首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Unbonded silicon oxynitride and silica high‐performance liquid chromatography stationary phases have been evaluated and compared for the separation of basic compounds of differing molecular weight, pKa, and log D using aqueous/organic mobile phases. The influences of percentage of organic modifier, buffer pH, and concentration in the mobile phase on base retention were investigated on unbonded silicon oxynitride and silica phases. The results confirmed that unbonded silicon oxynitride and silica phases demonstrated excellent separation performance for model basic compounds and both the unbonded phases examined possessed a hydrophobic/adsorption and ion‐exchange character. The silicon oxynitride stationary phase exhibited high hydrophilicity compared with silica with a reversed‐phase mobile phase. An ion‐exclusion‐type mechanism becomes predominant for the separation of three aimed bases on the silicon oxynitride column at pH 2.8. Different from silicon oxynitride stationary phase, no obvious change for the retention time of three model bases on silica stationary phase at pH 2.8 can be observed.  相似文献   

2.
There are various reversed‐phase stationary phases that offer significant differences in selectivity and retention. To investigate different reversed‐phase stationary phases (aqueous stable C18, biphenyl, pentafluorophenyl propyl, and polar‐embedded alkyl) in an automated fashion, commercial software and associated hardware for mobile phase and column selection were used in conjunction with liquid chromatography and a triple quadrupole mass spectrometer detector. A model analyte mixture was prepared using a combination of standards from varying classes of analytes (including drugs, drugs of abuse, amino acids, nicotine, and nicotine‐like compounds). Chromatographic results revealed diverse variations in selectivity and peak shape. Differences in the elution order of analytes on the polar‐embedded alkyl phase for several analytes showed distinct selectivity differences compared to the aqueous C18 phase. The electron‐rich pentafluorophenyl propyl phase showed unique selectivity toward protonated amines. The biphenyl phase provided further changes in selectivity relative to C18 with a methanolic phase, but it behaved very similarly to a C18 when an acetonitrile‐based mobile phase was evaluated. This study shows the value of rapid column screening as an alternative to excessive mobile phase variation to obtain suitable chromatographic settings for analyte separation.  相似文献   

3.
A relatively new stationary phase containing a polar group embedded in a hydrophobic backbone (i.e., ACE ® C18‐amide) was evaluated for use in supercritical fluid chromatography. The amide‐based column was compared with columns packed with bare silica, C18 silica, and a terminal‐amide silica phase. The system was held at supercritical pressure and temperature with a mobile phase composition of CO2 and methanol as cosolvent. The linear solvation energy relationship model was used to evaluate the behavior of these stationary phases, relating the retention factor of selected probes to specific chromatographic interactions. A five‐component test mixture, consisting of a group of drug‐like molecules was separated isocratically. The results show that the C18‐amide stationary phase provided a combination of interactions contributing to the retention of the probe compounds. The hydrophobic interactions are favorable; however, the electron donating ability of the embedded amide group shows a large positive interaction. Under the chromatographic conditions used, the C18‐amide column was able to provide baseline resolution of all the drug‐like probe compounds in a text mixture, while the other columns tested did not.  相似文献   

4.
A novel branch-type diamide-embedded octadecyl stationary phase was prepared by facile amidation. The preparation of this new phase involves the synthesis of new bifunctional silane ligand and surface modification of spherical silica via anchoring of silane coupling agent. The obtained diamide-embedded octadecyl stationary phase demonstrated excellent hydrophobic selectivity, as well as enhanced shape and planarity selectivity in comparison to commercial polymeric and monomeric C18 phases, respectively, as revealed by the systematic investigation into its liquid chromatographic retention of isomeric polycyclic aromatic hydrocarbons. The applicability of this new stationary phase was further testified by the effective separation of isomeric compounds belong to different chemical classes, including chain isomers of alkylbenzenes, and positional isomers of substituted aromatics. An in-depth analysis of the separation mechanisms other than molecular shape recognition involved in the new stationary phase was performed using a linear solvation energy relationships model and compared with its monoamide and pure C18 counterparts correspondingly. The performance of the new stationary phase in quantitative analysis of phenols from real-world samples was also evaluated.  相似文献   

