首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 555 毫秒
1.
Determination of perfluorocarboxylic acids (PFCAs) by gas chromatography (GC) has been undertaken since 1980. However, only small number of studies can be found in the literature due to the major drawbacks associated with the GC determination of PFCAs such as high detection limits, a small range of analytes, long analysis time, and laborious derivatization prior to chromatographic separation. Liquid chromatography-tandem mass spectrometry (LC–MS2) can overcome these limitations of GC, and therefore has become the method of choice for the determination of PFCAs since 2001. Nevertheless, GC as a low-cost and commonly available analytical technique should not be ignored because of its inherent advantage over LC to identify PFCA isomers in environmental and biological matrices owing to its high-resolution power. In addition, GC provides an opportunity to crosscheck LC–MS2 results that are often suspicious due to background contamination. This tutorial provides an overview of GC methods that have been used for the determination of PFCAs after derivatization. Moreover, performance characteristics of GC–MS are compared with that of LC–MS2. PFCAs in aqueous samples were determined by both analytical techniques, and two sets of measurements were compared using the Bland-Altman plot. For both methods, reasons for false-positive and false-negative results (overestimation and underestimation of the PFCA concentration, respectively) are discussed, and accordingly some advice is offered on how to avoid erroneous results. Finally, major applications of GC and its future perspectives for the determination of PFCAs are discussed.  相似文献   

2.
The characterization of unknown impurities present in tobramycin by liquid chromatography (LC) coupled with mass spectrometry (MS) is described. A reversed-phase (RP)-LC method using a volatile mobile phase containing a perfluorinated ion-pair reagent was developed and coupled with an ion trap mass spectrometer. The structures of the unknown impurities were deduced by comparison of their fragmentation patterns with those of the available reference substances obtained by LC–MSn experiments.  相似文献   

3.
Multidimensional mass spectrometry interfaces a suitable ionization technique and mass analysis (MS) with fragmentation by tandem mass spectrometry (MS2) and an orthogonal online separation method. Separation choices include liquid chromatography (LC) and ion‐mobility spectrometry (IMS), in which separation takes place pre‐ionization in the solution state or post‐ionization in the gas phase, respectively. The MS step provides elemental composition information, while MS2 exploits differences in the bond stabilities of a polymer, yielding connectivity and sequence information. LC conditions can be tuned to separate by polarity, end‐group functionality, or hydrodynamic volume, whereas IMS adds selectivity by macromolecular shape and architecture. This Minireview discusses how selected combinations of the MS, MS2, LC, and IMS dimensions can be applied, together with the appropriate ionization method, to determine the constituents, structures, end groups, sequences, and architectures of a wide variety of homo‐ and copolymeric materials, including multicomponent blends, supramolecular assemblies, novel hybrid materials, and large cross‐linked or nonionizable polymers.  相似文献   

4.
The supercritical fluid chromatography coupled with mass spectrometry (SFC‐MS) method and liquid chromatography coupled with mass spectrometry (LC‐MS) method were developed for the separation and characterization of poly (ethylene oxide) methyl glucose sesquistearate (PEO‐Glu‐sesquistearate). The products of PEO‐Glu‐sesquistearate are composed of complex oligomers. The relationship between molecular structure of these oligomers and chromatographic retention behavior in both SFC and LC were discussed and compared. As compared with LC, hydrophobic moieties of compounds favor the fast elution in SFC. The different series can be better separated by LC, while the homologues compounds in same series can be better separated by SFC, and SFC‐MS provided more comprehensive structural information. Different series such as PEO‐distearate, PEO‐stearate, PEO, PEO‐Glu‐tetrastearate, PEO‐Glu‐tristearate, PEO‐Glu‐distearate, PEO‐Glu‐stearate, and PEO‐Glu were identified by MS/MS.  相似文献   

5.
As a suitable way for routine screening of pesticides and control of other organic contaminants in water, the combination of liquid chromatography triple quadrupole tandem mass spectrometry (LC–QqQ-MS/MS) and liquid chromatography–hybrid quadrupole time-of-flight mass spectrometry (LC–QTOF-MS) has been applied to the analysis of 63 surface and waste water samples after conventional solid-phase extraction (SPE). The extracts were screened for 43 pesticides or degradation products by LC–QqQ-MS/MS achieving limits of detection (LOD) ranged from 0.04 to 2 ng L−1. Of the 43 selected pesticides, 33 were detected in water samples. The ESI–QTOF MS instrument was run using two simultaneous acquisition functions with low and high collision energy (MSE approach) and acquiring the full mass spectra. A home-made database containing more than 1100 organic pollutants was used for substance identification. Around 250 of these compounds were available at the laboratory as reference standards. Five pesticides and 3 of their degradation products, different to those selected in the QqQ method, were detected by QqTOF-MS. Thirteen pharmaceuticals and two drugs of abuse were also identified in the samples. In practice, the sample preparation proved to be suitable for both techniques and for a wide variety of substances with different polarity. Mutual confirmation and evidence of co-occurrence of several other organic contaminants were the main advantages of the combination of both techniques.  相似文献   

