共查询到20条相似文献,搜索用时 0 毫秒
1.
Matrix-assisted laser desorption ionization (MALDI) time of flight mass spectrometry was used to identify shrimp at the species level using commercial mass spectral fingerprint matching software (Bruker Biotyper). In the first step, a mass spectrum reference database was constructed from the analysis of six commercially important shrimp species: Litopenaeus setiferus, Farfantepenaeus aztecus, Sicyonia brevirostris, Pleoticus robustus, Pandalopsis dispar and Pandalus platyceros. This step required a desalting procedure for optimum performance. In the second step, the reference database was tested using 74 unknown shrimp samples from these six species. Correct identification was achieved for 72 of 74 samples (97%): 72 samples were identified at the species level and 2 samples were identified at the genus level using the manufacturer's log score specifications. The MALDI fingerprinting method for the identification of shrimp species was found to be reproducible and accurate with rapid analysis. 相似文献
2.
Desorption electrospray ionization ‐ orbitrap mass spectrometry of synthetic polymers and copolymers
Manel Friia Vronique Legros Jeanine Tortajada William Buchmann 《Journal of mass spectrometry : JMS》2012,47(8):1023-1033
Desorption ElectroSpray Ionization (DESI) ‐ Orbitrap Mass Spectrometry (MS) was evaluated as a new tool for the characterization of various industrial synthetic polymers (poly(ethylene glycol), poly(propylene glycol), poly(methylmethacrylate), poly(dimethylsiloxane)) and copolymers, with masses ranging from 500 g.mol−1 up to more than 20 000 g.mol−1. Satisfying results in terms of signal stability and sensitivity were obtained from hydrophobic surfaces (HTC Prosolia) with a mixture water/methanol (10/90) as spray solvent in the presence of sodium salt. Taking into account the formation of multiplied charged species by DESI‐MS, a strategy based on the use of a deconvolution software followed by the automatic assignment of the ions was described allowing the rapid determination of Mn, Mw and PDI values. DESI‐Orbitrap MS results were compared to those obtained from matrix‐assisted laser desorption/ionization‐ time‐of‐flight MS and gel permeation chromatography. An application of DESI‐Orbitrap MS for the detection and identification of polymers directly from cosmetics was described. Copyright © 2012 John Wiley & Sons, Ltd. 相似文献
3.
Polymer manufacturers add antioxidants, waxes, dyes, and other materials to enhance polymer utility or processing. Numerous analytical methods are available to characterize various chemical aspects of polymers including methods interfaced with mass spectrometry (MS) such as pyrolysis (Py), gas chromatography (GC), liquid chromatography (LC), and thermogravimetric analysis (TGA). Current methods work well, but because of the necessity of extraction, chromatography, or thermal methods, most are too time consuming for high throughput analyses which might be necessary in, for example, regulatory laboratories. Here we discuss three MS methods for rapid analysis of polymers; multi-sample MALDI MS which allows rapid analysis of low molecular weight polymers, atmospheric pressure (AP) solids analysis probe MS for direct ambient additives analysis, and APPy MS for polymer identification. The latter methods provide information regardless of the composition or molecular weight of the polymeric material. 相似文献
4.
With the invention of electrospray ionization and matrix-assisted laser desorption/ionization, scientists employing modern mass spectrometry naturally face new challenges with respect to background interferences and contaminants that might not play a significant role in traditional or other analytical techniques. Efforts to continuously minimize sample volumes and measurable concentrations increase the need to understand where these interferences come from, how they can be identified, and if they can be eliminated. Knowledge of identity enables their use as internal calibrants for accurate mass measurements. This review/tutorial summarizes current literature on reported contaminants and introduces a number of novel interferences that have been observed and identified in our laboratories over the past decade. These include both compounds of proteinaceous and non-proteinaceous nature. In the supplemental data a spreadsheet is provided that contains a searchable ion list of all compounds identified to date. 相似文献
5.
