0020–0.4200 μg kg−1 and 0.0024–0.4500 μg kg−1, respectively. Recoveries ranged from 70.1% to 112.8%, with the relative standard deviations (RSDs) ranging from 1.5% to 13.5%. Furthermore, the proposed method was applied to analyzing the proposed cereal samples from the fourth Chinese TDS. Eleven triazines were detected in six cereal samples with the concentrations ranging from 0.013 to 0.987 μg kg−1. This method can also be used for the further determination of the triazines in other food group composites, and ultimately served as a methodological foundation for assessing the triazines in the average Chinese diet in the general population.  相似文献   

8.
We determine the association constants for ligand–protein complex formation using the flow injection method. We carry out the measurements at high flow rates (F = 1 mL min−1) of a carrier phase. Therefore, determination of the association constant takes only a few minutes. Injection of 1 nM of the ligand (10 μL of 1 μM concentration of the ligand solution) is sufficient for a single measurement. This method is tested and verified for a number of complexes of selected drugs (cefaclor, etodolac, sulindac) with albumin (BSA). We obtain K = 4.45 × 103 M−1 for cefaclor, K = 1.00 × 105 M−1 for etodolac and K = 1.03 × 105 M−1 for sulindac in agreement with the literature data. We also determine the association constants of 20 newly synthesized 3β- and 3α-aminotropane derivatives with potential antipsychotic activity – ligands of 5-HT1A, 5-HT2A and D2 receptors with the albumin. Results of the studies reported here indicate that potential antipsychotic drugs bind weakly to the transporter protein (BSA) with ≈ 102–103 M−1. Our method allows measuring K in a wide range of values (102–109 M−1). This range depends only on the solubility of the ligand and sensitivity of the detector.  相似文献   

9.
The application of comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometry (GC × GC-TOFMS) for the analysis of six anabolic agents (AAs) in doping control is investigated in this work. A non-polar–polar column configuration with 0.2 μm film thickness (df) second dimension (2D) column was employed, offering much better spread of the components on 2D when compared to the alternative 0.1 μm df2D column. The proposed method was tested on the “key” AA that the World Anti-Doping Agency (WADA) had listed at the low ng mL−1 levels (clenbuterol, 19-norandrosterone, epimethendiol, 17α-methyl-5α-androstane-3α,17β-diol, 17α-methyl-5β-androstane-3α,17β-diol and 3′-OH-stanozolol). The compounds were spiked in a blank urine extract obtained by solid-phase extraction, hydrolysis and liquid–liquid extraction; prior to analysis they were converted to the corresponding trimethylsilyl (TMS) derivatives. The limit of detection (LOD) was below or equal to the minimum required performance limit (MRPL) of 2 ng mL−1 defined by WADA, and the correlation coefficient was in the range from 0.995 to 0.999. The method allows choosing an ion from the full mass spectra which shows the least interference from the matrix and/or the best sensitivity; this can only be done if full scan mass spectral data are available. The advantage of GC × GC over classical one-dimensional GC (1D GC), in terms of separation efficiency and sensitivity, is demonstrated on a positive urine control sample at a concentration of 5 ng mL−1. The obtained similarity to the in-house created TOFMS spectra library at this level of concentration was in the range from 822 to 932 (on the scale from 0 to 999). Since full mass spectral information are recorded, the method allows the retro-search of non-target compounds or new “designer steroids”, which cannot be detected with established GC–MS methods that use selected ion monitoring (SIM) mode.  相似文献   

10.
Pueraria candollei associated preparation is widely applied in folk Thai medicine for rejuvenating purpose in aged people, which correlated with its pharmacological activities reported by pre-clinical and clinical trials. Therefore, standardized products of this plant are needed by consumers and health care personnel. Miroestrol, a potent and stable phytoestrogen in P. candollei, exhibited potential to be biomarker for quality control of P. candollei samples in research or industrial levels. Indirect competitive enzyme-linked immunosorbant assay (ELISA) for miroestrol determination was developed and validated by using polyclonal antibody from rabbit immunization. The polyclonal antibody recognized specifically to miroestrol, which exhibited cross-reactivity to deoxymiroestrol and isomiroestrol with 6.68% and 1.05%, respectively. The linearity range of measurement was 0.73–3000 ng mL−1, which coefficient of variation (CV) of both intra- and inter-plate determination was less than 5%. With spiked samples of known amount miroestrol, the percentages of recovery were 98.80–104.37% and 98.31–106.69% in P. candollei and its involved product samples, respectively. Validated ELISA was comparable with published HPLC method (R2 = 0.9996) (Yusakul et al. [18]) in samples with various miroestrol contents. For application, the P. candollei involved preparations contained miroestrol 0.695 ± 0.037–12.108 ± 0.285 μg g−1 dry wt. The developed ELISA was high performance for miroestrol determination, which could be applied for P. candollei quality control in research fields and industrial productions.  相似文献   

