In this research, adiabatic two-phase air-water flow was investigated, and results for smooth and ribbed rectangular ducts are presented here. The test fluids were air and water at approximately atmospheric conditions. Three ribs of different heights were used; the rib width and pitch were held constant. The ribs were positioned in the duct at three different locations to establish three different conditions: on the bottom wall (water side), on the top wall (air side) and on both the top and bottom walls. The flow regimes in the smooth and ribbed ducts, which were recorded with a video camera, were classified as plug, stratified, slug and wavy flow. The location of the ribs in the duct did not alter the shape of the flow regimes, but the regime boundaries were considerably changed (repositioned). The effects of using ribs of different heights on regime boundaries are represented with flow map diagrams and discussed in detail. Compared to the smooth duct, the ribbed duct had different regime boundary positions. Increasing the rib height initiated hydrodynamical instability at lower fluid velocities. These findings are relevant for the operation and design of pipes, boilers and heat exchangers.  相似文献   

2.
To increase the thermal efficiency of gas turbines, inlet temperature of gas is increased. This results in the requirement of cooling of gas turbine blades and vanes. Internal cooling of gas turbine blades and vanes is one of several options. Two-pass channels are provided with ribs to enhance heat transfer at the expense of an increased pressure drop. The space in the blade is limited and requires channels with small aspect ratios. Numerical simulations have been performed to investigate heat transfer, flow field and pressure loss in a two-pass channel equipped with 45° ribs with aspect ratio (Win/H) equal to 1:3 in the inlet pass and 1:1 in the outlet pass with both connected together with a 180° bend. The results are compared with a higher aspect ratio channel (Win/H = 1:2, inlet pass). In the ribbed channel, a decrease in pressure drop was observed with a decrease in the aspect ratio of the channel. The smaller aspect ratio channel not only allows using more cooling channels in the blade, but also results in more heat transfer enhancement. The divider-to-tip wall distance (Wel) has influence on the pressure drop, as well as on the heat transfer enhancement at the bend and outlet pass. Heat transfer decreases with decrease in aspect ratio of the inlet pass of the two-pass channel. With increase in divider-to-tip wall distance, heat transfer tries to attain a constant value.  相似文献   

3.
In the present study, experimental studies are carried out to investigate the heat transfer and friction characteristics in a square duct roughened by various-shaped ribs on one wall. The ribs are oriented transversely to the main stream in a periodic arrangement. Liquid crystal thermography is employed to measure the local and average heat transfer coefficient on the ribbed surface. The rib height-to-duct hydraulic diameter ratio is fixed at 0.1; the rib pitch-to-height ratio varies from 8 to 15 and the test Reynolds number spans from 8,000 to 20,000. The results show that the trapezoidal-shaped ribs with decreasing height in the flow direction (case C) provide the highest heat transfer enhancement factor and are likely to be used to suppress the local hot spot which usually occurs in the region just behind the ribs.  相似文献   

4.
Turbulent heat transfer in a ribbed square duct of three different blockage ratios are investigated using direct numerical simulation (DNS). The results of ribbed duct cases are compared with those of a heated smooth duct flow. It is observed that owing to the existence of the ribs and confinement of the duct, organized secondary flows appear as large streamwise-elongated vortices, which intensely interact with the rib elements and four sidewalls and have profound influences on the transport of momentum and thermal energy. This study also shows that the drag and heat transfer coefficients are highly sensitive to the rib height. It is observed that as the rib height increases, the impinging effect of the flow on the windward face of the rib strengthens, leading to enhanced rates of turbulent mixing and heat transfer. The influence of sidewalls and rib height on the turbulence structures associated with temperature fluctuations are analyzed based on multiple tools such as vortex swirling strengths, temporal auto-correlations, spatial two-point cross-correlations, joint probability density functions (JPDF) between the temperature and velocity fluctuations, statistical moments of different orders, and temperature spectra.  相似文献   