Dong Cao Huogao Huang Ming Hu Lin Cui Fanglan Geng Ziyu Rao Hongyun Niu Yaqi Cai Yuehui Kang 《Analytica chimica acta》2015
Natural organic matter (NOM) is a complex and non-uniform mixture of organic compounds which plays an important role in environmental processes. Due to the complexity, it is challenging to obtain fully detailed structural information about NOM. Although Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) has been demonstrated to be a powerful tool for providing molecular information about NOM, multiple ionization methods are needed for comprehensive characterization of NOM at the molecular level considering the ionizing selectivity of different ionization methods. This paper reports the first use of matrix assisted laser desorption/ionization (MALDI) method coupled with FT-ICR-MS for molecular characterization of NOM within a mass range of 200–800 Da. The mass spectral data obtained by MALDI were systematically compared with data generated by electrospray ionization (ESI). It showed that complementary molecular information about NOM which could not be detected by ESI, were provided by MALDI. More unsaturated and aromatic constituents of NOM with lower O/C ratio (O/C ratio < 0.5) were preferentially ionized in MALDI negative mode, whereas more polar constituents of NOM with higher O/C ratio were preferentially ionized in ESI negative mode. Molecular anions of NOM appearing at even m/z in MALDI negative ion mode were detected. The results show that NOM molecules with aromatic structures, moderate O/C ratio (0.7 > O/C ratio > 0.25) and lower H/C ratio were liable to form molecular anions at even m/z, whereas those with higher H/C ratio are more likely to form deprotonated ions at odd m/z. It is speculated that almost half of the NOM molecules identified by MALDI may be aromatic or condensed aromatic compounds with special groups which are liable to absorb electron from other molecules to generate free radical anions during MALDI ionization. 相似文献
6.
N-linked oligosaccharide standards obtained from commercial sources were derivatized with phenylhydrazine (PHN) and analyzed by on-line reversed-phase high performance liquid chromatography (HPLC)/electrospray ionization mass spectrometry (ESI-MS). This procedure was then applied to mixtures of N-glycans enzymatically released from hen ovalbumin. Under ESI-MS conditions, phenylhydrazones of asialylated oligosaccharide standards and ovalbumin glycans produced mainly [M + 2H]2+ molecular ions at low cone voltage values, while minimal fragmentation was observed. Reversed-phase HPLC/ESI-MS total and selected ion chromatograms obtained for derivatized N-glycans from ovalbumin showed partial but useful separation. Overall glycan profiles obtained by ESI-MS were compared with results obtained by matrix-assisted laser desorption/ionization (MALDI)-MS. Qualitatively, profiles were similar from one technique to the other in terms of relative abundance of glycans versus composition. Post-source decay (PSD) analysis of the [M + Na]+ ions of PHN-glycans showed dominant B, C and internal B/Y, C/Y cleavages. These patterns were helpful in relating fragmentation to proposed structures. Cross-ring cleavage fragment ions (A-type) were also observed in most cases. The PHN derivatization method is fast and simple. It produces abundant parent ions in both MALDI-MS and ESI-MS, while avoiding the presence of salt contaminants during the labeling procedure. 相似文献
7.
This report focuses on the heterogeneous distribution of small molecules (e.g. metabolites) within dry deposits of suspensions and solutions of inorganic and organic compounds with implications for chemical analysis of small molecules by laser desorption/ionization (LDI) mass spectrometry (MS). Taking advantage of the imaging capabilities of a modern mass spectrometer, we have investigated the occurrence of “coffee rings” in matrix-assisted laser desorption/ionization (MALDI) and surface-assisted laser desorption/ionization (SALDI) sample spots. It is seen that the “coffee-ring effect” in MALDI/SALDI samples can be both beneficial and disadvantageous. For example, formation of the coffee rings gives rise to heterogeneous distribution of analytes and matrices, thus compromising analytical performance and reproducibility of the mass spectrometric analysis. On the other hand, the coffee-ring effect can also be advantageous because it enables partial separation of analytes from some of the interfering molecules present in the sample. We report a “hidden coffee-ring effect” where under certain conditions the sample/matrix deposit appears relatively homogeneous when inspected by optical microscopy. Even in such cases, hidden coffee rings can still be found by implementing the MALDI-MS imaging technique. We have also found that to some extent, the coffee-ring effect can be suppressed during SALDI sample preparation. 相似文献
8.
We have developed surface-assisted laser desorption/ionization mass spectrometry using zinc oxide (ZnO) nanoparticles with anisotropic shapes (ZnO-SALDI-MS). The mass spectra showed low background noises in the low m/z, i.e. less than 500 u region. Thus, we succeeded in SALDI ionization on low molecular weight organic compounds, such as verapamil hydrochloride, testosterone, and polypropylene glycol (PPG) (average molecular weight 400) without using a liquid matrix or buffers such as citric acids. In addition, we found that ZnO-SALDI has advantages in post-source decay (PSD) analysis and produced a simple mass spectrum for phospholipids. The ZnO-SALDI spectra for synthetic polymers of polyethylene glycol (PEG), polystyrene (PS) and polymethylmethacrylate (PMMA) showed the sensitivity and molecular weight distribution to be comparable to matrix-assisted laser desorption/ionization (MALDI) spectra with a 2,5-dihydroxybenzoic acid (DHB) matrix. ZnO-SALDI shows good performance for synthetic polymers as well as low molecular weight organic compounds. 相似文献
9.
