首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A single-step extraction method and thin-layer identification techniques capable of testing a wide variety of drugs of abuse are presented. These techniques are well suited for large and/or small drug programs involved in urine testing because they provide substantial economic benefits and improve clinical functioning. The drugs are absorbed on a 6 X 6 cm piece of paper loaded with cation-exchange resin and then eluted from the paper at pH 10.1 using ammonium chloride-ammonia buffer. The simultaneous thin-layer detection of sedatives, hypnotics, narcotic analgesics, central nervous system stimulants and miscellaneous drugs is accomplished by spotting the solution of extracted residue on a 20 X 20 cm Gelman pre-coated silica gel glass microfiber sheet (ITLC Type SA). A two-stage solvent system is used in order to obtain a chromatogram with optimum separation of a wide range of drugs. This system can separate methadone and/or cocaine from propoxyphene, methaqualone, methylphenidate, pentazocine, pipradrol, Doxepin, chlorpromazine, phenazocine, naloxone, naltrexone, imipramine and trimeprazine; amphetamine from phenylpropanolamine and dimethyltryptamine; codeine from dextromethorphan; methamphetamine from dimethyltryptamine, etc. Different detection reagents are then applied in succession to different marked areas of the developed chromatogram. This elegant method of extraction and spraying has enabled us to detect morphine base at a sensitivity level of 0.15 mug/ml, amphetamine sulfate at 1.0 mug/ml, methamphetamine hydrochloride at 0.5 mug/ml, phenmetrazine hydrochloride at 0.5 mug/ml, codeine phosphate at 0.5 mug/ml, methadone hydrochloride at 1.0 mug/ml, secobarbital at 0.36 mug/ml and phenobarbital at 0.5 mug/ml in urine. The minimum volume of urine needed to achieve these sensitivities is 20 ml. The cost of analysis per urine specimen using these techniques for concomitant screening of these drugs is less than US$ 1.  相似文献   

2.
The sensitivity achieved by the described thin-layer chromatographic (TLC) method greatly exceeds that of previously published TLC methods for the determination of cocaine and its principal metabolite, benzoylecgonine, in urine. Sensitivity for cocaine and benzoylecgonine approaches 0.1 and 0.25 mug/ml, respectively, for a 5.0-ml specimen. A simple extraction with a mixed organic solvent provides the basic mechanism for isolating the drugs from biologic specimens. Cocaine and its metabolites are stable in sulfuric acid solutions but labile in aqueous media containing certain other inorganic and organic acids; therefore, an emphasis on the utilization of sulfuric acid solutions is employed throughout the procedure. An evaluation of sensitivities achieved for cocaine and benzoylecgonine by various detection reagents is presented. The technique is applicable to drug screening programs.  相似文献   

3.
Thin-layer chromatographic procedures are presented for the positive identification of methodone, primary metabolite of methodone (2-ethylidine-1,5-dimethyl-3,3-diphenylpyrrolidine), propoxyphene, norpropoxyphene, cocaine, benzoylecgonine, methoqualone, and phencyclidine from urine specimens. Initial screening of specimens is done by developing plates in ethyl acetate-methanol-diethylamine (90:10:1.6). Samples screened positive are confirmed in methylene chloride-methyl ethyl ketone-concentrated ammonium hydroxide (74:25:0.8), depending on the drug(s) indicated by the screening procedure. The method is quite sensitive, detecting most of the listed drugs at levels of 1.0 mug/ml or less.  相似文献   

4.
Today, immunoassays and several chromatographic methods are in use for drug screening in clinical and forensic toxicology and in doping control. For further proof of the authors’ new metabolite-based liquid chromatography-mass spectrometry (LC-MSn) screening concept, the detectability of drugs of abuse and their metabolites using this screening approach was studied. As previously reported, the corresponding reference library was built up with MS2 and MS3 wideband spectra using a LXQ linear ion trap with electrospray ionization in the positive mode and full scan information-dependent acquisition. In addition to the parent drug spectra recorded in methanolic solution, metabolite spectra were identified after protein precipitation of urine from rats after administration of the corresponding drugs and added to the library. This consists now of data of over 900 parent compounds, including 87 drugs of abuse, and of over 2,300 metabolites and artifacts, among them 436 of drugs of abuse. Recovery, process efficiency, matrix effects, and limits of detection for selected drugs of abuse were determined using spiked human urine, and the resulting data have been acceptable. Using two automatic data evaluation tools (ToxID and SmileMS), the intake of 54 of the studied drugs of abuse could be confirmed in urine samples of drug users after protein precipitation and LC separation. The following drugs classes were covered: stimulants, designer drugs, hallucinogens, (synthetic) cannabinoids, opioids, and selected benzodiazepines. The presented LC-MSn method complements the well-established gas chromatography-mass spectroscopy procedure in the authors’ laboratory.  相似文献   

