首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Targeted absolute protein quantification yields valuable information about physiological adaptation of organisms and is thereby of high interest. Especially for this purpose, two proteomic mass spectrometry-based techniques namely selective reaction monitoring (SRM) and precursor reaction monitoring (PRM) are commonly applied. The objective of this study was to establish an optimal quantification assay for proteins with the focus on those involved in housekeeping functions and putative reductive dehalogenase proteins from the strictly anaerobic bacterium Dehalococcoides mccartyi strain CBDB1. This microbe is small and slow-growing; hence, it provides little biomass for comprehensive proteomic analysis. We therefore compared SRM and PRM techniques. Eleven peptides were successfully quantified by both methods. In addition, six peptides were solely quantified by SRM and four by PRM, respectively. Peptides were spiked into a background of Escherichia coli lysate and the majority of peptides were quantifiable down to 500 amol absolute on column by both methods. Peptide quantification in CBDB1 lysate resulted in the detection of 15 peptides using SRM and 14 peptides with the PRM assay. Resulting quantification of five dehalogenases revealed copy numbers of <10 to 115 protein molecules per cell indicating clear differences in abundance of RdhA proteins during growth on hexachlorobenzene. Our results indicated that both methods show comparable sensitivity and that the combination of the mass spectrometry assays resulted in higher peptide coverage and thus more reliable protein quantification.
Figure
Dehalococcoides mccartyi strain CBDB1 cultivated on hexachlorobenzene were used to compare two targeted peptide quantification assays for reductive dehalogenases, namely selective reaction monitoring (SRM) and precursor reaction monitoring (PRM)  相似文献   

2.
In all biological systems, protein amount is a function of the rate of production and clearance. The speed of a response to a disturbance in protein homeostasis is determined by turnover rate. Quantifying alterations in protein synthesis and clearance rates is vital to understanding disease pathogenesis (e.g., aging, inflammation). No methods currently exist for quantifying production and clearance rates of low-abundance (femtomole) proteins in vivo. We describe a novel, mass spectrometry-based method for quantitating low-abundance protein synthesis and clearance rates in vitro and in vivo in animals and humans. The utility of this method is demonstrated with amyloid-beta (Abeta), an important low-abundance protein involved in Alzheimer's disease pathogenesis. We used in vivo stable isotope labeling, immunoprecipitation of Abeta from cerebrospinal fluid, and quantitative liquid chromatography electrospray-ionization tandem mass spectrometry (LC-ESI-tandem MS) to quantify human Abeta protein production and clearance rates. The method is sensitive and specific for stable isotope-labeled amino acid incorporation into CNS Abeta (+/-1% accuracy). This in vivo method can be used to identify pathophysiologic changes in protein metabolism and may serve as a biomarker for monitoring disease risk, progression, or response to novel therapeutic agents. The technique is adaptable to other macromolecules, such as carbohydrates or lipids.  相似文献   

3.
建立了定量肽段串联体蛋白质(concatamers of Q peptides, QconCATs)结合18O同位素标记-多反应监测质谱的蛋白质绝对定量新方法。首先对QconCAT重组蛋白质进行了纯度表征,十二烷基硫酸钠-聚丙烯酰胺凝胶电泳(SDS-PAGE)表征结果表明重组蛋白质的纯度在99%以上,相对分子质量约为63.4 kDa。对QconCAT重组蛋白质酶切后的肽段混合物进行质谱分析,并经pFind和pLabel软件处理,验证了目标肽段。还考察了QconCAT重组蛋白质的酶切效率和18O标记效率,并对QconCAT蛋白质结合18O标记-同位素稀释-多反应监测质谱方法进行了评价。实验结果表明,采用该方法对腾冲嗜热厌氧菌(Thermoanaerobacter tengcongensis, TTE)中选定蛋白质的肽段进行绝对含量测定时,相对标准偏差小于20%,准确度较高,说明该方法可用于复杂生物样本中蛋白质的绝对定量。更重要的是所建方法不仅解决了细胞培养氨基酸稳定同位素标记(SILAC)技术的重标试剂价格昂贵的问题,也为定量蛋白质组学提供了一种新的方法。  相似文献   