5.
In the present study, the regionally-averaged heat transfer coefficients and flow temperature distributions were measured in an equilateral triangular channel with three different rib arrangements (α = 45, 90 and 135°). To measure regionally-averaged heat transfer coefficients in the channel, two rows of copper blocks and a single heater were installed on two ribbed walls. The fluid temperature distributions were obtained using a thermocouple-array. The rotation number ranged from 0.0 to 0.1 with a fixed Reynolds number of 10,000. For the 90° ribs, the heat transfer coefficients on the pressure side surface were increased significantly with rotation, while the suction side surface had lower heat transfer coefficients than the stationary channel. For the angled ribs, rib-induced secondary flow dominated the heat transfer characteristics and high heat transfer rates were observed on the regions near the inner wall for the 45° angled ribs and near the leading edge for the 135° angled ribs.  相似文献   

6.
Flow boiling heat transfer in a vertical spirally internally ribbed tube   总被引:3,自引:0,他引:3  
 Experiments of flow boiling heat transfer and two-phase flow frictional pressure drop in a spirally internally ribbed tube (φ22×5.5 mm) and a smooth tube (φ19×2 mm) were conducted, respectively, under the condition of 6×105 Pa (absolute atmosphere pressure). The available heated length of the test sections was 2500 mm. The mass fluxes were selected, respectively, at 410, 610 and 810 kg/m2 s. The maximum heat flux was controlled according to exit quality, which was no more than 0.3 in each test run. The experimental results in the spirally internally ribbed tube were compared with that in the smooth tube. It shows that flow boiling heat transfer coefficients in the spirally internally ribbed tube are 1.4–2 times that in the smooth tube, and the flow boiling heat transfer under the condition of smaller temperature differences can be achieved in the spirally internally ribbed tube. Also, the two-phase flow frictional pressure drop in the spirally internally ribbed tube increases a factor of 1.6–2 as compared with that in the smooth tube. The effects of mass flux and pressure on the flow boiling heat transfer were presented. The effect of diameters on flow boiling heat transfer in smooth tubes was analyzed. Based on the fits of the experimental data, correlations of flow boiling heat transfer coefficient and two-phase flow frictional factor were proposed, respectively. The mechanisms of enhanced flow boiling heat transfer in the spirally internally ribbed tube were analyzed. Received on 1 December 1999  相似文献   

7.
In this paper, the heat/mass transfer analogy was used to investigate the heat transfer and pressure drop in a square channel with triangular ribs on its two opposite walls. Reynolds number varied from 1 × 104 to 7 × 104; the dimensionless heights of the triangular ribs H/W were 0.04, 0.07, and 0.1; and their dimensionless pitches S/W were 0.45, 0.63, 1.0, 1.37, 1.55, and 2.1. Experimental results showed that the heat transfer coefficients of the wall with triangular rib were about 1 to 2.3 times larger than those of a smooth-channel wall, and the pressure drops along this roughened channel were about 1 to 10 times larger than those for a smooth channel. Correlations of heat transfer and pressure drop were obtained, which are useful for practical designs.  相似文献   

8.
The issue of turbine lifetime is an important one, particularly for modern turbines operating at high temperature regimes. A cooling design such as ribs may achieve an improved lifetime and complex mechanisms of heat transfer need to be well studied. In this paper, a Direct Numerical Simulation (DNS) is presented for a 3-D channel flow with two square ribs on the lower wall. The full unsteady compressible Navier-Stokes equations are solved with an original hybrid finite difference/finite element scheme. The Reynolds number of the simulation is 7 000 based on the bulk velocity at the inlet and the channel height. The present study is mainly devoted to understand the mechanism of heat transfer at the wall through the topological analysis of the flow and the temperature flux. Results show that the large-scale structures generated by obstacles splash onto the lower surface and induce longitudinal vortices which enhance heat transfer at the wall. A comprehensive data base including 56 correlations was set up for testing and improving turbulence models for this complex, separated flow.  相似文献   

