首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The synthesis of branched poly(ethylene glycol) (PEG) derivatives, namely star PEG and dendronized PEG, can be challenging and their purity can be difficult to ascertain using traditional techniques, such as NMR and GPC. Herein, the detailed characterization of these branched PEGs using MALDI-ToF MS was investigated in order to confirm their structural purity. In this light, mass spectrometry offers a number of advantages for polymer characterization, including the ability to get detailed structural data, such as end group masses, from microgram-scale samples. In addition, the ability to rapidly acquire data from crude reaction aliquots makes MALDI-ToF MS ideal for monitoring end group transformations.  相似文献   

2.
Synthetic copolyamides based on aliphatic diamines (1,3-propanediamine and 1,4-butanediamine) and dichlorides of aliphatic carboxylic acids (adipic and sebacic acid dichlorides) were investigated using time-of-flight matrix assisted laser desorption/ionization mass spectrometry. Their mass spectra showed peaks for cationized (Na+ and K+) and protonated (less intense peaks) oligomers with NH2-NH2, NH2-COOH, or COOH-COOH end groups. No cyclic oligomers were detected in the samples. The compositions of oligomers were determined, and the relative reactivities of homologous comonomers in polycondensation were estimated. Published in Russian in Izvestiya Akademii Nauk. Seriya Khimicheskaya, No. 7, pp. 1320–1324, July, 2007.  相似文献   

3.
Here, N,N′-bis(4-hydroxylsalicylidene)-p-phenylenediamine (BSPD-OH), N,N′-bis(4-methoxylsalicylidene)-p-phenylenediamine (BSPD-OMe) and N,N′-bis(salicylidene)-p-phenylenediamine (BSPD), which belong to the same category of aggregation-induced emission (AIE) compounds based on Schiff base reactions, were synthesized and applied as new matrices in the analysis of small molecules by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). This type of AIE compounds can be good MALDI matrices. Conventional organic matrices often produce large amounts of matrix ions, hindering the analysis of low molecular weight (LMW) compounds. However, these AIE compounds generate few matrix ions and less background interference because their presence as aggregates decreases the generation of matrix interference. The sensitivity of the AIE matrix is high because the aggregates can improve the absorption of the applied laser emissions. We can regulate the ionization efficiency of the AIE matrix by changing its aggregation state. During this study, BSPD-OH exhibited better ionization efficiency than the other two AIE matrices because it has more phenolic hydroxyl groups. BSPD-OH was successfully applied to the analysis of various LMW compounds including amino acids, organic amine compounds, isoquinoline compounds and fluoroquinolones compounds. This material also can be employed during the qualitative and quantitative analysis of LMW metabolites in human urine without requiring complicated separation processes.  相似文献   

4.
This report focuses on the heterogeneous distribution of small molecules (e.g. metabolites) within dry deposits of suspensions and solutions of inorganic and organic compounds with implications for chemical analysis of small molecules by laser desorption/ionization (LDI) mass spectrometry (MS). Taking advantage of the imaging capabilities of a modern mass spectrometer, we have investigated the occurrence of “coffee rings” in matrix-assisted laser desorption/ionization (MALDI) and surface-assisted laser desorption/ionization (SALDI) sample spots. It is seen that the “coffee-ring effect” in MALDI/SALDI samples can be both beneficial and disadvantageous. For example, formation of the coffee rings gives rise to heterogeneous distribution of analytes and matrices, thus compromising analytical performance and reproducibility of the mass spectrometric analysis. On the other hand, the coffee-ring effect can also be advantageous because it enables partial separation of analytes from some of the interfering molecules present in the sample. We report a “hidden coffee-ring effect” where under certain conditions the sample/matrix deposit appears relatively homogeneous when inspected by optical microscopy. Even in such cases, hidden coffee rings can still be found by implementing the MALDI-MS imaging technique. We have also found that to some extent, the coffee-ring effect can be suppressed during SALDI sample preparation.  相似文献   

