首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 531 毫秒
1.
Some water and soil extracts polluted with arsenic, and a sewage sludge certified for total arsenic have been analysed by high‐performance liquid chromatography–inductively coupled plasma–mass spectrometry (HPLC–ICP–MS) and hydride generation–gas chromatography– quartz furnace atomic absorption spectrometry (HG–GC–QFAAS techniques.) Detection limits in the range of 200–400 and 2–10 ng l−1 respectively allowed the determination of inorganic [As(III), As(V)] and methylated (DMA, MMA, TMAO) arsenic species present in these samples. Results obtained by both methods are well correlated overall, whatever the arsenic chemical form and concentration range (8–10 000 μg l−1). Comparison of these results enabled us to point out features and disadvantages of each analytical method and to reach a conclusion that they are suitable for arsenic speciation in these environmental matrices. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

2.
The potential of coupling anion-exchange high-performance liquid chromatography, hydride generation and atomic fluorescence spectrometry (HPLC–HG–AFS) for arsenic speciation is considered. The effects of hydrochloric acid and sodium tetrahydroborate concentrations on signal-to-background ratio, as well as argon and hydrogen flow rates, were investigated. Detection limits for arsenite, dimethylarsinic acid (DMA), monomethylarsonic acid (MMA) and arsenate were 0.17, 0.45, 0.30 and 0.38 μg l−1, respectively, using a 20-μl loop. Linearity ranges were 0.1–500 ng for As(III) and MMA (as arsenic), and 0.1–800 ng for DMA and As(V) (as arsenic). Arsenobetaine (AsB) was also determined by introducing an on-line photo-oxidation step after the chromatographic separation. In this case the limits of detection and linear ranges for the different species studied were similar to the values obtained previously for As(V). The technique was tested with a human urine reference material and a volunteer's sample. © 1998 John Wiley & Sons, Ltd.  相似文献   

3.
Hydride generation atomic fluorescence spectrometry (HG-AFS) is used for the determination of hydride-forming elements due to its high sensitivity, simplicity, and low cost. A new HG-AFS method for the simultaneous determination of arsenic and lead in vegetable oil is reported. Vortex-assisted extraction with dilute nitric acid was used to isolate arsenic and lead from vegetable oil. The conditions influencing the fluorescence signal, including the carrier fluid, oxidizing agent, and reducing agent, were optimized. The interferences of coexisting ions were also evaluated. Under the optimized conditions, the limits of detection were 0.6 and 0.4?µg?kg?1 for arsenic and lead. The recoveries were from 84.4 to 105% for both metals in vegetable oil. The optimized method was used for the determination of arsenic and lead in commercial vegetable oil. The analytical results by this approach were in good agreement with values obtained by inductively coupled plasma mass spectrometry with microwave digestion.  相似文献   

4.
New materials have significant impact on the development of new methods and instrumentation for chemical analysis. From the discovery of carbon nanotubes in 1991, single and multi-walled carbon nanotubes – due to their high adsorption and desorption capacities – have been employed as sorption substrates in solid-phase extraction for the preconcentration of metal species from diverse matrices. Looking for successive improvements in sensitivity and selectivity, in the past few years, carbon nanotubes have been utilized as sorbents for solid phase extraction in three different ways: like as-grown, oxidized and functionalized nanotubes. In the present paper, an overview of the recent trends in the use of carbon nanotubes for solid phase extraction of metal species in environmental, biological and food samples is presented. The determination procedures involved the adsorption of metals on the nanotube surface, their quantitative desorption and subsequent measurement by means of atomic spectrometric techniques such as flame atomic absorption spectrometry, electrothermal atomic absorption spectrometry or inductively coupled plasma atomic emission spectrometry/mass spectrometry, among others. Synthesis, purification and types of carbon nanotubes, as well as the diverse chemical and physical strategies for their functionalization are described. Based on 140 references, the performance and general properties of the applications of solid phase extraction based on carbon nanotubes for metal species atomic spectrometric determination are discussed.  相似文献   

5.
光学玻璃中的各种元素对玻璃的光学性能有不同的影响。如加入镉可以提高玻璃折射率;砷的引入能增加玻璃的透光度,含铅玻璃具有低成本、高折射性等优点。但是镉、砷、铅均为有毒元素,玻璃加工和处理过程以及毒废弃物的处理都可能引起水、土壤、大气的污染并给人体带来一定的危害  相似文献   