4.
Energy-resolved mass spectrometry (ERMS) and an isotopically labelled internal standard were successfully combined to accurately quantify a tryptic peptide despite the presence of an isobaric interference. For this purpose, electrospray ionisation tandem mass spectrometry (ESI-MS/MS) experiments were conducted into an ion trap instrument using an unconventional 8 m/z broadband isolation window, which encompassed both the tryptic peptide and its internal standard. Interference removal was assessed by determining an excitation voltage that was high enough to maintain a constant value for the analyte/internal standard peaks intensity ratio, thus ensuring accurate quantification even in the presence of isobaric contamination. Pseudo-multiple reaction monitoring (MRM) was employed above this excitation voltage to quantify the trypic peptide. The internal standard calibration model showed no lack of fit and exhibited a linear dynamic range from 0.5 μM up to 2.5 μM. The detection limit was 0.08 μM. The accuracy of the method was evaluated by quantifying the tryptic peptide of three reference samples intentionally contaminated with the isobaric interference. All the reference samples were accurately quantified with ∼1% deviation despite the isobaric contamination. Furthermore, we have demonstrated that this methodology can also be applied to quantify the isobaric peptide by standard additions down to 0.2 μM. Finally, liquid chromatography ERMS (LC ERMS) experiments yielded similar results, suggesting the potential of the proposed methodology for analysing complex samples.  相似文献   

5.
A new liquid chromatography/mass spectrometry (LC/MS) method is described for relative quantification of phosphoproteins to simultaneously compare the phosphorylation status of proteins under two different conditions. Quantification was achieved by beta-elimination of phosphate from phospho-Ser/Thr followed by Micheal addition of ethanethiol and/or ethane-d(5)-thiol selectively at the vinyl moiety of dehydroalanine and dehydroamino-2-butyric acid. The method was evaluated using the model phosphoprotein alpha(S1)-casein, for which three phosphopeptides were found after tryptic digestion. Reproducibility of the relative quantification of seven independent replicates was found to be 11% SD. The dynamic range covered two orders of magnitude, and quantification was linear for mixtures of 0 to 100% alpha(S1)-casein and dephospho-alpha(S1)-casein (R(2) = 0.986). Additionally, the method allowed protein identification and determination of the phosphorylation sites via MS/MS fragmentation.  相似文献   

6.
The N-terminal amino acids of proteins are important structure units for maintaining the biological function, localization, and interaction networks of proteins. Under different biological conditions, one or several N-terminal amino acids could be cleaved from an intact protein due to processes, such as proteolysis, resulting in the change of protein properties. Thus, the ability to quantify the N-terminal truncated forms of proteins is of great importance, particularly in the area of development and production of protein-based drugs where the relative quantity of the intact protein and its truncated form needs to be monitored. In this work, we describe a rapid method for absolute quantification of protein mixtures containing intact and N-terminal truncated proteins. This method is based on dansylation labeling of the N-terminal amino acids of proteins, followed by microwave-assisted acid hydrolysis of the proteins into amino acids. It is shown that dansyl labeled amino acids are stable in acidic conditions and can be quantified by liquid chromatography mass spectrometry (LC–MS) with the use of isotope analog standards.  相似文献   

7.
Collagens are highly abundant mammalian proteins that contain a high content of hydroxylated amino acids such as hydroxyproline. We have exploited the high hydroxyproline content of collagen and developed a method for hydroxyproline quantification as a measure of collagen content in muscle samples. The novel method utilizes a highly selective and sensitive method of multiple reaction monitoring (MRM) by mass spectrometry. The analytical method is simple, rapid (5min), convenient (no derivatization), precise (<17% RSD), accurate (90-108%), sensitive (4.88nmol/L) and linear (R(2)>0.999) over three orders of magnitude (5-5000nmol/L).  相似文献   

