首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 851 毫秒
1.
In hollow fiber membrane liquid-phase microextraction (LPME), target analytes are extracted from aqueous samples and into a supported liquid membrane (SLM) sustained in the pores in the wall of a small porous hollow fiber, and further into an acceptor phase present inside the lumen of the hollow fiber. The acceptor phase can be organic, providing a two-phase extraction system compatible with capillary gas chromatography, or the acceptor phase can be aqueous resulting in a three-phase system compatible with high-performance liquid chromatography or capillary electrophoresis. Due to high enrichment, efficient sample clean-up, and the low consumption of organic solvent, substantial interest has been devoted to LPME in recent years. This paper reviews important applications of LPME with special focus on bioanalytical and environmental chemistry, and also covers a new possible direction for LPME namely electromembrane extraction, where analytes are extracted through the SLM and into the acceptor phase by the application of electrical potentials.  相似文献   

2.
The ultrasonic nebulization extraction coupled with headspace hollow fiber microextraction (UNE-HS-HFME) was applied for the extraction of pesticides from root of Panax ginseng C.A. Mey. Experimental parameters, which affect the performances of ultrasonic nebulization extraction coupled with headspace hollow fiber microextraction, such as the kind of acceptor solvent in the pore of the fiber wall, the sample amount, extraction time, salt concentration in extraction solvent, pH of the acceptor solution, the elution time, and times were studied and optimized. The analytes were determined by high-performance liquid chromatography. The detection limits for simeton, monolinuron, chlortoluron, karmex, and prebane are 20.9, 18.4, 18.2, 12.4, and 22.2 μg/kg, respectively. Besides volatile and semi-volatile compounds, the non-volatile compounds also can be determined by the proposed method. The extraction and enrichment process can be performed simultaneously.  相似文献   

3.
Hollow fiber liquid-phase microextraction (HF-LPME) offers an efficient alternative to classical techniques for sample preparation and preconcentration. Features include high selectivity, good enrichment factors, and improved possibilities for automation. HP-LPME relies on the extraction of target analytes from aqueous samples into a supported liquid membrane (SLM) sustained in the pores of the wall of a porous hollow fiber, and then into an acceptor phase (that can be aqueous or organic) in the lumen of the hollow fiber. After extraction, the acceptor solution is directly subjected to a chemical analysis. HP-LPME can be performed in either the 2- or 3-phases mode. In the 2-phase mode, the organic solvent is present both in the porous wall and inside the lumen of the hollow fiber. In the 3-phase mode, the acceptor phase can be aqueous and this results in a conventional 3-phase system compatible with HPLC or capillary electrophoresis. Alternatively, the acceptor solution is organic and this represents a 3-phase extraction system with two immiscible organic solvents that is compatible with all common analytical instruments. In HP-LPME methods based on the use of SLMs, the mass transfer occurs by passive diffusion, and high extraction yields as well as efficient extraction kinetics are obtained by applying a pH gradient. In addition, active transport can be performed by using carrier or applying an electrical potential across the SLM. Due to high analyte preconcentration, excellent sample clean-up, and low consumption of organic solvent, HF-LPME has a large application potential in areas such as drug analysis and environmental monitoring. This review focuses on the fundamentals of extraction principles, technical implementations, and future trends in HF-LPME.
Figure
Schematic diagram of three-phase HF-LPME based of two immiscible organic solvent  相似文献   

