首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Energetic ions have been obtained irradiating a tungsten target with a Q-switched Nd:Yag laser, 1064?nm wavelength, 9?ns pulse width, 900?mJ maximum pulse energy and power density of the order of 1010?W/cm2. The laser-target interaction induces a strong metal etching with production of plasma in front of the target. The plasma contains neutrals and ions with high charge state. Time-of-flight measurements are presented for qualitative analysis of the ion production. A cylindrical electrostatic ion analyzer permits measuring of the yield of emitted ions, the charge state of detected ions and the ion energy distribution. Measurements indicate that, at a laser fluence of the order of 100?J/cm2, the charge state may reach 9+ and the ion energy reaches about 5?keV. The ion energy distribution is given as a function of the charge state. Experimental results indicate that an electrical field is developed along the normal to the plane of the target surface, which accelerates the ions up to high velocity. The ion velocity distributions follow a “shifted Maxwellian distribution”, which the author has corrected for the Coulomb interactions occurring inside the plasma.  相似文献   

2.

A gold target has been irradiated with a Q-switched Nd:Yag laser having 1064\,\hbox{nm} wavelength, 9\,\hbox{ns} pulse width, 900\,\hbox{mJ} maximum pulse energy and a maximum power density of the order of 10^{10}\,\hbox{W}/\hbox{cm}^2 . The laser-target interaction produces a strong gold etching with a production of a plasma in front of the target. The plasma contains neutrals and ions having high charge state. Time-of-flight measurements are presented for the analysis of the ion production and ion velocity. A cylindrical electrostatic deflection ion analyzer permits to measure the yield of the emitted ions, their charge state and their ion energy distribution. Measurements indicate that the ion charge state reaches 6^+ and 10^+ at a laser fluence of 100\,\rm{J/cm}^2 and 160\,\rm{J/cm}^2 , respectively. The maximum ion energy reaches about 2\,\hbox{keV} and 8\,\hbox{keV} at these low and at high laser fluence, respectively. Experimental ion energy distributions are given as a function of the ion charge state. Obtained results indicate that electrical fields, produced in the plume, along the normal to the plane of the target surface, exist in the unstable plasma. The electrical fields induce ion acceleration away from the target with a final velocity dependent on the ion charge state. The ion velocity distributions follow a "shifted Maxwellian distribution", which the authors have corrected for the Coulomb interactions occurring inside the plasma.  相似文献   

3.
High energy laser plasma-produced Cu ions have been implanted in silicon substrates placed at different distances and angles with respect to the normal to the surface of the ablated target. The implanted samples have been produced using the iodine high power Prague Asterix Laser System (PALS) using 438 nm wavelength irradiating in vacuum a Cu target. The high laser pulse energy (up to 230 J) and the short pulse duration (400 ps) produced a non-equilibrium plasma expanding mainly along the normal to the Cu target surface. Time-of-flight (TOF) technique was employed, through an electrostatic ion energy analyzer (IEA) placed along the target normal, in order to measure the ion energy, the ion charge state, the energy distribution and the charge state distribution. Ions had a Boltzmann energy distributions with an energy increasing with the charge state. At a laser fluence of the order of 6 × 106 J/cm2, the maximum ion energy was about 600 keV and the maximum charge state was about 27+.In order to investigate the implantation processes, Cu depth profiles have been performed with Rutherford backscattering spectrometry (RBS) of 1.5 MeV helium ions, Auger electron spectroscopy (AES) with 3 keV electron beam and 1 keV Ar sputtering ions in combination with scanning electron microscopy (SEM). Surface analysis results indicate that Cu ions are implanted within the first surface layers and that the ion penetration ranges are in agreement with the ion energy measured with IEA analysis.  相似文献   

4.
An intense laser radiation (1012 to 1011 W/cm−2) focused on the solid target creates a hot (≥1 keV) and dense plasma having high ionization state. The multiple charged ions with high current densities produced during laser matter interaction have potential application in accelerators as an ion source. This paper presents generation and detection of highly stripped titanium ions (Ti) in laser produced plasma. An Nd:glass laser (KAMETRON) delivering 50 J energy (λ=0.53 μm) in 2.5 ns was focused onto a titanium target to produce plasma. This plasma was allowed to drift across a space of ∼3 m through a diagnostic hole in the focusing mirror before ions are finally detected with the help of electrostatic ion analyzer. Maximum current density was detected for the charge states of +16 and +17 of Ti ions for laser intensity of ∼1011 W/cm−2.  相似文献   

