首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The scaling up of the separation of two proteins with an aqueous two-phase system (ATPS) from 176 mg with a 500 ml laboratory scale centrifugal partition chromatography (CPC) column to 2.2g with a 6.25 litre pilot-scale column is presented. A model sample system of a mixture of lysozyme and myoglobin was chosen for this study using an ATPS system comprising 12.5% (w/w) PEG-1000:12.5% (w/w) K2HPO4. It was found that the maximum sample concentration possible without precipitation was 2.2mg/ml for each constituent. The optimisation of rotor speed, mobile phase flow rate and sample loading was performed on a laboratory-scale device. It was found that a centrifuge speed of 2000 rpm (224 'g'), 10 ml/min mobile phase flow rate with a 43 ml (10% of active column volume) sample volume gave optimum operating conditions. This was linearly scaled up to pilot scale by increasing mobile phase flow rate, fraction size and sample loading in the ratio of the system capacities (i.e. 12.5:1). Flow rate was therefore increased from 10 ml/min to 125 ml/min, fraction size from 10 ml to 125 ml and sample loading from 43 ml to 500 ml. Rotor speed however was reduced from 2000 rpm on the laboratory device to 1293 rpm on the pilot-scale device to maintain the same 224 'g' field in each chamber, as the pilot-scale CPC unit has a larger rotor radius than the laboratory one. Resolution increased from Rs=1.28 on the 500 ml rotor to Rs=1.88 on the 6.25 litre rotor, giving potential throughputs in batch mode of over 40 g/day.  相似文献   

2.
A high-speed counter-current chromatography (HSCCC) technique in a preparative scale has been applied to separate and purify cordycepin from the extract of Cordyceps militaris(L.) Link by a one-step separation. A high efficiency of HSCCC separation was achieved on a two-phase solvent system of n-hexane-n-butanol-methanol-water (23:80:30:155, v/v/v/v) by eluting the lower mobile phase at a flow rate of 2 ml/min under a revolution speed of 850 rpm. HSCCC separation of 216.2 mg crude sample (contained cordycepin at 44.7% purity after 732 cation-exchange resin clean-up) yielded 64.8 mg cordycepin with purity of 98.9% and 91.7% recovery. Identification of the target compound was performed by UV, IR, MS, (1)H NMR and (13)C NMR.  相似文献   

3.
Luo Q  Gu Y  Wu SL  Rejtar T  Karger BL 《Electrophoresis》2008,29(8):1604-1611
This study expands the capabilities for ultratrace proteomic analysis of our previous work by incorporating on-line sample desalting using a triphasic (RP/strong cation exchange (SCX)/micro-SPE) trapping column connected to a 3.2 m x 10 microm id poly(styrene-divinylbenzene) (PS-DVB) porous layer open tubular (PLOT) column. To minimize extra sample handling steps, C18 RP packing was incorporated in the capillary tubing upstream of the SCX column for the on-line desalting. For the micro-SPE column, a 50 microm id PS-DVB monolithic column was positioned downstream of the SCX column. High-performance separation was achieved on the PLOT column at a mobile phase flow rate of 20 nL/min. The sensitivity and high resolution capability of the new multidimensional platform was evaluated using an in-gel tryptic digested sample of a cervical cancer (SiHa) cell line. For the injected amount of 1200 cells ( approximately 500 ng), over 2700 peptides covering greater than 850 unique proteins were identified from the triphasic SCX/PLOT/MS analysis of a single SDS gel section (>40 kDa). The 2-D LC/MS platform demonstrated good separation performance, such that more than 85% of the identified peptides were detected from only one salt fraction. In a triplicate analysis of the above >40 kDa gel section, 4497 peptides and 1209 unique proteins were identified when applying stringent filtering criteria, with a false-positive rate of 2.4%. When all three SDS-PAGE gel sections of the lysed SiHa cells were analyzed, 5047 peptides and 1857 unique proteins (false-positive rate 1.8%), including cancer-related proteins such as MAP kinases, were identified.  相似文献   