5.
The overloaded band profiles of the protonated species of propranolol and amitriptyline were recorded under acidic conditions on four classes of stationary phases including a conventional silica/organic hybrid material in reversed‐phase liquid chromatography mode (BEH‐C18), an electrostatic repulsion reversed‐phase liquid chromatography C18 column (BEH‐C18+), a poly(styrene‐divinylbenzene) monolithic column, and a hydrophilic interaction chromatography stationary phase (underivatized BEH). The same amounts of protonated bases per unit volume of stationary phase were injected in each column (16, 47, and 141 μg/cm3). The performance of the propranolol/amitriptyline purification was assessed on the basis of the asymmetry of the recorded band profiles and on the selectivity factor achieved. The results show that the separation performed under reversed‐phase liquid chromatography like conditions (with BEH‐C18, BEH‐C18+, and polymer monolith materials) provide the largest selectivity factors due to the difference in the hydrophobic character of the two compounds. However, they also provide the most distorted overloaded band profiles due to a too small loading capacity. Remarkably, symmetric band profiles were observed with the hydrophilic interaction chromatography column. The larger loading capacity of the hydrophilic interaction chromatography column is due to the accumulation of the protonated bases into the diffuse water layer formed at the surface of the polar adsorbent. This work encourages purifying ionizable compounds on hydrophilic interaction chromatography columns rather than on reversed‐phase liquid chromatography columns.  相似文献   

6.
Two new kinds of alanine‐substituted calix[4]arene stationary phases of 5,11,17,23‐p‐tert‐butyl‐25,27‐bis(l ‐alanine‐methylester‐N‐carbonyl‐methoxy)‐26,28‐dihyroxycalix[4]arene‐bonded silica gel stationary phase (BABS4) and 5, 11, 17, 23‐p‐tert‐butyl‐25,26,27,28‐tetra(l ‐alanine‐methylester‐N‐carbonyl‐methoxy)‐calix[4]arene‐bonded silica gel stationary phase (TABS4) were prepared and characterized in the present study. They were compared with each other and investigated in terms of their chromatographic performance by using polycyclic aromatic hydrocarbons, disubstituted benzene isomers, and mono‐substituted benzenes as solute probes. The results indicated that both BABS4 and TABS4 exhibited multiple interactions with analytes. In addition, the commonly used Tanaka characterization protocol for the evaluation of commercially available stationary phases was applied to evaluate the properties of these two new functionalized calixarene stationary phases. The Tanaka test results were compared with Zorbax Eclipse XDB C18 and Kromasil phenyl columns, respectively. BABS4 has stronger hydrogen‐bonding capacity and ion‐exchange capacity than TABS4, and features weaker hydrophobicity and hydrophobic selectivity. Both of them behave similarly in stereoselectivity. Both BABS4 and TABS4 are weaker than C18 and phenyl stationary phases in hydrophobicity and hydrophobic selectivity.  相似文献   

7.
A silica‐based reversed‐phase stationary phase bonding with phenyl and tetrazole groups was synthesized by thiol‐epoxy ring opening reaction. The bonded groups could not only provide hydrophobic interaction, but also π–π, hydrogen bonding, electrostatic interactions, and so on. The results of characterization with elemental analysis and solid‐state 13C cross‐polarization magic‐angle‐spinning NMR spectroscopy indicated the successful preparation of phenyl/tetrazole sulfoether bonded stationary phase. Chromatographic evaluation revealed that phenyl/tetrazole sulfoether bonded stationary phase behaved well under the reversed‐phase mode. The column parameters (H, S*, A, B, and C) showed different selectivity compared with some typical commercial columns, and it was validated by the separation of estrogen, ginsenoside, alkaloid samples. Based on the different selectivity between phenyl/tetrazole sulfoether bonded stationary phase and C18 columns, phenyl/tetrazole sulfoether bonded stationary phase also showed potential to construct a 2D reversed‐phase liquid chromatography system with C18. And it was verified by the separation of corydalis tuber and curcuma zedoary extracts.  相似文献   