9.
Experimental investigation had been conducted to study the steady-state forced convection heat transfer and pressure drop characteristics of the hydrodynamic fully-developed turbulent flow in the air-cooled horizontal equilateral triangular ducts, which were fabricated with the same length and hydraulic diameter. Inner surfaces of the ducts were fixed with square ribs with different side lengths of 6.35, 9.525 and 12.7 mm, respectively, and the uniform separation between the centre lines of two adjacent ribs was kept constant at 57.15 mm. Both the triangular ducts and the ribs were fabricated with duralumin. The experiments were performed with the hydraulic diameter based Reynolds number ranged from 3100 to 11300. The entire inner wall of the duct was heated uniformly, while the outer surface was thermally insulated. It was found that the Darcy friction factor of the duct was increasing rather linearly with the rib size, and forced convection could be enhanced by an internally ribbed surface. However, the heat transfer enhancement was not proportional to the rib size but a maximum forced convection heat transfer augmentation was obtained at the smallest rib of 6.35 mm. Non-dimensional expressions for the determination of the steady-state heat transfer coefficient and Darcy friction factor of the equilateral triangular ducts, which were internally fabricated with uniformly spaced square ribs of different sizes, were also developed. Received on 25 May 1999  相似文献   

10.
Two-pass internal cooling passage with rib turbulators has been investigated for convective heat/mass transfer under rotating conditions. The flow and heat transfer characteristics in the cooling passage are very complicated so that it is required the detail analysis to design more efficient gas turbine blades. A naphthalene sublimation technique is employed to determine detailed local heat transfer coefficients using the heat and mass transfer analogy. The local heat/mass transfer and flow pattern in the cooling passage are changed significantly according to rib configurations, duct turning geometries and duct rotation speeds. Four different rib configurations are investigated to obtain the combined effects of the angled rib, duct turning and rotation. The results show that the duct rotation generates the heat/mass transfer discrepancy between the leading and trailing walls due to the secondary flows induced by the Coriolis force. The angled ribs generate a single rotating secondary flow with the cross-rib arrangement and the duct turning makes a strong Dean-type vortex. These vortices affect significantly the heat/mass transfer on the duct wall. The overall heat transfer pattern on the leading and trailing surfaces for the first and second passes are dependent on the duct rotation, but the local heat transfer trend is affected mainly by the rib arrangements. In addition, the present study observes the rotating effect in the two-pass smooth duct to obtain the baseline data in comparison with the ribbed duct for various rib arrangements.  相似文献   

11.
The present study investigates convective heat/mass transfer and flow characteristics inside a cooling passage of rotating gas-turbine blades. The rotating duct with and without rib turbulators are used. The ribs of 70° attack angle are attached on leading and trailing surfaces in a staggered arrangement. A naphthalene sublimation technique is employed to determine detailed local heat transfer coefficients using the heat and mass transfer analogy. Additional numerical calculations are conducted to analyze the flow patterns in the cooling. The local heat/mass transfer and the flow pattern in the passage are changed significantly according to rib configurations, duct turning geometry and duct rotation speed. The results show that the duct rotation generates the heat transfer discrepancy between the leading and trailing walls due to the secondary flows induced by the Coriolis force. The heat/mass transfer on the ribbed duct shows 80% higher than the smooth duct because the ribs attached on the walls disturb the mainflow resulting in recirculation and secondary flows near the rib with the secondary flow generated by rotation. The overall heat transfer pattern on the leading and trailing walls for the first and second passes depend on the rotating speed and the turning geometry, but the local heat transfer trend is affected mainly by the rib arrangeements.  相似文献   