Zarei M Kirsch S Müthing J Bindila L Peter-Katalinić J 《Analytical and bioanalytical chemistry》2008,391(1):289-297
The coupling of nano high-performance liquid chromatography (nanoHPLC) with matrix-assisted laser desorption/ionization (MALDI)
mass spectrometry (MS) via an automatic spotting roboter was developed and adapted for the first time for the analysis of
complex mixtures of glycosphingolipids (GSLs). The 2,5-dihydroxybenzoic acid and 6-azo-2-thiothymine matrix systems were adjusted
to concurrently meet the requirements for reproducible and homogeneous crystal formation with the liquid chromatography (LC)
eluent under the variable LC solvent composition over the course gradient and high ionization efficiency of the GSL species,
without the need for recrystallization. Precise adjustment of the automatic spotting parameters in terms of matrix flow rate,
on-tip collection time of the matrix/LC eluent solution and the matrix spotting mode, i.e., continuous and discontinuous,
was accomplished to collect individually nanoHPLC-separated species within distinct spots and consequently recover by MALDI
MS screening all major and minor GSL species in the mixtures. The nanoHPLC/MALDI MS coupling protocol was developed and applied
to a mixture of neutral GSLs purified from human erythrocytes and a monosialoganglioside mixture expressed by the murine MDAY-D2
cell line. Additionally, on-line nanoHPLC/MALDI doping with lithium cations of individually separated neutral GSLs was introduced
to enhance data interpretation of the GSL MS pattern, while preserving the same level of information and ultimately to enhance
structural assignment of components of interest. The method is demonstrated to be highly sensitive, reaching the low femtomole
level of detection of individual GSL species and is highlighted as a versatile analytical tool for glycolipidomic studies.
Figure
Automatic LC/MALDI MS profiling of glycosphingolipids
Mostafa Zarei and Stephan Kirsch contributed equally to this work. 相似文献
10.
Synthesis, characterization and biodegradable studies of 1,3-propanediol based polyesters 总被引:1,自引:0,他引:1
A series of biodegradable polyesters were synthesized from dicarboxylic acids and 1,3-propanediol catalyzed by transestrification polycondensation reaction in the bulk. The structure, average molecular weights and physical properties of the resulting aliphatic polyesters were characterized by 1H NMR, FT-IR, solution viscosity, GPC, DSC and TGA. Homopolyesters show higher degree of crystallinity, melting and thermal stability in comparison to copolyesters. The biodegradability of the polyesters was determined by monitoring the normalized weight loss of polyester films with time in phosphate buffer (pH 7.2) without and with Rhizopus delemar lipase at 37 °C. The rate of enzymatic degradation of homopolyesters follows the path PPSu > PPAd > PPSe. PPSe did not show significant weight loss in presence of enzyme which may be due to its highest degree of crystallinity and melting point compared to the PPSu, PPAd and copolyesters. In the soil burial degradation polyester sample showed severe surface degradation by the attack of microorganism. 相似文献
11.
The synthesis of branched poly(ethylene glycol) (PEG) derivatives, namely star PEG and dendronized PEG, can be challenging and their purity can be difficult to ascertain using traditional techniques, such as NMR and GPC. Herein, the detailed characterization of these branched PEGs using MALDI-ToF MS was investigated in order to confirm their structural purity. In this light, mass spectrometry offers a number of advantages for polymer characterization, including the ability to get detailed structural data, such as end group masses, from microgram-scale samples. In addition, the ability to rapidly acquire data from crude reaction aliquots makes MALDI-ToF MS ideal for monitoring end group transformations. 相似文献
12.
13.
