首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This paper reports the assessment of the total mercury (T-Hg) and methylmercury (MeHg) contamination of mussel samples collected by two sampling campaigns from along the coastline of Sardinia (Italy). T-Hg has been determined by a direct mercury analyser (DMA) whereas MeHg has been determined by gas chromatography-mass spectrometry (GC-MS) after acid extraction, and employs a novel NaBPh4 derivatization method. The evaluation of the quality of measurements was carried out by analysing candidate certified reference material (CRM) BCR 710, for MeHg and T-Hg, and CRM IAEA-350 for T-Hg. In the analysed samples, the T-Hg concentrations range from 35 to 115 μg kg−1 and from 40 to 830 μg kg−1, for the two sampling campaigns, respectively, whereas the MeHg concentrations range from l5 to 51 μg kg−1 and from 17 to 116 μg kg−1. Consequently, the MeHg/T-Hg ratios range from 0.33 to 0.91 and from 0.14 to 0.98, respectively. Despite the increasing trend of Hg concentration from the first to the second sampling campaign, the T-Hg concentration of all the samples was much below the 0.5 μg g−1 WHO limit, and the MeHg values ranged between 2.2 and 17.2 μg kg−1, not exceeding the 43.5 μg kg−1 tolerable daily residue level calculated for Italy.  相似文献   

2.
Linear alkylbenzene sulphonates (LAS) and polycyclic aromatics hydrocarbons (PAH) are organic pollutants in sewage sludge which will have to be monitored in the European Union according to the third draft of a future sludge directive. In the present work, an analytical method for the simultaneous extraction of 4 LAS homologues and 16 PAH congeners in sludge from wastewater treatment plants is proposed to improve the routine analysis of these compounds in sludge samples. The method involves sonication assisted extraction, clean-up and preconcentration by solid phase extraction, and determination by high-performance liquid chromatography with ultraviolet diode array (UV-DAD) and fluorescence (FLD) detectors. Average recoveries were 87% for LAS and 76% for PAH, with relative standard deviations below 13%. Limits of quantification of LAS and PAH were in the range from 13 to 56 mg kg−1 and from 80 to 650 μg kg−1, respectively, when using UV-DAD. Limits of quantification of LAS and PAH were in the range 5-18 mg kg−1 and from 1 to 150 μg kg−1, respectively, when using FLD. The applicability of the proposed method was evaluated by the determination of these compounds in sludge from wastewater treatment plants in Seville (South Spain).  相似文献   

3.
A supramolecular solvent consisting of vesicles, made up of equimolecular amounts of decanoic acid (DeA) and tetrabutylammonium decanoate (Bu4NDe), dispersed in a continuous aqueous phase, is proposed for the extraction of benzimidazolic fungicides (BFs) from fruits and vegetables. Carbendazim (CB), thiabendazole (TB) and fuberidazole (FB) were extracted in a single step and no clean-up or concentration of extracts was needed. The high extraction efficiency obtained for BFs was a result of the different types of interactions provided by the supramolecular solvent (e.g. hydrophobic and hydrogen bonds) and the high number of solubilisation sites it contains. Besides simple and efficient, the proposed extraction approach was rapid, low-cost, environment friendly and it was implemented using conventional lab equipments. The target analytes were determined in the supramolecular extract by LC/fluorescence detection. They were separated in a Kromasil C18 (5 μm, 150 mm × 4.6 mm) column using isocratic elution [mobile phase: 60:40 (v/v) 50 mM phosphate buffer (pH 4)/methanol] and quantified at 286/320 nm (CB) and 300/350 nm (TB and FB) excitation/emission wavelengths, respectively. Quantitation limits provided by the supramolecular solvent-based microextraction (SUSME)/LC/fluorescence detection proposed method for the determination of CB, TB and FB in fruits and vegetables were 14.0, 1.3 and 0.03 μg kg−1, respectively, values far below the current maximum residue levels (MRLs) established by the European Union, i.e. 100-2000 μg kg−1 for CB, 50-5000 μg kg−1 for TB and 50 μg kg−1 for FB. The precision of the method, expressed as relative standard deviation, for inter-day measurements (n = 13) was 3.3% for CB (50 μg kg−1), 3.5% for TB (10 μg kg−1) and 2.8% for FB (0.5 μg kg−1) and recoveries for fruits (oranges, tangerines, lemons, limes, grapefruits, apples, pears and bananas) and vegetables (potatoes and lettuces) fortified at the μg kg−1 level were in the interval 93-102%.  相似文献   

