首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A gas chromatography-tandem mass spectrometry method for detection of diazepam, nordazepam and oxazepam is presented. The method associates electron capture ionization and multiple reaction monitoring (MRM). No derivatization is performed; oxazepam undergoes thermal degradation during chromatographic injection and is thus quantified via its decomposition product. The negative molecular ions are so stable that they do not dissociate when collision is performed under "classical" conditions (i.e. with argon as collision gas). With xenon as collision gas, the energy transfer is sufficient to provide two product ions for diazepam and nordazepam and one product ion for the decomposition product of oxazepam. The sample preparation part involves liquid/liquid extraction with TOXI-TUBES A extraction tubes; it provides recovery yields between 68 and 95%, depending of the benzodiazepine considered, with coefficients of variation below 6% for 10 samples. The applicability of the method was demonstrated on urine extracts. From 1 mL of urine, the method provides quantitation limits of 0.15 ng/mL for diazepam, 1.0 ng/mL for nordazepam and 1.5 ng/mL for oxazepam. Mechanisms of dissociation of M*(-) ions of benzodiazepines are suggested.  相似文献   

2.
A detailed procedure for the analysis of four beta-blockers, acebutolol, labetalol, metoprolol and propranolol, in human plasma by high-performance liquid chromatography (LC)-tandem mass spectrometry (MS-MS) using an MSpak GF column, which enables direct injection of crude plasma samples, is presented. Protein and/or macromolecule matrix compounds were eluted first from the column, while the drugs were retained on the polymer stationary phase of the MSpak GF column. The analytes retained on the column were then eluted into an acetonitrile-rich mobile phase using a gradient separation technique. All drugs showed base peak ions due to [M + H]+ ions by LC-MS with positive ion electrospray ionization, and the product ions were produced from each [M + H]+ ion by LC-MS-MS. Quantification was performed by selected reaction monitoring. The recoveries of the four beta-blockers spiked into plasma were 73.5-89.9%. The regression equations for all compounds showed excellent linearity in the range 10-1000 ng/mL of plasma, with the exception of propranolol (10-800 ng/mL). The limits of detection and quantification for each drug were 1-3 and 10 ng/mL, respectively, of plasma. The intra- and inter-day coefficients of variation for all drugs in plasma were not greater than 10.9%.  相似文献   

3.
A novel and simple online solid‐phase extraction liquid chromatography‐tandem mass spectrometry method was developed and validated for the simultaneous determination of diazepam and its five metabolites including nordazepam, oxazepam, temazepam, oxazepam glucuronide, and temazepam glucuronide in human oral fluid. Human oral fluid was obtained using the Salivette® collection device, and 100 μL of oral fluid samples were loaded onto HySphere Resin GP cartridge for extraction. Analytes were separated on a Waters Xterra C18 column and quantified by liquid chromatography with tandem mass spectrometry using the multiple reaction monitoring mode. The whole procedure was automatic, and the total run time was 21 min. The limit of detection was in the range of 0.05–0.1 ng/mL for all analytes. The linearity ranged from 0.25 to 250 ng/mL for oxazepam, and 0.1 to 100 ng/mL for the other five analytes. Intraday and interday precision for all analytes was 0.6–12.8 and 1.0–9.2%, respectively. Accuracy ranged from 95.6 to 114.7%. Method recoveries were in the range of 65.1–80.8%. This method was fully automated, simple, and sensitive. Authentic oral fluid samples collected from two volunteers after consuming a single oral dose of 10 mg diazepam were analyzed to demonstrate the applicability of this method.  相似文献   

4.
Abstract

A reversed phase high-performance liquid chromatographic method (HPLC) for the simultaneous determination of diazepam and its three active metabolites, nordazepam, oxazepam and temazepam, in plasma was proposed. The compounds were isolated by solid-phase extraction. The chromatographic mobile phase was metanol-water (55:45, v/v) at a flow rate of 1 mL/min. UV detection was performed concurrently at 240 and 254 nm.  相似文献   