5.
In this paper, mesoporous tungsten titanate (WTiO) with different nano-pore structures was utilized as matrix for the analysis of short peptides by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS). Effect of characteristic features of mesoporous matrices on laser desorption/ionization process was investigated. Experiments showed that the ordered two-dimensional and three-dimensional mesoporous matrices were superior in performance to the non-ordered WTiO matrix. The dramatic enhancement of signal sensitivity by the ordered mesoporous matrices can be reasonably attributed to the ordered structure, which facilitated the understanding on structure-function relationship in mesoporous cavity for laser desorption process of adsorbed biomolecules. With the ordered mesoporous matrix, the short peptides are successfully detected. The presence of trace alkali metal salt effectively increased the analyte ion yields and the MALDI-TOFMS using the inorganic mesoporous matrices displayed a high salt tolerance. The developed technique also showed a satisfactory performance in peptide-mapping and amino-acid sequencing analysis.  相似文献   

6.
In this paper, we describe a new method for determining the exchange rates of alkanethiolates in self-assembled monolayers (SAMs) on gold using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) to analyze the compositions of the alkanethiolate in SAMs rapidly and directly. In particular, to investigate the self-exchange of alkanethiols, we prepared a deuterated alkanethiol that has the same molecular properties as the non-deuterated alkanethiol but a different molecular weight. SAMs consisting of deuterated alkanethiolates were immersed in a solution of the non-deuterated alkanethiol, and the influences of the immersion time, temperature, concentration, and solvent on the self-exchange rates were investigated. Furthermore, we assessed the exchange rates among alkanethiols with different carbon chain lengths and different size of ethylene glycol units. In addition, we performed molecular dynamics simulations using a model SAM system in order to understand the molecular mechanism of the exchange process.  相似文献   

7.
Characterization of membrane proteins remains an analytical challenge because of difficulties associated with tedious isolation and purification. This study presents the utility of the polyvinylidene difluoride (PVDF) membrane for direct sub-proteome profiling and membrane protein characterization by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). The hydrophobic adsorption of protein, particularly membrane proteins, on the PVDF surface enables efficient on-PVDF washing to remove high concentrations of detergents and salts, such as up to 5% sodium dodecyl sulfate (SDS). The enhanced spectrum quality for MALDI detection is particularly notable for high molecular weight proteins. By using on-PVDF washing prior to MALDI detection, we obtained protein profiles of the detergent-containing and detergent-insoluble membrane fractions from Methylococcus capsulatus (Bath). Similar improvements of signal-to-noise ratios were shown on the MALDI spectra for proteins electroblotted from SDS-polyacrylamide gel electrophoresis (SDS-PAGE) onto the PVDF membrane. We have applied this strategy to obtain intact molecular weights of the particulate methane monooxygenase (pMMO) composed of three intrinsic membrane-bound proteins, PmoA, PmoB, and PmoC. Together with peptide sequencing by tandem mass spectrometry, post-translational modifications including N-terminal acetylation of PmoA and PmoC and alternative C-terminal truncation of PmoB were identified. The above results show that PVDF-aided MALDI-MS can be an effective approach for profiling and characterization of membrane proteins.  相似文献   

8.
Thirteen extracting solutions of rare-earth metallofullerenes containing La,Ce,Pr,Nd Sm,Eu,Gd,Tb,Dy,Ho,Er,Tm and Yb respectively have been investigated by means of matrix-assisted laser desorpuon/ ionization time-of-flight mass spectrometry.The influences of the positive-ion/negative-ion mode,laser intensity,ma trix and mass discrimination to the analytical results are studied,based on which the optimal analytical conditions have been determined.The results show that the extracting solutions contain large quantities of rare-earth metallofullerenes besides empty fullerenes.On the basis of comparing their relative intensities,the different structure stabilities and solubilities of metallofullerenes with different rare-earth metals encapsulated into the fullerene cages,as well as some possible reasons to those differences,are discussed.  相似文献   