5.
Ellaithy MM  Volke J  Manousek O 《Talanta》1977,24(2):137-140
A differential pulse polarographic method has been applied to the determination of diazepam, oxazepam, nitrazepam and flurazepam down to 2 x 10(-7)M (0.14 mug/ml). The method can also be used with biological materials such as urine, without prior extraction. Only a 2-ml volume of urine is necessary.  相似文献   

6.
A rapid, sensitive and specific high-performance liquid chromatographic (HPLC) assay was developed for the determination of amdinocillin (formerly mecillinam) in human plasma and urine. The assay is performed by direct injection of a plasma protein-free supernatant or a dilution of urine. A 10 micrometer muBondapak phenyl column with an eluting solvent of water--methanol--1 M phosphate buffer, pH 7 (70:30:0.5) was used, with UV detection of the effluent at 220 nm. Azidocillin potassium salt [potassium-6-(D-(-)-alpha-azidophenyacetamido)-penicillanate] was used as the internal standard and quantitation was based on peak height ratio of amdinocillin to that of the internal standard. The assay has a recovery of 74.4 +/- 6.3% (S.D.) in the concentration ranges of 0.1-20 microgram per 0.2 ml of plasma with a limit of detection equivalent to 0.5 microgram/ml plasma. The urine assay was validated over a concentration range of 0.025-5 mg/ml of urine, and has a limit of detection of 0.025 mg/ml (25 microgram/ml) using a 0.1-ml urine specimen per assay. The assay was applied to the determination of plasma and urine concentrations of amdinocillin following intravenous administration of a 10 mg/kg dose of amdinocillin to two human subjects. The HPLC and microbiological assays were shown to correlate well for these samples.  相似文献   

7.
A rapid gas chromatographic method is described for the determination of chlorophenoxyisobutyric acid (the active metabolite of clofibrate) in plasma and urine. The assay involves an extraction into toluene and back-extraction of the chlorophenoxyisobutyric acid and the internal standard (2-naphthoic acid) into the methylating reagent (trimethylanilinium hydroxide). Concentrations of 1 mug/ml in plasma and urine can easily be measured; the precision of the method is 3.3 +/- 0.7% for plasma and 2.7 +/- 0.4% for urine. There is no interference from endogenous compounds or from drugs commonly prescribed together with clofibrate.  相似文献   

8.
A gas chromatographic method is presented for the detection of beta-phenethylbiguanide (PEBG) and its metabolite, p-hydroxy-beta-phenethylbiguanide (p-OHPEBG). The procedure is applicable for the determination of the drug and its metabolite in the serum and urine of rats. The detection limit is 0.2 mug PEBG and 0.5 mug p-OH PEBG per ml of serum or urine. A time course study of blood concentration and elimination rate following intraperitoneal injection of 100 mg/kg of PEBG to normal rats was performed. Beta-PEBG was found to be present in the blood and the urine, p-OH PEBG was only detected in the urine. Twenty-four hours following intraperitoneal injection, the urine contained 32% of the administered dose, 20% as unaltered PEBG and 12% as p-OH PEBG.  相似文献   

9.
Borissova R  Koeva M  Topalova E 《Talanta》1975,22(10-11):791-796
A method for theoretical estimation of the detection limits of spectrophotometric reagents is reported. The concentration limits of Beer's law when p-dimethylaminobenzilidenerhodanine is used for determination of silver and palladium are defined on the basis of the stability constants. Conditions for determination of 2-10mug, of Ag per 25ml and 1-5mug of Pd per 25ml with standard deviation 0.03mug per 25 ml are proposed.  相似文献   