6.
A comprehensive, sensitive and high-throughput liquid chromatography–atmospheric pressure photoionization tandem mass spectrometry (LC–APPI-MS/MS) method has been developed for analysis of 36 halogenated flame retardants (HFRs). Under the optimized LC conditions, all of the HFRs eluted from the LC column within 14 min, while maintaining good chromatographic separation for the isomers. Introduction of the pre-heated dopant to the APPI source decreased the background noise fivefold, which enhanced sensitivity. An empirical equation was proposed to describe the relation between the ion intensity and dopant flow. The excellent on-column instrument detection limits averaged 4.7 pg, which was similar to the sensitivity offered by gas chromatography–high-resolution mass spectrometry (GC–HRMS). This method was used to analyze a series of fish samples. Good agreement was found between the results for PBDEs from LC–APPI-MS/MS and GC–HRMS.  相似文献   

7.
The fact that the effects of herbal medicines (HMs) are brought about by their chemical constituents has created a critical demand for powerful analytical tools performing the chemical analysis to assure their efficacy, safety and quality. Liquid chromatography coupled to mass spectrometry (LC–MS) is an excellent technique to analyze multi-components in complex herbal matrices. Due to its inherent characteristics of accurate mass measurements and high resolution, time-of-flight (TOF) MS is well-suited to this field, especially for qualitative applications. The purpose of this article is to provide an overview on the potential of TOF, including the hybrid quadrupole- and ion trap-TOF (QTOF and IT-TOF), hyphenated to LC for chemical analysis in HMs or HM-treated biological samples. The peculiarities of LC–(Q/IT)TOF-MS for the analysis of HMs are discussed first, including applied stationary phase, mobile-phase selection, accurate mass measurements, fragmentation and selectivity. The final section is devoted to describing the applicability of LC–(Q/IT)TOF-MS to routine analysis of multi-components, including target and non-target (unknown) compounds, in herbal samples, emphasizing both the advantages and limitations of this approach for qualitative and quantitative purposes. The potential and future trends of fast high-performance liquid chromatography (HPLC) (e.g. rapid resolution LC and ultra-performance LC) coupled to (Q)TOF-MS for chemical analysis of HMs are highlighted.  相似文献   

8.
A matrix-assisted laser desorption ionization mass spectrometry (MALDI-MS) method was developed for the high throughput and robust qualitative profiling of alkaloids in Fuzi—the processed lateral roots of the Chinese herbal medicine Aconitum carmichaeli Debx (A. carmichaeli). After optimization, powdered roots – without any further sample preparation – could be used to screen for the presence of Aconitum alkaloids. Furthermore, the semi-quantitative potential of MALDI-MS was confirmed using liquid chromatography–mass spectrometry (LC–MS) as reference. In total over sixty alkaloids were detected by LC–MS and fifteen of them were tentatively identified. Both MALDI-MS and LC–MS analysis revealed significant variation in alkaloid content in different (commercial) samples. LC–MS analysis of three toxic alkaloids in 14 batches of Fuzi resulted in a variation of their concentrations expressed as RSDs of 138%, 99% and 221% for aconitine, hypaconitine and mesaconitine, respectively. The variation in concentrations (expressed as RSD) of about the ninety constituents detected were classified as follows: 13 constituents showed an RSD of 77–100%, 46 with an RSD of 100–150%, 21 with an RSD of 150–200% and 9 constituents with an RSD in concentration of 200–235%. These results demonstrate a strong difference in chemical composition of the various Fuzi and illustrate the necessity of adequate QA/QC procedures for both safety and efficiency of herbal medicine. The described analytical procedures for alkaloid profiling could play a role in these procedures.  相似文献   