5.
For studies on the excretion of drugs into milk a sensitive high-performance liquid chromatographic assay was developed to quantitate diazepam and nordazepam in the milk and plasma of humans and rabbits in the presence of their major metabolites, oxazepam and temazepam. Flurazepam was used as an internal standard. The assay involves extractions with diethyl ether and an additional acid clean-up step. Chromatographic separation was achieved by a LiChrospher 60 RP-select B (5 microns) column and KH2PO4- acetonitrile (69:31, v/v) adjusted to pH 2.80 as a mobile phase. The same extraction and chromatographic conditions were suited to both types of samples, milk and plasma. The limits of determination using ultraviolet detection at 241 nm was for diazepam 20 ng/ml and for nordazepam 15 ng/ml. The absolute recoveries of diazepam, nordazepam and flurazepam in human milk were 84, 86 and 92% and in human plasma 97, 89 and 94%, respectively. The within- and between-day accuracy and precision for diazepam and nordazepam in milk and plasma at all concentrations tested (20-1500 ng/ml) were better than 8%. The high fat content which occurs in rabbit milk presented no limitation for the extraction of lipophilic diazepam: the method was successfully used to monitor milk and plasma concentrations of diazepam and nordazepam in lactating New Zealand White rabbits during 26-h infusions of diazepam (1.4 mg/h).  相似文献   

6.
A study is presented for the separation and determination of fifteen 1,4-benzodiazepine drugs and metabolites by capillary electrophoresis (CE) compared with high-performance liquid chromatography (HPLC). A comparison is made between the CE determination of the compounds by conventional UV detection and LC determination with electrospray ionisation (ESI) ion-trap mass spectrometry. CE is shown to provide superior separation to HPLC but the MS-MS capability of the ion-trap allows for the specific detection and determination of four of the compounds, diazepam, N'-desmethyldiazepam, oxazepam and temazepam in the hair of a patient under clinical treatment with diazepam and temazepam. Selected mixtures of drugs and metabolites are determined by CE and LC and the determination of diazepam and its metabolites by CE-UV-ESI-MS-MS is also presented.  相似文献   

7.
A rapid and specific HPLC method was developed and validated for simultaneous determination of diazepam and its main active metabolites, desmethyldiazepam, oxazepam and temazepam in human plasma. Plasma samples were extracted using toluene. HPLC system included a Chromolith Performance RP-18e 100 mm x 4.6mm column, using 10mM phosphate buffer (pH 2.5)-methanol-acetonitrile (63:10:27, v/v) as mobile phase running at 2 mL min(-1). UV detector (lambda=230 nm) was used. The calibration curves were linear in the concentration range of 2-800 ng mL(-1) for diazepam and 2-200 ng mL(-1) for the three metabolites (r(2)>0.99). The lower limit of quantification was 2 ng mL(-1) for all analytes. Within and between-day precisions in the measurement of QC samples were in the range of 1.8-18.0% for all analytes. The developed procedure was used to assess the pharmacokinetics of diazepam and its main metabolites following single dose administration of 10mg diazepam orally to healthy subjects.  相似文献   

8.
The feasibility of directly assaying drugs in physiological fluids using on-line preconcentration and microbore high-performance liquid chromatography has been demonstrated. The untreated sample is injected onto a hydrophobic pre-column, using micellar sodium dodecyl sulfate (SDS) in the case of serum or phosphate buffer in the case of urine, as the load mobile phase. This traps the components of interest which are then backflushed onto a microbore analytical column using a stronger mobile phase. This procedure was then applied to diazepam in serum and phenobarbital in urine. Recovery was linear and quantitative over the range 30-3000 ng/ml for diazepam in serum and 2-200 micrograms/ml for phenobarbital in urine. The diazepam method was specific against caffeine and the three major metabolites of diazepam: oxazepam, temazepam, and nordiazepam. The effects of varying pre-column dimensions, pre-column loading time, and SDS concentration volume were evaluated.  相似文献   