Daniel JM Laiko VV Doroshenko VM Zenobi R 《Analytical and bioanalytical chemistry》2005,383(6):895-902
Two different strategies for coupling liquid chromatography with atmospheric pressure matrix assisted laser desorption/ionization
(AP MALDI) are presented. The first method is flow-injection liquid AP UV-MALDI. Compared with previous similar research,
the detection limit was improved 10 times to 8.3 fmol using a solution of 50 nM peptide with 25 mM α-cyano-4-hydroxycinnamic acid. The applicability of this method to measure oligosaccharides, actinomycin antibiotics, antibiotics,
phosphopeptides, and proteins is demonstrated. The upper mass limit achieved with the current instrumentation is 6,500 Da
(doubly charged cytochrome c). The feasibility of a second strategy based on single-droplet IR AP MALDI is demonstrated here. Aqueous peptide solutions
were successfully measured by this method. 相似文献
14.
Aminoglycoside phosphotransferase 3′IIIa (APH3′IIIa) is a bacterial enzyme involved in antibiotic resistance through phosphorylation of aminoglycosides, which can potentially be overcome by co-administration of an APH3′IIIa inhibitor with the antibiotic. Current assay methods for discovery of APH3′IIIa inhibitors suffer from low specificity and high false positive/negative hit rates. Here, we describe a method for screening APH3′IIIa inhibitors based on direct detection of kanamycin A phosphorylation using MALDI-MS/MS, which is more rapid than conventional assays and does not require secondary assays or sample cleanup. The MALDI-MS/MS assay operates at an ionic strength of 45 mM and co-factors can be utilized at near-physiological levels for optimal enzyme activity. Detection via MALDI-MS/MS allowed for improved reproducibility when compared to ESI-MS/MS. Furthermore, the use of MS/MS provided better signal-to-noise ratios relative to MS alone on the MALDI instrument. The assay was validated via generation of Z′-factors, with values of 0.78 and 0.56 in the absence and presence of 0.2% DMSO, respectively. The assay was used to screen a kinase directed library of >200 compounds, assayed as 21 mixtures of 10 compounds each. Five novel synthetic inhibitors were identified following mixture deconvolution. Inhibition constants were obtained for the aforementioned inhibitors using the MALDI-MS/MS assay, revealing several low to mid micromolar “hits”, and highlighting the quantitative nature of the assay. 相似文献
15.
Boronate affinity materials have attracted increasing attentions as sample enrichment platforms for glycoproteomic analysis in recent years. However, most of the boronate affinity materials that have already employed for proteomic analysis are suffering from apparent disadvantages, such as alkaline pH for binding, weak affinity, and relatively poor selectivity. Benzoboroxoles are a unique class of boronic acids which have showed excellent binding properties for the recognition of cis-diol-containing compounds. Recently, a 3-carboxy-benzoboroxole-functionalized monolithic column had been reported and it had exhibited the best selectivity and affinity as well as the lowest binding pH among all reported boronate affinity monolithic columns. In this study, an off-line hyphenation of this boronate affinity monolithic column-based extraction with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) was developed and the powerfulness of this hyphenated approach in the analysis of glycoproteins and glycopeptides in complex samples was investigated. The approach was first applied to the analysis of glycopeptides in the tryptic digest of horseradish peroxidase (HRP). Totally 22 glycopeptides were identified. To the best of our knowledge, this is the best performance among all the boronic acid-functionalized materials. We further employed this approach to the analysis of intact proteins in human saliva. Totally 6 intact glycoproteins were successfully identified. As comparison, when the samples were analyzed without extraction, only a few glycopeptides were identified from the tryptic digest of HRP while no glycoproteins were found from the saliva samples. 相似文献
16.
This review highlights recent advances in the application of electrospray ionisation and matrix-assisted laser desorption/ionisation mass spectrometry (MS) to study enzymatic reactions. Several assay schemes for different fields of application are presented. The employment of MS as a means of detection in pre-steady-state kinetic studies by rapid-mixing direct analysis and rapid-mixing quench flow techniques is discussed. Several steady-state kinetic studies of a broad range of different enzymatic systems are presented as well as enzyme inhibition studies for various target enzymes. As a promising new development multiplex assays, which monitor the conversion of several substrates simultaneously in one experiment, are described. This assay type has been used for competition studies, enzymatic activity screenings and for diagnostic purposes in clinical chemistry. Generally, it can be concluded that mass spectrometry offers an intriguing alternative as detection methodology in enzymatic bioassays. Its applicability for the monitoring the conversion of naturally occurring substrates and its overall versatility make MS an especially promising tool for the study of enzyme-catalysed processes. 相似文献
17.