4.
分析型色谱饼对人血清白蛋白的快速纯化   总被引:1,自引:0,他引:1  
姚文兵  吴丹  耿信笃 《色谱》2004,22(2):121-123
采用分析型色谱饼对标准蛋白混合物进行了分离,结果表明装填有小颗粒填料的色谱饼在高流速条件下仍然具有良好的分离能力。在较大流速(5 mL/min)条件下,在10 min内对人血清白蛋白样品进行了快速纯化,其纯化后的人血清白蛋白的纯度大于85%,回收率为65%,说明分析型色谱饼可以用于快速分离纯化生物大分子。  相似文献   

5.
Very fast GC analyses are commonly carried out by using 10 m x 0.1 mm id capillaries. In order to achieve rapid elution times (1-3 min), the latter are operated under suboptimum conditions. The present research is focused on the evaluation of use of a 0.1 mm id polar column segment (2 m), operated under near-to-optimum conditions, in very fast GC analysis. The results attained are compared with those derived from using a 10 m microbore column in very fast GC experiments. Prior to method development, the effects of gas velocity, temperature program rate, and sample amounts on analytical performance were evaluated. Following these preliminary applications, a complex lipidic sample, cod liver oil, was subjected to rapid separation (approximately 2.1 min) on the 10 m capillary through the application of a 50 degrees C/min temperature rate and a 130 cm/s gas velocity. The same matrix was analyzed on the 2 m capillary using the same temperature program rate and range, but with a close-to-ideal linear velocity. The results observed were of interest, as the separation was achieved in less time (1.45 min) with improved peak resolution. Finally, both methods were validated in terms of retention time and peak area repeatability, LOQ, and linearity.  相似文献   

6.
Novel HPLC methods were developed for the analytical and semipreparative resolution of new antidepressant drug mirtazapine enantiomers. At analytical scale, the separation of the mirtazapine enantiomers was investigated using both cellulose and amylose tris(3,5-dimethylphenylcarbamate) (CDMPC and ADMPC) chiral stationary phases under normal-phases and polar organic modes. Good baseline enantioseparation was achieved using cellulose tris(3,5-dimethylphenylcarbamate) chiral stationary phases under both normal-phases and polar organic modes. Furthermore, the elution order of mirtazapine enantiomic pairs was found reversed by changing the stationary phase from the amylose-based ADMPC–CSPs to its cellulose-based counterpart, CDMPC–CSPs. The validation of the analytical methods including linearity, limit of detection (LOD), limit of quantification (LOQ), recovery and precision, together with the semipreparative resolution of mirtazapine racemate were carried out using cellulose tris(3,5-dimethylphenylcarbamate) chiral stationary phases and methanol as mobile phase without any basic additives under polar organic mode. At analytical scale, the elution times of both enantiomers were less than 6 min at normal temperature and 1.0 ml/min, with the separation factor () 1.99 and the resolution factor (Rs) 3.56. Then, the analytical methods were scaled up to semipreparative loading to obtain small quantities of both mirtazapine enantiomers. At semipreparative scale, about 16 mg/h enantiomers could be isolated and elution times of both enantiomers were less than 10 min at 2.0 ml/min. To increase the throughput, the technique of boxcar injections was used. One enantiomer ((−)-(R)-mirtazapine) was isolated with purity of >99.9% e.e. and >98.0% yield and another ((+)-(S)-mirtazapine) was isolated with purity of >97.0% e.e. and >99.0% yield. In addition, optical rotation and circular dichroism (CD) spectroscopy of both mirtazapine enantiomers isolated were also investigated.  相似文献   