8.
A dicationic imidazolium ionic liquid modified silica stationary phase was prepared and evaluated by reversed‐phase/anion‐exchange mixed‐mode chromatography. Model compounds (polycyclic aromatic hydrocarbons and anilines) were separated well on the column by reversed‐phase chromatography; inorganic anions (bromate, bromide, nitrate, iodide, and thiocyanate), and organic anions (p‐aminobenzoic acid, p‐anilinesulfonic acid, sodium benzoate, pathalic acid, and salicylic acid) were also separated individually by anion‐exchange chromatography. Based on the multiple sites of the stationary phase, the column could separate 14 solutes containing the above series of analytes in one run. The dicationic imidazolium ionic liquid modified silica can interact with hydrophobic analytes by the hydrophobic C6 chain; it can enhance selectivity to aromatic compounds by imidazolium groups; and it also provided anion‐exchange and electrostatic interactions with ionic solutes. Compared with a monocationic ionic liquid functionalized stationary phase, the new stationary phase represented enhanced selectivity owing to more interaction sites.  相似文献   

9.
In this paper, the concept of reversed- or normal-phase chiral stationary phase liquid chromatography has been put forward according to the polar strength of mobile and stationary phases. The statistical model developed in HPLC has been used to investigate the separation mechanism of D- and L-enantiomer in chiral stationary phase liquid chromatography. It has been observed that the variation of capacity factor of enantiomers with mobile phase composition in both reversed-phase and normal-phase chiral stationary phase liquid chromatography can be described by the fundamental elution equation lnk' = a + blnCb + cCb. The effect of mobile phase composition on the selectivity of enantiomers D and L in normal-phase chiral stationary phase liquid chromatography can be described by the equation lnα = Δa + ΔblnCb, but in reversed-phase chiral stationary phase liquid chromatography the selectivity is almost independant of the mobile phase composition.  相似文献   

10.
We have developed a series of new C10 dipeptide stationary phases via a simple and effective synthetic method. The preparation of the new phases involves the synthesis of silanes and the surface modification of silica. Chromatographic evaluations of these columns were performed using the Engelhardt, Tanaka, and Neue test mixtures. The applicability of these new stationary phases was also evaluated using a series of diagnostic probes including acids, bases or neutral compounds and several generic applications. These new C10 dipeptide stationary phases showed excellent hydrolytic stability over a wide pH range. Like other existing amide-embedded columns, these new stationary phases exhibit higher retention for polar and hydrophilic compounds and different selectivity as compared to conventional C18 columns. These new phases are compatible with 100% aqueous mobile phases, and also provide high column efficiency and good peak shapes for both acidic and basic compounds.  相似文献   

11.
An empirical test is described for the evaluation of column selectivity in reversed-phase liquid chromatography. Using a test mixture of three polycyclic aromatic hydrocarbons (PAH), overall column selectivity toward PAH was assessed for over 20 different commercial C18 columns. Retention behavior was correlated to phase type (i.e., monomeric and polymeric surface modification chemistry) for custom synthesized phases. A classification scheme is proposed in which commercial C18 columns are grouped into three classes based on retention behavior: monomeric-like, polymeric-like, and intermediate phase selectivity toward PAH. Correlation of retention behavior of the test mixture with the separation of PAH mixtures and with more general column properties (e.g., phase thickness) is discussed.  相似文献   

12.
An investigation of the liquid chromatography of the minor capsaicinoids in a commercial capsaicinoid mixture is reported. Twelve stationary phases including C8, C18, C30, phenyl, and cation-exchange chemistries were examined in combination with isocratic aqueous methanol and aqueous acetonitrile mobile phases. A phenyl stationary phase and aqueous acetonitrile mobile phase baseline-resolved 7 of 11 capsaicinoids, and selected ion chromatograms (LC–ESI-MS) demonstrated this was the most effective reversed-phase separation. Argentation chromatography with an alkyl or phenyl column and aqueous silver nitrate–methanol mobile phase revealed the presence of the 6-ene-8-methyl and 6-ene-9-methyl homocapsaicin isomers and the absence of 7-ene-9-methyl homocapsaicin. A mixed phenyl–cation-exchange stationary phase (charged with silver ion) enabled unique and useful separations of the capsaicinoids.  相似文献   