9.
Quantitative information on drug metabolites with pharmacological or toxicological activities is of great interest during the drug discovery and development process. Because the analyte response with mass spectrometry can change significantly due to small variations in chemical structure, pure standards are required to construct standard curves for quantitation. However, for most programs at the discovery stage, pure metabolite standards are not available. In this work, an evaluation was conducted using a chemiluminescent nitrogen detector (CLND) as a calibrator to obtain the response factor ratio on a mass spectrometer generated from a metabolite and its parent compound in biological fluids. Using the response factor ratio obtained from the CLND, the metabolite could be quantified with the liquid chromatography/tandem mass spectrometry (LC/MS/MS) response obtained from the parent drug's standard curve. For this evaluation, oxazepam and temazepam were chosen as a 'drug/metabolite' pair. Temazepam was treated as the methylated metabolite of oxazepam. A spiked dog urine sample with a known concentration of oxazepam and unknown concentration of temazepam was injected onto the HPLC system and detected by both the CLND and MS/MS. Taking advantage of the equimolar response feature of the CLND, a response factor ratio between temazepam and oxazepam on the mass spectrometer was obtained by comparing the peak areas generated on the CLND and the mass spectrometer. From this ratio, temazepam was quantified using the oxazepam standard curve. The difference between the concentration of temazepam obtained from the reconstructed standard curve and the concentration obtained directly from a real temazepam standard curve was within 13% except the least concentrated standard (31%). This methodology has been successfully applied to measure quantities of the metabolite of a proprietary compound in a dog pharmacokinetic (PK) study.  相似文献   

10.
A new screening procedure for 18 narcotics in urine for anti-doping purposes has been developed using liquid chromatography/triple quadrupole mass spectrometry (LC/MS). Electrospray ionization (ESI) was used as interface. Infusion experiments were performed for all substances to investigate their mass spectrometric behaviour in terms of selecting product specific ions. These product ions were then used to develop a tandem mass spectrometric method using selected reaction monitoring (SRM). For the LC/MS analysis, chromatography was performed on an octadecylsilane column. The total run time of the chromatographic method was 5.5 min. For the sample preparation prior to LC/MS analysis, the urine samples were liquid-liquid extracted at pH 9.5 after overnight enzymatic hydrolysis. Two extraction solvents were evaluated: dichloromethane/methanol 9/1 (v/v), which is currently used for the extraction of narcotics, and diethyl ether, used for the extraction of steroids. With diethyl ether the detection limits for all compounds ranged between 0.5 and 20 ng/mL and with the mixture containing dichloromethane the detection limits ranged between 0.5 and 10 ng/mL. Taking into account the minimum required performance limits of the World Anti-Doping Agency of 200 ng/mL for narcotics, diethyl ether can also be considered as extraction solvent for narcotics. Finally, the described method was applied to the analysis of urine samples previously found to contain narcotics by our routine gas chromatography/mass spectrometry (GC/MS) method.  相似文献   

11.
A sensitive and specific liquid chromatography/mass spectrometry (LC/MS) method has been developed and validated for the quantification of the modified gamma-cyclodextrin Org 25969 and Rocuronium bromide (Roc or Org 9426) in the plasma and urine of guinea pigs. The assay was linear and reproducible over the range 25-10000 ng/mL for both compounds. The lowest limit of quantification (LLOQ) for both compounds in urine was 25 ng/mL. In plasma, the LLOQ was 25 ng/mL for Org 9426 and 50 ng/mL for Org 25969. The inter- and intra-day variation was lower than 20%. The physicochemical properties of both compounds imposed different modes of extraction from plasma. The modified gamma-cyclodextrin was extracted by trifluoroacetic acid (TFA) precipitation while Rocuronium was extracted by acetonitrile precipitation. Both compounds were quantified in urine by direct injection onto the column. The LC/MS analyses of Org 25969 and Org 9426 were performed using two different assay conditions. It was not possible to quantify the complex of cyclodextrin and Roc as it dissociated on the LC column. The use of LC/MS conferred great advantage to the quantification of both Org 25969 and Org 9426, as they were not chromogenic enough to afford the sensitivity and specificity required for the assay.  相似文献   

