首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Wang AJ  Xu JJ  Zhang Q  Chen HY 《Talanta》2006,69(1):210-215
Poly(dimethylsiloxane) (PDMS) microfluidic channels modified by citrate-stabilized gold nanoparticles after coating a layer of linear polyethylenimine (LPEI) were successfully used to separate dopamine and epinephrine, which were difficult to be separated from baseline in native and hybrid PDMS microchannels. In-channel amperometric detection with a single carbon fibre cylindrical electrode was employed. Experimental parameters of separation and detection processes were optimized in detail. The analytes were well separated within 100 s in a 3.7 cm long separation channel at a separation voltage of +800 V using a 30 mM phosphate buffer solution (PBS, pH 7.0). Linear responses of them were obtained both from 25 to 600 μM with detection limits of 2 μM for dopamine and 5 μM for epinephrine, respectively. The modified PDMS channels have a long-term stability and an excellent reproducibility within 2 weeks.  相似文献   

2.
Xu C  Wang M  Yin X 《The Analyst》2011,136(19):3877-3883
A simple three-dimensional (3D) hydrodynamic focusing microfluidic device integrated with continuous sampling, rapid dynamic lysis, capillary electrophoretic (CE) separation and detection of intracellular content is presented. One of the major difficulties in microfluidic cell analysis for adherent cells is that the cells are prone to attaching to the channel surface. To solve this problem, a cross microfluidic chip with three sheath-flow channels located on both sides of and below the sampling channel was developed. With the three sheath flows around the sample solution-containing cells, the formed soft fluid wall prevents the cells from adhering to the channel surface. Labeled cells were 3D hydrodynamically focused by the sheath-flow streams and smoothly introduced into the cross-section one by one. The introduction of sheath-flow streams not only ensured single-cell sampling but avoided blockage of the sampling channel by adherent cells as well. The maximum rate for introduction of individual cells into the separation channel was about 151 cells min(-1). With electric field applied on the separation channel, the aligned cells were driven into the separation channel and rapidly lysed within 400 ms at the entry of the channel by sodium dodecylsulfate (SDS) added in the sheath-flow solution. The microfluidic system was evaluated by analysis of reduced glutathione (GSH) and reactive oxygen species (ROS) in single HepG2 cells. The average analysis throughput of ROS and GSH in single cells was 16-18 cells min(-1).  相似文献   

3.
We report a reliable strategy to perform automated image cytometry of single (non-adherent) stem cells captured in microfluidic traps. The method rapidly segments images of an entire microfluidic chip based on the detection of horizontal edges of microfluidic channels, from where the position of the trapped cells can be derived and the trapped cells identified with very high precision (>97%). We used this method to successfully quantify the efficiency and spatial distribution of single-cell loading of a microfluidic chip comprised of 2048 single-cell traps. Furthermore, cytometric analysis of trapped primary hematopoietic stem cells (HSC) faithfully recapitulated the distribution of cells in the G1 and S/G2-M phase of the cell cycle that was measured by flow cytometry. This approach should be applicable to automatically track single live cells in a wealth of microfluidic systems.  相似文献   

4.
The doxorubicin (DOX) uptake in single human leukemia K562 cells with changes in both drug dosage and exposure period was studied using capillary electrophoresis (CE) coupled with laser-induced fluorescence (LIF) detection. The cells were treated with DOX at different concentrations (1, 3, 10, 20, 30, and 50 μM) and for different exposure times (1, 3, 5, 24, and 48 h). At least 20 cells were analyzed for each DOX-treated cell population. A marked heterogeneity in DOX uptake among single cells was observed, because the relative standard deviation of the uptake of DOX by single cells ranged from 24.0% to 61.1% within each cell population. The cell-to-cell heterogeneity in DOX uptake first decreased and then became constant with increasing drug concentration, but it did not exhibit regular variation with increasing exposure time. The mean DOX uptake was a linear function of drug concentration (r ≥ 0.9667). In terms of the correlation with exposure time, the mean DOX uptake reached its maximum at 3 h for the cell populations treated with 1–10 μM DOX, while it kept increasing during 48 h exposure of cell populations to 20–50 μM DOX. Because it eliminates DOX fluorescence quenching and sample loss, the CE-LIF method directly detects the true DOX uptake by single cells, and thus presents accurate information on both the cell-to-cell heterogeneity in DOX uptake and the patterns of DOX uptake in K562 cells as functions of drug concentration and exposure time.  相似文献   