12.
A numerical investigation is performed on the electroosmotic flow (EOF) in a surface-modulated microchannel to induce enhanced solute mixing. The channel wall is modulated by placing surface-mounted obstacles of trigonometric shape along which the surface potential is considered to be different from the surface potential of the homogeneous part of the wall. The characteristics of the electrokinetic flow are governed by the Laplace equation for the distribution of external electric potential; the Poisson equation for the distribution of induced electric potential; the Nernst–Planck equations for the distribution of ions; and the Navier–Stokes equations for fluid flow simultaneously. These nonlinear coupled set of governing equations are solved numerically by a control volume method over the staggered system. The influence of the geometric modulation of the surface, surface potential heterogeneity and the bulk ionic concentration on the EOF is analyzed. Vortical flow develops near a surface modulation, and it becomes stronger when the surface potential of the modulated region is in opposite sign to the surface potential of the homogeneous part of the channel walls. Vortical flow also depends on the Debye length when the Debye length is in the order of the channel height. Pressure drop along the channel length is higher for a ribbed wall channel compared to the grooved wall case. The pressure drop decreases with the increase in the amplitude for a grooved channel, but increases for a ribbed channel. The mixing index is quantified through the standard deviation of the solute distribution. Our results show that mixing index is higher for the ribbed channel compared to the grooved channel with heterogeneous surface potential. The increase in potential heterogeneity in the modulated region also increases the mixing index in both grooved and ribbed channels. However, the mixing performance, which is the ratio of the mixing index to pressure drop, reduces with the rise in the surface potential heterogeneity.  相似文献   

13.
Performance evaluation of surface roughened compact channels for heat transfer applications has been investigated using non-intrusive, real time laser-based interferometric technique with water as the coolant medium. The lower wall of the channel has been roughened by creating hemispherical inward dimples. Projection data of the temperature field has been recorded using a Mach Zehnder interferometer. In order to facilitate direct comparison, experiments have also been conducted in smooth channel of similar dimensions. Results have been presented in the form of thermal boundary layer profiles, whole field temperature distributions and local variations of heat transfer coefficients. Direct interferometric measurements clearly reveal the disruption of thermal boundary layer due to the presence of inward dimples. Near wall temperature gradients were seen to be stronger in the case of dimpled channel in comparison with that of the smooth one resulting into a clear enhancement in heat transfer rates. At low Reynolds numbers, variation of heat transfer coefficients along the length of the dimpled channel showed the presence of local maxima. On the other hand, the corresponding profiles for the smooth channels showed a monotonic decrease with respect to the axial direction. The dynamic measurements, that are purely non-intrusive, revealed an improved thermal performance of surface roughened compact channels.  相似文献   

14.
In the present study, the thermal and hydraulic performance of three rib-roughened rectangular ducts is investigated. The aspect ratio of the ducts was 1 to 8, and the ribs were arranged staggered on the two wide walls. Three rib configurations were tested: parallel ribs and V-shaped ribs pointing upstream or downstream of the main flow direction. For all cases, the rib height-to-hydraulic diameter ratio was 0.06, with an attack angle of 60° and a pitch-to-height ratio of 10. The Reynolds number range was from 1000 to 6000. Liquid crystal thermography was employed in the heat transfer experiment to demonstrate detailed temperature distribution between a pair of ribs on the ribbed surfaces. The secondary flows caused by the inclined ribs create a significant spanwise variation of the heat transfer coefficients on the rib-roughened wall with high heat transfer coefficient at one end of the rib and low value at the other. In the streamwise direction between two consecutive ribs, the temperature distribution shows a sawtooth fashion because of flow reattachment. Based on the local heat transfer coefficients, the average Nusselt numbers were estimated as weighted mean values. Isothermal pressure drop data were taken and presented as Fanning friction factors. The ducts are compared to each other by considering both heat transfer and friction factor performance.  相似文献   

15.
Using steam as working fluid to replace compressed air is a promising cooling technology for internal cooling passages of blades and vanes. The local heat transfer characteristics and the thermal performance of steam flow in wide aspect ratio channels (W/H = 2) with different angled ribs on two opposite walls have been experimentally investigated in this paper. The averaged Nusselt number ratios and the friction factor ratios of steam and air in four ribbed channels were also measured under the same test conditions for comparison. The Reynolds number range is 6,000–70,000. The rib angles are 90°, 60°, 45°, and 30°, respectively. The rib height to hydraulic diameter ratio is 0.047. The pitch-to-rib height ratio is 10. The results show that the Nusselt number ratios of steam are 1.19–1.32 times greater than those of air over the range of Reynolds numbers studied. For wide aspect ratio channels using steam as the coolant, the 60° angled ribs has the best heat transfer performance and is recommended for cooling design.  相似文献   