6.
A speciation procedure for As(III) and As(V) ions in environmental samples has been presented. As(V) was quantitatively recovered on aluminum hydroxide precipitate. After oxidation of As(III) by using dilute KMnO4, the developed coprecipitation was applied to determination of total arsenic. Arsenic(III) was calculated as the difference between the total arsenic content and As(V) content. The determination of arsenic levels was performed by hydride generation atomic absorption spectrometry (HG-AAS). The analytical conditions for the quantitative recoveries of As(V) including pH, amount of aluminum as carrier element and sample volume, etc. on the presented coprecipitation system were investigated. The effects of some alkaline, earth alkaline, metal ions and also some anions were also examined. Preconcentration factor was calculated as 25. The detection limits (LOD) based on three times sigma of the blank (N: 21) for As(V) was 0.012 μg L−1. The satisfactory results for the analysis of arsenic in NIST SRM 2711 Montana soil and LGC 6010 Hard drinking water certified reference materials for the validation of the method was obtained. The presented procedure was successfully applied to real samples including natural waters for arsenic speciation.  相似文献   

7.
Within the last decade, liquid-phase microextraction (LPME) and micro-solid phase extraction (μSPE) approaches have emerged as substitutes for conventional sample processing procedures for trace metal assays within the framework of green chemistry. This review surveys the progress of the state of the art in simplification and automation of microextraction approaches by harnessing to the various generations of flow injection (FI) as a front end to atomic absorption spectrometry (AAS), atomic fluorescence spectrometry (AFS) or inductively coupled plasma atomic emission spectrometry or mass spectrometry (ICP-AES/MS). It highlights the evolution of flow injection analysis and related techniques as vehicles for appropriate sample presentation to the detector and expedient on-line matrix separation and pre-concentration of trace levels of metals in troublesome matrices. Rather than being comprehensive this review is aimed at outlining the pros and cons via representative examples of recent attempts in automating green sample preparation procedures in an FI or sequential injection (SI) mode capitalizing on single-drop microextraction, dispersive liquid-phase microextraction and advanced sorptive materials including carbon and metal oxide nanoparticles, ion imprinted polymers, superparamagnetic nanomaterials and biological/biomass sorbents. Current challenges in the field are identified and the synergetic combination of flow analysis, nanotechnology and metal-tagged biomolecule detection is envisaged.  相似文献   

8.
Water and ‘soft’ extractions (hydroxylammonium hydrochloride, ammonium oxalate and orthophosphoric acid) have been studied and applied to the determination of arsenic species (arsenite, arsenate, monomethylarsonic acid (MMA) and dimethylarsinic acid (DMA)) in three environmental solid reference materials (river sediment, agricultural soil, sewage sludge) certified for their total arsenic content. The analytical method used was ion exchange liquid chromatography coupled on‐line to atomic fluorescence spectroscopy through hydride generation. Very low detection limits for arsenic were obtained, ranging from 0.02 to 0.04 mg kg?1 for all species in all matrices studied. Orthophosphoric acid is the best extractant for sediment (mixed origin) and sludge samples (recent origin) but not for the old formation soil sample, from which arsenic is extracted well only by oxalate. Both inorganic forms (As(III) and As(V)) are significant in all samples, As(V) species being predominant. Moreover, organic forms are found in water extracts of all samples and are more important in the sludge sample. These organic forms are also present in the ‘soft’ extracts of sludge. Microwave‐assisted extraction appears to minimize the risk of a redox interconversion of inorganic arsenic forms. This study points out the necessity of combining direct and sequential extraction procedures to allow for initial arsenic speciation and to elucidate the different mineralogical phases–species associations. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

9.
The paper presents the principles and advantages of a technique combining high performance liquid chromatography and hydride generation atomic absorption spectrometry (HPLC-HGAAS) applied to speciation analysis of inorganic species of arsenic As(III) and As(V) in ground water samples. With separation of the arsenic species on an ion-exchange column in the chromatographic system and their detection by the hydride generation atomic absorption spectrometry, the separation of the analytical signals of the arsenic species was excellent at the limits of determination of 1.5 ng/ml As(III) and 2.2 ng/ml As(V) and RSD of 4.3% and 7.8% for the concentration of 25 ng/ml. The hyphenated technique has been applied for determination of arsenic in polluted ground water in the course of the study on migration of micropollutants. For total arsenic concentration two independent methods: HGICP-OES and HGAAS were used for comparison of results of real samples analysis.  相似文献   

10.
In recent years, knowledge of the different chemical forms of the elements has gained increasing importance. There has been significant progress in methods that hyphenate chromatographic separations with atomic spectrometry. These hyphenated methods can provide the most complete information on the species distribution and even structure. However, they can be lengthy, relatively costly and difficult to bring to the routine. On the other hand, it is important to remember that chromatographic techniques represent only a minor part of the separation procedures available and, in certain cases, the application of basic chemistry to sample treatments can give quantitative information about specific chemical forms. In this sense, non-chromatographic procedures can provide methods that offer sufficient information on the elemental speciation for a series of situations. Moreover, these non-chromatographic strategies can be less time consuming, more cost effective and available, and present competitive limits of detection. Thus, non-chromatographic speciation analysis continues to be a promising research area and has been applied to the development of several methodologies that facilitate this type of analytical approach. In view of their importance, the present work overviews and discusses different non-chromatographic methods as alternatives for the speciation analysis of clinical, environmental and food samples using atomic spectrometry for detection.  相似文献   