5.
A three-dimensional microchannel network with two-level crossings of channels was constructed in a glass microchip by sandwiching an insulating glass plate between two glass plates with microchannels followed by thermal bonding. Pressure-driven stable multi-phase laminar flows inside the three-dimensional channel network were realized by balancing flow rates of syringe pumps. Micro unit operations for mixing, reaction, solvent extraction, and detection were properly arranged in the multi-phase laminar flows, so that four parallel analyses, comprising twenty unit operations in total, could be integrated onto a single chip. Two chelating reagents and two sample solutions containing heavy metal ions (Fe(ii) or Co(ii)) were mixed and reacted in four different combinations using the three-dimensional channel network. After chelating reactions were completed, post processing (solvent extraction or addition of acid) was applied to each solution stream to remove the interferences of coexisting metal ions. Finally, target metal complexes were detected using a thermal lens microscope (TLM). Integrity of the micro system was confirmed by qualitative analysis of Fe(ii) and Co(ii). This is the first example of continuous flow chemical processing utilizing multi-phase laminar flow realized in a three-dimensional channel network.  相似文献   

6.
微流控芯片操纵传输及实时监测单细胞量子释放   总被引:2,自引:0,他引:2  
微流控芯片技术用于细胞生化分析已引起了广泛关注.Harrison等首次在微流控芯片上对细胞群体进行操纵、传输及反应.yang等在微流控芯片上操纵细胞群体的排列,并用荧光检测细胞群体摄取钙的反应.至今还未见到微流控芯片对单个细胞进行操纵传输、定位及实时监测的报道.单细胞受激释放的监测对探索生物体神经传导具有重要意义.  相似文献   

7.
DNA analysis with the polymerase chain reaction (PCR) has become a routine part of medical diagnostics, environmental inspections, food evaluations, and biological studies. Furthermore, the development of a microscale PCR chip is an essential component of studies aimed at integrating PCR into a micro total analysis system (μ-TAS). However, the occurrence of air bubbles in microchannels complicates this process. In this study, we investigated a new technique based on the fluid dynamics of laminar flow that utilizes a small amount of mineral oil at the beginning of sample injection to prevent air bubbles from occurring in microchannels. We also further optimized the pressure, the length of the pressurizing channel and the volume of oil, thus making our microfluidic device more useful for high-temperature PCR. Additionally, quantitative continuous-flow PCR was performed using the optimized PCR chip in order to detect genetically modified (GM) maize. DNA was extracted from GM maize, MON 810, and non-GM maize at several concentrations from 0% (w/v) to 100% (w/v). The DNA amplification signals were then analyzed on the PCR chip using a laser-based system. The signal from our microfluidic PCR chip was found to increase in direct proportion to the initial GM maize concentration.  相似文献   

8.
Microfluidic device for capillary electrochromatography-mass spectrometry   总被引:2,自引:0,他引:2  
Lazar IM  Li L  Yang Y  Karger BL 《Electrophoresis》2003,24(21):3655-3662
A novel microfabricated device that integrates a monolithic polymeric separation channel, an injector, and an interface for electrospray ionization-mass spectrometry detection (ESI-MS) was devised. Microfluidic propulsion was accomplished using electrically driven fluid flows. The methacrylate-based monolithic separation medium was prepared by photopolymerization and had a positively derivatized surface to ensure electroosmotic flow (EOF) generation for separation of analytes in a capillary electrochromatography (CEC) format. The injector operation was optimized to perform under conditions of nonuniform EOF within the microfluidic channels. The ESI interface allowed hours of stable operation at the flow rates generated by the monolithic column. The dimensions of one processing line were sufficiently small to enable the integration of 4-8 channel multiplexed structures on a single substrate. Standard protein digests were utilized to evaluate the performance of this microfluidic chip. Low- or sub-fmol amounts were injected and detected with this arrangement.  相似文献   