7.
The feasibility of using a monolithic column as the analytical column in conjunction with high-flow direct-injection liquid chromatography/tandem mass spectrometry (LC/MS/MS) to increase productivity for quantitative bioanalysis has been investigated using plasma samples containing a drug and its epimer metabolite. Since the chosen drug and its epimer metabolite have the same selected reaction monitoring (SRM) transitions, chromatographic baseline separation of these two compounds was required. The results obtained from this monolithic column system were directly compared with the results obtained from a previously validated assay using a conventional C18 column as the analytical column. Both systems have the same sample preparation, mobile phases and MS conditions. The eluting flow rate for the monolithic column system was 3.2 mL/min (with 4:1 splitting) and for the C18 column system was 1.2 mL/min (with 3:1 splitting). The monolithic column system had a run time of 5 min and the conventional C18 column system had a run time of 10 min. The methods on the two systems were found to be equivalent in terms of accuracy, precision, sensitivity and chromatographic separation. Without sacrificing the chromatographic separation, sensitivity, accuracy and precision of the method, the reduced run time of the monolithic column method increased the sample throughput by a factor of two.  相似文献   

8.
Qiao Q  Du Q 《Journal of chromatography. A》2011,1218(36):6187-6190
The flash high speed counter-current chromatographic (FHSCCC) separation of gingerols and 6-shogaol was performed on a HSCCC instrument equipped with a 1200-ml column (5 mm tubing i.d.) at a flow rate of 25 ml/min. The performance met the FHSCCC feature that the flow rate of mobile phase (ml) is equal to or greater than the square of the diameter of the column tubing (mm). The separation employed the upper phase of stationary phase of the n-hexane-ethyl acetate-methanol-water (3:2:2:3, v/v) as the stationary phase. A stepwise elution was performed by eluting with the lower phase of n-hexane-ethyl acetate-methanol-water (3:2:2:3, v/v) for first 90 min and the lower phase of the n-hexane-ethyl acetate-methanol-water (3:2:6:5, v/v) for the second 90 min. In each separation 5 g of the ethyl acetate extract of rhizomes of ginger was loaded, yielding 1.96 g of 6-gingerol (98.3%), 0.33 g of 8-gingerol (97.8%), 0.64 g of 6-shogaol (98.8%) and 0.57 g of 10-gingerol (98.2%). The separation can be expected to scale up to industrial separation.  相似文献   

9.
With the ever-increasing workload from a variety of in vitro and in vivo screening procedures, new analytical methodologies to perform bioanalysis in an accurate and high-throughput manner are in great demand. In this work, monolithic columns were used instead of conventional particulate HPLC columns to perform chromatographic separations. Because the pressure drop on a monolithic column was considerably lower than that on a particulate column, a high flow rate (6 mL/min) was used for a 4.6 x 50 mm monolithic column with a total backpressure of about 61 bar measured using acetonitrile/water (50:50). The capability of using a regular column length at high flow rates, combined with the extremely small dependency of separation efficiency on linear flow velocity, allowed for the generation of sufficient chromatographic resolving power in a significantly reduced runtime. As demonstrated in this work, a plasma extract of a mixture of tempazepam, tamoxifen, fenfluramine, and alprozolam were baseline separated within a total analysis time of one minute. An average peak width at half maximum of approximately one second was noted using a generic broad gradient. It was also found that the separation efficiency and signal/noise (S/N) ratios for this separation remained almost constant at flow rates of 1, 3, and 6 mL/min, respectively. The ruggedness of the separation was evaluated by injecting 600 plasma extracts containing the replicates of a standard curve of the above mixture during an overnight run. The chromatographic retention time, separation quality, peak response and sensitivity were highly reproducible throughout the run. This high-speed liquid chromatography/tandem mass spectrometry (LC/MS/MS) system has been used routinely in the authors' laboratory to support drug discovery programs.  相似文献   