4.
This paper describes the development of a new design of hollow fiber solid/liquid phase microextraction (HF-SLPME) for determination of brilliant green (BG) residues in water fish ponds. This method consists of an aqueous donor phase and carbon nanotube reinforced organic solvent (acceptor phase) operated in direct immersion sampling mode. The multi-walled carbon nanotube dispersed in the organic solvent is held in the pores and lumen of a porous polypropylene hollow fiber. It is in contact directly with the aqueous donor phase. In this method the solid/liquid extractor phase is supported using a polypropylene hollow fiber membrane. Both ends of the hollow fiber segment are sealed with magnetic stoppers. This device is placed inside the donor solution and plays the rule of a pseudo-stir bar. It is disposable, so single use of the fiber reduces the risk of carry-over problems. Brilliant green (BG) after extraction from the aqueous samples with mentioned HF-SLPME device was determined by ultraviolet-visible spectroscopy with diode array detection (UV-vis/DAD). The absorption wavelength was set to 625 nm (λ(max)). The effect of different variables on the extraction was evaluated and optimized to enhance the sensitivity and extraction efficiency of the proposed method. The calibration curve was linear in the range of 1.00-10,000 μg L(-1) of BG in the initial solution with R(2)=0.979. Detection limit, based on three times the standard deviation of the blank, was 0.55 μg L(-1). All experiments were carried out at room temperature (25±0.5°C).  相似文献   

5.
The 1-octyl-3-methylimidazolium hexafluorophosphate ([C8MIM][PF6]) ionic liquid was immobilized in the pores of a polypropylene hollow fiber for hollow fiber-protected liquid-phase microextraction. Analytes including 4-chlorophenol (4-CP), 3-chorophenol (3-CP), 2,4-dichlorophenol (2,4-DCP) and 2,4,6-trichlorophenol (2,4,6-TCP) were extracted into this ionic liquid membrane, and back extracted into 10microL sodium hydroxide acceptor solution in the lumen of the hollow fiber. Then, the acceptor solution was withdrawn into the high-performance liquid chromatography (HPLC) microsyringe connected to the hollow fiber, and directly injected into the HPLC system for analysis. Some parameters that might affect the extraction efficiency were optimized, and low detection limits (0.5microgL(-1) for 4-CP, 3-CP, DCP and 1.0microgL(-1) for TCP) were obtained. Good repeatability was achieved because of the stability of the hollow fiber-supported ionic liquid membrane. The proposed procedure was applied for direct determination of the four chlorophenols in some real water samples including groundwater, river water, wastewater and tap water. All of the four chlorophenols in these water samples were under the limits of determination, and the recoveries were in the range of 70.0-95.7% at 5microgL(-1) spiked level.  相似文献   

6.
Electro membrane extraction as a new microextraction method was applied for the extraction of amlodipine (AM) enantiomers from biological samples. During the extraction time of 15 min, AM enantiomers migrated from a 3 mL sample solution, through a supported liquid membrane into a 20 μL acceptor solution presented inside the lumen of the hollow fiber. The driving force of the extraction was 200 V potential, with the negative electrode in the acceptor solution and the positive electrode in the sample solution. 2-Nitro phenyl octylether was used as the supported liquid membrane. Using 10 mM HCl as background electrolyte in the sample and acceptor solution, enrichment up to 124 times was achieved. Then, the extract was analyzed using CD modified CE method for separation of AM enantiomers. Best results were achieved using a phosphate running buffer (100 mM, pH 2.0) containing 5 mM hydroxypropyl-α-CD. The range of quantitation for both enantiomers was 10-500 ng/mL. Intra- and interday RSD (n=6) were less than 14%. The limits of quantitation and detection for both enantiomers were 10 and 3 ng/mL respectively. Finally, this procedure was applied to determine the concentration of AM enantiomers in plasma and urine samples.  相似文献   

7.
液膜萃取技术在环境样品前处理中的应用   总被引:1,自引:4,他引:1  
膜分离技术是利用膜对混合物中各组分的选择渗透性能的差异来实现分离、提纯和浓缩的新型分离技术。近年来,随着人们环保意识的加强,环境中污染物的监测逐渐被重视。因环境样品基体的复杂性,在分析测定前必须进行净化处理。将膜分离技术与液液萃取技术相结合的液膜萃取技术因其  相似文献   