12.
A restricted access material (RAM), alkyl-diol-silica (ADS), was used to prepare a highly bio-compatible solid-phase microextraction (SPME) capillary for the automated and direct in-tube extraction of several benzodiazepines from human serum. The bifunctionality of the ADS extraction phase prevented fouling of the capillary by protein adsorption while simultaneously trapping the analytes in the hydrophobic porous interior. This the first report of a restricted access material utilized as an extraction phase for in-tube SPME. The approach simplified the required apparatus in comparison to existing RAM column switching procedures, and more importantly eliminated the excessive use of extraction solvents. The biocompatibility of the ADS material also overcame the existing problems with in-tube SPME that requires an ultrafiltration or other deproteinization step prior to handling biological samples, therefore further minimizing the sample preparation requirements. The calculated oxazepam, temazepam, nordazepam and diazepam detection limits were 26, 29, 22 and 24 ng/ml in serum, respectively. The method was linear over the range of 50-50 000 ng/ml with an average linear coefficient (R2) value of 0.9998. The injection repeatability and intra-assay precision of the method were evaluated with five injections of a 10-microg/ml serum sample (spiked with all compounds), resulting in an average RSD<7%. The ADS extraction column was robust, providing many direct injections of biological fluids for the extraction and subsequent determination of benzodiazepines.  相似文献   

13.
Diazepam (DZP) is one of the most commonly prescribed drugs for treating status epilepticus (SE). A simple, sensitive and selective LC/MS/MS method with a wide linear calibration range was developed to quantify DZP and its major metabolites, N-desmethyldiazepam (DMDZP), temazepam (TZP), and oxazepam (OZP), in rat cerebrospinal fluid (CSF). The method was used to simultaneously determine the concentrations of all analytes in a small sample volume (as little as 25 microL) of rat CSF. The lower limits of quantification (LLOQ) of the method are 0.04 ng/mL for DZP and 0.1 ng/mL for its metabolites. The calibration range is 0.04-200 ng/mL for DZP and 0.1-200 ng/ml for the metabolites. All intra- and inter-assay coefficients of variation (%CV) and mean percent errors of the method are less than 12%. This method successfully addresses the need to determine low therapeutic drug concentrations in small physiological samples, namely rat CSF. Moreover, it can be used to investigate the distribution of the drug and its metabolites among blood plasma, brain tissue, and CSF in pharmacokinetic and pharmacodynamic studies in a variety of laboratory animals. With respect to animal experiments involving assays in CSF, this method addresses two of the three criteria of Russell and Bruch (Principles of Humane Experimental Techniques, 1959, Methuen and Co., London) for minimizing animal use, namely refinement and reduction.  相似文献   

14.
Different liquid chromatographic/tandem mass spectrometric (LC/MS/MS) scanning techniques were considered for the characterization of tamoxifene metabolites in human urine for anti‐doping purpose. Five different LC/MS/MS scanning methods based on precursor ion scan (precursor ion scan of m/z 166, 152 and 129) and neutral loss scan (neutral loss of 72 Da and 58 Da) in positive ion mode were assessed to recognize common ions or common losses of tamoxifene metabolites. The applicability of these methods was checked first by infusion and then by the injection of solution of a mixture of reference standards of four tamoxifene metabolites available in our laboratory. The data obtained by the analyses of the mixture of the reference standards showed that the five methods used exhibited satisfactory results for all tamoxifene metabolites considered at a concentration level of 100 ng/mL, whereas the analysis of blank urine samples spiked with the same tamoxifene metabolites at the same concentration showed that the neutral loss scan of 58 Da lacked sufficient specificity and sensitivity. The limit of detection in urine of the compounds studied was in the concentration range 10–100 ng/mL, depending on the compound structure and on the selected product ion. The suitability of these approaches was checked by the analysis of urine samples collected after the administration of a single dose of 20 mg of tamoxifene. Six metabolites were detected: 4‐hydroxytamoxifene, 3,4‐dihydroxytamoxifene, 3‐hydroxy‐4‐methoxytamoxifene, N‐demethyl‐4‐hydroxytamoxifene, tamoxifene‐N‐oxide and N‐demethyl‐3‐hydroxy‐4‐methoxytamoxifene, which is in conformity to our previous work using a time‐of‐flight (TOF) mass spectrometer in full scan acquisition mode. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