10.
In this work, a fast analytical method based on hydrophilic interaction liquid chromatographic-Ultraviolet detection (HILIC-UV) using a short narrow bore cyano-bonded silica column packed with fully porous sub-2?µm particles has been developed for simultaneous determination of eight pharmaceuticals in wastewater. The method involved pre-concentration and clean-up by solid phase extraction using Oasis HLB extraction cartridges. The analytes were separated using a mobile phase consisted of acetonitrile and 5?mM ammonium acetate buffer (95:5?v/v) with a flow rate of 0.6?mL/min. The chromatographic separation was optimized in order to achieve short analysis time and good resolution for all analytes in a single run. Each analyte was detected at its maximum wavelength for higher sensitivity. All analytes could be separated in 5.7?min with resolution ≥2.7. The optimized method was validated based on linearity, precision, detection and quantification limits, selectivity and accuracy. The detection limits of the studied pharmaceuticals ranged from 0.6 to 3?µg/L, while limits of quantification were in the range from 2 to 10?µg/L with UV detection. The developed method is fast, reliable, cost-effective and could be used for the analysis of the studied analytes in other matrices such as food, pharmaceutical preparations and biological fluids.  相似文献   

11.
Counter-current chromatographic separation of proteins was performed using a rotary-seal-free nonsynchronous coil planet centrifuge (CPC) fabricated in our laboratory. This apparatus has a unique feature that allows a freely adjustable rotational rate of the coiled separation column at a given revolution speed. The separation was performed using a set of stable proteins including cytochrome c, myoglobin and lysozyme with two different types of aqueous-aqueous polymer phase systems, i.e., PEG (polyethylene glycol) 1000-dibasic potassium phosphate, and PEG 8000-dextran T500 in 5 mM potassium phosphate buffer. Using a set of multilayer coiled columns prepared from 0.8 mm I.D. PTFE tubing with different volumes (11, 24, 39 ml), the effect of the column capacity on the partition efficiency was investigated under a given set of experimental conditions. Among these experiments, the best separation of proteins was attained using the 39 ml capacity column with a 12.5% (w/w) PEG 1000-12.5% (w/w) dibasic potassium phosphate system at 10 rpm of coil rotation under 800 rpm. With lower phase mobile at 0.2 ml/min in the head-to-tail elution, the resolution between cytochrome c and myoglobin was 1.6 and that between myoglobin and lysozyme, 1.9. With upper phase mobile in the head-to-tail elution, the resolution between lysozyme and myoglobin peaks was 1.5. In these two separations, the stationary phase retention was 35.0 and 33.3%, respectively. Further studies were carried out using a pair of eccentric coil assemblies with 0.8 mm I.D. PTFE tubing at a total capacity of 20 ml. A comparable resolution was obtained using both lower and upper phases as a mobile phase in a head-to-tail elution. The results of our studies demonstrate that the nonsynchronous CPC is useful for protein separation with aqueous-aqueous polymer phase systems.  相似文献   

12.
The chiral separation of loxoprofen was achieved on a chiral column with UV and circular dichroism (CD) detection. The good resolution of four loxoprofen stereoisomers was obtained. The column used for the chiral separation was Chiralcel OJ column (250 x 4.6 mm) using hexane-2-propanol-trifluoroacetic acid (95:5:0.1), as an eluent. The flow-rate was 1.0 ml/min and the detection was at 225 nm. In addition, CD and UV spectra were obtained by stopped flow scanning. The method allows the determination of the stereoisomers of loxoprofen in human plasma after the administration of therapeutic dose of the racemic drug, thus HPLC with CD detector is useful for the stereospecific determination of loxoprofen products in biological samples.  相似文献   

