首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 500 毫秒
1.
A computer model has been developed that is able to predict the performance of a quadrupole mass spectrometer (QMS) for any constant cross section electrode geometry. It has been used to predict the performance of QMS systems with both hyperbolic and circular cross section electrodes. The predictions confirm the limited previous work that indicates QMS performance is poorer when circular cross section electrodes are used rather than hyperbolic ones. There is also an indication that use of circular electrodes causes a movement of the peak position from the expected one and produces an extended tail on the low mass side of the peak. Copyright 2000 John Wiley & Sons, Ltd.  相似文献   

2.
We consider the case of a quadrupole mass spectrometer (QMS) in which a static magnetic field is applied axially in the z-direction along the length of the mass filter. The theoretical approach assumed in the model is that the QMS contains hyperbolic rods as electrodes and that the magnetic field acts over the full length of the mass filter assembly. Initial experimental results with argon and helium for a low-resolution instrument confirm the predicted theoretical trends. The analysis also predicts for which values of operating parameters an enhancement of the instrument resolution is achieved when an axial magnetic field is applied. The model predicts instrument resolution R > 3000 for a QMS with a 200 mm long mass filter via application of an axial magnetic field.  相似文献   

3.
The performance of commercial quadrupole mass spectrometers (QMS) with a number of imperfections, as compared to the ideal hyperbolic geometry, has been characterized using the computer simulation program version 6.0. The analysis of simulated QMS geometries focuses primarily on modeling of the internal potential, the study of field deviations, and the influence of finite length on performance of the QMS. The computer simulation of ion trajectories in the QMS field yields predictions for optimum working conditions and provides estimates for the resolving power and the maximum isotopic abundance sensitivity. Experimental measurements that confirm these expectations are presented. Optimization of the geometry and various operational parameters of the QMS is an important step in the development of a system for highly selective ultratrace determination using laser-based resonance ionization mass spectrometry.  相似文献   

4.
The qualitative and quantitative identification of low mass isotopes in the mass range 1–6 u poses certain difficulties when attempting to achieve the required resolution with an instrument suitable for deployment within a process environment. Certain adjacent species present in the process sample (HT and D2) require a resolution greater than 930 to achieve an accurate measurement. We demonstrate here through simulation techniques that this level of performance required is unachievable using commercially available instruments. Using previously reported simulation techniques, this article demonstrates how the required performance for resolving the low mass isotopes can be achieved by a quadrupole mass spectrometer (QMS), which incorporates a quadrupole mass filter (QMF) constructed from hyperbolic electrodes and operated in zone 3 of the Mathieu stability diagram.  相似文献   

5.
An ion trap source has been designed for use with time-of-flight (TOF) mass analysis. Two thin diaphragms make up a segmented ring electrode; the end cap electrodes are planar wire mesh. The potential field produced by the rf voltage applied between the ring and end cap electrodes resembles that of the cylindrical ion trap. The trapped ion population for ions created by electron impact exhibits linear growth against a first-order loss that has a time constant of about 50 µs; no ion loss occurs when the electron beam is off. The observed value of q z at low-mass cutoff for rf ion storage is ?0.84. Pulsed extraction of all ions is accomplished by switching the trap electrodes from rf to voltages required to provide a linear dc extraction field. The TOF flight path includes a wide energy range reflectron. Better than unit mass resolution is achieved through m/z 500 without collisional ion cooling. With an extraction rate of 1 kHz and a recording rate of 4 spectra per second, a linear working curve is obtained between 36 pg and 18 ng of chlorobenzene delivered chromatographically. The system has demonstrated the potential to achieve a very high sample utilization efficiency at high spectral generation rates.  相似文献   

6.
In this paper, we have employed an ion imaging approach to investigate the behavior of ions exiting from a quadrupole mass spectrometer (QMS) system that employs a radio frequency octopole ion guide before the QMS. An in-vacuum active pixel detector (Timepix) is employed at the exit of the QMS to image the ion patterns. The detector assembly simultaneously records the ion impact position and number of ions per pixel in every measurement frame. The transmission characteristics of the ion beam exiting the QMS are studied using this imaging detector under different operating conditions. Experimental results confirm that the ion spatial distribution exiting the QMS is heavily influenced by ion injection conditions. Furthermore, ion images from Timepix measurements of protein standards demonstrate the capability to enhance the quality of the mass spectral information and provide a detailed insight in the spatial distribution of different charge states (and hence different m/z) ions exiting the QMS.   相似文献   

