首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Cui H  Hua L  Hou K  Wu J  Chen P  Xie Y  Wang W  Li J  Li H 《The Analyst》2012,137(2):513-518
A home-made stir bar sorptive extraction (SBSE) apparatus was combined to a single photon ionization time-of-flight mass spectrometer (SPI-TOFMS) for rapid and sensitive determination of trace volatile organic compounds (VOCs) in water. The home-made SBSE bar, low-cost and disposable, was used for VOCs extraction. A thermal desorption (TD) device was designed to desorb the analytes from the SBSE bar, and a high throughput interface was developed to transfer the analytes into the ionization chamber of the SPI-TOFMS. The combination of large extraction volume of SBSE bar, and the direct measurement power of SPI-TOFMS enable a short analysis time for VOCs in water with high sensitivity, for example the limits of detection (LODs) were in the range of 7.4-11.1 ng L(-1) for benzene, toluene, and p-xylene (BTX) within 15 min. BTX aqueous solutions were chosen to demonstrate the quantitative capability, the linear range was from 0.05 to 100 μg L(-1) and the correlation coefficients were better than 0.996. The proposed method was successfully applied for the analysis of VOCs in urban river water.  相似文献   

2.
A new method using the extraction and preconcentration capabilities of stir bar sorptive extraction, combined with high-resolution gas chromatography and mass spectrometry, was developed for the determination of five selected endocrine-disrupting compounds (4-n-nonylphenol, bisphenol A, estrone, 17β-estradiol, and 17α-ethinylestradiol) in water. In situ derivatization to transform the phenolic compounds into lipophilic and volatile analytes was carried out with acetic anhydride. Two different methods of headspace derivatization to further improve the chromatographic properties of 17β-estradiol and 17α-ethinylestradiol were developed and compared. The optimized method provided good sensitivity (limits of quantitation 1.2–2.6 ng), repeatability (relative standard deviation 2–9%), and reproducibility (relative standard deviation 10–17%). Passive sampling by means of polar organic chemical integrative samplers was applied to monitor river waters used as supply sources for drinking water treatment plants in the Liguria region of Italy. The analytes showed a different distribution at the three sites considered; bisphenol A proved to be the most abundant, ranging from 185 to 459 ng per sampler.  相似文献   

3.
Belder D  Deege A  Kohler F  Ludwig M 《Electrophoresis》2002,23(20):3567-3573
The channels of microfluidic glass chips have been coated with poly(vinyl alcohol) (PVA). Applied for microchip electrophoresis, the coated devices exhibited a suppressed electroosmotic flow and improved separation performance. The superior performance of PVA-coated channels could be demonstrated by electrophoretic separations of labeled amines and by video microscopy. While a distorted sample zone is injected using uncoated channels the application of PVA-coated channels results in an improved shape of the sample zone with less band broadening. Applying PVA-coated microchips for the separation of amines labeled with Alexa Fluor 350 even sub-second separations, utilizing a separation length of only 650 microm, could be obtained, while this was not possible using uncoated devices. By using PVA-coated devices rather than an uncoated chip a threefold increase in separation efficiencies could be observed. As the electroosmotic flow (EOF) was suppressed, the anionic compounds were detected at the anode whereas the dominant EOF in uncoated devices resulted in an effective mobility to the cathode. Besides improved separation performance another important feature of the PVA-coated channels was the suppressed adsorption of fluorescent compounds in repetitive runs which results in an improved robustness and detection sensitivity. Applying PVA-coated channels, rinsing or etching steps could be omitted while this was necessary for a reliable operation of uncoated devices.  相似文献   

4.
A simple and rapid method for the decimilligram-scale determination of sulfur in organic compounds is described. The procedure utilizes the Schöniger flask method for the combustion and the sulfate-ion titration, with 0.01 M barium perchlorate solution and dimethylsulfonazo III as indicator. The results obtained are exact and precise.  相似文献   

5.
A stir bar sorptive extraction method for the determination of volatile compounds in orange juices was developed. The extraction variables were optimized using a reduced two‐level factorial screening design (25‐1), and the most suitable analytical conditions for the extraction of the studied compounds were: sample volume 10 mL, extraction time 60 min, stirring speed 1800 rpm, NaCl amount 30% (weight/volume), and twister length 10 mm. The optimized method was further validated, obtaining good linearity and detection and quantification limits low enough to correctly determine the studied compounds. As well, for most of the studied compounds precision and recovery values were good. Several orange juice samples (squeezed and commercial) were extracted following the optimized extraction method and analyzed by gas chromatography coupled to mass spectrometry detection. The method has proven to be suitable for the determination of the aroma of orange juice, of which limonene was the major volatile compound in all the studied samples.  相似文献   