13.
Bhoir IC  Patil ST  Sundaresan M 《Talanta》1999,48(5):435-1189
Studies of speed, resolution, and selectivity have shown that packed column supercritical fluid chromatography (PCSFC) is a viable technique for the isocratic, isothermal and isobaric separation of seven anticonvulsants, viz., phenobarbitone, phenytoin sodium, phethenylate sodium, nitrazepam, clonazepam, carbamazepine, and primidone, and their simultaneous estimation. The drugs were eluted from a JASCO, RP-C18 (250×4.6 mm) 10 μ packed column with a binary mobile phase of carbon dioxide and methanol, using ibuprofen as the internal standard. The effect of pressure, temperature, modifier concentration, and the rate of flow of CO2 on retention and selectivity of all the analytes were studied and the parameters optimised. Without methanol in the mobile phase none of the solutes eluted. Changing modifier concentration was the most effective physical parameter for changing retention and selectivity. The analytes were detected using a UV detector at 215 nm. An arbitrary mixture of eight components was baseline resolved in 7 min. The study includes a successful attempt at quantification of the drugs. Chromatographic and analytical figures of merit have been listed. The present work holds promise for a possible replacement of HPLC with SFC for the separation and assay of drugs of different families.  相似文献   

14.
Ramosetron is an enantiopure active pharmaceutical ingredient marketed in Japan since 1996 and later in a few Southeast Asian countries predominantly as an antiemetic for patients receiving chemotherapy. In this study, a simple and rapid high‐performance liquid chromoatography method for the separation of ramosetron and its related enantiomeric impurity by using hydrophilic interaction liquid chromatography mode is presented. Chiral resolution was performed on an analytical column (100 mm × 4.6 mm id) packed with 3 μm particles of cellulose‐based Chiralpak IC‐3 chiral stationary phase. Using a mobile phase containing acetonitrile–water–diethylamine (100:10:0.1, v/v/v) and setting the column temperature at 35°C, the resolution value was 7.35. At a flow rate of 1 mL/min, the enantioseparation was completed within 5 min. The proposed method was partially validated and it has proven to be sensitive with limit of detection and limit of quantitation of the (S)‐enantiomer impurity of 44.5 and 133.6 ng/mL.  相似文献   

15.
A rapid and sensitive analytical method for udenafil in rat plasma was developed and validated using liquid chromatography-tandem mass spectrometry (LC-MS/MS). This chromatographic procedure was then applied to the in vivo pharmacokinetic studies in rats for determining the advantages of intranasal administration of the drug over oral administration. Using liquid-liquid extraction (LLE), udenafil and the internal standard (IS) sildenafil were extracted with dichloromethane from 100 μl of plasma samples. Chromatographic separation was performed using Pursuit XRS C?? column (50 mm × 2.1 mm, i.d., 3 μm, Varian Inc., CA, U.S.A.) with an isocratic mobile phase consisting of acetonitrile and 10 mM ammonium acetate (90 : 10, v/v) at a flow rate of 0.2 ml/min over a total run time of 2.5 min. Detection and quantification was performed by mass spectrometry using the multiple reaction-monitoring mode at m/z 517.4→283.1 for udenafil and m/z 475.3→100.0 for IS. Results showed that the developed method was sensitive and specific for udenafil. Linearity was obtained in the range of 0.5-1000 ng/ml. The coefficient of variation of both intra- and inter-day validation were below 11.6% and the intra- and inter-day accuracy ranged from 91.5 to 109.9%. Udenafil concentration was successfully measured from plasma after intranasal as well as after intravenous or oral administration at clinical dose (1.67 mg/kg) in rats. Moreover, the T(max) values obtained from pharmacokinetic studies suggested that administration of udenafil intranasally could be more effective than by the oral route.  相似文献   

16.
《Analytical letters》2012,45(11):2513-2524
Abstract

A high-performance liquid chromatographic technique for the separation of the optical isomers of salsolinol is described. The simple and rapid method allows the direct resolution of the enantiomers without derivatization. A complete separation (baseline resolution) of (R)-(+)-salsolinol and (S)-(-)-salsolinol could be achieved on a Chiral=Si 100 ß-cyclodextrin column using water mixed with 10% methanol (v/v) and 0.05% trifluoroacetic acid (v/v) as mobile phase. Analyses carried out at a flow rate of 1.0 ml/min were accomplished in less than 12 minutes.  相似文献   