11.
Analytical methods for inorganic arsenic in water: a review   总被引:2,自引:0,他引:2  
Hung DQ  Nekrassova O  Compton RG 《Talanta》2004,64(2):269-277
Inorganic arsenic, a term which encompasses both As (III) and As (V) species, constitutes the highest toxicological risk associated with arsenic in water in contrast to the organic arsenic species. Different determination methods of inorganic arsenic have been developed over 40 years providing timely and efficient risk assessments of inorganic arsenic contamination world wide. The current report gives an overview of more than 100 papers, regarding existing methods for analysis of As (III) and As (V) in water, including various spectroscopic, ICP and electrochemical techniques. Recent field portable analytical applications are also reviewed.  相似文献   

12.
A method is described for the determination of inorganic arsenic species and total arsenic in wines by means of hydride generation atomic absorption spectrometry (HGAAS). Simple ethanol evaporation is the only pretreatment procedure proposed for wine samples prior to direct measurement of inorganic arsenic (AsIII) and As(V) species by HGAAS. The total arsenic content is determined after microwave digestion of the wine samples. The optimal parameters for the microwave digestion procedure and the next HGAAS measurement of arsenic are established. The detection limits achieved are 0.1µgL–1 for inorganic and total arsenic determination. The relative standard deviation for both procedures and for ten independent determinations varied between 8 and 15% for arsenic species in the range of 1–30µgL–1. The accuracy of the procedure for total arsenic determination was proved by comparative analysis using electrothermal atomic absorption spectrometry.  相似文献   

13.
An inductively coupled plasma atomic emission spectrometric (ICP-AES) method was developed for speciation and simultaneous determination of Cr and As, since these two analytes are commonly determined in various water samples in order to assess their toxicity. The objective of this research was to study the speciation of Cr(III), Cr(VI) in the presence of As(III) and/or As(V) using solid phase extraction (SPE) and ICP-AES. For these measurements, four spectral lines were used for each analyte with the purpose of selecting the most appropriate for each element. Finally with the use for first time of a cation-exchange column filled with benzosulfonic acid and elution with HCl, the speciation in solutions which contained [Cr(III)?+?Cr(VI)?+?As(V)] and [Cr(III)?+?Cr(VI)?+?As(III)] was examined. It was demonstrated that the separation of the two chromium species is almost quantitative and the simultaneous determination of chromium species and total arsenic analytes is possible, with very good performance characteristics. The estimated limits of detection for Cr(III), Cr(VI), As(III) and/or As(V) were 0.9?µg?L?1, 1.1 µg?L?1, 4.7 µg?L?1 and 4.5 µg?L?1 respectively, the calculated relative standard deviations (RSDs) were 3.8%, 4.1%, 5.2% and 5.1% respectively, and finally the accuracy of the methods was estimated using a certified aqueous reference material and found to be 5.6% and 4.8% for Cr(III) and Cr(VI) respectively. The method was applied to the routine analysis of various water samples.  相似文献   

14.
A new procedure for the speciation analysis of hydride forming elements using GFAAS as detector is proposed. The separation of the species is performed by HPLC and the eluent flow is merged with HCl and NaBH4 solutions moved by peristaltic pumps controlled by a flow injection apparatus. As the species emerges from the column, its respective hydride is formed and carried through the autosampler capillary to an Ir treated graphite tube pre-heated at 300 °C, where it is trapped. After the hydride collection, the autosampler arm is moved from the tube and atomization takes place. The sequence is repeated for the next emerging species. The feasibility of the system was evaluated for the speciation of As (III) and As (V) in waste water samples. The retention times were previously determined using a more concentrated mixed analytical solution and a quartz tube as atomizer. The analytical curves obtained by the proposed procedure showed similar slopes for both species as well as coefficient of regression better than 0.99. Limits of detection were 0.2 ng/mL for both species, 50 times better then the same assembly using a quartz tube atomizer. In the analysis of certified reference materials the sum of the As (III) and As (V) species concentrations were in close agreement with the arsenic concentration certified for total arsenic.  相似文献   

15.
建立了氢化物发生原子荧光法测定聚氯化铝中砷含量的检测方法。将聚氯化铝样品用硫酸溶解,蒸至近干,用氢化物发生原子荧光法测定其中的砷含量。在最佳测定条件下,砷的质量浓度在0~10.0μg/L范围内与荧光强度呈良好的线性关系,相关系数r=0.999 3,砷的检出限为0.03μg/g,样品加标回收率为82.5%~90.0%,测定结果的相对标准偏差为1.5%~1.9%。该法具有快速、准确、灵敏度高等优点。  相似文献   

