首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple and reliable electrochemical method for the determination of bismuth in water and nickel metal samples using a sodium montmorillonite (SWy-2) modified carbon paste electrode was described. Due to its strong cation-exchange ability and adsorptive characteristics, SWy-2 significantly enhances the sensitivity of determination for Bi3+. Bi3+ is firstly preconcentrated and then reduced on the modified electrode surface at –0.50V. After that, reduced bismuth is stripped from the electrode surface during the positive potential sweep of –0.50V to 0.20V, and a well-defined stripping peak at –0.12V appears. The stripping peak current is proportional to the concentration of Bi3+ from 4×10–9molL–1 to 1×10–6molL–1. The detection limit (signal-to-noise=3) is 1×10–10molL–1 after 5min. accumulation. The proposed method was successfully applied to the determination of bismuth in water and nickel metal samples.  相似文献   

2.
A new method for the simultaneous determination of heavy metal ions in Chinese herbal medicine by microwave digestion and reversed-phase high-performance liquid chromatography (RP-HPLC) has been developed. The Chinese herbal medicine samples were digested by microwave digestion. Lead, cadmium, mercury, nickel, copper, zinc, and tin ions in the digested samples were pre-column derivatized with tetra-(4-chlorophenyl)-porphyrin (T4-CPP) to form the colored chelates which were then enriched by solid phase extraction with C18 cartridge and eluted from the cartridge with tetrahydrofuran (THF). The chelates were separated on a Waters Xterra RP18 column by gradient elution with methanol (containing 0.05molL–1 pyrrolidine-acetic acid buffer salt, pH=10.0) and THF (containing 0.05molL–1 pyrrolidine-acetic acid buffer salt, pH=10.0) as mobile phase at a flow rate of 0.5mLmin–1 and detected with a photodiode array detector in the range of 350–600nm. In the original samples the detection limits of lead, cadmium, mercury, nickel, copper, zinc and tin are 4ngL–1, 3ngL–1, 6ngL–1, 5ngL–1, 2ngL–1, 6ngL–1, and 4ngL–1, respectively. This method was applied to the determination of lead, cadmium, mercury, nickel, copper, zinc and tin in Chinese herbal medicine samples with good results.  相似文献   

3.
A new method of SS-RTP for the determination of trace silver has been established. This method is based on the fact that Ag+, when activated by ,-bipyridyl (bipy) in a media of HAc–NaAc (pH=4.9), can catalyze the reaction of Rhodamine B (RhoB) oxidized by K2S2O8, thus causing the Solid Substrate Room-Temperature Phosphorescence (SS-RTP) of RhoB to be quenched. The activating efficiency of bipy is 6.7 times higher than that of o-phenanthroline (phen). The reduction of the phosphorescence intensity (Ip) of RhoB is directly proportional to the concentration of Ag+ ions in the range of 1.6016.0agspot–1 (0.40µLspot–1). The regression equation of the working curve can be expressed as Ip=18.78+5.100mAg+ (agspot–1) (r=0.9994, n=6), the detection limit is 0.28agspot–1. This rapid, accurate and sensitive method has been successfully applied to the determination of trace silver in tea and human hair samples, and the results agree well with the Atomic Absorption Spectroscopy (AAS) method. The mechanism of the catalyzing reaction is also discussed.  相似文献   