11.
We are just beginning to exploit the fascinating potential of thionine, called electrochemical probe that can selectively recognize specific polycyclic aromatic hydrocarbons (PAHs), as tools for the detection of tricyclic aromatic hydrocarbons phenanthrene (PHE) and anthracene (ANT). A novel electrochemical sensing platform by modification of electroactive thionine functionalized graphene onto glass carbon electrode (Th/GRs/GCE) surface was constructed. The immobilized thionine showed a remarkable stability, which may benefit from the π–π stacking force with graphene. Under optimum conditions, the proposed electrochemical sensor exhibited high sensitivity and low detection limit for detecting PHE and ANT. The total amount of PHE and ANT could be quantified in a wide range of 10 pM–0.1 μM with a good linearity (R2 = 0.9979) and a low detection limit of 0.1 pM (S/N = 3). Compounds which possess one or two benzene rings or PAHs with more than three rings, such as benzene, naphthalene (NAP), benzo[a]pyrene (BaP) and pyrene (PYR) show little interference on the detection. Consequently, a simple and sensitive electrochemical method was proposed for the determination of PHE and ANT, which was used to determine PHE and ANT in waste water samples. The electrochemical method provides a general tool that complements the commonly used spectroscopic methods and immune method for the detection of PAHs.  相似文献   

12.
Comprehensive two-dimensional gas chromatography coupled with time-of-flight mass spectrometry (GC × GC–TOFMS) is a well-established instrumental platform for complex samples. However, chemometric data analysis is often required to fully extract useful information from the data. We demonstrate that retention time shifting from one modulation to the next, Δ2tR, is not sufficient alone to quantitatively describe the trilinearity of a single GC × GC–TOFMS run for the purpose of predicting the performance of the chemometric method parallel factor analysis (PARAFAC). We hypothesize that analyte peak width on second dimension separations, 2Wb, also impacts trilinearity, along with Δ2tR. The term trilinearity deviation ratio, TDR, which is Δ2tR normalized by 2Wb, is introduced as a quantitative metric to assess accuracy for PARAFAC of a GC × GC–TOFMS data cube. We explore how modulation ratio, MR, modulation period, PM, temperature programming rate, Tramp, sampling phase (in-phase and out-of-phase), and signal-to-noise ratio, S/N, all play a role in PARAFAC performance in the context of TDR. Use of a PM in the 1–2 s range provides an optimized peak capacity for the first dimension separation (500–600) for a 30 min run, with an adequate peak capacity for the second dimension separation (12–15), concurrent with an optimized two-dimensional peak capacity (6000–7500), combined with sufficiently low TDR values (0–0.05) to facilitate low quantitative errors with PARAFAC (0–0.5%). In contrast, use of a PM in the 5 s or greater range provides a higher peak capacity on the second dimension (30–35), concurrent with a lower peak capacity on the first dimension (100–150) for a 30 min run, and a slightly reduced two-dimensional peak capacity (3000–4500), and furthermore, the data are not sufficiently trilinear for the more retained second dimension peaks in order to directly use PARAFAC with confidence.  相似文献   