9.
采用基质辅助激光解吸电离飞行时间质谱(MALDI-TOF-MS),对四硫富瓦烯化合物进行质谱表征。在所用的实验条件下,样品很容易解吸电离生成单电荷分子离子,得到单同位素分辨的质谱图。26种实际样品的质谱分析结果表明;MALDI-TOF-MS可以比其它质谱方法更有效、更方便地用于此类化合物的质谱分析,解决了此类化合物不易进行质谱鉴定的难题。  相似文献   

10.
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is a useful technique for the identification of bacteria on the basis of their characteristic protein mass spectrum fingerprint. Highly standardized instrumental analytical performance and bacterial culture conditions are required to achieve useful information. A chemometric approach based on multivariate analysis techniques was developed for the analysis of MALDI data of different bacteria to allow their identification from their fingerprint. Principal component analysis, linear discriminant analysis (LDA) and soft independent modelling of class analogy (SIMCA) were applied to the analysis of the MALDI MS mass spectra of two pathogenic bacteria, Escherichia coli O157:H7 and Yersinia enterocolitica, and the non-pathogenic E. coli MC1061. Spectra variability was assessed by growing bacteria in different media and analysing them at different culture growth times. After selection of the relevant variables, which allows the evaluation of an m/z value pattern with high discriminant power, the identification of bacteria by LDA and SIMCA was performed independently of the experimental conditions used. In order to better evaluate the analytical performance of the approach used, the ability to correctly classify different bacteria, six wild-type strains of E. coli O157:H7, was also studied and a combination of different chemometric techniques with a severe validation was developed. The analysis of spiked bovine meat samples and the agreement with an independent chemiluminescent enzyme immunoassay demonstrated the applicability of the method developed for the detection of bacteria in real samples. The easy automation of the MALDI method and the ability of multivariate techniques to reduce interlaboratory variability associated with bacterial growth time and conditions suggest the usefulness of the proposed MALDI MS approach for rapid routine food safety checks. Figure Workflow of the developed MALDI-TOF MS and chemometric approach for the analysis and classification of bacteria Electronic supplementary material  The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

11.
In this work, we wanted to devise a reliable method to characterize polymerized forms of tannins, their structural information and mass distribution. Size-exclusion chromatography (SEC) is a chromatographic technique used to determine molecular mass (weight) distributions of polymers. One important step in the data treatment is the modeling of the calibration curves. Polystyrenes (PS) are standards usually used because no commercial procyanidin (PC) standards are available. An off-line coupling of SEC and MALDI was carried out to measure differences between polystyrenes and procyanidins. Thus, a new calibration curve was established; from 1000 to 8000 Da, there is a good correlation between the MALDI and PS calibration curves, in this field the PS calibration is correct and enables true mass determination. For masses above 8000 Da, PS calibration overestimates the real molecular weight of PC, overestimation of 53%. And for masses below 1000 Da, PS calibration underestimates their real molecular weight (10-15%). This means that to truly characterize PC, calibration based on PC standards is required.  相似文献   

12.
As one of the most prevalent and complex post-translational modifications in biological systems, proteins glycosylation has drawn considerable attention in recent decades. Dissociation of the carbohydrates from glycoproteins may be the prerequisite step of glycomics experiments, which commonly performed by specific proteolysis. In this study, an alternative strategy was reported with nonspecific proteolysis in coupling with co-derivatization of TMPP-Ac and methylamidation for glycan moieties analysis by MALDI-MS. With the co-derivatization, a permanent positive charge was introduced to the Asn-glycans and the carboxylic groups were neutralized by methylamidation simultaneously. As a result, approximately 20 and 50-fold enhancement in the detection sensitivity was achieved for asialo-Asn and disialo-Asn respectively in comparison to their native counterparts. Ultimately, this developed strategy was successfully validated using three model glycoproteins, including ribonuclease B, ovalbumin and transferrin.  相似文献   