13.
In order to increase chromatographic selectivity and to extend the analytical capability of reversed phase liquid chromatography (RP HPLC) many investigators have concentrated on the preparation of silica based column packings with chemically bonded phases (CBP). These phases have also been successfully used in sample preparation techniques, mainly in solid phase extraction (SPE). Although alkyl bonded phases (e.g., C2, C8, and C18) are the most widely used packings in RP HPLC and SPE, various specific applications require CBPs with polar functional groups (e.g., -NH2, -NO2, -CN, and/or -OH). The solution of problems with separation of complicated chiral compounds was attempted by applying stationary phases with chiral selectors (e.g., cyclodextrins, Pirkle phases, crown ethers, etc.). On the other hand, packings with pseudo-membrane or liquid crystal properties have been utilized for the separation of various substances of natural origin. Porous silica is commonly used as a support in the preparation of CBPs. Its physico-chemical characteristics, such as: type and structure of siliceous matrix, porosity, type and concentration of silanol groups, as well as surface purity, strongly influence the density and structure of chemically bonded phases. Recognition of these properties is helpful in optimizing separation processes based on RP HPLC elution and/or extraction of substances with polar character.  相似文献   

14.
A chemically bonded C60 silica phase was synthesized as a stationary phase for liquid chromatography (LC) and its retention behavior evaluated for various polycyclic aromatic hydrocarbons (PAHs) using microcolumn LC. The results indicate that the C60 bonded phase offers selectivity different from that of octadecylsilica (ODS) bonded phases in the separation of isomeric PAHs. With the C60 phase, PAH molecules having a partial structure similar to that of the C60 molecule, e.g. triphenylene and perylene, were retained longer than with ordinary ODS stationary phases. The results also show that good correlation exists between the retention data with this C60 bonded phase and with C60 itself as the stationary phase.  相似文献   

15.
A new approach for preparation of polar-modified reversed-phase liquid chromatography stationary phases was developed by using horizontal polymerization technique on silica surface, which was defined as “polar-copolymerized” approach. Based on this new approach, a representative polar-copolymerized stationary phase composed of mixed n-octadecyl and chloropropyl (C18–C3Cl) was synthesized. The resulting stationary phase named C18HCE was characterized with elemental analysis and solid phase 13C and 29Si NMR, which proved the chemistry of polar-copolymerized stationary phases. Chromatographic evaluation and application of the C18HCE were also investigated. The results of preliminary chromatographic evaluation demonstrated that the C18HCE stationary phase exhibited 100% aqueous mobile phase compatibility, low silanol activity. In addition, the application results demonstrated that the C18HCE had superior separation performance in alkaloids separation at acidic conditions compared to some commercial stationary phases.  相似文献   

16.
For determination of selected carotenoids, various types of columns for high-performance liquid chromatography (HPLC) with different properties have been used. The characteristics of the laboratory-used packing material containing monomeric alkyl-bonded phases (C18, C30) and phenyl as well as phenyl-hexyl stationary phases were studied. The retention data of the examined compounds were used to determine the hydrophobicity and silanol activity of stationary phases applied in the study. The presence of the polar and carboxyl groups in the structure of the bonded ligand strongly influences the polarity of the stationary phase. Columns were compared according to methylene selectivity using a series of benzene homologues. The measurements were done using a methanol–water mobile phase. Knowledge of the properties of the applied stationary phase provided the possibility to predict the RP HPLC retention behaviours in analysis of carotenoids including lutein, lycopene and β-carotene. The composition of the mobile phase, the addition of triethylamine and the type of stationary phase had been taken into account in designing the method of carotenoid identification. Also a monolithic column characterised by low hydrodynamic resistance, high porosity and high permeability was applied. The presented results show that the coverage density of the bonded ligands on silica gel packings and length of the linkage strongly influence the carotenoid retention behaviours. In our study, the highest retention parameters for lutein, lycopene and β-carotene were observed for C30 and C18 stationary phase. This effect corresponds with pore size of column packing greater than 100 Å and carbon content higher than 11 %.  相似文献   