8.
A new organic solvent-free microextraction technique termed liquid-gas-liquid microextraction (LGLME) was developed. In this technique, a small amount (6 microl) of aqueous acceptor solution (0.5M NaOH) is introduced into the channel of a 2.65 cm polypropylene hollow fiber. The hollow fiber is then immersed in an aqueous sample donor solution. The aqueous acceptor phase in the channel of the hollow fiber is separated from the sample solution by the hydrophobic microporous hollow fiber wall with air inside its pores. The analytes (phenols) passed through the microporous hollow fiber membrane by gas diffusion and were then trapped by the basic acceptor solution. After extraction, the acceptor solution was withdrawn into a microsyringe and injected into a capillary electrophoresis sample vial for subsequent analysis. Limits of detection of between 0.5 and 10 microg/l for eight phenols could be achieved. The relative standard deviations (n=6) of this technique between 2.7 and 7.6%. The technique also provides good enrichment factors for all the eight analytes.  相似文献   

9.
A simple liquid-liquid-liquid microextraction device utilizing a 2 cm x 0.6 mm I.D. hollow fiber membrane was used to preconcentrate nitrophenols from water sample prior to capillary liquid chromatography (cLC) analysis. The extraction procedure was induced by the pH difference inside and outside the hollow fiber. The donor phase outside the hollow fiber was adjusted to pH approximately 1 with HCl; the acceptor phase was NaOH solution used at various concentrations. Organic solvent was immobilized into the pores of the hollow fiber. With stirring, the neutral nitrophenols outside the fiber were extracted into the organic solvent, then back extracted into 2 microl of basic acceptor solution inside the fiber. The acceptor phase was then withdrawn into a microsyringe and injected into the cLC system directly. This technique used a low-cost disposable extraction "device" and is very convenient to operate. Up to 380-fold enrichment of analytes could be achieved. This procedure could also serve as a sample clean-up step because large molecules and basic compounds were not extracted into the acceptor phase. The RSD (n=6) was less than 6.2%, while the linear calibration range was from 1 to 200 microg/ml with r>0.998. The procedure was applied to the analysis of seawater.  相似文献   

10.
An automated dynamic two-phase hollow fiber microextraction apparatus combined with high-performance liquid chromatography was developed for extraction and determination of chlorophenoxy acid (CPA) herbicides from environmental samples. The extraction device, called TT-extractor, consists of a polypropylene hollow fiber mounted inside a stainless steel tube by means of two tee-connectors in flow system. An organic solvent, which fills the lumen and the pores of the hydrophobic fiber, is pumped through the fiber repeatedly and the sample is pumped along the outer side of the fiber. The factors affecting the dynamic hollow fiber liquid-phase microextraction (DHF-LPME) of target analytes were investigated and the optimal extraction conditions were established. To test the applicability of the designed instrument, CPAs were extracted from environmental aqueous samples. The limits of detection (LODs) as low as 0.5 μg/L, linear dynamic range in the range of 1-100 μg/L and the relative standard deviations of <7% were obtained. The developed method can provide perconcentration factors as large as 230. A hollow fiber membrane can be used at least 20 times with neither loss in the efficiency nor carryover of the analytes between runs. The system is cheap and convenient and requires minimal manual handling.  相似文献   

11.
Two different modes of three‐phase hollow fiber liquid‐phase microextraction were studied for the extraction of two herbicides, bensulfuron‐methyl and linuron. In these two modes, the acceptor phases in the lumen of the hollow fiber were aqueous and organic solvents. The extraction and determination were performed using an automated hollow fiber microextraction instrument followed by high‐performance liquid chromatography. For both three‐phase hollow fiber liquid‐phase microextraction modes, the effect of the main parameters on the extraction efficiency were investigated and optimized by central composite design. Under optimal conditions, both modes showed good linearity and repeatability, but the three‐phase hollow fiber liquid‐phase microextraction based on two immiscible organic solvents has a better extraction efficiency and figures of merit. The calibration curves for three‐phase hollow fiber liquid‐phase microextraction with an organic acceptor phase were linear in the range of 0.3–200 and 0.1–150 μg/L and the limits of detection were 0.1 and 0.06 μg/L for bensulfuron‐methyl and linuron, respectively. For the conventional three‐phase hollow fiber liquid‐phase microextraction, the calibration curves were linear in the range of 3.0–250 and 15–400 μg/L and LODs were 1.0 and 5.0 μg/L for bensulfuron‐methyl and linuron, respectively. The real sample analysis was carried out by three‐phase hollow fiber liquid phase microextraction based on two immiscible organic solvents because of its more favorable characteristics.  相似文献   