13.
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) was applied to the analysis of Ru(OCOCF(3))(2)(CO)(PPh(3))(2), Ru(OCOC(3)F(7))(2)(CO)(PPh(3))(2), Ir(tBuppy)(3) and Ir(ppy)(2)(acac) complexes. A troublesome problem in the MALDI-TOFMS characterization of these metal complexes is the possible replacement of complex ligands by matrix. In this contribution, 10 matrices, ranging from acidic to basic, were investigated: alpha-cyano-4-hydroxycinnamic acid (CHCA), 2,5-dihydroxybenzoic acid (DHB), sinapinic acid (SA), dithranol, 2,4,6-trihydroxyactophenone (THAP), 6-azo-2-thiothymine (ATT), norharman, 2-[(2E)-3-(4-tert-butylphenyl)-2-methylprop-2-enylidene]malononitrile (DCTB), 4-nitroaniline (NA) and 2-amino-5-nitrophyridine (ANP). With most of the matrices, including the neutral and basic ones, matrix substitution of ligand could clearly be detected. Based on the experimental results, possible mechanisms of matrix substitution were discussed. It was demonstrated that the ligand exchange process might also occur through the gas-phase reactions initiated by laser shots. Among the matrices tested, DCTB was found to be the best one for the complexes that are prone to ligand exchange by matrix.  相似文献   

14.
The detection of water-soluble vitamins B(1), B(2), B(6), B(12) and C by matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectrometry (TOFMS) was attempted by studying 17 porphyrin matrices. Comparative studies of porphyrin matrices, useful mass spectral window, matrix/analyte molar ratio (M/A), ultraviolet-visible absorption characteristics and quantitative results were made. Most porphyrin matrices provide a useful mass spectral window in the low-mass range. The optimal M/A increases with increasing molecular mass of the vitamin. Vitamin B(12) possesses the highest molecular mass and requires a higher M/A. The presence of hydroxyl or carboxyl groups in the porphyrin is an indicator of a useful MALDI matrix. Vitamins B(2) and B(6) were readily ionized upon irradiation with a 337 nm laser without the use of any porphyrin matrix. Improved linearity and sensitivity of the calibration curves were obtained with samples prepared with a constant M/A. The limits of detection and quantitation are at the picomole level. The results indicate that MALDI-TOFMS with porphyrin matrices is a rapid and viable technique for the detection of low molecular mass water-soluble vitamins.  相似文献   

15.
A novel sample preparation method of matrix-assisted laser desorption/ionization mass spectrometry for polystyrene was reported. Compared to the conventional dried-droplet method, the efficiency of ionization and signal intensity of mass spectra were improved. The mechanism was also analyzed.  相似文献   

16.
Accurate bacterial identification is important in diagnosing disease and in microbial forensics. Coxiella burnetii, a highly infective microorganism causative of the human disease Q fever, is now considered a U.S. category B potential bioterrorism agent. We report here an approach for the confirmatory identification of C. burnetii at the strain level which involves the combined use of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) and supervised pattern recognition via Partial Least Squares-Discriminant Analysis (PLS-DA). C. burnetii isolates investigated in this study included the following prototype strains from different geographical and/or historical origins and with different antigenic properties: Nine Mile I, Australian QD, M44, KAV, PAV, Henzerling, and Ohio. After culture and purification following standard protocols, linear MALDI-TOF mass spectra of pure bacterial cultures were acquired in positive ion mode. Mass spectral data were normalized, baseline-corrected, denoised, binarized and modeled by PLS-DA under crossvalidation conditions. Robustness with respect to uncontrolled variations in the sample preparation and MALDI analysis protocol was assessed by repeating the experiment on five different days spanning a period of 6 months. The method was validated by the prediction of unknown C. burnetii samples in an independent test set with 100% sensitivity and specificity for five out of six strain classes.  相似文献   

17.
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) was used in conjunction with size exclusion chromatography (SEC) to investigate a model polyester system based on phthalic anhydride–1,2-propylene glycol. The polyesters were synthesized with a 30% molar excess of glycol, with kinetic samples being removed during different intervals of the polyesterification reaction. SEC was used to track the course of the reaction by determining the molecular weight and molecular weight distributions before subsequent off-line coupling with MALDI-TOF MS as a selective detection method to determine the chemical composition, identify the functionality type distributions as well as assist in assigning structural conformations. Mass spectrometry analysis proved to be a highly effective tool to facilitate the identification of the narrowly dispersed fractions obtained from the chromatographic separations as well as serve as a core method to investigate the heterogeneous nature of the bulk kinetic samples. Through the hyphenation of these sophisticated polymer characterization techniques, information on the molecular heterogeneity of the model polyesters, showing a complex variety of possible distributions, was obtained.  相似文献   