5.
We developed an ion accelerator with a double accelerating gap system supplied by two power generators of different polarity. The ions were generated by laser ion source technique. The laser plasma induced by an excimer KrF laser, freely expanded before the action of accelerating fields. After the first gap action, the ions were again accelerated by a second gap. The total acceleration can imprint a maximum ion energy up to 160 keV per charge state. We analysed the extracted charge from a Cu target as a function of the accelerating voltage at laser energy of 9, 11 and 17 mJ deposited on a spot of 0.005 cm2. The peak of current density was 3.9 and 5.3 mA for the lower and medium laser energy at 60 kV. At the highest laser energy, the maximum output current was 11.7 mA with an accelerating voltage of 50 kV. The maximum ion dose was estimated to be 1012 ions/cm2. Under the condition of 60 kV accelerating voltage and 5.3 mA output current the normalized emittance of the beam measured by pepper pot method was 0.22 π mm mrad.  相似文献   

6.
The temperature of laser-generated pulsed plasmas is an important property that depends on many parameters, such as the particle species and the time elapsed from the laser interaction with the matter and the surface characteristics.

Laser-generated plasmas with low intensity (<1010 W/cm2) at INFN-LNS of Catania and with high intensity (>1014 W/cm2) in PALS laboratory in Prague have been investigated in terms of temperatures relative to ions, electrons, and neutral species. Time-of-flight (ToF) measurements have been performed with an electrostatic ion energy analyzer (IEA) and with different Faraday cups, in order to measure the ion and electron average velocities. The IEA was also used to measure the ion energy, the ion charge state, and the ion energy distribution.

The Maxwell–Boltzmann function permitted to fit the experimental data and to extrapolate the ion temperature of the plasma core.

The velocity of the neutrals was measured with a special mass quadrupole spectrometer. The Nd:Yag laser operating at low intensity produced an ion temperature core of the order of 400 eV and a neutral temperature of the order of 100 eV for many ablated materials. The ToF of electrons indicates the presence of hot electron emission with an energy of ~1 keV.  相似文献   

7.
A noticeable increase in the charge and energy of ions accelerated from a solid tungsten target irradiated by a femtosecond laser pulse with an intensity higher than 1016W/cm2 has been found when the target surface is precleaned by a nanosecond laser pulse with an energy density of 3 J/cm2. Tungsten ions with charges up to +29 and energies up to 1 MeV were detected in this case, while the charge and energy of tungsten ions from a target with an uncleaned surface do not exceed +3 and 12 keV, respectively.  相似文献   

8.
The nonequilibrium plasma generated by nanosecond laser pulse is characterized using a SiC detector connected in time-of-flight configuration to measure the radiations emitted from the plasma. Different metallic targets were irradiated by the pulsed laser at an intensity of 1010 W/cm2 and 200 mJ pulse energy. The SiC allows detecting ultraviolet radiations and soft X-rays, electrons, and ions. The obtained plasma has a temperature of the order of tens to hundreds eV depending on the atomic number of the irradiated target and ion accelerations of the order of 100 eV per charge state.  相似文献   

9.
We report the first interferometric observations of the dynamics of electron-ion cavitation of relativistically self-focused intense 4 TW, 400 fs laser pulse in a He gas jet. The electron density in a channel 1 mm long and 30 μm in diameter drops by a factor of approximately 10 from the maximum value of ∼8×1019 cm−3. A high radial velocity of the plasma expansion, ∼3.8×108 cm/s, corresponding to an ion energy of about 300 keV, is observed. The total energy of fast ions is estimated to be 6% of the laser pulse energy. The high-velocity radial plasma expulsion is explained by a charge separation due to the strong ponderomotive force. This experiment demonstrates a new possibility for direct transmission of a significant portion of the energy of a laser pulse to ions. Pis’ma Zh. éksp. Teor. Fiz. 66, No. 12, 787–792 (25 December 1997) Published in English in the original Russian journal. Edited by Steve Torstveit.  相似文献   