10.
高吭  刘雅珣  柯威  刘凯  倪浏阳  陶涛 《色谱》2020,38(11):1348-1354
公安机关用胶体金尿检法对海洛因滥用者的检测常常受到阿片类镇咳药的干扰,使用传统液-液提取法进行实验室检验,操作效率低,灵敏度不高,无法满足公安机关打击涉毒案件的需要。为此,该研究建立了尿液中吗啡、O 6 -单乙酰吗啡、可待因和乙酰可待因4种阿片类物质的固相萃取和衍生化技术结合气相色谱-质谱联用(GC-MS)同时检测方法。尿样用磷酸盐缓冲液调节至pH=6后,经MCX固相萃取柱净化,用N -甲基-N -(三甲基硅烷基)三氟乙酰胺(MSTFA)对吗啡、O 6 -单乙酰吗啡、可待因进行衍生化,供GC-MS检测。考察了上样和洗脱流速、淋洗液中甲酸体积分数、洗脱液中氨水体积分数、3%(v/v)甲酸甲醇淋洗液体积和固相萃取柱吹干时间对萃取效果的影响。确定上样和洗脱流速1.0 mL/min,淋洗液中甲酸体积分数3%,洗脱液中氨水体积分数5%,3%(v/v)甲酸甲醇淋洗液体积1 mL,吹干时间1 min为最佳条件。在此条件下,4种阿片类物质在0.02~0.8 μg/mL范围内线性关系良好(r 2 ≥0.998),检出限(LOD)为0.0016~0.0039 μg/mL,定量限(LOQ)为0.0054~0.0128 μg/mL,当标准添加水平为0.02、0.1、0.2 μg/mL时,回收率为93.0%~110.3%。该方法结合自动化技术,对固相萃取条件精确控制,操作简便、快速、灵敏、准确,适合尿液中吗啡等4种阿片类物质快速测定,可用于海洛因吸食者的大规模监控,并能准确排除因服用含阿片类镇咳药导致的吗啡胶体金尿检假阳性。  相似文献   

11.
A sensitive and selective high-performance liquid chromatography method has been developed for the determination of the new monocyclic beta-lactam antibiotic carumonam in plasma and urine. The method for plasma involves protein precipitation with acetonitrile and removal of lipids with dichloromethane; urine is diluted with buffer. Separation and quantification are achieved using a mobile phase based on either ion-suppression or ion-pair chromatography on a reversed-phase column with UV detection. The limit of determination is 0.5 micrograms/ml plasma, using a 0.5-ml specimen, and 25 micrograms/ml urine, using a 50-microliter specimen. The inter-assay reproducibility is generally better than 4% when an internal standard is used. Since beta-lactam antibiotics may degrade on storage, close attention must be paid to the stability of these drugs in biological fluids; novel measures to prevent degradation on storage are described. The assay has been successfully applied to the analysis of several thousand samples from pharmacokinetic studies, including a study involving patients with impaired renal function.  相似文献   

12.
A simple and rapid method for the identification and quantitation of morphine in urine samples is described. The procedure, which involves conversion of the drug a fluorescent product followed by liquid chromatography, is shown to be highly sensitive and specific. Levels down to 0.01 mug/ml of morphine can be quantitatively detected in urine. A large number of drugs have been tested and shown not to interfere.  相似文献   

13.
Lan L  Hu B  Yu C 《Journal of chromatography. A》2010,1217(45):7003-7009
An organic-inorganic hybrid titania-hydroxy-terminated silicone oil (titania-OH-TSO) stir bar coating was prepared by sol-gel method. The extraction performance of titania-OH-TSO coated stir bar was evaluated and compared with poly(dimethysiloxane) (PDMS), poly(dimethysiloxane)-divinylbenzene (PDMS-DVB), poly(dimethysiloxane)-β-cyclodextrin (PDMS-β-CD) and C(18) coated stir bar with five polar drugs of abuse including amphetamine (PA), methamphetamine (MA), 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA) and ketamine (Ke) as the model analytes. The experimental results revealed that the titania-OH-TSO coated stir bar exhibited highly pH-resistant ability, good preparation reproducibility, superior selectivity and high extraction efficiency for the target compounds. Based on this fact, a new method of titania-OH-TSO coated stir bar sorptive extraction (SBSE) combined with high performance liquid chromatography (HPLC)-ultraviolet visible (UV) detection was developed for the analysis of five drugs of abuse in urine samples. The factors affecting the extraction efficiency of SBSE such as sample pH, desorption solvent, sample volume, extraction time, desorption time, stirring rate and ionic strength were investigated and the optimal extraction conditions were established. Under the optimized conditions, the limits of detection (LODs) for titania-OH-TSO coated SBSE-HPLC-UV determination of five polar drugs of abuse were in the range of 2.3-9.1 μg/L with relative standard deviations (RSDs) ranging from 7.3 to 8.9% (c=300 μg/L, n=6), and all of the target compounds exhibited good linearity over a concentration range of 30-3000 μg/L. The developed method was applied to the determination of amphetamines and Ke in urine samples of drug abusers with satisfactory results.  相似文献   