4.
This paper presents a new simple and rapid procedure for the preconcentration and determination of platinum. It is based on the adsorption of the metal ion and preconcentration on a micro-column (3cm×3mm) placed in the injection valve of a flow injection (FI) manifold and packed with 1,5-bis[(2-pyridyl)-3-sulphophenyl-methylene]thiocarbonohydrazide (PSTH) immobilised on an anion-exchange resin (Dowex 1X8-200). The metal was eluted from the column using a solution of 2M HNO3. Various parameters and chemical variables affecting the preconcentration and determination of this metal by ICP-AES were evaluated. Five variables (sample flow rate, eluent flow rate, nebulizer flow rate, buffer concentration and mixing coil length) were considered as factors in the optimisation process. Interactions between analytical factors, and their optimal levels were investigated using two level factorial and central matrix designs. The optimum conditions established were applied to the determination of platinum by flow injection inductively coupled plasma atomic emission spectrometry (FI-ICP-AES). The method has a linear calibration range of 25 to at least 200ngmL–1 with a detection limit of 7.4ngmL–1 (S/N=3) and a throughput of 10 samples h–1 using 5min. preconcentration time. The precision of the method (RSD) was 3.06% ngmL–1 at the 50ngmL–1 level of Pt(IV) and 2.93% at the 150ngmL–1 level. The accuracy of the method was examined by determining the analyte content in spiked waters and by analysing an automobile catalyst standard reference material. The results show good agreement with the certified value and sufficiently high recoveries.  相似文献   

5.
A new approach, based on non-aqueous capillary electrophoresis separation and indirect photometric detection, was established for the determination of the transition metal ions Pb2+, Zn2+ and Cd2+. Under optimized conditions, the method produced baseline separation of these three metal ions. The linear range and detection limits were 1050µM, 1.9µM for Cd2+; 1050µM, 2.1µM for Zn2+; and 20100µM, 3.8µM for Pb2+, respectively.  相似文献   

6.
Summary. Zr5Ir2In4 was synthesized by reaction of the elements in a glassy carbon crucible in a water-cooled sample chamber of an induction furnace. The sample was characterized by X-ray diffraction on both powder and single crystals. Zr5Ir2In4 crystallizes with a pronounced Lu5Ni2In4 type subcell, space group Pbam, a=1739.5(6), b=766.3(2), c=338.9(2) pm. Weak additional reflections force a doubling of the subcell c axis. The superstructure of Zr5Ir2In4 is of a new type: Pnma, a=1739.5(6), b=677.8(2), c=766.3(2) pm, wR2=0.0529, 1592 F2 values, and 60 variable parameters. The group-subgroup scheme for the klassengleiche symmetry reduction is presented. The formation of the superstructure is most likely due to a puckering effect (size of the iridium atoms). The crystal chemistry of Zr5Ir2In4 is briefly discussed.  相似文献   

7.
The interaction of indophenol blue (IPB) with proteins in aqueous solution has been studied by optical absorption and Rayleigh light scattering (RLS) spectroscopy. At pH 3.8, the weak RLS of IPB is enhanced by proteins. Based on this phenomenon, a novel method for the determination of proteins at nanogram levels using the RLS technique is developed. The method is simple, practical and sensitive. The linear range is 0.25–20.9µgmL–1 for BSA, and 0.25–17.6µgmL–1 for HSA. The detection limits (S/N=3) are 23ngmL–1 for BSA and 22ngmL–1 for HAS. The results for the determination of proteins in human serum samples are very close to those obtained by an established clinical method. There is very little interference from amino acids, metal ions or other coexisting compounds.  相似文献   

8.
Nanometer-sized L-cysteine-capped ZnS particles were synthesized by a colloidal aqueous method. The functionalized nanoparticles are water-soluble and suitable for biological applications. In Tris-HCl buffer solution, nucleic acids combine with cysteine-capped nano-ZnS particles by intermolecular forces to form larger nanoparticles. There are two resonance light scattering peaks at 304.5nm and 373.8nm, respectively. The enhanced RLS is related to the concentration of nucleic acids in the range of 0.04 to 1.2µgmL–1 for calf thymus DNA and 0.2 to 1.0µgmL–1 for fish sperm DNA. The detection limits (3) are 19ngmL–1 for calf thymus DNA and 23ngmL–1 for fish sperm DNA, respectively. Four synthetic samples were analyzed satisfactorily.  相似文献   