8.
9.
A method using reversed-phase liquid chromatography coupled with electrospray ionization and selected reaction monitoring mass spectrometry has been developed for the quantitative analysis of ganciclovir in rat plasma. Acyclovir, a structurally related analog of ganciclovir, was used as the internal standard. A small volume of plasma (50 microL) was spiked with the internal standard and plasma proteins were precipitated by methanol. The supernatant was dried under nitrogen, and then reconstituted in water. The use of liquid chromatography/selected reaction monitoring/mass spectrometry effectively eliminated potential interference from endogenous constituents in the plasma. This highly selective and sensitive method made it possible to analyze plasma ganciclovir with a lower limit of quantitation of 10 ng/mL. The assay was reproducible and linear in the range 10-10,000 ng/mL. The precision and accuracy values were in the range 2.0-6.9% and 89.0-109.6%, respectively. The analyte recovery was greater than 88%. This method was successfully used to monitor the pharmacokinetic profile of ganciclovir in normal rats following intraperitoneal administration of the drug.  相似文献   

10.
Taking the labeling reaction of horse heart cytochrome c or ubiquitin with biotinamidocaproate N-hydroxysucchinimide ester (biotin-NHS) as test cases, this report demonstrates the usefulness of matrix-assisted laser desorption/ionization (MALDI) mass spectrometry for in-situ monitoring of the labeling process and for determining the composition of the labeled products without the need for prior separation. The effects of pH and starting materials concentration on the labeling process were investigated in detail. Our MALDI MS results show that: (1) labeled products are always mixtures of different conjugates, which may explain peak broadening found in chromatographic studies of labeling reactions; (2) the higher conjugate fractions become more prominent as the labeling reaction proceeds, with a concomitant exponential decline of the lower conjugate fractions; (3) biotin-NHS can be incorporated into peptides and protein in a stepwise and controlled manner simply by adjusting the molar ratio of the starting materials.  相似文献   

11.
Taking the labeling reaction of horse heart cytochrome c or ubiquitin with biotinamidocaproate N-hydroxysucchinimide ester (biotin-NHS) as test cases, this report demonstrates the usefulness of matrix-assisted laser desorption/ionization (MALDI) mass spectrometry for in-situ monitoring of the labeling process and for determining the composition of the labeled products without the need for prior separation. The effects of pH and starting materials concentration on the labeling process were investigated in detail. Our MALDI MS results show that: (1) labeled products are always mixtures of different conjugates, which may explain peak broadening found in chromatographic studies of labeling reactions; (2) the higher conjugate fractions become more prominent as the labeling reaction proceeds, with a concomitant exponential decline of the lower conjugate fractions; (3) biotin-NHS can be incorporated into peptides and protein in a stepwise and controlled manner simply by adjusting the molar ratio of the starting materials.  相似文献   

12.
Silkworm (Bombyx mori) is a very useful target insect for evaluation of endocrine disruptor chemicals (EDCs) due to mature breeding techniques, complete endocrine system and broad basic knowledge on developmental biology. Comparative metabolomics of silkworms with and without EDC exposure offers another dimension of studying EDCs. In this work, we report a workflow on metabolomic profiling of silkworm hemolymph based on high-performance chemical isotope labeling (CIL) liquid chromatography mass spectrometry (LC-MS) and demonstrate its application in studying the metabolic changes associated with the pesticide dichlorodiphenyltrichloroethane (DDT) exposure in silkworm. Hemolymph samples were taken from mature silkworms after growing on diet that contained DDT at four different concentrations (1, 0.1, 0.01, 0.001 ppm) as well as on diet without DDT as controls. They were subjected to differential 12C-/13C-dansyl labeling of the amine/phenol submetabolome, LC-UV quantification of the total amount of labeled metabolites for sample normalization, and LC-MS detection and relative quantification of individual metabolites in comparative samples. The total concentration of labeled metabolites did not show any significant change between four DDT-treatment groups and one control group. Multivariate statistical analysis of the metabolome data set showed that there was a distinct metabolomic separation between the five groups. Out of the 2044 detected peak pairs, 338 and 1471 metabolites have been putatively identified against the HMDB database and the EML library, respectively. 65 metabolites were identified by the dansyl library searching based on the accurate mass and retention time. Among the 65 identified metabolites, 33 positive metabolites had changes of greater than 1.20-fold or less than 0.83-fold in one or more groups with p-value of smaller than 0.05. Several useful biomarkers including serine, methionine, tryptophan, asymmetric dimethylarginine, N-Methyl-D-aspartic and tyrosine were identified. The changes of these biomarkers were likely due to the disruption of the endocrine system of silkworm by DDT. This work illustrates that the method of CIL LC-MS is useful to generate quantitative submetabolome profiles from a small volume of silkworm hemolymph with much higher coverage than conventional LC-MS methods, thereby facilitating the discovery of potential metabolite biomarkers related to EDC or other chemical exposure.  相似文献   