14.
Abdel-Hay MH  Galal SM  Bedair MM  Gazy AA  Wahbi AA 《Talanta》1992,39(10):1369-1375
A highly sensitive spectrofluorimetric method for the determination of some drugs of the monosubstituted guanidine derivatives in laboratory made tablets, in spiked human serum and in urine samples is presented. The method is based on the reaction of guanethidine sulphate (I), guanoxan sulphate (II) and amiloride hydrochloride (III) with 9,10-phenanthraquinone (IV) to give highly fluorescent derivatives. The linearity ranges were found to be 0.06-0.96 mug/ml for (I) and (II) and 0.04-0.28 mug/ml for (III), with relative standard deviation less than 2%. Mean percentage recoveries for tablets were found to be 99.9 +/- 1.3, 100.5 +/- 1.1 and 100.0 +/- 1.6 for I, II and III, respectively. For I and III the results are highly correlated with the B.P. methods. Using the synchronous fluorimetry, differentiation between I and II was possible. Chloroform, dichloromethane and ethyl acetate have been used to extract I, II and III, respectively from serum and urine at basic pH, followed by applying the proposed fluorimetric method. Percentage recoveries were found to be 95.7-102.2%. The limit of detection is 0.04 mug/ml for I and II and 0.02 mug/ml for III.  相似文献   

15.
A method is developed for the gas chromatographic determination of chloroquine after extraction from biological material, using medazepam as the internal standard and a column filled with 3% OV-17 on Gas-Chrom Q. The detection limits are: 0.15 mug/ml of urine, 0.25 mug/ml of whole blood, and 1.50 mug/g of tissue. The technique can be applied in toxicological analysis and in monitoring drug levels.  相似文献   

16.
A sensitive and specific method for the analysis of 2-aminoethyl hydrogen sulfate in biological fluids by high-pressure liquid chromatography is described. Aliquots from deproteinized plasma or from acidified urine were subjected to ion-exchange clean-up by eluting with water through two columns packed with Dowex 1-X4 (Cl- form) and Dowex 50W-X8 (H+ form) resins. Recoveries in the eluates were consistent and quantitative (95-100%). Effluents from such treatment were chromatographed on a Durrum cation-exchange column with 0.05 M citrate buffer containing 0.15 N Na+ (pH 2.6). Detection was accomplished with an automated fluorescamine detection system. Using 2 ml of plasma or urine, 2-aminoethyl hydrogen sulfate could be assayed at concentrations of 0.3 mug/ml. Linear responses were observed up to at least 133 mug/ml. The method is both accurate and reproducible with a relative standard deviation of about +/- 4.0%.  相似文献   

17.
A new method of determination of genetically predetermined type of biotransformation by acetylation rate using reversed-phase liquid chromatography (RP-HPLC) was described. The method is based on determination of isonicotinic hydrazide (INH) which is excreted with the patient's urine during 24 h period after oral administration of 0.4 g of the drug. INH is used as pharmacogenetic marker. Precolumn derivatization of 4-chloro-5,7-dinitrobenzofurazan is used at RP-HPLC determination of INH and a new drug phosphabenzide (diphenylphosphinylacetic hydrazide, DPPAH) with specrtophotometric detection in urine. The limit of INH detection was 0.27 mug ml(-1) and the one of DPPAH was 0.82 mug ml(-1). As a result of pharmacokinetic investigation it was discovered that bimodal distribution by acetylation rate for DPPAH is less apparent than in the case of INH. It is shown, that immunomodulator xymedone (N-(beta-oxyethyl)-4,6-dimethyldihydropirimidon-2) is the acetylation inductor of xenobiotics.  相似文献   