10.
fs pulsed lasers at an intensity of the order of 1018 W/cm2, with a contrast of 10−5, were employed to irradiate thin foils to study the target-normal-sheath-acceleration (TNSA) regime. The forward ion acceleration was investigated using 1/11 µm thickness foils composed of a metallic sheet on which a thin reduced graphene oxide film with 10 nm thickness was deposited by single or both faces. The forward-accelerated ions were detected using SiC semiconductors connected in time-of-flight configuration. The use of intense and long pre-pulse generating the low contrast does not permit to accelerate protons above 1 MeV because it produces a pre-plasma destroying the foil, and the successive main laser pulse interacts with the expanding plasma and not with the overdense solid surface. Experimental results demonstrated that the maximum proton energies of about 700 keV and of 4.2 MeV carbon ions and higher were obtained under the condition of the optimal acceleration procedure. The measurements of ion energy and charge states confirm that the acceleration per charge state is measurable from the proton energy, confirming the Coulomb–Boltzmann-shifted theoretical model. However, heavy ions cannot be accelerated due to their mass and low velocity, which does not permit them to be subjected to the fast and high developed electric field driving the light-ion acceleration. The ion acceleration can be optimized based on the laser focal positioning and on the foil thickness, composition, and structure, as it will be presented and discussed.  相似文献   

11.
Ge and Ta ion implantation of silicon and carbon substrates has been obtained at PALS Research Laboratory in Prague by using laser pulses of 400 ps duration, 438 nm wavelength, 1014?16 W/cm2 intensity. Substrates were exposed in vacuum at different distances from the target and at different angles with respect to the normal to the target surface. ‘On line’ measurements of ion energy were obtained with time-of-flight techniques by using an electrostatic deflector as ion energy analyzer. ‘Off line’ measurements of ion energy were obtained by Rutherford backscattering spectrometry (RBS) of 2.25 MeV He2+ beam at CEDAD Laboratory of Lecce University. The RBS spectra have given the depth profiles of the ion-implanted species and the implanted doses as a function of the laser intensity, angular position and target distance. A spectra deconvolution method based on the ion stopping power in the substrate matrix was applied in order to evidence the energy of the implanted ions. Measurements indicate that ions with energy ranging between 100 keV and 10 MeV and dose of the order of 1014?16/cm2 are implanted and that the process of ion implantation occurs mainly in substrates placed at little angles with respect to the normal to the target surface. Only a thin film deposition occurs for substrates placed at large angles with respect to the normal direction. Results indicate that the ion energies measured with the ‘on line’ and the ‘off line’ techniques are in good agreement.  相似文献   

12.
High-intensity sub-nanosecond-pulsed lasers irradiating thin targets in vacuum permit generation of electrons and ion acceleration and high photon yield emission in non-equilibrium plasmas. At intensities higher than 1015?W/cm2 thin foils can be irradiated in the target-normal sheath acceleration regime driving ion acceleration in the forward direction above 1?MeV per charge state. The distributions of emitted ions in terms of energy, charge state and angular emission are controlled by laser parameters, irradiation conditions, target geometry and composition. Advanced targets can be employed to increase the laser absorption in thin foils and to enhance the energy and the yield of the ion acceleration process. Semiconductor detectors, Thomson parabola spectrometer and streak camera can be employed as online plasma diagnostics to monitor the plasma parameters, shot by shot. Some applications in the field of the multiple ion implantation, hadrontherapy and nuclear physics are reported.  相似文献   

13.
It is found that the mean charge of tungsten ions in a solid tungsten target cleaned from the surface layer of hydrocarbon and oxide compounds and exposed to femtosecond laser radiation with an intensity exceeding 1016 W/cm2 attains 22+, while the maximum charge is 29+. The maximum energy of such ions approaches 1 MeV. The corresponding values obtained on a dirty target with the same laser pulse parameters constitute 3+, 5+, and 150 keV. The results of numerical simulation show that such a large maximum charge of ions can be attained owing to the emergence of an electrostatic ambipolar field at the sharp boundary between the plasma and vacuum. The main mechanism of ionization of ions with maximum charges is apparently impact ionization in the presence of an external quasi-static field. In addition, direct above-threshold ionization by this field can also play a significant role. It is also shown that heavy ions in a clean target are accelerated by hot electrons. This leads to the formation of high-energy ions. The effect of recombination on the charge of the ions being detected is analyzed in detail.  相似文献   

14.
We present atomic, energy, and charge spectra of ions accelerated at the front surface of a silicon target irradiated by a high-contrast femtosecond laser pulse with an intensity of 3×1016 W/cm2, which is delayed with respect to a cleaning nanosecond laser pulse of 3-J/cm2 energy density. A tremendous increase in the number of fast silicon ions and a significant growth of their maximum charge in the case of the cleaned target from 5+ to 12+ have been observed. The main specific features of the atomic, energy, and charge spectra have been analyzed by means of one-dimensional hydrodynamic transient-ionization modeling. It is shown that fast highly charged silicon ions emerge from the hot plasma layer with a density a few times less than the solid one, and their charge distribution is not deteriorated during plasma expansion.This revised version was published online in August 2005 with a corrected cover date.  相似文献   