12.
A new design of hollow fiber solid–liquid phase microextraction (HF-SLPME) was developed for the determination of caffeic acid in medicinal plants samples as Echinacea purpure. The membrane extraction with sorbent interface used in this research is a three-phase supported liquid membrane consisting of an aqueous (donor phase), organic solvent/nano sorbent (membrane) and aqueous (acceptor phase) system operated in direct immersion sampling mode. The multi-walled carbon nanotube dispersed in the organic solvent is held in the pores of a porous membrane supported by capillary forces and sonification. It is in contact with two aqueous phases: the donor phase, which is the aqueous sample, and the acceptor phase, usually an aqueous buffer. All microextraction experiments were supported using an Accurel Q3/2 polypropylene hollow fiber membrane (600 μm I.D., 200 μm wall thicknesses, and 0.2 μm pore size). The experimental setup is very simple and highly affordable. The hollow fiber is disposable, so single use of the fiber reduces the risk of cross-contamination and carry-over problems. The proposed method allows the very effective and enriched recuperation of an acidic analyte into one single extract. In order to obtain high enrichment and extraction efficiency of the analyte using this novel technique, the main parameters were optimized. Under the optimized extraction conditions, the method showed good linearity (0.0001–50 μg/L), repeatability, low limits of detection (0.00005 μg/L) and excellent enrichment (EF = 2108).  相似文献   

13.
In this work, the simple analytical method for the determination of four fluoroquinolone antibiotics: ciprofloxacin, enrofloxacin, norfloxacin and danofloxacin, in environmental surface water samples is described. Sample pretreatment step was performed by the application of a technique based on supported liquid membrane extraction with the configuration of single hollow fiber (HF-SLM). The HPLC system with diode array detection was used for final analysis of studied analytes. Various parameters affecting the extraction efficiency during HF-SLM enrichment, such as type of membrane diluent, pH of donor (sample) and acceptor phases, as well as an enrichment time and salt content of sample were studied. Using the presented hollow-fiber extraction high recovery (70–80%) was achieved. It gave enrichment factor above 100. The detection limits in surface water samples, for the four target antibiotics, were at range 0.01–0.02 μg/l, when 10 ml samples were processed. The obtained results demonstrate the applicability of presented method for the selective extraction of fluoroquinolones in environmental water samples at ultratrace level. Errors, expressed as relative standard deviation (RSD) were below 8%, for all tested concentration levels.  相似文献   

14.
Abstract

The field of application of a mobile gas chromatographic device (Airmobtx monitor HC 1000 manufactured by Airmotec GmbH) originally conceived for the analysis of BTEX in air was extended to water analysis by using it in conjunction with membrane extraction. Volatile organic compounds diffuse out of water through a hollow fibre or flat membrane, are enriched onto sorption tubes integrated in the device, and then thermally desorbed and analysed by the gas chromatograph/flame ionisation detector. The suitability of various flat membranes and hollow fibres was investigated. Maximum extraction efficiency was obtained with a silicone hollow fibre measuring 0.3 m long, and with an inner diameter of 0.7 mm and a wall thickness of 100 μm. The extraction parameters were optimised. The linear dynamic range of the optimised method spans two orders of magnitude and the detection limits were found to be 0.1 μg/L for all BTEX compounds. By way of environmental applications, highly contaminated groundwater samples were analysed. The results correspond well to those achieved using conventional headspace/gas chromatography/flame ionisation detection.  相似文献   