4.
An analytical method using solvent extraction and quantitative proton nuclear magnetic resonance (qHNMR) spectroscopy was applied and validated for the absolute quantification of sorbic acid (SA) in processed foods. The proposed method showed good linearity. The recoveries for samples spiked at the maximum usage level specified for food in Japan and at 0.13 g kg−1 (beverage: 0.013 g kg−1) were larger than 80%, whereas those for samples spiked at 0.063 g kg−1 (beverage: 0.0063 g kg−1) were between 56.9 and 83.5%. The limit of quantification was 0.063 g kg−1 for foods (and 0.0063 g kg−1 for beverages containing Lactobacillus species). Analysis of the SA content of commercial processed foods revealed quantities equal to or greater than those measured using conventional steam-distillation extraction and high-performance liquid chromatography quantification. The proposed method was rapid, simple, accurate, and precise, and provided International System of Units traceability without the need for authentic analyte standards. It could therefore be used as an alternative to the quantification of SA in processed foods using conventional method.  相似文献   

5.
《Analytica chimica acta》2004,513(1):41-47
A method for determination of ochratoxin A (OTA) in wine grapes is described, using extraction with a hydrogen carbonate and polyethylene glycol (PEG) solution (5% NaHCO3 and 1% PEG 8000), followed by immunoaffinity clean-up and liquid chromatography with fluorescence detection. Validation was made with spiked samples, in levels of 0.05 and 1 μg kg−1, with average recovery rates of 76% and relative standard deviations in repeatability and intermediate precision conditions of 8 and 12%, respectively. The limit of detection and limit of quantification in grapes were established at 0.004 and 0.007 μg kg−1, respectively. To evaluate further the accuracy and efficiency of this method, naturally contaminated grapes were also analysed by another method that involves extraction with acidified methanol, at levels ranging from 0.05 to 37 μg kg−1, and the results compared. A good correlation (r=0.9996) was found, with better performances in terms of precision for the new method. A survey was conducted on wine grapes from 11 Portuguese vineyards, during the harvest of 2002, using the proposed method. OTA was detected in three out of the 11 samples, at levels ranging from 0.035 to 0.061 μg kg−1.The new method meets all the criteria of the European Commission directive 2002/26/CE, that lays down the sampling and the analysis methods for the official control of OTA levels in foodstuffs. It is reliable for low levels of contamination (ng kg−1), and avoids the use of organic solvents in the extraction step.  相似文献   

6.
Di-(2-ethyl-hexyl)phthalate (DEHP), nonylphenol, nonylphenol mono- and diethoxylates (NPEs) and polychlorinated biphenyls (PCBs) are organic pollutants in sewage sludge which have to be monitored in the European Union according to a future Sludge Directive. In the present work, an analytical method for the simultaneous extraction and determination of DEHP, NPEs and PCBs is proposed for the routine analysis of these compounds in sludge from wastewater treatment plants. All the compounds were simultaneously extracted by sonication with hexane and analysed by gas chromatography-mass spectrometry (GC-MS) in electronic impact mode. Recoveries achieved were 105% for DEHP, 61.4-88.6% for NPEs and 55.8-108.3% for PCBs with relative standard deviation bellow 10%. Limits of quantification were 65 μg kg−1 for DEHP, from 630 to 2504 μg kg−1 for NPEs and from 5.4 to 10.6 μg kg−1 for PCBs in dried sludge. The applicability of the proposed method was evaluated by the determination of these compounds in sludge from wastewater treatment plants in Seville (South Spain).  相似文献   

7.
Jihai Zhou 《Talanta》2009,79(2):189-1249
A CPE-HPLC (UV) method has been developed for the determination of Prometryne. In this method, non-ionic surfactant Triton X-114 was first used to extract and pre-concentrate Prometryne from water and soil samples. The separation and determination of Prometryne were then carried out in an HPLC-UV system with isocratic elution using a detector set at 254 nm wavelength. The parameters and variables that affected the extraction were also investigated and the optimal conditions were found to be 0.5% of Triton X-114 (w/v), 3% of NaCl (w/v) and heat-assisted at 50 °C for 30 min. Using these conditions, the recovery rates of Prometryne ranged from 92.84% to 99.23% in water and 85.48% to 93.67% in soil, respectively, with all the relative standard deviations less than 3.05%. Limit of detection (LOD) and limit of quantification (LOQ) were 3.5 μg L−1 and 11.0 μg L−1 in water and 4.0 μg kg−1 and 13.0 μg kg−1 in soil, respectively. Thus, we developed a method that has proven to be an efficient, green, rapid and inexpensive approach for extraction and determination of Prometryne from soil samples.  相似文献   