T. Ranganathan Joseph Zilberman Phillip R. Westmoreland E. Bryan Coughlin 《Polymer Degradation and Stability》2008,93(6):1059-1066
The thermal degradation behavior of novel ultra-fire-resistant polymers and copolymers containing deoxybenzoin units in the backbone was studied by pyrolysis-gas chromatography/mass spectrometry (Py-GC/MS). The polymers were synthesized by the polycondensation of 4,4′-bishydroxydeoxybenzoin (BHDB) with isophthaloyl chloride (to give polyarylates), phenylphosphonic dichloride (to give polyphosphonates), and their mixtures (to give poly(arylate-co-phosphonate) copolymers). The thermal decomposition, under nitrogen conditions, of BHDB-polyarylate was characterized by a simultaneous degradation of both the bisphenolic (deoxybenzoin) and isophthalate sub-units, whereas a three-step decomposition phenomenon was observed for the BHDB-polyphosphonate. BHDB-polymers containing phosphonate groups in the backbone did not show any phosphorus-based volatile decomposition products, whereas the corresponding bisphenol A-based polyphosphonates released volatile decomposition products comprised mainly of phosphorus-containing compounds. 相似文献
18.
V. G. Zaikin R. S. Borisov N. Yu. Polovkov V. V. Lobodin 《Russian Chemical Bulletin》2007,56(7):1369-1373
Synthetic copolyamides based on aliphatic diamines (1,3-propanediamine and 1,4-butanediamine) and dichlorides of aliphatic
carboxylic acids (adipic and sebacic acid dichlorides) were investigated using time-of-flight matrix assisted laser desorption/ionization
mass spectrometry. Their mass spectra showed peaks for cationized (Na+ and K+) and protonated (less intense peaks) oligomers with NH2-NH2, NH2-COOH, or COOH-COOH end groups. No cyclic oligomers were detected in the samples. The compositions of oligomers were determined,
and the relative reactivities of homologous comonomers in polycondensation were estimated.
Published in Russian in Izvestiya Akademii Nauk. Seriya Khimicheskaya, No. 7, pp. 1320–1324, July, 2007. 相似文献
19.
Lou X van Buijtenen J Bastiaansen JJ de Waal BF Langeveld BM van Dongen JL 《Journal of mass spectrometry : JMS》2005,40(5):654-660
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) was applied to the analysis of Ru(OCOCF(3))(2)(CO)(PPh(3))(2), Ru(OCOC(3)F(7))(2)(CO)(PPh(3))(2), Ir(tBuppy)(3) and Ir(ppy)(2)(acac) complexes. A troublesome problem in the MALDI-TOFMS characterization of these metal complexes is the possible replacement of complex ligands by matrix. In this contribution, 10 matrices, ranging from acidic to basic, were investigated: alpha-cyano-4-hydroxycinnamic acid (CHCA), 2,5-dihydroxybenzoic acid (DHB), sinapinic acid (SA), dithranol, 2,4,6-trihydroxyactophenone (THAP), 6-azo-2-thiothymine (ATT), norharman, 2-[(2E)-3-(4-tert-butylphenyl)-2-methylprop-2-enylidene]malononitrile (DCTB), 4-nitroaniline (NA) and 2-amino-5-nitrophyridine (ANP). With most of the matrices, including the neutral and basic ones, matrix substitution of ligand could clearly be detected. Based on the experimental results, possible mechanisms of matrix substitution were discussed. It was demonstrated that the ligand exchange process might also occur through the gas-phase reactions initiated by laser shots. Among the matrices tested, DCTB was found to be the best one for the complexes that are prone to ligand exchange by matrix. 相似文献
20.
The effectiveness of a novel binary matrix composed of 1,8-bis(dimethylamino)naphthalene (DMAN; proton sponge) and 9-aminoacridine (9AA) for the direct lipid analysis of whole bacterial cells by matrix assisted laser desorption ionization mass spectrometry (MALDI MS) is demonstrated. Deprotonated analyte signals nearly free of matrix-related ions were observed in negative ion mode. The effect of the most important factors (laser energy, pulse voltage, DMAN/9AA ratio, analyte/matrix ratio) was investigated using a Box–Behnken response surface design followed by multi-response optimization in order to simultaneously maximize signal-to-noise (S/N) ratio and resolution. The chemical surface composition of single or mixed matrices was explored by X-ray photoelectron spectroscopy (XPS). Moreover, XPS imaging was used to map the spatial distribution of a model phospholipid in single or binary matrices. 相似文献