9.
单细胞分析的研究   总被引:1,自引:0,他引:1  
程介克  黄卫华  王宗礼 《色谱》2007,25(1):1-10
单细胞分析是分析化学、生物学和医学之间渗透发展形成的跨学科前沿领域。近年来,毛细管电泳及微流控芯片用于单细胞分析已取得显著进展,特别表现在微流控芯片用于细胞的培养、分选、操纵、定位、分离及检测细胞的组分,实时监测细胞释放,及高通量阵列检测等方面。芯片的单元操作可根据需要灵活组合,显示出其独特的优点。本文重点介绍作者研究组的工作,并对近三年来国内外在毛细管电泳及芯片毛细管电泳用于单细胞分析的新进展进行评论。最后从毛细管电泳与微流控芯片、微流控芯片与细胞界面以及量子点用于探测活细胞等方面,展望了单细胞分析的发展前景。  相似文献   

10.
Yang S  Liu J  DeVoe DL 《Lab on a chip》2008,8(7):1145-1152
Multidimensional microfluidic separation systems combining a first dimension microchannel with an array of parallel second dimension microchannels can suffer from non-uniform sample transfer between the dimensions, sample leakage, and injection plug tailing within the second dimension array. These factors can significantly reduce overall two-dimensional separation performance. In this paper, numerical and analytical models reveal an optimized chip design which combines multidimensional backbiasing and an angled channel geometry to ensure leakage-free and uniform interdimensional sample transfer, while also minimizing injected sample plug lengths. The optimized design is validated experimentally using a multidimensional chip containing five second dimension channels.  相似文献   

11.
设计并验证了一种用于细胞三维培养的集成微柱阵列的微流控芯片.芯片由一片聚二甲基硅氧烷(PDMS)沟道片和一片玻璃盖片组成, 在PDMS沟道片上集成了一个由两排微柱阵列围成的细胞培养室和两条用于输送培养基的侧沟道.微柱间距直接影响了芯片的使用性能, 是整个芯片设计的关键.基于数值模拟和实验验证, 本研究对微柱间距进行了优化设计.优化后的微流控芯片可以很好地实现细胞与细胞外基质模拟材料混合液的稳定注入、培养基中营养物质向培养室内的快速扩散和细胞代谢物的及时排出.在芯片上进行了神经干细胞的三维培养, 证明了芯片上构建的细胞体外微环境的稳定性.  相似文献   

12.
A novel multi-channel poly(methyl methacrylate) (PMMA) microfluidic biosensor with interdigitated ultramicroelectrode arrays (IDUAs) for electrochemical detection was developed. The focus of the development was a simple fabrication procedure and the realization of a reliable large IDUA that can provide detection simultaneously to several microchannels. As proof of concept, five microchannels are positioned over a large single IDUA where the channels are parallel with the length of the electrode finger. The IDUAs were fabricated on the PMMA cover piece and bonded to a PMMA substrate containing the microfluidic channels using UV/ozone-assisted thermal bonding. Conditions of device fabrication were optimized realizing a rugged large IDUA within a bonded PMMA device. Gold adhesion to the PMMA, protective coatings, and pressure during bonding were optimized. Its electrochemical performance was studied using amperometric detection of potassium ferri and ferro hexacyanide. Cumulative signals within the same chip showed very good linearity over a range of 0–38 μM (R 2?=?0.98) and a limit of detection of 3.48 μM. The bonding of the device was optimized so that no cross talk between the channels was observed which otherwise would have resulted in unreliable electrochemical responses. The highly reproducible signals achieved were comparable to those obtained with separate single-channel devices. Subsequently, the multi-channel microfluidic chip was applied to a model bioanalytical detection strategy, i.e., the quantification of specific nucleic acid sequences using a sandwich approach. Here, probe-coated paramagnetic beads and probe-tagged liposomes entrapping ferri/ferro hexacyanide as the redox marker were used to bind to a single-stranded DNA sequence. Flow rates of the non-ionic detergent n-octyl-β-d-glucopyranoside for liposome lysis were optimized, and the detection of the target sequences was carried out coulometrically within 250 s and with a limit of detection of 12.5 μM. The robustness of the design and the reliability of the results obtained in comparison to previously published single-channel designs suggest that the multi-channel device offers an excellent opportunity for bioanalytical applications that require multianalyte detection and high-throughput assays.
Figure
Multi-channel microfluidic biosensor with integrated IDUAs for a sandwich nucleic acid hybridization assay  相似文献   