18.
C(alpha)-Formylglycine, the catalytic amino acid residue in the active site of sulfatases, is generated by post-translational modification of a cysteine or serine residue. We describe a highly sensitive procedure for the detection of C(alpha)-formylglycine-containing peptides in tryptic digests of sulfatase proteins. The protocol is based on the formation of hydrazone derivatives of C(alpha)-formylglycine-containing peptides when using dinitrophenylhydrazine as a matrix for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS). The hydrazone derivatives desorb and ionize with high efficiency and can be detected in the sub-femtomole range. The presence of C(alpha)-formylglycine is indicated by a mass increment of 180.13 u, corresponding to the hydrazone moiety, and also by a unique C-terminal fragment ion, characteristic of sulfatases, that becomes prominent in MALDI post-source decay mass spectra of the hydrazone derivatives.  相似文献   

19.
A prototype matrix-assisted laser desorption/ionization quadrupole time-of-flight (MALDI-TOF) tandem mass spectrometer was used to sequence a series of phosphotyrosine-, phosphothreonine- and phosphoserine-containing peptides. The high mass resolution and mass accuracy of the instrument allowed the localization of one, three or four phosphorylated amino acid residues in phosphopeptides up to 3.1 kDa. Tandem mass spectra of two different phosphotyrosine peptides permitted amino acid sequence determination and localization of one and three phosphorylation sites, respectively. The phosphotyrosine immonium ion at m/z 216.04 was observed in these MALDI low-energy CID tandem mass spectra. Elimination of phosphate groups was evident from the triphosphorylated peptide but not from the monophosphorylated species. The main fragmentation pathway for the synthetic phosphothreonine-containing peptide and for phosphoserine-containing peptides derived from beta-casein and ovalbumin was the beta-elimination of phosphoric acid with concomitant conversion of phosphoserine to dehydroalanine and phosphothreonine to 2-aminodehydrobutyric acid. Peptide fragment ions of the b- and y-type allowed, in all cases, the localization of phosphorylation sites. Ion signals corresponding to (b-17), (b-18) and (y-17) fragment ions were also observed. The abundant neutral loss of phosphoric acid (-98 Da) is useful for femtomole level detection of phosphoserine-peptides in crude peptide mixtures generated by gel in situ digestion of phosphoproteins.  相似文献   

20.
The applicability of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) to the qualitative and quantitative analysis of most mammalian phospholipid (PL) classes was demonstrated in a crude extract of porcine lens membranes. When 2,5-dihydroxybenzoic acid (DHB) was used as the matrix, positive-ion spectra allowed the accurate quantification of phosphatidylcholines (PCs) and sphingomyelins (SMs). Other PLs such as phosphatidylethanolamines (PEs), phosphatidylethanolamine plasmalogens (PEps), phosphatidylethanolamine ethers (PEes) and phosphatidylserines (PSs), could also be detected, but their lower ionization efficiency led to negative errors in their quantification. Despite this limitation, it was possible to determine relative changes among PLs extracted from cortical and nuclear regions. Negative-ion spectra were acquired with the use of p-nitroaniline (PNA) as the matrix. Because neither PCs nor SMs produce negative ions, other PL classes can be analyzed selectively. The absolute quantification of the various PL classes detectable in negative-ion spectra was also affected by differences in ionization efficiencies. However, the trends in compositional changes between cortical and nuclear-fiber PLs were in agreement with those obtained by (31)P NMR spectroscopy. MALDI-TOFMS also offers the possibility of studying variations in the acyl-chain distribution of the various species comprising each PL class. For porcine lenses, PCs, PEs and phosphatidylinositols (PIs) exhibited the greatest depletions in going from cortical to nuclear membranes. Among their individual species, those with two or more sites of unsaturation suffered the most significant reduction.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号