7.
We report here a study using a quadrupole mass spectrometer (QMS) in which a static magnetic field is applied transversely to the body of the mass filter operating in stability zone 3. Significant improvement in QMS performance was obtained under certain magnetic field conditions, and these have been explained in terms of our theoretical model. The theoretical approach assumed in the model is that the QMS contains hyperbolic rods as electrodes and that the magnetic field acts over the full length of the mass filter assembly. Our latest analysis also predicts for what values of operating parameters an enhancement of the quadrupole resolution is achieved when a transverse magnetic field is applied. The model predicts instrument resolution R > 5000 for Ar with a 100 mm long mass filter and R > 3500 for a HT and D2 mixture with a 200 mm long mass filter via application of a transverse magnetic field.  相似文献   

8.
Positive ion methane and ammonia chemical ionization mass spectra for ten phenothiazine derivatives are reported. The fragmentations observed in the chemical ionization mass spectra are rationalized in terms of the location of the added proton. High-resolution measurements are used to confirm empirical formulae of the ions in the mass spectra. Changes in the mass spectra with a change in the chemical ionization reagent gas from methane to ammonia are described. A comparison with positive ion secondary ion mass spectra of the same compounds show that the amount of fragmentation is higher in the secondary ion mass spectra, but the same types of ions are observed in spectra produced by both ionization methods.  相似文献   

9.
This paper compares two liquid introduction atmospheric pressure ionization techniques for the analysis of alkyl ethoxysulfate (AES) anionic surfactant mixtures by mass spectrometry, i. e., electrospray ionization (ESI) in both positive and negative ion modes and atmospheric pressure chemical ionization (APCI) in positive ion mode, using a triple quadrupole mass spectrometer. Two ions are observed in ESI(+) for each individual AES component, [M + Na]+ and a “desulfated” ion [M − SO3 + H]+, whereas only one ion, [M − Na] is observed for each AES component in ESI(−). APCI(+) produces a protonated, “desulfated” ion of the form [M − NaSO3 + 2H]+ for each AES species in the mixture under low cone voltage (10 V) conditions. The mass spectral ion intensities of the individual AES components in either the series from ESI(+) or APCI(+) can be used to obtain an estimate of their relative concentrations in the mixture and of the average ethoxylate (EO) number of the sample. The precursor ions produced by either ESI(+) or ESI(−), when subjected to low-energy (50 eV) collision-induced dissociation, do not fragment to give ions that provide much structural information. The protonated, desulfated ions produced by APCI(+) form fragment ions which reveal structural information about the precursor ions, including alkyl chain length and EO number, under similar conditions. APCI(+) is less susceptible to matrix effects for quantitative work than ESI(+). Thus APCI(+) provides an additional tool for the analysis of anionic surfactants such as AES, especially in complex mixtures where tandem mass spectrometry is required for the identification of the individual components.  相似文献   

10.
Negative-ion fast atom bombardment mass spectra of hypervalent germanates silicates and titanate with the use of two matrices, glycerol and m-nitrobenzyl alcohol, were studied. In the case of germanates a complete reaction of the studied anion with glycerol is observed, so it is impossible to use such a matrix to identify these compounds. The use of m-nitrobenzyl alcohol allows spectra to be obtained that are significant with respect to the structure for all the studied compounds. However, for each compound a partial reaction of this matrix is observed. Further, in the case of doubly charged anions, the adduct ion obtained with an alkali metal cation does not show glycerol reactivity whereas such reactivity occurs from the adduct ion obtained with proton.  相似文献   

11.
The condition to cancel aberrations that result from initial ion velocities and length of ionization process by postsource pulse focusing in linear time-of-flight mass spectrometers is derived. The ion arrival time distribution as a function of ion mass is given, which permits mass scale calibration. Simple formulas allow calculation of the voltage needed for postsource pulse focusing and the limits of the mass range where the focusing action is felt. The theory is illustrated for a specific instrument case.  相似文献   