9.
This study describes the sample preparation and two chromatographic techniques for determination of Tinuvin 622 in polyethylene. The first part of the two methods consisting of dissolving the polyethylene in boiling xylene is followed by addition of a methanolic solution of potassium hydroxide. The polymeric light stabilizer, Tinuvin 622, is thereby saponified to 4-hydroxy-2,2,6,6-tetramethyl-1-piperidineethanol (diol). Addition of the methanolic solution of the saponification reagent simultaneously precipitates the polyethylene matrix. Then the diol is quantified using either gas chromatography (GC) or high performance liquid chromatography (HPLC). For GC, a Macherey Nagel Optima-17 capillary column (30m×0.25mm ID, film thickness 0.25µm) is used. Nitrogen is used as carrier gas and make-up gas. The detection system is a flame ionization detector. For HPLC, an octadecyl silane (ODS) column (30cm×4mm, particle size 5µm) and a mobile phase methanol: water mixture (3:97, v/v) are used. Detection of analyte is carried out at 215nm. Both methods can be used to determine Tinuvin 622 in polyethylene in the concentration range of 0.02–1%, which represents the usual application concentration.  相似文献   

10.
A simple and novel electrogenerated chemiluminescence (ECL) method for the determination of sulfite has been developed based on the energy transfer ECL process. It was found that a weak ECL signal of sulfite was electrochemically generated on a platinum electrode in neutral aqueous solution. The signal was strongly enhanced by rhodamine B as an energy receptor and further enhanced by the neutral surfactant Tween 80. In 0.10M phosphate buffer solution (pH=7.5) containing 2.0×10–6gmL–1 rhodamine B and 0.4% (v/v) Tween 80, the ECL response to the concentration of sulfite at a potential of 0.82V was linear over a range of 1.0×10–7gmL–1 to 8.0×10–6gmL–1, and the detection limit was 5×10–8gmL–1. The relative standard deviation (n=11, 1.0×10–6gmL–1) was 3.8%. The proposed method has been successfully applied to the determination of sulfite in pharmaceutical injections and white sugar samples.  相似文献   

11.
Two different methods (one based on chromatography and spectrophotometry and the other on polarography) have been developed for the determination of glyoxylic acid in the form of a derivative with 2,4-dinitrophenylhydrazine (DNPHGA). The TLC method allows the separation of two DNPHGA isomers (trans and cis). Spectrophotometric measurements of the eluents of the separated compounds (=360 nm) allow the determination of GA within the range from 4 to 30 g. Using differential pulse polarography, the conditions of DNPHGA formation were examined. The reduction peak of this derivative (EP=–0.430 V), observed by dpp, was used to develop a polarographic determination of GA within the concentration range from 110-4 to 710–4 mol/l.  相似文献   

12.
Summary. Steady state quenching studies of curcumin, 1,7-bis(4-hydroxy-3-methoxyphenyl)-1,6-heptadiene-3,5-dione, fluorescence by hydrogen peroxide were conducted in acetonitrile solution. A quenching rate constant, kq, of 1.05×1010M–1·s–1 was obtained with a short fluorescence lifetime of 347ps. The reaction rate constant, which is within the diffusion-limited regime, is activation-controlled. The rate constant of deactivation of the thermally excited curcumin was 1.2 orders of magnitude more nonradiative (2.67×109s–1) than radiative (2.16×108s–1). The reaction was exothermic with a G° of –1.97eV and solvent reorganization energy of 1.37eV. These values indicate that the electron transfer reaction is solvent-mediated with electron transfer rate constant, kET, of 2.16×1010s–1.  相似文献   