15.
Electromembrane extraction (EME) proved to be a simple and rapid pretreatment method for analysis of amino acids and related compounds in body fluid samples. Body fluids were acidified to the final concentration of 2.5 M acetic acid and served as donor solutions. Amino acids, present as cations in the donor solutions, migrated through a supported liquid membrane (SLM) composed of 1-ethyl-2-nitrobenzene/bis-(2-ethylhexyl)phosphonic acid (85:15 (v/v)) into the lumen of a porous polypropylene hollow fiber (HF) on application of electric field. The HF was filled with 2.5 M acetic acid serving as the acceptor solution. Matrix components in body fluids were efficiently retained on the SLM and did not interfere with subsequent analysis. Capillary electrophoresis with capacitively coupled contactless conductivity detection was used for determination of 17 underivatized amino acids in background electrolyte solution consisting of 2.5 M acetic acid. Parameters of EME, such as composition of SLM, pH and composition of donor and acceptor solution, agitation speed, extraction voltage, and extraction time were studied in detail. At optimized conditions, repeatability of migration times and peak areas of 17 amino acids was better than 0.3% and 13%, respectively, calibration curves were linear in a range of two orders of magnitude (r(2)=0.9968-0.9993) and limits of detection ranged from 0.15 to 10 μM. Endogenous concentrations of 12 amino acids were determined in EME treated human serum, plasma, and whole blood. The method was also suitable for simple and rapid pretreatment and determination of elevated concentrations of selected amino acids, which are markers of severe inborn metabolic disorders.  相似文献   

16.
A simple, inexpensive and disposable device for liquid-phase microextraction (LPME) is presented for use in combination with capillary gas chromatography (GC), capillary electrophoresis (CE) and high-performance liquid chromatography (HPLC). 1-4 ml samples of human urine or plasma were filled into conventional 4-ml vials, whereafter 15-25 microl of the extraction medium (acceptor solution) was filled into a short piece of a porous hollow fiber and placed into the sample vial. The drugs of interest were extracted from the sample solutions and into the small volumes of acceptor solution based on high partition coefficients and were preconcentrated by a factor of 30-125. For LPME in combination with GC, the porous hollow fiber was filled with 15 microl n-octanol as the acceptor solution. Following 30 min of extraction, the organic acceptor solution was injected directly into the GC system. For LPME in combination with CE and HPLC, n-octanol was immobilized within the pores of the hollow fiber, while the internal volume of the fiber was filled with either 25 microl of 0.1 M HCl (for extraction of basic compounds) or 25 microl 0.02 M NaOH (for acidic compounds). Following 45 min extraction, the aqueous acceptor solution was injected directly into the CE or HPLC system. Owing to the low cost, the extraction devices were disposed after a single extraction which eliminated the possibility of carry over effects. In addition, because no expensive instrumentation was required for LPME, 10-30 samples were extracted in parallel to provide a high number of samples per unit time capacity.  相似文献   

17.
Thirty-five different basic drugs were extracted by electro membrane extraction (EME), from acidified samples containing HCl as the BGE, through an organic solvent immobilized in the pores in the wall of a porous hollow fiber (supported liquid membrane, SLM), and into an acidified acceptor solution (HCl) in the lumen of the hollow fiber by the application of an electrical potential difference of 50 V. With 2-nitrophenyl pentyl ether (NPPE) as the SLM, and with 10 mM HCl as BGE in the sample and acceptor solution, singly charged basic drugs with log P >2 were extracted with recoveries in the range 30-81% within 5 min. For doubly charged basic drugs, extraction was effectively enhanced by decreasing the concentration of HCl in the sample from 10 to 0.1 mM, reducing the ionization of the analytes. For medium polar analytes (1 < log P < 2), an ion balance of 0.01 was combined with addition of tris-(2-ethylhexyl) phosphate (TEHP) to the SLM, and this provided recoveries in the range 36-70%. The ion balance was defined as the concentration ratio of BGE between the sample and the acceptor solution. For the most polar drugs (log P <1), EME was accomplished with an ion balance of 0.01 and with di-(2-ethylhexyl) phosphate (DEHP) added to the SLM, but in spite of this, recoveries were in the range of only 4-17%.  相似文献   