12.
The coupling of ion mobility spectrometry (IMS) instruments with mass spectrometers has been described since early in IMS development, most commonly with quadrupole mass analyzers. The recent development of IMS with time-of-flight (TOF) instruments has demonstrated that the time compatibility (IMS milliseconds and TOFMS microseconds) of the two techniques enables rapid two-dimensional separations to be performed, theoretically in the order of seconds for a complete analysis. This study presents a unique way to operate a traditional IMS/QMS system to attain separations similar to those achieved with IMS/TOF. For this new approach, the quadrupole was slowly scanned in the single-ion monitoring mode while IMS spectra were continually embedded in each m/z step. In this way, two-dimensional separations (IMS drift times and m/z) were obtained using the traditional IMS/QMS arrangement. An example of a five amino acid separation (quadrupole scan of 40 m/z values at a rate of approximately 7 steps/min) led to a complete two-dimensional analysis within 6 min, comparable to rapid chromatographic separations with mass spectrometry. Proposed approaches to reduce the analysis time are discussed and a reduction in the analysis time to less than 1 min is feasible when the IMS/QMS separation conditions are optimized.  相似文献   

13.
The protein calmodulin (apoCaM) undergoes a conformational change when it binds calcium. This structure of the protein (Ca4CaM) is a dumbbell-shaped molecule that undergoes a further profound conformational change on binding of the antipsychotic drug trifluoperazine (TFP). Experimental conditions were developed to prepare samples of apoCaM, Ca4CaM and Ca4CaM/TFP that were substantially free of sodium. The effects of the conformational changes of calmodulin on the charge-state distributions observed in positive ion and negative ion electrospray ionization (ESI) mass spectra were examined. Conversion of apoCaM into Ca4CaM was concomitant with a change in the negative ion ESI mass spectrum whereby the 16- ion was the most abundant ion observed for the apo form and the 8- ion was the most abundant for the complex. In contrast, in the positive ion ESI mass spectra of apoCaM and Ca4CaM, the most abundant species in each case was the 8+ ion. When a complex of Ca4CaMwith TFP was prepared, the most abundant species was the 5+ ion. This is consistent with a conformational change of Ca4CaM that rendered some basic sites inaccessible to ionization in the ESI process. Using the same Ca4CaM/TFP mixture, no complex with TFP was observed in negative ion ESI mass spectra. These observations are discussed in the context of the structural changes that are known to occur in calmodulin, and suggestions are made to explain the apparently conflicting data. The results reported here reflect on the validity of using differences in charge-state distributions observed in ESI mass spectra to assess conformational changes in proteins.  相似文献   

14.
Ions derived from negative electrospray ionization of polyamidoamine (PAMAM) dendrimer generation 0.5 were subjected to ion trap tandem mass spectrometry. Ion/ion proton transfer reactions were used to manipulate the charge states of PAMAM precursor ions to form lower charge states from those initially formed by electrospray, as well as to facilitate the interpretation of the product ion mass spectra. Most of the products derived from dendrimer precursor ions could be rationalized by retro-Michael decomposition reactions. The dominant fragmentation channels are highly dependent on the composition of the counter-ions, which in this case are restricted to different numbers of sodium ions and protons, and whether the precursor ion is multiply charged or singly charged. An interpretation is given that is consistent with all of the observations made with the various anions associated with this study. The nature of the structural information that can be obtained via ion trap tandem mass spectrometry of the dendrimers is dependent on the types of precursor ions subjected to study. The tandem mass spectrometry data also provided information about the structure of faulty synthesis products present in the PAMAM dendrimer sample.  相似文献   

15.
Lopes NP  Stark CB  Gates PJ  Staunton J 《The Analyst》2002,127(4):503-506
Monensin A was studied by electrospray ionisation sequential mass spectrometry (ESI-MSn) and all fragments were confirmed by accurate-mass measurements. Analyses were performed on both a quadrupole time-of-flight (Q-tof) and a Fourier-transform ion cyclotron resonance (FT-ICR) mass spectrometer. MSn analysis shows that depending on sample preparation the ion at m/z 671 consists of two different ions with the same accurate-mass. It is either the monensin protonated parent ion or a different ion structure derived from the loss of water from the water adduct of monensin. Both ions show different fragmentation patterns. Major fragment ions from the protonated parent ion were produced by Grob-Wharton type fragmentations in addition to various simple neutral losses. The fragmentation pathways of the two different m/z 671 ions are proposed.  相似文献   