13.
A comparative study of commercial C18 chemically immobilized on silica and homemade C18, as sorbents for Pb complexed with O,O-diethyl-dithiophosphate (DDTP) in a flow injection preconcentration system is reported. The homemade C18 sorbent was obtained by sorption of poly(methyloctadecylsiloxane) (PMODS) on the silica support followed by immobilization using thermal treatment. The method follows the concept of green chemistry, since there are no toxic residues after synthesis. The complexed Pb was formed in 1.0molL–1 HCl medium and retained on the minicolumn filled with the sorbents. The elution was carried out using ethanol, and the richest 210µL fraction was collected and analyzed by flame atomic absorption spectrometry. Chemical and flow variables were optimized for each sorbent. The results demonstrated that the performance of the proposed homemade C18 sorbent for preconcentration of Pb complexed with DDTP is very similar to commercial C18 chemically bonded on silica. By processing 25mL, the enrichment factors were 129 and 125 for commercial C18 and homemade C18, respectively. The limit of detection for commercial and homemade C18 was 0.2µgL–1 and 0.6µgL–1, respectively. The relative standard deviation (RSD) was lower than 1.2% for both sorbents for a Pb concentration of 100µgL–1. The method was also applied successfully to the analysis of water samples, and the accuracy was tested by recovery measurements on spiked samples and biological reference material.  相似文献   

14.
Although neverdried cotton (NDC) fiber has been known to exhibit extremely high water absorbency, the reason for this has not yet been elucidated. In this study, changes in water absorbency, bound water content as revealed by differential scanning calorimetry (DSC), cellulose content and fiber crosssection observed by scanning electron microscopy (SEM) for NDC fibers at several stages of development (27–57 days postanthesis (DPA)) were investigated. It was found that the bound water content (27g/l00g) of NDC fibers at 50DPA is much smaller than that (40–73g/l00g) for fibers at 27–43DPA. Cellulose synthesis takes place within the cotton boll, a closed watercontaining system. Our results are rationalized by assuming that these water molecules are preventing the formation of intermolecular hydrogen bonds between the cellulose molecules as they are being formed. Other explanations for our experimental findings are: (i) the coexistence of precursors of cellulose and components, such as (1,3);glucans, that are very hydrophilic, and (ii) the presence in each NDC fiber of a prominent lumen that acts as a capillary system for water.  相似文献   

15.
The kinetics of formation and dissociation reactions of [Ru(CN)5L]3– with a series of heterocyclic ligands were studied in aqueous media. In this presence of an excess of heterocycle, the observed second order rate constants were calculated from the kobs versus [ligand] plot at =0.100m NaClO4. Activation parameters for the formation reactions (H=28±7kJmol–1 and S=140±35JK–1mol–1) are comparable for all systems, indicating a common mechanism. The kinetics of exchange of coordinated heterocycles for 1,3,5-triazine yielded a rate saturation typical of a limiting dissociative mechanism. Activation parameters of the limiting first order specific rate of dissociation reactions were H=85±7kJmol–1 and S=18±4JK–1mol–1. Equilibrium constants were calculated from the second order rates of formation and pseudo-first order rates of dissociation reaction.  相似文献   

16.
Thallium in natural water samples was determined by electrothermal atomic absorption spectrometry after 1000-fold enrichment by mini solid-phase extraction from a 100-mL sample solution. A Tl-pyrrolidine-1-carbodithioate complex formed in a sample solution of pH 1.6 was extracted on fine particles of a cellulose nitrate resin dispersed in the sample solution. The cellulose nitrate resin was then collected on a membrane filter (25mmø) by filtration under suction using a glass funnel with an effective filtration area of 0.64cm2. As a result, a circular thin layer of the resin phase with a diameter of 9mm was obtained. Then the resin phase was carved out by an acrylate resin puncher with a 10-mmø hole to put it into a sample cup containing 100µL of 10mM HNO3 containing 0.5mM NaCl. The resin phase was suspended in the solution by ultrasonication. 1000-fold enrichment was thus attained within 15min, and the suspension was delivered to electrothermal atomic absorption spectrometry. The linear calibration graph was obtained in the range of 0–4ng of Tl in 100mL of a sample solution. The detection limit obtained by 3 method was 0.19ng. The proposed method was applied to the determination of Tl in natural water samples. The results showed the concentration of Tl in seawater was 12.1±1.8pgmL–1 for the calibration graph method and 12.6±1.4pgmL–1 for the standard addition method. A snowmelt sample contained 20.7±1.0pgmL–1 of Tl.  相似文献   