13.
The measurement of single poly(ethylene glycol) (PEG) molecules interacting with individual bilayer lipid membrane-bound ion channels is presented. Measurements were performed within a polymer microfluidic system including an open-well bilayer lipid membrane formation site, integrated Ag/AgCl reference electrodes for on-chip electrical measurements, and multiple microchannels for independent ion channel and analyte delivery. Details of chip fabrication, bilayer membrane formation, and alpha-hemolysin ion channel incorporation are discussed, and measurements of interactions between the membrane-bound ion channels and single PEG molecules are presented.  相似文献   

14.
A chip-based microfluidic system for high-throughput single-cell analysis is described. The system was integrated with continuous introduction of individual cells, rapid dynamic lysis, capillary electrophoretic (CE) separation and laser induced fluorescence (LIF) detection. A cross microfluidic chip with one sheath-flow channel located on each side of the sampling channel was designed. The labeled cells were hydrodynamically focused by sheath-flow streams and sequentially introduced into the cross section of the microchip under hydrostatic pressure generated by adjusting liquid levels in the reservoirs. Combined with the electric field applied on the separation channel, the aligned cells were driven into the separation channel and rapidly lysed within 33ms at the entry of the separation channel by Triton X-100 added in the sheath-flow solution. The maximum rate for introducing individual cells into the separation channel was about 150cells/min. The introduction of sheath-flow streams also significantly reduced the concentration of phosphate-buffered saline (PBS) injected into the separation channel along with single cells, thus reducing Joule heating during electrophoretic separation. The performance of this microfluidic system was evaluated by analysis of reduced glutathione (GSH) and reactive oxygen species (ROS) in single erythrocytes. A throughput of 38cells/min was obtained. The proposed method is simple and robust for high-throughput single-cell analysis, allowing for analysis of cell population with considerable size to generate results with statistical significance.  相似文献   

15.
Applicability of polydimethylsiloxane (PDMS) for easy and rapid fabrication of enzyme sensor chips, based on electrochemical detection, is examined. The sensor chip consists of PDMS substrate with a microfluidic channel fabricated in it, and a glass substrate with enzyme-modified microelectrodes. The two substrates are clamped together between plastic plates. The sensor chip has shown no leakage around the microelectrodes under continuous solution flow (34 μl/min). Amperometric response of the sensor chips developed in this work suggest that various types of enzyme sensors can be designed by using PDMS microfluidic channels.  相似文献   

16.
Analysis of droplet contents is a key function involved in droplet-based microfluidic systems. Direct electrochemical detection of droplet contents suffers problems such as relatively poor repeatability, interference of capacitive current and relatively poor detectability. This paper presents a novel hybrid polydimethylsiloxane-glass chip for highly sensitive and reproducible amperometric detection of droplet contents. By wettability-patterning of the channel surface of the hybrid chip, water in oil droplets generated in the upstream part of the central channel can be switched to a two-phase vertical laminar flow (i.e., a continuous oil stream flowing atop a continuous aqueous stream) in the downstream part of the channel. The vertical laminar flow keeps the analyte in the underneath-flowing aqueous stream in direct contact with the sensing electrodes located on the bottom surface of the channel. Therefore, steady-state current signals with high sensitivity (1.2 A M−1 cm−2 for H2O2), low limit of detection (0.12 μM, S/N = 2), and good reproducibility (RSD 1.1% at 0.3 mM H2O2) were obtained. The methods for patterning of the inner channel surface are presented, and the behaviors of the microchip in flow profile switching and amperometric detection are discussed. The application of the developed microchip to enzyme kinetics study is also demonstrated.  相似文献   

17.
This paper characterizes the conditions required to form nanoliter-sized droplets (plugs) of viscous aqueous reagents in flows of immiscible carrier fluid within microfluidic channels. For both non-viscous (viscosity of 2.0 mPa s) and viscous (viscosity of 18 mPa s) aqueous solutions, plugs formed reliably in a flow of water-immiscible carrier fluid for Capillary number less than 0.01, although plugs were able to form at higher Capillary numbers at lower ratios of the aqueous phase flow rate to the flow rate of the carrier fluid (in all the experiments performed, the Reynolds number was less than 1). The paper also shows that combining viscous and non-viscous reagents can enhance mixing in droplets moving through straight microchannels by providing a nearly ideal initial distribution of reagents within each droplet. The study should facilitate the use of this droplet-based microfluidic platform for investigation of protein crystallization, kinetics, and assays.  相似文献   