16.
The performance of an energy sensitive, niobium superconducting tunnel junction (STJ) detector is investigated by measuring the pulse height produced by impacting molecular and atomic ions at different kinetic energies. Ions are produced by laser desorption and matrix-assisted laser desorption in a time-of-flight mass spectrometer. Our results show that the STJ detector pulse height decreases for increasing molecular ion mass, passes through a minimum at around 2000 Da, and then increases with increasing mass of molecular ions above 2000 Da. The detector does not show a decline in sensitivity for high mass ions as is observed with microchannel plate ion detectors. These detector plus height measurements are discussed in terms of several physical mechanisms involved in an ion-surface collision.  相似文献   

17.
It is well known that superimposition of some positive octopole field will benefit the performance of ion trap mass analyzer. In the radial‐ejection linear ion trap (LIT), adding some octopole field component to the main quadrupole field is usually accomplished by stretching the ejection rod pair. In this study, the effect of octopole potential and some other higher order potential on the performance of LIT mass analyzer is investigated. A simple and effective method, which is to add some octopole component by building a LIT with a pair of rectangular electrodes and a pair of semi‐circular electrodes, is reported. Its properties were studied by numerical simulations and experiments. The results showed that a certain amount of positive octopole component could be produced by simply adjusting the position and width of the rectangular electrodes. A resolution of over 1200 at m/z 609 (~1600 Da/s) was observed in this type of LIT. They also performed tandem mass spectrometry well. The device with optimum geometry for ion ejection from rectangular electrodes provided comparable performance to that for ion ejection from semi‐circular electrodes. This type of LIT design is easy for fabrication and assembly. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

18.
Electrospray mass spectra of multiply charged protein molecules show two distinct charge state distributions proposed to correspond to a more highly charged, open conformational form and a lower charged, folded form. Elastic collisions carried out in the radiofrequency-only collision cell of a triple quadrupole mass spectrometer have dramatic effects on the appearance of the mass spectra. The different cross sectional areas of the conformers allow preferential selection of one charge state distribution over the other on the basis of ion mobility. Preferential selection is dependent on the nature and pressure of the target gas as well as the nature of the protein. In the case of positively charged horse heart apomyoglobin (MW 16,951 da), a high charge state distribution centered around (M + 20H)20+ predominates at low target gas pressures and a second distribution centered around (M + 10H)10+ predominates at high target gas pressures. Bimodal distributions are observed at intermediate pressures and, remarkably, charge states between the two distributions are not effectively populated under most of the conditions examined. Hard sphere collision calculations show large differences in collision frequencies and in the corresponding kinetic energy losses for the two conformational states and they demonstrate that the observed charge state selectivity can be explained through elastic collisions.  相似文献   

19.
Rules for the behavior under fast atom bombardment (FAB) have been established for 15 cationic dyes — quaternary ammonium salts of heterocyclic amines and heterocycles containing quaternary nitrogen atoms with aliphatic substituents. Intense peaks corresponding to the molecular mass of the cationic part of the dyes [M-Hal]+ are observed in the spectra of all the derivatives. Fragmentation of the azodyes is determined by the azo group and the heterocyle. The base peaks in the case of compounds containing a quaternary nitrogen atom with aliphatic substituents correspond to the ammonium ion and a fragment of amine type. The results obtained can be used to identify dyes of unknown structure from their secondary ion mass spectra (SIMS).DeceasedTranslated from Khimiya Geterotsiklicheskikh Soedinenii, No. 10, 1411–1417, October, 1992  相似文献   

20.
Modelling techniques have previously predicted the observed behaviour of perfectly manufactured QMS mass filters. These methods are extended to examination of the behaviour of imperfect QMS filters; this examination considers the behaviour of QMS filters with one rod displaced radially inward as this is a simple manufacturing defect that arises when a rod does not fit correctly into the mounting.The results demonstrate the well known, but poorly documented property, that exchanging the connections of a poorly performing QMS device sometimes improves performance. This is shown to arise because only a displacement of a y-rod produces a large effect. The results also show that displacement of a y-rod may produce a spurious additional peak known as a precursor. More detailed investigation suggests that precursors are not separate peaks but are formed because a section of the main peak is removed causing an apparent double peak.Finally results confirm that adjustment of the voltage applied to a displaced rod can be used to significantly improve the QMS behaviour. A small change by a fraction alpha in the position of a single rod may be compensated by a change of 2 x alpha in the voltage applied to that rod.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号