8.
An improved LC-MS/MS method for the determination of semicarbazide in whole egg is described. Waters OASIS-MCX cation exchange purification cartridges increased the sensitivity for analysis by LC-MS/MS. The validation study was carried out according to criteria and requirements of Commission Decision 2002/657/EC for confirmatory analysis and provided the data as follows: The correlation coefficient for the matrix calibration curve, in the range of 0–5 μg kg−1, was r = 0.9968. The detection capability and decision limit, measured according to ISO11843-2, were CCα = 0.20 μg kg−1 and CCβ = 0.25 μg kg−1. Repeatability (CVSr) and within-laboratory reproducibility (CVSwr) determined for the concentration levels of 0.2, 0.5 and 1.0 μg kg−1 SEM ranged from 11.9 to 5.7% and 11.8 to 6.3%, respectively. The validated method was applied to investigate SEM stability in incurred materials (egg homogenates) during long-term storage at −20 °C and 4 °C. The study proved by a two-sampling test that SEM at levels of 17. 7, 1.2, 10.6 and 0.47 μg kg−1 was stable for up to 12 months.  相似文献   

9.
A multi-residue method for the determination of organochlorine pesticides in fish feed samples was developed and optimized. The method is based on a cleanup step of the extracted fat, carried out by liquid–liquid extraction on diatomaceous earth cartridge with n-hexane/acetonitrile (80/20, v/v) followed by solid phase extraction (SPE) with silica gel–SCX cartridge, before the identification and quantification of the residues by gas chromatography–triple quadrupole tandem spectrometry (GC–MS/MS). Performance characteristics, such as accuracy, precision, linear range, limits of detection (LOD) and quantification (LOQ), for each pesticide were determined. Instrumental LODs ranged from 0.01 to 0.11 μg L−1, LOQs were in the range of 0.02–0.35 μg L−1, and calibration curves were linear (r2 > 0.999) in the whole range of explored concentrations (5–100 μg L−1). Repeatability values were in the range of 3–15%, evaluated from the relative standard deviation of six samples spiked at 100 μg kg−1 of fat, and in compliance with that derived by the Horwitz's equation. No matrix effects or interfering substances were observed in fish feed analyses. The proposed method allowed high recoveries (92–116%) of spiked extracted fat samples at 100 μg kg−1, and very low LODs (between 0.02 and 0.63 μg kg−1) and LOQs (between 0.05 and 2.09 μg kg−1) determined in fish feed samples.  相似文献   

10.
Dispersive liquid-liquid microextraction (DLLME) coupled with high-performance liquid chromatography-variable wavelength detector (HPLC-VWD) was developed for extraction and determination of chloramphenicol (CAP) and thiamphenicol (THA) in honey. In this extraction method, 1.0 mL of acetonitrile (as dispersive solvent) containing 30 μL 1,1,2,2-tetrachloroethane (as extraction solution) was rapidly injected by syringe into a 5.00-mL water sample containing the analytes, thereby forming a cloudy solution. After extraction, phase separation was performed by centrifugation and the enriched analytes in the sedimented phase were determined by HPLC-VWD. Some important parameters, such as the nature and volume of extraction solvent and dispersive solvent, extraction time, sample solution pH, sample volume and salt effect were investigated and optimized. Under the optimum extraction condition, the method yields a linear calibration curve in the concentration range from 3 to 2000 μg kg−1 for target analytes. The enrichment factors for CAP and THA were 68.2 and 87.9, and the limits of detection (S/N = 3) were 0.6 and 0.1 μg kg−1, respectively. The relative standard deviations (RSDs) for the extraction of 10 μg kg−1 of CAP and THA were 4.3% and 6.2% (n = 6). The main advantages of DLLME-HPLC method are simplicity of operation, rapidity, low cost, high enrichment factor, high recovery, good repeatability and extraction solvent volume at microliter level. Honey samples were successfully analyzed using the proposed method.  相似文献   