17.
Three n-octadecylphosphonic acid-modified magnesia-zirconia reversed stationary phases (C18PZM) are prepared via the strong Lewis base interactions between organophosphonate and magnesia-zirconia composite. And two of them are end-capped by using trimethylchlorosilane as end-capping agent in different procedures. Stability studies at extreme high pH conditions (pH 9-12) show that both the non-endcapped and endcapped columns are quite stable at pH 12 mobile phase. The reversed-phase liquid chromatographic behavior of three C18PZM stationary phases are comparatively investigated in detail using a variety of basic compounds as probes. The retention of basic compounds on the three phases is studied over a wide range of pHs. And the possible retention mechanisms of basic compounds on the three stationary phases are discussed. The results show that the basic solutes retain by a hydrophobic and cation-exchange interaction mixed mechanism on three stationary phases when they are operated in eluents at pH values near to the pKa of the Brönsted conjugate acid form of the analyte, suggesting that inherent zirconol groups on ZM are not expected to interact with bases via cation-exchange interaction at lower pH. Nonetheless, the non-endcapped phase differs markedly from the edncapped ones in retention and selectivity of basic solutes using eluents at pH 4.1, implying a complex retention mechanism at this pH. The cation-exchange sites under such conditions are more likely due to the adsorbed Lewis base anionic buffer constituents (acetate) on accessible ZM surface sites than the chemisorbed phosphonate. Although the three phases exhibit very similar chromatographic behavior with eluents at pH 10.1, and show in general satisfactory separation of basic compounds and alkaloids studied, the performance for a specific analyte, however, differs largely from column to column.  相似文献   

18.
Liquid chromatography with mass spectrometry analysis of selected food samples using silica hydride stationary phases allowed for the identification and quantification of common mycotoxins including aflatoxin B1, B2, G1, G2, ochratoxin A, and fumosinin B1. Phenyl and C18 columns showed relatively similar selectivity based on hydrophobicity but the phenyl phase provides an additional mechanism, π–π interaction. The most hydrophobic of the analyzed compounds was more strongly retained on the C18 column and also has fewer unsaturated sites, which limited the interaction with the phenyl phase. Bean, maize, rice, and wheat samples were harvested and stored under conditions conducive to fungal development, and all samples presented toxin contamination exceeding the maximum tolerable limits.  相似文献   

19.
Monodisperse silica particles with average diameters of 1.9–2.9 μm were synthesized by a modified Stöber method, in which tetraethyl orthosilicate was continuously supplied to the reaction mixture containing KCl electrolyte, water, ethanol, and ammonia. The obtained silica particles were modified by self‐assembly with positively charged photosensitive diazoresin on the surface. After treatment with ultraviolet light, the ionic bonding between silica and diazoresin was converted into covalent bonding through a unique photochemistry reaction of diazoresin. Depending on the chemical structure of diazoresin and mobile phase composition, the diazoresin‐modified silica stationary phase showed different separation mechanisms, including reversed phase and hydrophilic interactions. Therefore, a variety of baseline separation of benzene analogues and organic acids was achieved by using the diazoresin‐modified silica particles as packing materials in ultra high performance liquid chromatography. According to the π–π interactional difference between carbon rings of fullerenes and benzene rings of diazoresin, C60 and C70 were also well separated by ultra‐high performance liquid chromatography. Because it has a small size, the ∼2.5 μm monodisperse diazoresin‐modified silica stationary phase shows ultra‐high efficiency compared with the commercial C18‐silica high‐performance liquid chromatography stationary phase with average diameters of ∼5 μm.  相似文献   

20.
An aqueous solution of phosphoric acid was used as a selective stationary liquid phase for the separation of volatile fatty acids under conditions of steam chromatography. Organic acids C2–C8 are eluted from the column as symmetric peaks, and the order of their elution is reverse to that observed commonly on other phases. Translated fromIzvestiya Akademii Nauk. Seriya Khimicheskaya, No. 3, pp. 497–499, March, 1997.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号