16.
A fast, sensitive and simple non-chromatographic analytical method was developed for the speciation analysis of toxic arsenic species in cereal samples, namely rice and wheat semolina. An ultrasound-assisted extraction of the toxic arsenic species was performed with 1 mol L− 1 H3PO4 and 0.1% (m/v) Triton XT-114. After extraction, As(III), As(V), dimethylarsinic acid (DMA) and monomethylarsonic acid (MMA) concentrations were determined by hydride generation atomic fluorescence spectrometry using a series of proportional equations corresponding to four different experimental reduction conditions. The detection limits of the method were 1.3, 0.9, 1.5 and 0.6 ng g− 1 for As(III), As(V), DMA and MMA, respectively, expressed in terms of sample dry weight. Recoveries were always greater than 90%, and no species interconversion occurred. The speciation analysis of a rice flour reference material certified for total arsenic led to coherent results, which were also in agreement with other speciation studies made on the same certified reference material.  相似文献   

17.
An analytical procedure for selenium speciation of analysis of selenourea (SeU), selenoethionine (SeE), selenomethionine (SeM), Se(VI), Se(IV), dimethylselenide (dMeSe) and dimethyldiselenide (dMedSe) was developed, based on two complementary liquid chromatography (LC) techniques coupled with inductively coupled plasma-mass spectrometry (ICP-MS). Specifically, strong anion exchange (SAX) chromatography coupled with ICP-MS was used for the separation and quantification of all the earlier mentioned Se compounds, except for the two methyl selenides, which could be separated and determined by reversed phase chromatography coupled with ICP-MS. This procedure was applied to a soil sample from the warm springs area of Thermopyles (Greece). For leaching the Se species from the soil sample, four extraction methods, using water at ambient temperature, hot water, methanol and 0.5 M HCl, were tested for their efficiency of extracting the different Se species. The speciation results obtained by the LC-ICP-MS methods were compared with those obtained by voltammetric techniques. The determination of total selenium in the sample was achieved by graphite furnace atomic absorption spectrometry, as well as by ICP-atomic emission spectrometry, after suitable digestion of the sediment sample.  相似文献   

18.
地球化学样品中钒的测定方法主要有原子吸收光谱法、等离子体发射光谱法(ICP-AES)、电感耦合等离子体质谱法(ICP-MS)和X射线荧光光谱法.选用国家一级标样,分别用4种方法测定样品含量值,依次对方法检出限、准确度、精密度、加标回收率作比较.经对比,4种方法测定值与推荐值都基本吻合.等离子体发射光谱法检出限低,线性范围更宽,准确度与精密度更好,更适用于地球化学样品中钒批量的测试.  相似文献   

19.
A simple procedure was developed for the speciation of inorganic arsenic by electrochemical hydride generation atomic absorption spectrometry (EcHG–AAS), without pre-reduction of As(V). Glassy carbon was selected as cathode material in the flow cell. An optimum catholyte concentration for simultaneous generation of arsine from As(III) and As(V) was 0.06 mol l−1 H2SO4. Under the optimized conditions, adequate sensitivity and difference in ratio of slopes of the calibration curves for As(III) and As(V) can be achieved at the electrolytic currents of 0.6 and 1 A. The speciation of inorganic arsenic can be performed by controlling the electrolytic currents, and the concentration of As(III) and As(V) in the sample can be calculated according to the equations of absorbance additivity obtained at two selected electrolytic currents. The calibration curves were linear up to 50 ng ml−1 for both As(III) and As(V) at 0.6 and 1 A. The detection limits of the method were 0.2 and 0.5 ng ml−1 for As(III) and As(V) at 0.6 A, respectively. The relative standard deviations were of 2.1% for 20 ng ml−1 As(III) and 2.5% for 20 ng ml−1 As(V). The method was validated by the analysis of human hair certified reference material and successfully applied to speciation of soluble inorganic arsenic in Chinese medicine.  相似文献   

20.
The speciation of tellurium was carried out using atomic fluorescence spectrometry as an element‐specific detector in hybridization with liquid chromatography and hydride generation. Good resolution could be obtained by anion‐exchange chromatography with complexing agents, using a mobile phase with 8 mM EDTA and 2 mM potassium hydrogenphthalate. Analysis time was less than 6 min. Calibration graphs were linear between 2 and 100 µg l?1. Detection limits were 0.6 µg l?1 and 0.7 µg l?1 for tellurium(VI) and tellurium(IV) respectively. The method was applied to the speciation of tellurium in drinking water and wastewater samples from different metallurgical industries. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号