17.
刘永玲  陈涛  陈晨  邹登朗  李玉林 《色谱》2014,32(5):543-546
采用高速逆流色谱(HSCCC)技术从铁棒锤根氯仿提取物中分离制备了一种高纯度咪唑类生物碱1H-imidazole-2-carboxylic acid,butyl ester (ICABE)。采用高效液相色谱(HPLC)测定目标化合物在两相溶剂中的分配系数,优化HSCCC分离ICABE的溶剂体系,确定了以正己烷-氯仿-乙醇-水(10:1:13:2,v/v/v/v)为HSCCC的两相溶剂系统,以上相为固定相,下相为流动相,流动相流速为1.8 mL/min,主机转速850 r/min,检测波长为230 nm条件下进行分离制备,在350 min内从100 mg粗样品中一步分离得到7.5 mg ICABE,经HPLC检测其纯度达98%以上(峰面积归一化法),结构由UV、1H-NMR和13C-NMR得以鉴定。该方法简便、快速,所得产物纯度高,适合于铁棒锤中ICABE的制备分离。  相似文献   

18.
Ma S  Chen L  Luo G  Ren K  Wu J  Wang Y 《Journal of chromatography. A》2006,1127(1-2):207-213
A comprehensive two-dimensional liquid chromatography system was constructed on the combination of size exclusion chromatography (SEC) and reverse phase liquid chromatography (RPLC). The first dimension used a SEC column with 300 mm x 8mm i.d., packed with Toyopearl HW-40S. The column was eluted with 0.05 mol/l Tris-HCl (pH 6.9) at a flow rate of 0.4 ml/min. The second dimension used a RPLC column with 100 mm x 4.6mm i.d., which was operated in gradient form at a flow rate of 1.0 ml/min. An automatic switching valve was used to collect the effluent of the SEC column every 3 min, and the effluent was automatically injected into the RPLC column. Mass spectrometer was used for peak identification. This system was used to separate Qingkailing injection, a traditional Chinese medicine (TCM). The result showed that the total peak capacity of this system could reach 1134 and the qualitative analysis of seven chemical components of the Qingkailing injection was accomplished by this system. The results show that comprehensive two-dimensional liquid chromatography system is of great importance and high value in the separation of complex TCM.  相似文献   

19.
Yang C  Wei Y  Zhang Q  Zhang W  Li T  Hu H  Zhang Y 《Talanta》2005,66(2):472-478
In this study, a 38 mL monolith with homogeneous porous structure was produced by a single polymerization from glycidyl methacrylate (GMA) and ethylene dimethacrylate (EDMA) in the presence of porogens and an initiator. The uniform temperature distribution within the reaction system was achieved by adding reactant mixture continuously and enhancing the heat transfer ability of the polymerization system. Homogeneous porous structure in the monolith was proved by SEM and the pore size distribution profiles measured by mercury intrusion porosimetry. Experimental results from proteins separation indicated that the dynamic capacity and resolution of radial flow monolithic column were independent of flow rates. Furthermore, the pressure drop on the column was linearly dependent on the flow rate and did not exceed 1.7 MPa even at a flow rate of 50 mL/min, which proved that the prepared monolith could be used in the quick separation and preparation of biopolymers.  相似文献   

20.
建立了用高速逆流色谱从蝙蝠蛾拟青霉中高效、快速分离制备高纯度麦角甾醇的方法。将蝙蝠蛾拟青霉的乙酸乙酯提取物直接进行高速逆流色谱分离,考察了不同溶剂系统的分离效果。结果表明,最佳的溶剂系统为正己烷-乙酸乙酯-甲醇-水(体积比为6:1.7:6:0.3),以上相为固定相,下相为流动相,转速为850 r/min,流速为2 mL/min,检测波长为280 nm。制备所得的麦角甾醇经紫外光谱(UV)和高分辨质谱(HRMS)鉴定及与标准品对照定性;纯度经高效液相色谱(HPLC)分析为99.2%(峰面积归一化法)。该方法制备麦角甾醇简便、快速,所得产物的纯度高,适合于麦角甾醇对照品的制备。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