13.
In this study we on-line coupled hollow fiber liquid–liquid–liquid microextraction (HF-LLLME), assisted by an ultrasonic probe, with high-performance liquid chromatography (HPLC). In this approach, the target analytes – 2-chlorophenol (2-CP), 3-chlorophenol (3-CP), 2,6-dichlorophenol (2,6-DCP), and 3,4-dichlorophenol (3,4-DCP) – were extracted into a hollow fiber (HF) supported liquid membrane (SLM) and then back-extracted into the acceptor solution in the lumen of the HF. Next, the acceptor solution was withdrawn on-line into the HPLC sample loop connected to the HF and then injected directly into the HPLC system for analysis. We found that the chlorophenols (CPs) could diffuse quickly through two sequential extraction interfaces – the donor phase – SLM and the SLM – acceptor phase – under the assistance of an ultrasonic probe. Ultrasonication provided effective mixing of the extracted boundary layers with the bulk of the sample and it increased the driving forces for mass transfer, thereby enhancing the extraction kinetics and leading to rapid enrichment of the target analytes. We studied the effects of various parameters on the extraction efficiency, viz. the nature of the SLM and acceptor phase, the compositions of the donor and acceptor phases, the fiber length, the stirring rate, the ion strength, the sample temperature, the sonication conditions, and the perfusion flow rate. This on-line extraction method exhibited linearity (r2 ≥ 0.998), sensitivity (limits of detection: 0.03–0.05 μg L−1), and precision (RSD% ≤ 4.8), allowing the sensitive, simple, and rapid determination of CPs in aqueous solutions and water samples with a sampling time of just 2 min.  相似文献   

14.
A novel ceria (CeO2)–ordered mesoporous carbon (OMC) modified electrode for the sensitive amperometric determination of hydrazine was reported. CeO2–OMC composites were synthesized via a hydrothermal method at a relatively low temperature (180 °C) and characterized by scanning electron microscopy (SEM), transmission electron microcopy (TEM), X-ray photoelectron spectroscopy (XPS) and X-ray diffraction (XRD). The CeO2–OMC modified glassy carbon electrode was characterized by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) and indicated good electrocatalytic effect to the oxidation of hydrazine. Under the optimized conditions, the present sensor could be used to measure hydrazine in wide linear range from 40 nM to 192 μM (R2 = 0.999) with a low detection limit of 12 nM (S/N = 3). Additionally, the sensor has been successfully applied to detect hydrazine in real water samples and the recoveries were between 98.2% and 105.6%. Eventually, the sensor exhibited an excellent stability and reproducibility as a promising method for determination of hydrazine.  相似文献   

15.
A novel glucose biosensor, based on the modification of well-aligned polypyrrole nanowires array (PPyNWA) with Pt nanoparticles (PtNPs) and subsequent surface adsorption of glucose oxidase (GOx), is described. The distinct differences in the electrochemical properties of PPyNWA–GOx, PPyNWA–PtNPs, and PPyNWA–PtNPs–GOx electrodes were revealed by cyclic voltammetry. In particular, the results obtained for PPyNWA–PtNPs–GOx biosensor showed evidence of direct electron transfer due mainly to modification with PtNPs. Optimum fabrication of the PPyNWA–PtNPs–GOx biosensor for both potentiometric and amperometric detection of glucose were achieved with 0.2 M pyrrole, applied current density of 0.1 mA cm−2, polymerization time of 600 s, cyclic deposition of PtNPs from −200 mV to 200 mV, scan rate of 50 mV s−1, and 20 cycles. A sensitivity of 40.5 mV/decade and a linear range of 10 μM to 1000 μM (R2 = 0.9936) were achieved for potentiometric detection, while for amperometric detection a sensitivity of 34.7 μA cm−2 mM−1 at an applied potential of 700 mV and a linear range of 0.1–9 mM (R2 = 0.9977) were achieved. In terms of achievable detection limit, potentiometric detection achieved 5.6 μM of glucose, while amperometric detection achieved 27.7 μM.  相似文献   

16.
In this study, an ultra-sensitive method for the quantification of lysozyme based on the Gd3+ diethylenetriamine-N,N,N′,N″,N″-pentaacetic acid labeling and capillary electrophoresis–inductively coupled plasma mass spectrometry (CE–ICP–MS) was described. The Gd3+-tagged lysozyme was effectively separated by capillary electrophoresis (CE) and sensitively determined by inductively coupled plasma mass spectrometry (ICP–MS). Based on the gadolinium-tagging and CE–ICP–MS, the lysozyme was determined within 12 min with an extremely low detection limit of 3.89 attomole (3.89 × 10−11 mol L−1 for 100 nL of sample injection) and a RSD < 6% (n = 5). The proposed method has been successfully used to detect lysozyme in saliva samples with a recovery of 91–106%, suggesting that our method is sensitive and reliable. The success of the present method provides a new potential for the biological assays and sensitive detection of low-abundant proteins.  相似文献   