13.
The inverse labeling/mass spectrometry strategy has been applied to protein metabolic (15)N labeling for gel-free proteomics to achieve the rapid identification of protein markers/targets. Inverse labeling involves culturing both the perturbed (by disease or by a drug treatment) and control samples each in two separate pools of normal and (15)N-enriched culture media such that four pools are produced as opposed to two in a conventional labeling approach. The inverse labeling is then achieved by combining the normal (14)N-control with the (15)N-perturbed sample, and the (15)N-control with the (14)N-perturbed sample. Both mixtures are then proteolyzed and analyzed by mass spectrometry (coupled with on-line or off-line separation). Inverse labeling overcomes difficulties associated with protein metabolic labeling with regard to isotopic peak correlation and data interpretation in the single-experiment approach (due to the non-predictable/variable mass difference). When two data sets from inverse labeling are compared, proteins of differential expression are readily recognized by a characteristic inverse labeling pattern or apparent qualitative mass shifts between the two inverse labeling analyses. MS/MS fragmentation data provide further confirmation and are subsequently used to search protein databases for protein identification. The methodology has been applied successfully to two model systems in this study. Utilizing the inverse labeling strategy, one can use any mass spectrometer of standard unit resolution, and acquire only the minimum, essential data to achieve the rapid and unambiguous identification of differentially expressed protein markers/targets. The strategy permits quick focus on the signals of differentially expressed proteins. It eliminates the detection ambiguities caused by the dynamic range of detection. Finally, inverse labeling enables the detection of covalent changes of proteins responding to a perturbation that one might fail to distinguish with a conventional labeling experiment.  相似文献   

14.
A new interface for the on-line coupling of a liquid chromatograph to a stable isotope ratio mass spectrometer has been developed and tested. The interface is usable for (13)C/(12)C determination of organic compounds, allowing measurement of small changes in (13)C abundance in individual analyte species. All of the carbon in each analyte is quantitatively converted into CO(2) while the analyte is still dissolved in the aqueous liquid phase. This is accomplished by an oxidizing agent such as ammonium peroxodisulfate. The CO(2) is separated from the liquid phase and transferred to the mass spectrometer. It is shown that the whole integrated process does not introduce isotope fractionation. The measured carbon isotope ratios are accurate and reproducible. The sensitivity of the complete system allows isotope ratio determination down to 400 ng of compound on-column. By-passing the high-performance liquid chromatography (HPLC) separation allows bulk isotopic analysis with substantially lower sample amounts than those required by conventional elemental analyzers. The results of the first applications to amino acids, carbohydrates, and drugs, eluted from various types of HPLC columns, are presented. The wide range of chromatographic methods enables the analysis of compounds never before amenable to isotope ratio mass spectrometry techniques and may lead to the development of many new assays.  相似文献   

15.
Negative health effects of uranium taken into the human body are related to both the chemical toxicity of the metal and its radioactivity. A simple and reliable isotope dilution ICP-MS uranium bioassay technique was developed in this study. Use of this technique at Los Alamos National Laboratory has not been previously described. Dilute urine was introduced to a Perkin Elmer DRC II quadrupole ICP-MS via a PFA high solids nebulizer and a PFA cyclonic spray chamber cooled to 2 °C. Urine samples acidified, digested, and diluted 5× generate a solution that is roughly 10% HNO3 that can be analyzed by ICP-MS to measure uranium concentrations >54 pg/mL and uranium isotopic ratios with high enough precision and accuracy to determine if the uranium in a urine sample is natural. A three-stage rinsing routine is run between each sample to minimize urine salt deposition and uranium memory effects. Regular use of this rinsing routine minimizes instrumental drift and has produced a running 238U background of <7 cps.  相似文献   