6.
Stir bar sorptive extraction (SBSE) was evaluated for analysing volatile compounds in vinegar. The extraction and desorption analytical conditions have been optimised using a two-level factorial design expanded further to a central composite design. This chemometric tool is very appropriate in screening experiments where the aim is to investigate several possibly influential and/or interacting factors. For the extraction step, the optimum analytical conditions were: sample volume 25 ml without dilution, sampling time 120 min, NaCl content 5.85 g, and stirring speed 1250 rpm. For the desorption step, the optimised analytical conditions were: desorption temperature 300 degrees C, cryofocusing temperature -140 degrees C, flow of helium 75 ml min(-1), and desorption time 10 min. The SBSE procedure developed shows detection limits, and linear ranges adequate for analysing this type of compounds. The repeatability values obtained were lower than 10%. SBSE is a very simple, solvent-free, fast technique with better sensitivities, in general, than SPME. However, a disadvantage of this technique is that, up to now, the stir bar offers a limited enrichment capability for polar compounds because is only available with PDMS coating.  相似文献   

7.
Characterization of amino-terminated polyamidoamine dendrimers by CE suffers from a lack of resolution for higher generations and poor between-day reproducibility of retention times. Under optimal conditions of temperature, voltage, and sample amount, 0-5 generations of dendrimers could be resolved with a bare fused-silica capillary. However, reproducibility was poor due to potential interactions of the polycationic dendrimers with the uncoated quartz capillary wall. Use of a poly(vinyl alcohol)-coated capillary significantly decreased the migration times of the nanomolecules without compromising resolution. Dendrimer mixtures containing generations 0-5 are separated as discrete, nonoverlapping peaks in about 15 min. In addition, the between-day precision of retention times was dramatically improved without the need for internal standards or data normalization. Dendrimers of various generations and cores run on different days showed an RSD of retention times of less than 4%. The poly(vinyl alcohol) coating was very stable as shown by the excellent precision of migration times obtained on a capillary used for a month with more than 100 injections. Similar to PAGE, separation of polyamidoamine dendrimers on a bare fused-silica and poly(vinyl alcohol)-coated capillary showed an exponential relationship between migration times and calculated charge density of the nanomolecules.  相似文献   

8.
The states of water sorbed in a cross-linked polyethylene glycol (PEG) gel, TSKgel Ether-250, and cross-linked poly(vinyl alcohol) (PVA) gels of different pore sizes, TSKgel Toyopearl HW-40S, 50S, 55S and 75S, were investigated by means of differential scanning calorimetry (DSC). It was found that there were three types of water in these hydrogels, non-freezing water, freezable bound water and free water. The amount of water that functions as the stationary phase in the column packed with the each gel was also estimated by a liquid chromatographic method. The estimated amount of the stationary phase water is in good agreement with the sum of the amount of non-freezing water and that of freezable bound water for HW-40S, 50S and 55S, while it agrees with the amount of only non-freezing water for HW-75S and Ether-250. This means that the stationary phase water consists of non-freezing water and freezable bound water for HW-40S, 50S and 55S, while only non-freezing water functions as the stationary phase in HW-75S and Ether-250 gels. This result can be attributed to the difference in the structure of the gels; the PVA gels containing PVA at relatively high concentrations, HW-40S, 50S and 55S, have a homogeneous gel phase, whereas HW-75S and Ether-250 have a heterogeneous gel phase consisting hydrated polymer domains and macropores with relatively hydrophobic surface. The freezable bound water in Toyopearl HW-40S, 50S and 55S can be regarded as a component of a homogeneous PVA solution phase, while that in HW-75S and Ether-250 may be water isolated in small pores of the hydrophobic domains. The results obtained by the investigation on the retention selectivity of these hydrogels in aqueous solutions supported our postulated view on the structures of the hydrogels.  相似文献   

9.
Law WS  Zhao JH  Li SF 《Electrophoresis》2005,26(18):3486-3494
Field-amplified sample stacking (FASS) is used to separate basic proteins in a poly-(vinyl alcohol)-coated bubble cell capillary. To our knowledge, this is the first paper describing the on-column stacking of proteins (as cations) using FASS in bubble cell capillary. The bubble cell capillary is fabricated using a one-step method. Cetyltrimethylammonium chloride is added into the running buffer to reverse the EOF and, thus, to pump the water plug out during the sample stacking step. The effect of the water plug lengths and sample injection durations were investigated and optimized. The results obtained were compared with those for the normal capillary without bubble cell in terms of resolution and sensitivity enhancement. Under the optimal condition, this method can improve the sensitivity of the peak areas ranging from 5000- to 26 000-fold. The RSDs (n = 5) of the migration time and peak area are satisfactory (less than 0.6 and 12%, respectively). Application of the capillary electrophoresis method with bubble cell, FASS, and UV detection thereby leads to the determination of these proteins at concentrations ranging from 3 to 10 ng/mL, based on a signal-to-noise ratio of 3:1.  相似文献   