17.
The routine method of paper chromatography includes five steps: spotting, separating, drying, spraying/immersing and color development. In this paper, a pre-staining paper chromatography which only consisted of spotting, separating and color development was developed for quantitative analysis of γ-aminobutyric acid. Compared to the routine paper chromatography, the improved method is clean, rapid, inexpensive and reproducible. The effects of ninhydrin concentration, color temperature, color time and Cu2+ concentration on the color yield in the ninhydrin reaction were optimized. And then the pre-staining paper chromatography coupled with vis spectrophotometry was applied to γ-aminobutyric acid quantification. The results indicated that the limit of detection was 0.05 mg mL−1 and the linear range was from 0.5 to 20.0 mg mL−1. Furthermore, an excellent correlation coefficient was observed with an R2 = 0.998. The method is accurate (RSD < 2.64%), and has good recoveries (102.7–103.9%). The validation of the modified technique was verified by a HPLC method.  相似文献   

18.
The study of pesticide residues belonging to endocrine disrupting chemicals (EDCs) (23 analytes of different chemical classes – organochlorines, organophosphates, pyrethroids, dicarboximides, phtalamides, dinitroanilines, pyrazole, triazinone) in apple matrix with conventional capillary GC–NCI-MS (with methane as reagent gas) in comparison to EI ionization is presented. For sample preparation QuEChERS method was applied. The lowest calibration levels (LCLs) for all pesticides were determined in both modes. Calibration in the NCI mode was performed at the concentration levels from 0.1 to 500 μg kg−1 (R2 > 0.999) and for EI in the range from 5 to 500 μg kg−1 (R2 > 0.99). From LCLs the instrumental limits of detection (LODs) and quantification (LOQs) were calculated. Chemometric study of pesticide signals in two MS modes was performed. Repeatability of all measurements, expressed by the relative standard deviations of absolute peak areas was better than 10% for the majority of compounds. Significantly lower values were obtained for the NCI mode.  相似文献   

19.
A simple sample preparation method was developed by using a centrifugal ultrafiltration (CF-UF) device with hollow fiber (HF) for the determination of cefaclor in plasma by HPLC. Samples were placed into a homemade device, which was consisted of a glass tube and a U-shaped hollow fiber. The filtrate was withdrawn from the hollow fiber into a syringe after centrifugation and 20 μL was directly injected into the HPLC for analysis. The HPLC method had a linear calibration curve in the concentration range of 6.00 × 10−2–30.7 μg mL−1(r = 0.9996). The limit of detection (LOD) and limit of quantitation (LOQ) were 0.02 and 0.06 μg mL−1, respectively. The intra and inter-day precisions (RSD) were 1.7%, 1.2%, 1.0% and 3.6%, 2.5%, 1.9%, respectively, for three concentrations. Assay accuracy was higher than 99.2% and the absolute recovery was 86.8–92.5%. It is feasible to use this novel and low cost device for sample pretreatment for the analysis of cefaclor in plasma.  相似文献   

20.
A gas chromatographic–positive chemical ionisation-tandem mass spectrometric (GC–PCI-MS/MS) method for the simultaneous determination of 10 oxidative metabolites of the monoterpenoid hydrocarbons α-pinene, (R)-limonene, and Δ3-carene ((+)-3-carene) in human urine was developed and tested for the monoterpene biomonitoring of the general population (n = 36). The method involves enzymatic cleavage of the glucuronides followed by solid-supported liquid–liquid extraction and derivatisation using a two-step reaction with N,O-bis(trimethylsilyl)-trifluoroacetamide and N-(trimethylsilyl)imidazole. The method proved to be both sensitive and reliable with detection limits ranging from 0.1 to 0.3 μg L−1. In contrast to the frequent and distinct quantities of (1S,2S,4R)-limonene-1,2-diol, the (1R,2R,4R)-stereoisomer could not be detected. The expected metabolite of (+)-3-carene, 3-caren-10-ol was not detected in any of the samples. All other metabolites were detected in almost all urine samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号