9.
Benazepril, an anti-hypertensive drug, was subjected to forced degradation studies. The drug was unstable under hydrolytic conditions, yielding benazeprilat, which is a known major degradation product (DP) and an active metabolite. It also underwent photochemical degradation in acid and neutral pH conditions, resulting in multiple minor DPs. The products were separated on a reversed phase (C18) column in a gradient mode, and subjected to LC–MS and LC–NMR studies. Initially, comprehensive mass fragmentation pathway of the drug was established through support of high resolution mass spectrometric (HR-MS) and multi stage tandem mass spectrometric (MSn) data. The DPs were also subjected to LC–MS/TOF studies to obtain their accurate masses. Along with, on-line H/D exchange data were obtained to ascertain the number of exchangeable hydrogens in each molecule. LC–1H NMR and LC–2DNMR data were additionally acquired in a fraction loop mode. The whole information was successfully employed for the characterization of all the DPs. A complete degradation pathway of the drug was also established.  相似文献   

10.
Quantitation of trace levels of domoic acid (DA) in seawater samples usually requires labour-intensive protocols involving chemical derivatization with 9-fluorenylmethylchloroformate and liquid chromatography with fluorescence detection (FMOC–LC–FLD). Procedures based on LC–MS have been published, but time-consuming and costly solid-phase extraction pre-concentration steps are required to achieve suitable detection limits. This paper describes an alternative, simple and inexpensive LC method with ultraviolet detection (LC–UVD) for the routine analysis of trace levels of DA in seawater without the use of sample pre-concentration or derivatization steps. Qualitative confirmation of DA identity in dubious samples can be achieved by mass spectrometry (LC–MS) using the same chromatographic conditions. Addition of an ion-pairing/acidifying agent (0.15% trifluoroacetic acid) to sample extracts and the use of a gradient elution permitted the direct analysis of large sample volumes (100 μl), resulting in both high selectivity and sensitivity (limit of detection = 42 pg ml−1 by LC–UVD and 15 pg ml−1 by LC–MS). Same-day precision varied between 0.4 and 5%, depending on the detection method and DA concentration. Mean recoveries of spiked DA in seawater by LC–UVD were 98.8% at 0.1–10 ng ml−1 and 99.8% at 50–1000 ng ml−1. LC–UVD exhibited strong correlation with FMOC–LC–FLD during inter-laboratory analysis of Pseudo-nitzschia multiseries cultures containing 60–2000 ng DA ml−1 (r2 > 0.99), but more variable results were obtained by LC–MS (r2 = 0.85). This new technique was used to confirm the presence of trace DA levels in low-toxicity Pseudo-nitzschia spp. isolates (0.2–1.6 ng ml−1) and in whole-water field samples (0.3–5.8 ng ml−1), even in the absence of detectable Pseudo-nitzschia spp. cells in the water column.  相似文献   

11.
Triacylglycerols (TAGs) provide a challenge for mass spectrometry (MS) analysis because of their complexity. In particular, for dietary, nutritional and metabolic purposes, the positional placement of fatty acids on the glycerol backbone of TAGs is a crucial aspect. To solve this problem, we have investigated the TAGs' fragmentation patterns using an ion trap mass spectrometer. A series of pure regioisomeric pairs of TAGs (POP/PPO, POO/OPO and OSO/SOO) were cationized by Ag+ after their separation by non‐aqueous reversed‐phase liquid chromatography (NARP‐LC) before MS to improve MS sensitivity. Electrospray ionization–MS (ESI‐MS) conditions were optimized in order to produce characteristic [M + Ag + AgNO3]+ ions from each TAG, which were then fragmented to produce MS/MS spectra and then fragmented further to produce up to MS5 spectra. The observation of ions produced by LC‐MS5 of on‐line Ag+‐cationized TAG provided unambiguous information on the fatty acid distribution on the glycerol backbone. These strategies of MS to MS5 experiments were applied to identify components and to determine the regiospecificity of TAG within a complex mixture of lipids in natural oils. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

12.
Synthetic polymers are naturally mixtures of homologs, even in pure form. More complexity is introduced by the presence of different comonomers, end groups and/or macromolecular architectures. The analysis of such systems is substantially facilitated by interfacing mass spectrometry (MS), which disperses based on mass, with an additional level of separation involving either interactive liquid chromatography (LC) or ion mobility (IM) spectrometry, both of which are readily coupled online with electrospray ionization and MS detection. IM-MS separates in the gas phase, post-ionization and, therefore, is ideally suitable for labile and reactive polymers. Its usefulness is illustrated with the characterization of non-covalent siloxane-saccharide complexes, metallosupramolecular assemblies and an air- and moisture-sensitive inorganic polymer, poly(dichlorophosphazene). Conversely, LC-MS which separates in solution phase, before ionization, is most effective for the analysis of polymeric mixtures whose components differ in polarity. Interactive LC conditions can be optimized to disperse by the content of hydrophobic units, as is demonstrated for amphiphilic polyether copolymers and sugar-based nonionic surfactant blends. Both LC-MS and IM-MS can be extended into a third dimension by tandem mass spectrometry (MS(2)) studies on select oligomers, in order to obtain insight into individual end groups and isomeric architectures, comonomer sequences and degree of substitution, for example, by hydrophobic functionalities.  相似文献   