15.
Non-equilibrium plasma was obtained by irradiating Al foils in vacuum with a femtosecond (fs) laser at intensities of the order of 1018 W/cm2. Protons and other light ions were accelerated in the forward direction by using the target-normal-sheath acceleration regime. Time-of-flight technique was employed to measure the ions' kinetic energy using SiC detectors placed at known distances and angles. The ion acceleration was monitored under different conditions of laser focal position, laser pulse energy, and laser contrast. The target was irradiated using different thicknesses and anti-reflecting graphene films. By optimizing the laser parameters, irradiation conditions, and target properties, it was possible to accelerate up to 2.3 MeV per charge state, as will be presented and discussed.  相似文献   

16.
We investigated the ion laser-produced plasma plume generated during ultrafast laser ablation of copper and silicon targets in high vacuum. The ablation plasma was induced by ≈50 fs, 800 nm Ti:Sa laser pulses irradiating the target surface at an angle of 45°. An ion probe was used to investigate the time-of-flight profiles of the emitted ions in a laser fluence range from the ablation threshold up to ≈10 J/cm2. The angular distribution of the ion flux and average velocity of the produced ions were studied by moving the ion probe on a circle around the ablation spot. The angular distribution of the ion flux is well described by an adiabatic and isentropic model of expansion of a plume produced by laser ablation of solid targets. The angular distribution of the ion flux narrows as the laser pulse fluence increases. Moreover, the ion average velocity reaches values of several tens of km/s, evidencing the presence of ions with kinetic energy of several hundred eV. Finally, the ion flux energy is confined in a narrow angular region around the target normal.  相似文献   

17.
Using a 60 nsec, 300 MW CO2 TEA laser reflection measurements from solid deuterium targets have been investigated. Energy, reflected and scattered pulse shape are recorded at various angles: 0°, 45°, 90°, 135°. Reflection, X-ray measurements and ion mean kinetic energy are correlated at the focussing lens position with respect to the target position. The maximum plasma temperature varies from 20 to 35 eV for incident laser fluxes ranging from 5 × 1010 up to 5 × 1011 W/cm2. The cut-off density inside the deuterium ice has been observed and located. In each case reflection has been found to be weak less than 5% for each direction. For the maximum fluxes X-ray energies greater than 0.5 keV have been observed.  相似文献   

18.
Electrons with abnormally high energies of up to 16 keV are detected from an iron target irradiated by ions (H+, Fe+, Fe2+, Fe3+) with energies ranging from 20 to 100 keV from the plasma of a high-power femtosecond laser pulse with an intensity of 1016 J/(s cm2). These electrons indicate that the energy of an incident ion is almost completely transferred to an electron knocked out of the target. In a range of 6–16 keV, the spectrum of electrons knocked out of the K shell of iron atoms by protons with an energy of 22 ± 2 keV is quasi-exponential with an exponent of 4 keV. For 8-keV electrons, the double differential cross section for ionization by such protons is estimated as 10?7 b/(eV sr).  相似文献   

19.
The characteristics of X rays of a laser plasma generated in the interaction of a femtosecond pulse with solid targets in an air atmosphere have been investigated. It has been shown that the mechanism for the generation of X rays in the interaction of short intense laser pulses with solid targets in a gas atmosphere is attributed to the generation of fast electrons in the region of the filamentation of a laser pulse. It has been proven experimentally that under such conditions, the solid target irradiated by laser radiation of even a low density of about 1015 W/cm2 very efficiently emits ∼10-keV photons. It has been shown theoretically that the maximum energy of accelerated electrons can reach ɛmax ∼ 100–200 keV under these conditions. This means that the proposed method can provide characteristic radiation with the energy of photons much higher than 10 keV.  相似文献   

20.
A Nd:YAG laser with 109 W/cm 2 pulse intensity, operating at 532 nm wavelength, is used to ablate Ta and Cu targets placed in vacuum. The ablation process generates a plasma in front of the target surface, which expands along the normal to target surface. The ion and electron emissions from the plasma were measured by Faraday cups placed at different angles with respect to the normal to target surface. In the range of laser intensities from 107 to 109 W/cm2, the fast electron yield is lower than the ion yield and it increases at higher laser intensities. The ablation threshold, the emission yield, the ion and electron average energies and the plasma ion and electron temperatures were measured for ion and fast electron streams.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号