10.
A novel method for the trace analysis of 17beta-estradiol (E2) in river water sample was developed, which involved stir bar sorptive extraction (SBSE) with in situ acylation (first derivatization) and thermal desorption (TD) with quartz wool assisted (QWA) in tube silylation (second derivatization), followed by gas chromatography-mass spectrometry (GC-MS), and is called the "dual derivatization method." The optimum conditions for SBSE with in situ acylation, such as the volume of acetic acid anhydride and the extraction time, were investigated. In addition, the optimum conditions for TD with QWA in tube silylation, such as the volume of N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA) and the TD temperature and hold time, were investigated as well. The detection limit (S/N = 3) and the quantitation limit (S/N>10) of E2 in the river water sample were 0.5 and 2 pg ml(-1) (ppt), respectively, by the dual derivatization method. In addition, the detection limit was 0.1 pg ml(-1) by using dual derivatization method with multi-shot mode. The calibration curve for E2 was linear in the range of 0.002-10 ng ml(-1) with correlation coefficients >0.999. The average recoveries of E2 (n = 6) at the concentrations of 0.05 and 1.0 ng ml(-1) from the river water sample were 93.1 (RSD: 1.4%) and 98.4% (RSD: 0.8%), respectively, with correction using the added surrogate standard, 17beta-estradiol-(13)C(4). This simple, accurate, sensitive and selective analytical method may be applicable to the determination of trace amounts of E2 in water samples.  相似文献   

11.
The analysis of organic pollutants in environmental water samples requires a pre-concentration step. Pre-concentration techniques such as stir bar sorptive extraction (SBSE) have gained popularity since they minimise the use of toxic organic solvents and can be considered as green analytical techniques. Similar to other pre-concentration techniques, one of the problems when SBSE is used is the matrix effect, which often occurs during the analysis of environmental water samples such as estuarine or wastewater samples. The present work studied the matrix effect during SBSE coupled to in-tube derivatisation–thermal desorption (TD)–gas chromatography–mass spectrometry for the determination of several endocrine disruptor compounds, such as alkylphenols, bisphenol A, estrogens and sterols, in environmental water samples, after optimisation of the major variables affecting the determination. Variables such as the addition of methanol or an inert salt to the donor phase, the extraction temperature, the volume of the donor phase, the stirring rate and the extraction time were studied during the SBSE optimisation. In the case of the in-tube derivatisation and TD step, the volume of the derivatisation reagent (N,O-bis(trimethylsilyl)triufloroacetamide with 1% of trimethylchlorosilane (BSTFA + 1% TMCS)) and the cryo-focusing temperature were fixed (2 μL and −50 °C, respectively) according to a consensus between maximum signal and optimal operation conditions. Good apparent recovery values (78–124%) were obtained for most of the analytes in Milli-Q water, except for 4-tert-octylphenol (4-tOP), which showed apparent recovery values exceeding 100%. Precision (n = 4) was in the 2–27%, and method detection limits were in the low nanogrammes per litre level for most of the analytes studied. The matrix effect was studied using two different approaches. On the one hand, Milli-Q water samples were spiked with humic acids, and apparent recovery values were studied with and without correction with the corresponding deuterated analogue. On the other hand, estuarine water and wastewater samples were spiked with known concentrations of target analytes, and apparent recoveries were studied as explained above. In general, the matrix effect could be corrected with the use of deuterated analogues, except for 4-tOP and nonylphenols for which [2H4]-n-nonylphenol did not provide good corrections.  相似文献   