11.
《Analytica chimica acta》2004,515(1):55-63
Clenbuterol has been extracted by mixed solid-phase extraction from two biological matrices (bovine hair and urine) and detected by GC/MS (selected ion monitoring (SIM) and full-SCAN modes). The analytical signal has been modelled with univariate and three-way models, namely DTLD, PARAFAC, PARAFAC2, Tucker3 and trilinear PLS. Since clenbuterol is a banned substance a comparative study of the capability of detection (CCβ, X0=0) has been performed as a function of the sample (hair, 74 μg kg−1 and urine, 0.36 μg l−1), the mode in which the signals are monitored (SCAN, 283 μg kg−1 and SIM, 74 μg kg−1) and the statistical model (univariate, 283 μg kg−1 and trilinear PLS, 20.91 μg kg−1). The capability of detection has been calculated as stated in ISO 11843 and Decision 2002/657/EC setting in all cases the probabilities of false positive and of false negative at 0.05.The identification of the mass spectra must be done to confirm the presence of clenbuterol and has been carried out through PARAFAC. The correlation coefficient between the spectra estimated by PARAFAC and the library spectra is 0.96 (hair, SCAN mode) and 1.00 (hair and urine, SIM mode).The Decision 2002/657/EC advocates the use of independent mass fragments to identify banned compounds. These recommendations together with the effect of the number of ions registered on the capability of detection have lead us to select five uncorrelated fragments (86, 243, 262, 264 and 277) from the data set of 210 ions by hierarchical clustering of variables.  相似文献   

12.
A procedure involving the simultaneous performance of liquid–liquid microextraction and polypropylene microporous membrane solid-phase extraction was carried out. The applicability of the proposed procedure was evaluated through extraction of several organochlorine pesticides from river water, tomato and strawberry samples. The parameters affecting the extraction efficiency were optimized by multivariable designs, and the analytical features were estimated. Under optimized conditions, analytes were concentrated onto 1.5 cm long microporous membranes placed directly into the sample containing 15 mL of water with 20 μL of 1-octanol. The best extraction conditions were achieved at 59 °C, with 60 min of extraction time and 2.91 g of sodium chloride. The desorption of the analytes was carried out using 30 μL of a mixture of toluene and hexane in the proportion of 60:40% (v/v) for 10 min. Detection limits in the range of 2.7–20.0 ng L−1, 0.50–1.15 μg kg−1, and 1.53–12.77 μg kg−1 were obtained for river water, strawberry and tomato samples, respectively. Good repeatability was obtained for all three sample types. The results suggest that the proposed procedure represents a very simple and low-cost microextraction alternative rendering adequate limits of quantification for the determination of organochlorine pesticides in environmental and food samples.  相似文献   

13.
A capillary zone electrophoresis method with UV detection was developed for the simultaneous detection and quantification of three tetracyclines in chicken meat samples: tetracycline (TC), oxytetracycline (OTC) and doxycycline (DOC). The separation conditions were: a running buffer containing 30 mM sodium phosphate, 2 mM EDTA disodium salt and 2.5% 2-propanol, pH 12.0, a 5 s hydrodynamic injection and a 14 kV separation voltage. Two different clean-up methodologies were employed: solid-phase extraction with C18 cartridges and ion exchange with Amberlite XAD7 resin. Analytes were detected at 360 nm in less than 12 min. LODs ranged from 61 μg kg−1 for OTC to 68 μg kg−1 for DOC with C18 cartridges, and 81 μg kg−1 for DOC to 89 μg kg−1 for TC with Amberlite XAD7 resin. The recoveries for TC, OTC and DOC obtained by both methods were between 85 and 95%, and the peak area repeatability for all of the samples was below 5% in all cases. Twenty-four samples of commercial chicken drumsticks were examined with both clean-up methodologies. In nine cases (37.5%) TC was detected, in a range from 197.8 to 2564.3 μg kg−1, and in seven cases (29.2%) OTC was detected in a range from 83.0 to 2049.3 μg kg−1. DOC was not detected in any of the tested samples. This method would be useful for the routine monitoring of TCs residues in poultry muscle.  相似文献   