15.
Paraquat (PQ) and diquat (DQ) in human whole blood and urine were analyzed by high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) with positive ion electrospray ionization (ESI). The compounds were extracted with Sep-Pak C18 cartridges from whole blood and urine samples containing ethyl paraquat as an internal standard. The separation of PQ and DQ was carried out using ion-pair chromatography with heptafluorobutyric acid in 20 mM ammonium acetate and acetonitrile gradient elution for successful coupling with MS. Both compounds formed base peaks due to [M-H]+ ions by HPLC/ESI-MS and the product ions produced from each [M-H]+ ion by HPLC/MS/MS. Selective reaction monitoring (SRM) showed much higher sensitivity for both body fluids. Therefore, a detailed procedure for the detection of compounds by SRM with HPLC/MS/MS was established and carefully validated. The recoveries of PQ and DQ were 80.8-95.4% for whole blood and 84.2-96.7% for urine. The calibration curves for PQ and DQ showed excellent linearity in the range of 25-400 ng ml(-1) of whole blood and urine. The detection limits were 10 ng ml(-1) for PQ and 5 ng ml(-1) for DQ in both body fluids. The intra- and inter-day precision for both compounds in whole blood and urine samples were not greater than 13.0%. The data obtained from the determination of PQ and DQ in rat blood after oral administration of the compounds are also presented.  相似文献   

16.
A new monolithic coating based on vinylpyrrolidone‐ethylene glycol dimethacrylate polymer was introduced for stir bar sorptive extraction. The polymerization step was performed using different contents of monomer, cross‐linker and porogenic solvent, and the best formulation was selected. The quality of the prepared vinylpyrrolidone‐ethylene glycol dimethacrylate stir bars was satisfactory, demonstrating good repeatability within batch (relative standard deviation < 3.5%) and acceptable reproducibility between batches (relative standard deviation < 6.0%). The prepared stir bar was utilized in combination with ultrasound‐assisted liquid desorption, followed by high‐performance liquid chromatography with ultraviolet detection for the simultaneous determination of diazepam and nordazepam in human plasma samples. To optimize the extraction step, a three‐level, four‐factor, three‐block Box–Behnken design was applied. Under the optimum conditions, the analytical performance of the proposed method displayed excellent linear dynamic ranges for diazepam (36–1200 ng/mL) and nordazepam (25–1200 ng/mL), with correlation coefficients of 0.9986 and 0.9968 and detection limits of 12 and 10 ng/mL, respectively. The intra‐ and interday recovery ranged from 93 to 106%, and the relative standard deviations were less than 6%. Finally, the proposed method was successfully applied to the analysis of diazepam and nordazepam at their therapeutic levels in human plasma. The novelty of this study is the improved polarity of the stir bar coating and its application for the simultaneous extraction of diazepam and its active metabolite, nordazepam in human plasma sample. The method was more rapid than previously reported stir bar sorptive extraction techniques based on monolithic coatings, and exhibited lower detection limits in comparison with similar methods for the determination of diazepam and nordazepam in biological fluids.  相似文献   

17.
A reliable and easy to use liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed for the simultaneous quantification of urinary concentrations of cyclophosphamide (CP) and its main metabolites excreted in urine, i.e. N-dechloroethylcyclophosphamide (DCL-CP), 4-ketocyclophosphamide (4KetoCP), and carboxyphosphamide (CarboxyCP). Sample preparation consisted of dilution of urine with an aqueous solution of the internal standard D(4)-CP and methanol, and centrifugation. LC/MS/MS detection was performed using a triple-quadrupole mass spectrometer working in selected reaction monitoring mode. All analytes were quantified in a single run within 11.5 min. The limits of detection were 5 ng/mL for CP and 4KetoCP, 1 ng/mL for DCL-CP, and 30 ng/mL for CarboxyCP. Quantification ranges were adjusted to the expected concentrations in 24-h urine collections of patients treated with a polychemotherapy regimen (3-175 microg/mL for CP, 0.5-27 microg/mL for 4KetoCP and 0.17-9 microg/mL for CarboxyCP and DCL-CP, respectively). The method was validated according to international guidelines of the ICH and the FDA.  相似文献   