18.
A specific and rapid liquid chromatographic/tandem mass spectrometric (LC/MS/MS) method was developed and validated for NNAL, a metabolite of the tobacco-specific nitrosamine metabolite NNK. The metabolite was detected in smokers' urine with a limit of quantitation (LOQ) of 20 pg ml(-1) and a linear range up to 1000 pg ml(-1). The method features a single solid-phase extraction step and MS/MS monitoring following electrospray ionization. Fragmentation pathways for the protonated molecular ion are proposed. The sample preparation is simpler than that for gas chromatographic methods reported in the literature and maintains sensitivity adequate for determining NNAL in smokers' urine. By using enzyme hydrolysis to determine total NNAL in urine, the amount of NNAL-glucuronide was calculated. A standard pooled smokers' urine sample used for development gave values of 176 +/- 8 pg ml(-1) free NNAL and 675 +/- 26 pg ml(-1) total NNAL following enzyme hydrolysis. The method was applied to a group of seven smokers; the free NNAL level for the group was 101-256 pg ml(-1) with NNAL-glucuronides at 247-566 pg ml(-1). The ratio of conjugated to free NNAL was in the range 0.98-2.95. The variability in total daily amount of NNAL excreted (ng per 24 h) had RSDs of 6-21% for free NNAL, 7-22% for conjugated NNAL and 6-20% for total NNAL excreted. When normalized to the number of cigarettes smoked, the amounts of NNAL excreted per cigarette smoked were in the range of amounts of NNK yields reported for cigarettes in the literature.  相似文献   

19.
A method using the lipophilic gel Lipidex 5000 for sorption of pentachlorophenol (PCP) from water and urine is described. The procedure for water gives a simultaneous clean-up from lipophilic contaminants and also offers the possibility for determination of less polar compounds, such as 1,1-bis(4-chlorophenyl)-2,2,2-trichloroethane (p,p'-DDT) and 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD), collected in a separate fraction. The extracted PCP is derivatized to pentachlorophenyl acetate, which is determined by electron-capture gas chromatography. The average recovery of 0.01-0.15 ng PCP per ml water was 96% and of labelled p,p'-DDT (ca. 5 ng/ml) and TCDD (ca. 0.001 ng/ml) 95 and 92%, respectively. A similar method for enrichment of PCP was applied to acidified urine and to urine hydrolysed with hydrochloric acid or with digestive juice from Helix pomatia. Recoveries of 0.1-2.5 ng PCP per ml non-hydrolysed urine were on an average 92% and of 2.5-10 ng PCP per ml hydrolysed urine 96%. The analyses indicate that PCP in urine from non-occupationally exposed persons is originally conjugated and to some extent liberated when stored. The contamination of organic solvents and laboratory environments with PCP is discussed.  相似文献   

20.
The development of a liquid chromatography high-resolution mass spectrometry quadrupole-time-of-flight (LC-HRMS-QTOF) method for the analysis of new stimulant designer drugs (e.g. phenethylamine, amphetamine, cathinone and piperazine derivatives) and common drugs of abuse (e.g. ketamine and ritalinic acid) in urine is reported. Sample preparation was carried out by a fast and convenient salting-out liquid-liquid extraction (SALLE) procedure. The data was generated by a preferred target list combined with untargeted data-dependent acquisition recording additional sample information (i.e. not listed metabolites of target compounds or not database-stored drugs). The identification is realised by a fully automated data extraction algorithm, taking into account accurate mass spectra, fragment masses and retention times. Method validation comprised selectivity, linearity, accuracy, stability, determination of the limit of detection (LOD) and limit of quantification (LOQ) and evaluation of matrix effects and recoveries for a total set of 39 compounds. Acceptable quantitative results were obtained for 35 of the 39 analytes. Exemplarily, application of the additional untargeted data-dependent acquisition mode enabled the identification of metabolites of the preferred target list compounds ketamine and methylenedioxypyrovalerone (MDPV) without use of reference standards. Therefore, improvement of the database is feasible with every positive library hit. The approach presented here provides a very useful tool for the combined targeted and untargeted analysis of drugs of abuse in biological matrices such as urine.  相似文献   