17.
A new, simple, reliable and self-consistent procedure has been developed to produce, handle and measure radon in 10mL of air in the three media air, water and charcoal simultaneously. Equal and low activities of radon (200Bq, 4ag) are transferred with a 10mL gas syringe from a 3.8L natural, harmless and constant radon source to three receivers: a 48L Peli case with outdoor air, an 0.5L bottle with tap water, and a 22mL tube with activated charcoal. Concentrations, i.e. activities in the three media are measured with different methods providing independent results. Hence, in-laboratory cross-method calibration and traceability to a certified standard is available for radon in air and in water for the first time and with minimum effort.  相似文献   

18.
A simple commercial graphite pencil electrode (GPE) was utilized for monitoring caffeine using the square-wave anodic stripping voltammetry (SWASV) method. This method was applied to determine the caffeine levels in several tea samples, which yielded a relative error of 1% in the concentrations. Caffeine was deposited at 0.0V (vs. Ag/AgCl), then reduced at +1.40V to strip it on the GPE. Optimal experimental conditions for the analysis were found to be as follows: pH value of 9 for the medium; deposition potential of 0.0V; deposition time of 120s; SW frequency of 25Hz; SW amplitude of 45mV, and step potential of 6mV. Given these optimum conditions, a linear range was observed within the concentration of 0500mgL–1. At caffeine concentrations of 50.0, 250.0, and 500.0mgL–1, the relative standard deviations in measured concentrations (n=12) were 0.19, 0.09, and 0.11%, respectively. The detection limit was found to be 9.2mgL–1, which is comparable with the result obtained using a carbon paste electrode, equivalent to 8.2mgL–1.  相似文献   

19.
A method for the determination of trace amounts of arsenic in food samples using flow injection analysis and atomic absorption spectrometry with hydride generation (FI-HG AAS) was developed. The parameters of the flow injection system and the hydride generation were optimized with respect to reagent concentrations, atomization temperature, injection volume, reaction coil length and carrier flow rate. The limits of detection and quantification were 0.34µgL–1 and 1.2µgL–:1, respectively, and the analytical curve is linear up to 30.0µgL–1 arsenic. The relative standard deviation for 12 replicates varies between 5% for 4.0µgL–1 As and 1.8% for 30.0µgL–1 As, with an injection frequency of up to 135h–1. Interferences from Ni(II), Cu(II), Fe(III), Cr(III), Mo(II), Bi(III), Se(IV), Se(VI), Sb(III) and Sb(V) could be masked with a mixture of ascorbic acid-KI in a 5.0molL–1 HCl solution. The accuracy of the proposed method was evaluated by using certified reference materials of biological samples, and the method was used to determine the content of arsenic in fish and coffee beans.  相似文献   

20.
A novel kinetic spectrophotometry for the determination of trace aluminum is described based on the catalytic activity of Al3+ on the redox reaction between methylene blue (MB) and hydrogen peroxide in acetate buffer (pH 3.8). The reaction is monitored spectrophotometrically by measuring the decrease in absorbance of the dye at the maximum absorption wavelength of 670nm. The variables that affected the reaction rate were fully investigated, and the optimum conditions were established. Aluminum can be determined in the range of 0–80ngmL–1 with a detection limit of 1.0ngmL–1. The relative standard deviation for 10 replicate determinations of 40ngmL–1 aluminum is 0.9%. The method was used to determine aluminum in tap water and biological samples and produced satisfactory results.Received December 18, 2002; accepted May 5, 2003 published online August 22, 2003  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号