18.
This paper describes a micro flow cytometer system designed for efficient and non-damaging analysis of samples with small numbers of precious cells. The system utilizes actuation of Braille-display pins for micro-scale fluid manipulation and a fluorescence microscope with a CCD camera for optical detection. The microfluidic chip is fully disposable and is composed of a polydimethylsiloxane (PDMS) slab with microchannel features sealed against a thin deformable PDMS membrane. The channels are designed with diffusers to alleviate pulsatile flow behaviors inherent in pin actuator-based peristaltic pumping schemes to maximize hydrodynamic focusing of samples with minimal disturbances in the laminar streams within the channel. A funnel connected to the microfluidic channel is designed for efficient loading of samples with small number of cells and is also positioned on the chip to prevent physical damages of the samples by the squeezing actions of Braille pins during actuation. The sample loading scheme was characterized by both computational fluidic dynamics (CFD) simulation and experimental observation. A fluorescein solution was first used for flow field investigation, followed by use of fluorescence beads with known relative intensities for optical detection performance calibration. Murine myoblast cells (C2C12) were exploited to investigate cell viability for the sample loading scheme of the device. Furthermore, human promyelocytic leukemia (HL60) cells stained by hypotonic DNA staining buffer were also tested in the system for cell cycle analysis. The ability to efficiently analyze cellular samples where the number of cells is small was demonstrated by analyzing cells from a single embryoid body derived from mouse embryonic stem cells. Consequently, the designed microfluidic device reported in this paper is promising for easy-to-use, small sample size flow cytometric analysis, and has potential to be further integrated with other Braille display-based microfluidic devices to facilitate a multi-functional lab-on-a-chip for mammalian cell manipulations.  相似文献   

19.
General solutions are developed for direct current (DC) and alternating current (AC) electroosmotic flows in microfluidic channels with arbitrary cross-sectional geometry and arbitrary distribution of wall charge (zeta potential). The applied AC electric field can also be of arbitrary waveform. By proposing a nondimensional time scale varpi defined as the ratio of the diffusion time of momentum across the electric double-layer thickness to the period of the applied electric field, we demonstrate analytically that the Helmholtz-Smoluchowski electroosmotic velocity is an appropriate slip condition for AC electroosmotic flows in typical microfluidic applications. With this slip condition approach, electroosmotic flows in rectangular and asymmetric trapezoidal microchannels with nonuniform wall charge, as examples, are investigated. The unknown constants in the proposed general solutions are numerically determined with a least-squares method through matching the boundary conditions. We find that the wall charge affects significantly the electroosmotic flow while the channel geometry does not. Moreover, the flow feature is characterized by another nondimensional time scale Omega defined as the ratio of the diffusion time of momentum across the channel hydraulic radius to the period of the applied electric field. The onset of phase shift between AC electroosmotic velocity and applied electric field is also examined analytically.  相似文献   

20.
Zhu X  Yi Chu L  Chueh BH  Shen M  Hazarika B  Phadke N  Takayama S 《The Analyst》2004,129(11):1026-1031
This paper describes the use of arrays of horizontally-oriented reservoirs to deliver liquids through microchannels at a constant flow rate over extended periods of time (hours to days). The horizontal orientation maintains a constant hydraulic pressure drop across microfluidic channels even as the volumes of liquids within the reservoirs change over time. For a given channel-reservoir system, the magnitude of the flow velocity depends linearly on the height difference between reservoirs. The simple structure and operation mechanism make this pumping system versatile. A one-inlet-one-outlet system was used to continuously deliver media for perfusion cell culture, and an array of inlet reservoirs coupled to an outlet reservoir via microchannels was used to drive flows of multiple laminar streams. The parallel pumping scheme conveniently generated various smooth and step concentration gradients, and allowed evaluation of the effect of colchicine on myoblasts. Since the reservoir arrays are configured to be compatible with commercialized multichannel pipettors designed for 96 well plate handling, this simple pumping scheme is envisioned to be broadly useful for medium to high throughput microfluidic perfusion cell culture assays, cell migration assays, multiple laminar flow drug tests, and any other applications needing multiple microfluidic streams.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号