16.
The effects of microwave irradiation on the staining of electrophoresed and electroblotted proteins have been assessed using currently available detection methods. Although the absorption of microwave radiation was found to be uneven, band intensity following microwave-assisted protein staining (MAPS) was comparable and in some cases exceeded the intensity of the bands visualised by the original staining methods. It was found that microwave treatment drastically reduced the duration of the staining protocols for visualisation of the proteins separated by both one- and two-dimensional electrophoresis. Application of MAPS methods did not affect peptide mass fingerprinting analysis by mass spectrometry and subsequent identification of the protein by database searching. The peptide mass maps corresponding to the proteins visualised using both the conventional and MAPS methods did not show significant difference in signal/noise ratio. Moreover, it appeared that microwave treatment of the gels resulted in the increased recovery of the peptides following in-gel trypsin digestion. Briefly, microwave-assisted protein staining methods were rapid, compatible with mass spectrometry and were equally effective on thin (0.75-mm) and thick (1.5-mm) gels (such as those used in 2D electrophoresis).  相似文献   

17.
18.
An improvement to the procedure for the rapid optimisation of mass spectrometry (PROMS), for the development of multiple reaction methods (MRM) for quantitative bioanalytical liquid chromatography/tandem mass spectrometry (LC/MS/MS), is presented. PROMS is an automated protocol that uses flow-injection analysis (FIA) and AppleScripts to create methods and acquire the data for optimisation. The protocol determines the optimum orifice potential, the MRM conditions for each compound, and finally creates the MRM methods needed for sample analysis. The sensitivities of the MRM methods created by PROMS approach those created manually. MRM method development using PROMS currently takes less than three minutes per compound compared to at least fifteen minutes manually. To further enhance throughput, approaches to MRM optimisation using one injection per compound, two injections per pool of five compounds and one injection per pool of five compounds have been investigated. No significant difference in the optimised instrumental parameters for MRM methods were found between the original PROMS approach and these new methods, which are up to ten times faster. The time taken for an AppleScript to determine the optimum conditions and build the MRM methods is the same with all approaches.  相似文献   

19.
Two peptide quantification strategies, the isobaric tags for relative or absolute quantitation (iTRAQ) labeling methodology and a metal-chelate labeling approach, were compared using matrix-assisted laser desorption/ionization-TOF/TOF MS and MS/MS analysis. Amino- and cysteine-directed labeling using the rare earth metal chelator 1,4,7,10-tetraazacyclododecane-N,N′,N″,N″′-tetraacetic acid (DOTA) were applied for relative quantification of single peptides and a six-protein mixture. For analyte ratios close to one, iTRAQ and amino-directed DOTA labeling delivered overall comparable results regarding accuracy and reproducibility. In contrast, the MS-based quantification via amino-directed lanthanide-DOTA tags was more accurate for analyte ratios ≥5 and offered an extended dynamic range of three orders of magnitude. Our results show that the amino-directed DOTA labeling is an alternative relative quantification tool offering advantages like flexible multiplexing possibilities and, in particular, large dynamic ranges, which should be useful in sophisticated, targeted issues, where the accurate determination of extremely different protein or peptide concentration becomes relevant.  相似文献   

20.
Selected tandem mass spectrometry (MS/MS) ion monitoring (SMIM) is the most suitable scanning mode to detect known peptides in complex samples when an ion-trap mass spectrometer is the instrument used for the analysis. In this mode, the MS detector is programmed to perform continuous MS/MS scans on one or more selected precursors, either during a selected time interval, or along the whole chromatographic run. MS/MS spectra are recorded, so virtual multiple reaction monitoring chromatogram traces for the different fragment ions can be plotted. In this work, a shotgun proteomics approach was applied to the detection of previously characterized species-specific peptides from different seafood species. The proposed methodology makes use of high intensity focused ultrasound-assisted trypsin digestion for ultra fast sample preparation, peptide separation and identification by reverse phase capillary LC coupled to an ion-trap working in the SMIM scanning mode. This methodology was applied to the differential classification of seven commercial, closely related, species of Decapoda shrimps proving to be an excellent tool for seafood product authentication, which may be used by fisheries and manufacturers to provide a fast and effective identification of the specimens, guaranteeing the quality and safety of foodstuffs to consumers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号