12.
A novel extraction procedure for stir bar sorptive extraction (SBSE) termed sequential SBSE was developed. Compared to conventional SBSE, sequential SBSE provides more uniform enrichment over the entire polarity/volatility range for organic pollutants at ultra-trace levels in water. Sequential SBSE consists of a SBSE performed sequentially on a 5-mL sample first without modifier using one stir bar, then on the same sample after addition of 30% NaCl using a second stir bar. The first extraction with unmodified sample is mainly targeting solutes with high Kow (logKow>4.0), the second extraction with modified sample solution (containing 30% NaCl) is targeting solutes with low and medium Kow (logKow<4.0). After extraction the two stir bars are placed in a single glass desorption liner and are simultaneously desorbed. The desorbed compounds were analyzed by thermal desorption and gas chromatography-mass spectrometry (TD-GC-MS). Recovery of model compounds consisting of 80 pesticides (organochlorine, carbamate, organophosphorus, pyrethroid, and others) for sequential SBSE was evaluated as a function of logKow (1.70-8.35). The recovery using sequential SBSE was compared with those of conventional SBSE with or without salt addition (30% NaCl). The sequential approach provided very good recovery in the range of 82-113% for most of the solutes, and recovery less than 80% for only five solutes with low Kow (logKow<2.5), while conventional approaches (with or without salt addition) showed less than 80% recovery for 23 and 41 solutes, respectively. The method showed good linearity (r2>0.9900) and high sensitivity (limit of detection: <10ngL(-1)) for most of the model compounds even with the scan mode in the MS. The method was successfully applied to screening of pesticides at ngL(-1) level in river water samples.  相似文献   

13.
搅拌棒吸附萃取技术与GC-MS联用测定苹果酒挥发性物质   总被引:2,自引:0,他引:2  
研究了检测苹果酒中挥发性物质的一种新方法—搅拌棒吸附萃取(简称SBSE)气质联用技术。对搅拌速度、搅拌时间、温度及加盐量对搅拌棒萃取效果的影响进行了研究。萃取条件为:10 mL苹果酒样加入3 g NaCl,于55℃下以1100 r/min的转速搅拌60 min。搅拌棒萃取出了苹果酒中80种挥发性物质,对其中的49种物质进行了定量。该方法具有良好的线性,所有标准曲线的线性相关系数均大于0.99。方法检出限为0.01~6.37μg/L,定量限为0.03~21.25μg/L,回收率在70.9%~111.4%之间,相对标准偏差均在10%以内。  相似文献   

14.
Stir bar sorptive extraction (SBSE) and thermal desorption followed by capillary gas chromatography coupled to mass spectrometry (SBSE-TD-GC-MS) was applied to the simultaneous determination of ultra-traces of 16 polycyclic aromatic hydrocarbons (PAHs), 12 polychlorinated biphenyls (PCBs), 6 phthalate esters (PEs) and 3 nonylphenols (NPs) in water samples. The parameters that could affect the sorption-desorption efficiency were studied. A Plackett-Burman design was used for the screening of the main effects of the experimental parameters related to the desorption step (desorption time, desorption temperature, desorption flow, cryo-focusing temperature and vent pressure). Afterwards, two central composite designs were used to find the optimal process settings for the extraction and desorption steps. The best analytical compromise conditions for the simultaneous determination of analytes from spiked water samples were found to be: sample volume (20 mL), sodium chloride addition (30%), methanol addition (20%), desorption time (10 min), desorption temperature (300 degrees C), desorption flow (23 mL min(-1)), cryo-focusing temperature (-50 degrees C) and vent pressure (7 psi). Remarkable recovery, repeatability and reproducibility were attained. Furthermore, excellent linearities (r(2) = 0.959-0.999) and low detection limits (0.1-10 ng L(-1)) were also achieved for the congeners studied. The proposed methodology was applied for the simultaneous determination of PAHs, PCBs, PEs and NPs in sea and estuarine waters. The influence of humic acids on the recovery was also studied.  相似文献   

15.
The isotherms of water sorption by poly(vinyl alcohol) have been obtained by static sorption methods in a wide range of vapor activities. The properties of poly(vinyl alcohol) at various values of relative humidity have been studied by DSC, X-ray diffraction analysis, and mechanical testing. It has been shown that the correct thermodynamic analysis of sorption isotherms for sorbents with complex organization requires knowledge of their structural features. A method of allowing for the effect of osmotic pressure on the polymer sorption capacity is proposed. The pair interaction parameters estimated in this study are compared with the published data.  相似文献   

16.
Poly(vinyl alcohol) (PVA) hydrogels with various water contents were prepared from 10 wt% aqueous solutions of mixtures of PVA and anionic poly(styrene sulfonic acid) sodium salt (NaPSS) by casting, dehydrating, and then extracting NaPSS. The existence of three types of ice were suggested by differential scanning calorimetry (DSC) measurements for every frozen hydrogel. In the frozen hydrogels the states of water, except unfrozen water, were ice of free water and disordered ice crystals. The mobility and activation energy for motion of water molecules in unfrozen hydrogels were investigated by using pulsed nuclear magnetic resonance (PNMR) measurements. It was concluded that there are two states of water in the unfrozen hydrogel, i.e. unfrozen water and disordered water which is mainly formed in narrow apertures in the hydrogel. The discrepancy between the DSC and PNMR measurements was explained by a structural transformation during cooling.  相似文献   