13.
Tomato (Lycopersicon esculentum Mill.) is the second most important fruit crop worldwide. Tomatoes are a key component in the Mediterranean diet, which is strongly associated with a reduced risk of chronic degenerative diseases. In this work, we use a combination of mass spectrometry (MS) techniques with negative ion detection, liquid chromatography/electrospray ionization linear ion trap quadrupole‐Orbitrap‐mass spectrometry (LC/ESI‐LTQ‐Orbitrap‐MS) and liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI‐MS/MS) on a triple quadrupole, for the identification of the constituents of tomato samples. First, we tested for the presence of polyphenolic compounds through generic MS/MS experiments such as neutral loss and precursor ion scans on the triple quadrupole system. Confirmation of the compounds previously identified was accomplished by injection into the high‐resolution system (LTQ‐Orbitrap) using accurate mass measurements in MS, MS2 and MS3 modes. In this way, 38 compounds were identified in tomato samples with very good mass accuracy (<2 mDa), three of them, as far as we know, not previously reported in tomato samples. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

14.
Plant metabolites represent complex chemical system, which renders it difficult to clarify the chemical composition by conventional liquid chromatography/mass spectrometry (LC/MS) due to the limited selectivity and peak capacity. The rhizomes of Atractylodes macrocephala have been utilized as a traditional Chinese medicine Atractylodis Macrocephalae Rhizoma (Bai-Zhu), and have been reported containing multiple categories of plant metabolites. Targeting the multicomponents from A. macrocephala, an integral approach by offline two-dimensional liquid chromatography/ion mobility quadrupole time-of-flight mass spectrometry (2D-LC/IM-QTOF-MS) was established and validated. By configuring an XBridge Amide column of Hydrophilic Interaction Chromatography and an Atlantis Premier BEH C18AX column of mixed ion exchange and reversed-phase modes, the established 2D-LC/IM-QTOF-MS system showed high orthogonality up to 0.91. Dimension-enhanced, data-independent high-definition MSE (HDMSE) in the positive ESI mode was conducted on a Vion IM-QTOF mass spectrometer, and its hyphenation to offline 2D-LC could enable the four-dimensional separation (each dimension in 2D-LC, IM, and MS). Particularly, HDMSE facilitated the acquisition of high-definition MS1 and MS2 spectra. In-house library-driven computational peak annotation by the bioinformatics platform UNIFI could efficiently process and annotate the HDMSE data for the structural elucidation. By integrating reference compounds comparison, we could identify or tentatively characterize 251 components from A. macrocephala (including 115 sesquiterpenoids, 90 polyacetylenes, 11 flavonoids, 9 benzoquinones, 12 coumarins, and 14 others), which indicated large improvement in identifying those minor plant components, compared with the conventional LC/MS approach. Conclusively, offline 2D-LC/IM-QTOF-HDMSE in combination with computational data interpretation proves to be powerful facilitating the in-depth multicomponent characterization of herbal medicine.  相似文献   

15.
Improved methods for structural analyses of glycosaminoglycans (GAGs) are required to understand their functional roles in various biological processes. Major challenges in structural characterization of complex GAG oligosaccharides using liquid chromatography-mass spectrometry (LC-MS) include the accurate determination of the patterns of sulfation due to gas-phase losses of the sulfate groups upon collisional activation and inefficient on-line separation of positional sulfation isomers prior to MS/MS analyses. Here, a sequential chemical derivatization procedure including permethylation, desulfation, and acetylation was demonstrated to enable both on-line LC separation of isomeric mixtures of chondroitin sulfate (CS) oligosaccharides and accurate determination of sites of sulfation by MS n . The derivatized oligosaccharides have sulfate groups replaced with acetyl groups, which are sufficiently stable to survive MS n fragmentation and reflect the original sulfation patterns. A standard reversed-phase LC-MS system with a capillary C18 column was used for separation, and MS n experiments using collision-induced dissociation (CID) were performed. Our results indicate that the combination of this derivatization strategy and MS n methodology enables accurate identification of the sulfation isomers of CS hexasaccharides with either saturated or unsaturated nonreducing ends. Moreover, derivatized CS hexasaccharide isomer mixtures become separable by LC-MS method due to different positions of acetyl modifications.  相似文献   