18.
Guo L  Lee HK 《Journal of chromatography. A》2011,1218(28):4299-4306
For the first time, an ionic liquid based three-phase liquid-liquid-liquid solvent bar microextraction (IL-LLL-SBME) was developed for the analysis of phenols in seawater samples. The ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate ([BMIM][PF(6)]), was used as the intermediary solvent for LLL-SBME, enhancing the extraction efficiency for polar analytes. In the procedure, the analytes were extracted from the aqueous sample into the ionic liquid intermediary and finally, back-extracted into an aqueous acceptor solution in the lumen of the hollow fiber. The porous polypropylene membrane acted as a filter to prevent potential interfering materials from being extracted, and no additional cleanup was required. After extraction, the acceptor solution could be directly injected into a high-performance liquid chromatographic system for analysis. Six phenols, 2-nitrophenol, 4-chlorophenol, 2,3-dichlorophenol, 2,4-dichlorophenol, 2,4,6-trichlorophenol and pentachlorophenol were selected here as model compounds for developing and evaluating the method. The most influential extraction parameters were evaluated, including the ionic liquid, the composition of donor solution and acceptor solution, the extraction time and the extraction temperature, the effect of ionic strength, and the agitation speed. Under the most favorable extraction parameters, the method showed good linearity (from 0.05-50 to 0.5-50 μg/L, depending on the analytes) and repeatability of extractions (RSD below 8.3%, n=5). The proposed method was compared to conventional three-phase LLL-SBME and ionic liquid supported hollow fiber protected three-phase liquid-liquid-liquid microextraction, and showed higher extraction efficiency. The proposed method was demonstrated to be a simple, fast, and efficient method for the analysis of phenols from environmental water samples.  相似文献   

19.
A simple, environmentally friendly, and efficient method, based on hollow‐fiber‐supported liquid membrane microextraction, followed by high‐performance liquid chromatography has been developed for the extraction and determination of amlodipine (AML) and atorvastatin (ATO) in water and urine samples. The AML in two‐phase hollow‐fiber liquid microextraction is extracted from 24.0 mL of the aqueous sample into an organic phase with microliter volume located inside the pores and lumen of a polypropylene hollow fiber as acceptor phase, but the ATO in three‐phase hollow‐fiber liquid microextraction is extracted from aqueous donor phase to organic phase and then back‐extracted to the aqueous acceptor phase, which can be directly injected into the high‐performance liquid chromatograph for analysis. The preconcentration factors in a range of 34–135 were obtained under the optimum conditions. The calibration curves were linear (R2 ≥ 0.990) in the concentration range of 2.0–200 μg/L for AML and 5.0–200 μg/L for ATO. The limits of detection for AML and ATO were 0.5 and 2.0 μg/L, respectively. Tap water and human urine samples were successfully analyzed for the existence of AML and ATO using the proposed methods.  相似文献   

20.
Rapid extraction of eight different peptides using electromembrane extraction (EME) was demonstrated for the first time. During an extraction time of 5 min, the model peptides migrated from a 500 microL aqueous acidic sample solution, through a thin supported liquid membrane (SLM) of an organic liquid sustained in the pores in the wall of a porous hollow fiber, and into a 25 microL aqueous acidic acceptor solution present inside the lumen of the hollow fiber. The driving force of the extraction was a 50 V potential sustained across the SLM, with the positive electrode in the sample and the negative electrode in the acceptor solution. The nature and the composition of the SLM were highly important for the EME process, and a mixture of 1-octanol and 15% di(2-ethylhexyl) phosphate was found to work properly. Using 1mM HCl as background electrolyte in the sample and 100 mM HCl in the acceptor solution, and agitation at 1050 rpm, enrichment up to 11 times was achieved. Recoveries were found to be dependent on the structure of the peptide, indicating that the polarity and the number of ionized groups were important parameters affecting the extraction efficiency. The experimental findings suggested that electromembrane extraction of peptides is possible and may be a valuable tool for future extraction of peptides.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号