17.
Stir bar sorptive extraction (SBSE) in combination with thermodesorption-gas chromatography-mass spectrometry (TD-GC-MS) was applied for the determination of eight insect repellents and synergists in water samples. The stir bar coated with polydimethylsiloxane (PDMS) was added to 20 mL of water sample with 4 g NaCl and stirred at 1000 rpm for 180 min. Then, the stir bar was subjected to TD-GC-MS. SBSE parameters (ionic strength, presence of organic solvent and time) were optimised. Blank contamination and carryover problems were also studied. The method affords detection limits between 0.5 and 30 ng/L, except for dimethyl phthalate (DMP) (150 ng/L) due to blank contamination problems. It shows good linearity with correlation coefficients over 0.997 and reproducibility (RSD) below 20%. The extraction efficiencies were between 29% for DMP and 80% for di-n-propyl isocinchomeronate (R-326). The feasibility of the method was tested by analysing real samples such as lake water, river water and wastewater.  相似文献   

18.
Desai A  Shi X  Baker JR 《Electrophoresis》2008,29(2):510-515
Various generations (G1-G8) of negatively charged poly(amidoamine) (PAMAM) succinamic acid dendrimers (PAMAM-SAH) were analyzed by CE using a poly(vinyl alcohol)-coated capillary. Due to its excellent stability and osmotic flow-shielding effect, highly reproducible migration times were achieved for all generations of dendrimer (e.g., RSD for the migration times of G5 dendrimer was 0.6%). We also observed a reverse trend in migration times for the PAMAM-SAH dendrimers (i.e., higher generations migrated faster than lower generation dendrimers) compared to amine-terminated PAMAM dendrimers reported in the literature. This reversal in migration times was attributed to the difference in counterion binding around these negatively charged dendrimers. This reverse trend allowed a generational separation for lower generation (G1-G3) dendrimers. However, a sufficient resolution for the migration peaks of higher generations (G4-G5) in a mixture could not be achieved. This could be due to their nearly identical charge/mass ratio and dense molecular conformations. In addition, we show that dye-functionalized PAMAM-SAH dendrimers can also be analyzed with high reproducibility using this method.  相似文献   

19.
A simple and environmentally friendly methodology for headspace solid-phase microextraction (HS-SPME) using a new fiber coated with polydimethylsiloxane-poly(vinyl alcohol) (PDMS/PVA) is reported for the trace determination of organochlorine (OCP) and organophosphorus (OPP) pesticides in herbal infusions of Passiflora L. by GC-ECD. The capacity of the PDMS/PVA coating for the pesticides was compared to that of commercial PDMS fibers, with advantageous results. The effects of parameters such as the sample ionic strength, dilution of the infusion, extraction temperature and time were investigated. The optimized conditions for the determination of OCP and OPP in Passiflora L. infusions were extraction time and temperature, respectively, of 38 min and 67.5 degrees C, with 5 min of sample/headspace equilibration time. The analytical curves for the range between 0.04 ng mL(-1) to 6 ng mL(-1) of each compound presented a good quality (correlation coefficients of 0.921 or better). The detection limits for the OCP and OPP in these matrices varied from 0.01 ng mL(-1) (beta-endosulfan) to 1.5 ng mL(-1) (malathion). The sensitivity of studied methodology was adequate, as well as its accuracy (78.7-91.5%) and precision (R.S.D. = 1.2-14.2%).  相似文献   

20.
Traditional micro-scale simultaneous distillation-extraction (SDE) and stir bar sorptive extraction (SBSE) were compared for their effectiveness in the extraction of volatile organic compounds in a synthetic grape juice and a real grape juice (Huxelrebe, a variety of half Muscat ancestry) from an English vineyard. The novel immersion-mode SBSE method, using stir bars with PDMS sorbent, was optimised using the synthetic grape juice. Although mean percent relative recoveries and reproducibilities (%CV) of the SBSE method were inferior to SDE (28.4 and 8.5%, respectively, against 86.9 and 6.3%), the former method proved to be significantly more sensitive: 126 aroma compounds in Huxelrebe grape juice were identified using SBSE, against 98 using SDE. This allowed the identification of a number of volatile components that have not been reported previously in the juice or wine from the grapes of Muscat varieties.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号