16.
A multidimensional LC–MS/MS configuration is described for targeted quantitation of a highly basic peptide chemically derived from pegvisomant as a surrogate for the intact protein. The method developed for an immunogenicity assay employed orthogonal separation of the target peptide commencing with flowing microgram quantities of total digests from a protein G extraction of human serum through a weak cation exchange (WCX) monolithic trap column. The basic peptide of interest was retained on the WCX column. Following a washing procedure, peptides were eluted with acetic acid and retained on a down-stream reverse phase trap compatible with online nanoflow LC–MS/MS. Such a LC configuration including the use of other sorbents such as strong cation exchange media is proposed as an enabling tool in assay development for quantitative protein bioanalysis by LC–MS/MS.  相似文献   

17.
The alkaloid ricinine, an insecticide for leaf-cutting ant (Atta sexdens rubropilosa), was obtained from Ricinus communis. A two-phase solvent system composed of CH2Cl2/EtOH/H2O (93:35:72, v/v/v) was used for high-speed counter-current chromatographic (HSCCC) isolation of ricinine in high yield and with over 96% purity, as determined by liquid and gas chromatography–mass spectrometry (LC–MS and GC–MS). Identification of ricinine was performed by comparison of 1H NMR, 13C NMR and LC–MS/MS data.  相似文献   

18.
Liquid chromatography/mass spectrometry (LC/MS) and liquid chromatography/tandem mass spectrometry (LC/MS/MS) were applied to characterize drug metabolites. Although these two methods have overcome the identification and structural characterization of metabolites analysis, they remain time‐consuming processes. In this study, a novel multiple‐stage tandem mass spectrometric method (MSn) was evaluated for identification and characterization of new minor metabolism profiling of penicillin G, one of the β‐lactam antibiotics, in human serum. Seven minor metabolites including five phase I metabolites and two phase II metabolites of penicillin G were identified by using data‐dependent LC/MSn screening in one chromatographic run. The accuracy masses of seven identified metabolites of penicillin G were also confirmed by mass spectral calibration software (MassWorks?). The proposed data‐dependent LC/MSn method is a powerful tool to provide large amounts of the necessary structural information to characterize minor metabolite in metabolism profiling. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

19.
This paper describes the development of an optimized method based on solid-phase extraction (SPE) followed by liquid chromatography–electrospray ionization tandem mass spectrometry (LC–MS/MS) for the simultaneous analysis of ten antibiotic compounds including tetracyclines, sulfonamides, macrolides and quinolones. LC–MS/MS sensitivity has been optimized by alterations to both LC and MS operations. Of the two high resolution columns tested, Waters Symmetry C18 endcapped and Agilent Zorbax Bonus-RP, the latter was found to show better performance in producing sharp peaks and clear separation for most of the target compounds. Optimization of the MS fragmentation collision and cone energy enhanced the peak areas of the target analytes. The recovery of the target compounds from water samples was most efficient on Waters Oasis HLB SPE cartridge, while methanol was shown to be the most suitable solvent for desorbing the compounds from SPE. In addition, acidification of samples prior to SPE was shown to enhance the recovery of the compounds. To ensure a satisfactory recovery, the flow rate through SPE should be maintained at ≤10 mL min−1. The method was successfully applied to the analysis of antibiotics from environmental water samples, with concentrations being <LOD in tap water, between <LOD to 28 ng L−1 in river water and between <LOD to 230 ng L−1 in sewage effluent.  相似文献   

20.
This is the part I of a tutorial review intending to give an overview of the state of the art of method validation in liquid chromatography mass spectrometry (LC–MS) and discuss specific issues that arise with MS (and MS/MS) detection in LC (as opposed to the “conventional” detectors). The Part I briefly introduces the principles of operation of LC–MS (emphasizing the aspects important from the validation point of view, in particular the ionization process and ionization suppression/enhancement); reviews the main validation guideline documents and discusses in detail the following performance parameters: selectivity/specificity/identity, ruggedness/robustness, limit of detection, limit of quantification, decision limit and detection capability. With every method performance characteristic its essence and terminology are addressed, the current status of treating it is reviewed and recommendations are given, how to determine it, specifically in the case of LC–MS methods.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号