14.
The study proposes an analytical method to quantify 10 alkylphenols and 12 pesticides at ultra-trace levels by liquid chromatography in reverse mode coupled to positive electrospray ionisation–tandem mass spectrometry. The extraction procedure from environmental solids was optimised by pressurised liquid extraction using acetonitrile:isopropanol (1:1, v/v). The influence of several extraction experimental factors, temperature, pressure, duration and number of cycles, related to the PLE was investigated by an original and efficient chemometric approach. The optimised extraction method (80 °C, 40 bar, 10 min, 1 cycle) exhibited recoveries between 67 and 127% with RSD mostly under 13%. The whole method was applied to real samples: sludge, suspended materials, atmospheric fallouts and roof deposit. Pollutant levels were between 1 μg kg−1 and 5.9 mg kg−1.  相似文献   

15.
A simple and cost effective sample pre-treatment method, dispersive liquid–liquid microextraction (DLLME), has been developed for the extraction of six fluoroquinolones (FQs) from chicken liver samples. Clean DLLME extracts were analyzed for fluoroquinolones using liquid chromatography with diode array detection (LC-DAD). Parameters such as type and volume of disperser solvent, type and volume of extraction solvent, concentration and composition of phosphoric acid in the disperser solvent and pH were optimized. Linearity in the concentration range of 30–500 μg kg−1 was obtained with regression coefficients ranging from 0.9945 to 0.9974. Intra-day repeatability expressed as % RSD was between 4 and 7%. The recoveries determined in spiked blank chicken livers at three concentration levels (i.e. 50, 100 and 300 μg kg−1) ranged from 83 to 102%. LODs were between 5 and 19 μg kg−1 while LOQs ranged between 23 and 62 μg kg−1. All of the eight chicken liver samples obtained from the local supermarkets were found to contain at least one type of fluoroquinolone with enrofloxacin being the most commonly detected. Only one sample had four fluoroquinolone antibiotics (ciprofloxacin, difloxacin, enrofloxacin, norfloxacin). Norfloxacin which is unlicensed for use in South Africa was also detected in three of the eight chicken liver samples analyzed. The concentration levels of all FQs antibiotics in eight samples ranged from 8.8 to 35.3 μg kg−1, values which are lower than the South African stipulated maximum residue limits (MRL).  相似文献   

16.
A relatively fast, simple and very selective liquid chromatography-tandem mass spectrometry (LC-MS-MS) method for the detection of flunixin, its 5-hydroxymetabolite and ketoprofen in raw milk has been developed and validated. After a simple extraction with acetonitrile and partial evaporation of the organic phase, the extract was filtered and directly injected into the LC-MS-MS system on a Symmetry C18 column. The parent ions were selected for further fragmentation with argon. The method developed was partially validated according to Commission Decision 2002/657/EC [Commission Decision 2002/657/EC implementing Council Directive 96/23/EC concerning the performance of analytical methods and the interpretation of results]. The validation parameters were linearity, specificity, repeatability, recovery and decision limit (CCα). CCα varied from 0.5 μg kg−1 for flunixin and 5-hydroxyflunixin to 1 μg kg−1 for ketoprofen.Holstein-Friesian cows were given either Ketofen® or Finadyne® via an intravenous injection at the maximum dose as written in the instructions. Cows were milked twice a day and all samples were analysed by the method described. The highest concentrations found for ketoprofen, flunixin and 5-hydroxyflunixin were 2.5, 6.7 and 590 μg l−1, respectively. The concentration of 5-hydroxyflunixin declined rapidly to concentrations below the MRL value of 40 μg l−1. It can be concluded that the withdrawal time proposed by the pharmaceutical companies, 12 h after the last dosing, is acceptable for both compounds.  相似文献   

17.
Due to the different physico-chemical properties of phenols, the development of a methodology for the simultaneous extraction and determination of phenolic compounds belonging to several families, such as chlorophenols (CPs), alkylphenols (APs), nitrophenols (NTPs) and cresols is difficult. This study shows the development and validation of a method for the analysis of 13 phenolic compounds (including CPs, APs, NTPs and cresols) in agricultural soils. For this purpose, a quick, easy, cheap, effective, rugged and safe (QuEChERS)-based procedure was developed, validated and applied to the analysis of real samples. A derivatization step prior to the final determination by gas chromatography (GC) coupled to a triple quadrupole analyzer operating in tandem mass spectrometry (QqQ-MS/MS) was performed by using acetic acid anhydride (AAA) and pyridine (Py). The optimized procedure was validated, obtaining average extraction recoveries in the range 69–103% (10 μg kg−1), 65–98% (50 μg kg−1), 76–112% (100 μg kg−1) and 76–112% (300 μg kg−1), with precision values (expressed as relative standard deviation, RSD) ≤ 22% (except for 4-chlorophenol) involving intra-day and inter-day studies. Furthermore, 15 real soil samples were analyzed by the proposed method in order to assess its applicability. Some phenolic compounds (e.g. 2,4,6-trichlorophenol or 4-tert-octylphenol) were found in the samples at trace levels (<10 μg kg−1).  相似文献   