18.
孙雷  张骊  徐倩  王树槐  汪霞 《色谱》2010,28(1):38-42
建立了猪肉和猪肾中安眠酮、氯丙嗪、异丙嗪、地西泮、硝西泮、奥沙西泮、替马西泮、咪达唑仑、三唑仑和唑吡旦10种镇静剂类药物残留检测的超高效液相色谱-串联质谱分析方法。样品经酶解后,调节pH值呈碱性,分别用乙酸乙酯和叔丁基甲醚进行萃取,高速冷冻离心去除脂肪等杂质。提取液经Waters Acquity UPLC BEH C18色谱柱分离,以0.1%甲酸乙腈溶液和0.1%甲酸水溶液为流动相进行梯度洗脱。电喷雾正离子(ESI+)模式电离,多反应监测(MRM)模式检测,基质匹配标准溶液法进行定量。结果表明: 10种镇静剂在2~100 μg/L范围内呈良好的线性关系,相关系数(r)均大于0.998; 10种镇静剂的检出限(S/N>3)为0.5 μg/kg,定量限(S/N>10)为1 μg/kg。3个添加水平的回收率为64.5%~111.4%,批内、批间相对标准偏差(RSD)均小于15%。该方法具有简便快捷、灵敏度高、定性准确等特点。  相似文献   

19.
A simple and rapid method using reversed-phase liquid chromatography/tandem mass spectrometry (LC/MS/MS) for the simultaneous determination of the urinary metabolites of benzene, toluene, xylene and styrene in human urine specimens and standard solutions is described. A hybrid quadrupole/time-of-flight (QqTOF) mass spectrometer was compared for the determination of metabolite of aromatic solvents in urine samples. The metabolites selected were: trans,trans-muconic acid, hippuric acid, o-, m- and p-methylhippuric acid and phenylglyoxylic acid. The compounds were well separated from each other on narrow-bore 1-mm i.d. reversed-phase LC C-18 columns. Average recoveries for loading 100 microL of urine samples varied from 88-110% and the quantification limits were less than 30 ng/mL for each analyte (3 ng/mL for trans,trans-muconic acid). The qualitative information obtained (mass accuracy, resolution and full-scan spectra) with the QqTOF mass spectrometer allows a secure identification of analytes in biological matrices.  相似文献   

20.
A generic high-throughput liquid chromatography (HTLC) tandem mass spectrometry (MS/MS) assay for the determination of compound I in human urine and dialysate (hemodialysis) was developed and validated. By using the HTLC on-line extraction technique, sample pretreatment was not necessary. The sample was directly injected onto a narrow bore large particle size extraction column (50 x 1.0 mm, 60 microm) where the sample matrix was rapidly washed away using a high flow rate (5 mL/min) aqueous mobile phase while analytes were retained. The analytes were subsequently eluted from the extraction column onto an analytical column using an organic-enriched mobile phase prior to mass spectrometric detection. The analytes were then eluted from the analytical column to the mass spectrometer for the determination. The linear dynamic range was 2.0-6000 ng/mL for the urine assay and 0.1-300 ng/mL for the dialysate assay. Intraday accuracy and precision were evaluated by analyzing five replicates of calibration standards at all concentrations used to construct the standard curve. For the urine assay, the precision (RSD%, n=5) ranged from 1.9 to 8.0% and the accuracy ranged from 87.8 to 105.2% of nominal value. For the dialysate assay, the precision (RSD%, n=5) ranged from 1.1 to 10.0% and the accuracy from 94.5 to 105.2% of nominal value. In-source fragmentation of the acyl glucuronide metabolite (compound III) did not interfere with the determination of parent compound I. The developed HTLC/MS/MS methodology was specific for compound I in the presence of compound III. Column life-time is increased and sample analysis time is decreased over traditional reversed-phase methods when direct injection assays for urine and dialysate are coupled with the technology of HTLC.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号