18.
A simple and rapid analytical method is presented in which the three veterinary antibiotics oxytetracycline (OTC), sulfachloropyridazine (SCP) and tylosin (TYL) are simultaneously extracted and determined in four different soils. Extractions were carried out by a combination of ultrasonic agitation and vortex mixing using a mixture of methanol, EDTA and McIlvaine buffer at pH 7 as the extractant solution. The extracts were then cleaned-up by a tandem solid phase extraction (SPE) method using an Isolute SAX anion exchange cartridge to remove natural organic matter and an Oasis HLB polymeric cartridge to retain the study compounds. Analysis was by HPLC-UV with additional fluorescence detection for SCP. Recoveries were in the range 68-85% for SCP in all soil types, 58-75% for OTC in sandy soils, 27-51% for OTC in clay containing soils, 74-105% for TYL and 47-61% in a clay soil. OTC and SCP were also extracted from liquid pig manure using a mixture of EDTA and McIlvaine buffer at pH 7 with ultrasonic agitation and vortex mixing with SPE clean-up and HPLC-UV analysis. Recoveries were greater than 77% and 58% for OTC and SCP, respectively. Limits of detection were 18 μg kg−1 for OTC and SCP and 40 μg kg−1 for TYL in soils and 70 μg L−1 for OTC and 140 μg L−1 for SCP in pig slurry.  相似文献   

19.
This paper describes an analytical method involving a simple solvent extraction for the simultaneous liquid chromatography coupled to quadrupole tandem mass spectrometry (LC-MS/MS) determination of carbosulfan, its most toxic metabolite -carbofuran -, and its other main metabolites - 3-hydroxycarbofuran, 3-ketocarbofuran, 3-hydroxy-7-phenolcarbofuran, 3-keto-7-phenolcarbofuran, 7-phenolcarbofuran and dibutylamine - in oranges. Chromatography was performed on a Zorbax Bonus-RP (150 mm × 2.1 mm, 5 μm). The mobile phase was a ternary gradient water-methanol-acetonitrile with 1.0 mM ammonium acetate at flow rate of 0.2 ml min−1. The LC separation and MS/MS optimization were studied to select the most appropriate operating conditions. The method developed has also been validated. The limits of quantification (LOQs) were from 1 μg kg−1 for carbofuran to 10 μg kg−1 for 3-keto-7-phenolcarbofuran. Extracts spiked with carbosulfan and its metabolites, at LOQ level, yielded average recoveries in the range 60-94%, with relative standard deviations (R.S.D.s) less than 15%. Calibration curves for carbosulfan and its metabolites (range LOQ-1000LOQ) were linear, with coefficients of correlations better than 0.990. The method was successfully applied to establish the primary degradation products in oranges treated with carbosulfan. The LC-MS/MS method developed is simple, rapid, and suitable for the quantification and confirmation of carbosulfan and seven of its main metabolites in orange at levels lower than 10 μg kg−1.  相似文献   

20.
Miniaturised ultrasonic solvent extraction procedure was developed for the determination of selected polychlorinated biphenyls (PCBs) in soil samples by gas chromatography-mass-selective detection by using 23 factorial experimental design. Recoveries of PCBs from fortified soil samples are over 90% for three different fortification levels between 40 and 120 μg kg−1, and relative standard deviations of the recoveries are below 7%. The limits of detection (LODs) ranged from 0.003 to 0.006 μg kg−1. The performance of the proposed method was compared to traditional shake flask extraction method on the spiked real soil sample and extraction methods showed comparable efficiencies. Proposed miniaturised ultrasonic solvent extraction offers several advantages, i.e., reducing sample requirement for measurement of target compound, less solvent consumption and reducing the costs associated with solvent purchase and waste disposal.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号