16.
 Results of a comparative evaluation of three heat transfer enhancement strategies for forced convection cooling of a parallel plate channel populated with heated blocks, representing electronic components mounted on printed circuit boards, are reported. Heat transfer in the reference geometry, the asymmetrically heated parallel plate channel, is compared with that for the basic grooved channel, and the same geometry enhanced by cylinders and vanes placed above the downstream edge of each heated block. In addition to conventional heat transfer and pressure drop measurements, holographic interferometry combined with high-speed cinematography was used to visualize the unsteady temperature fields in the self-sustained oscillatory flow. The locations of increased heat transfer within one channel periodicity depend on the enhancement technique applied, and were identified by analyzing the unsteady temperature distributions visualized by holographic interferometry. This approach allowed gaining insight into the mechanisms responsible for heat transfer enhancement. Experiments were conducted at moderate flow velocities in the laminar, transitional and turbulent flow regimes. Reynolds numbers were varied in the range Re = 200–6500, corresponding to flow velocities from 0.076 to 2.36 m/s. Flow oscillations were first observed between Re = 1050 and 1320 for the basic grooved channel, and around Re = 350 and 450 for the grooved channels equipped with cylinders and vanes, respectively. At Reynolds numbers above the onset of oscillations and in the transitional flow regime, heat transfer rates in the investigated grooved channels exceeded the performance of the reference geometry, the asymmetrically heated parallel plate channel. Heat transfer in the grooved channels enhanced with cylinders and vanes showed an increase by a factor of 1.2–1.8 and 1.5–3.5, respectively, when compared to data obtained for the basic grooved channel; however, the accompanying pressure drop penalties also increased significantly. Received on 5 April 2001  相似文献   

17.
Artificial roughness in the form of ribs is a convenient method for enhancing thermal performance of solar air heaters. This paper presents the experimental investigation of heat transfer and friction factor characteristics of a rectangular duct roughened with W-shaped ribs arranged at an inclination with respect to the flow direction on its underside on one broad wall. W ribs have been tested both pointing in downstream W-down and upstream W-up to the flow. The range of parameters for this study has been decided on the basis of practical considerations of the system and operating conditions. The duct has a width to height ratio (W/H) of 8.0, relative roughness pitch (p/e) of 10, relative roughness height (e/Dh) of 0.03375 and angle of attack of flow (α) of 30-75°. The air flow rate corresponds to Reynolds number between 2300-14,000. The heat transfer and friction factor results have been compared with those for smooth duct under similar flow and thermal boundary condition and thermo-hydraulic performance has been investigated. Thermo-hydraulic performance comparison for different angle of attack of flow shows that W-down arrangement with angle of attack of flow as 60° gives best thermo-hydraulic performance. In addition heat transfer and friction factor correlations have been developed.  相似文献   

18.
This work presents the experimental research on the steady laminar natural convection heat transfer of air in three vertical thin rectangular channels with different gap clearance. The much higher ratio of width to gap clearance (60–24) and the ratio of length to gap clearance (800–320) make the rectangular channels similar with the coolant flow passage in plate type fuel reactors. The vertical rectangular channels were composed of two stainless steal plates and were heated by electrical heating rods. The wall temperatures were detected with the K-type thermocouples which were inserted into the blind holes drilled in the steal plates. Also the air temperatures at the inlet and outlet of the channel were detected. The wall heat fluxes added to the air flow were calculated by the Fourier heat conduction law. The heat transfer characteristics were analyzed, and the average Nusselt numbers in all the three channels could be well correlated with the Rayleigh number or the modified Rayleigh number in a uniform correlation. Furthermore, the maximum wall temperatures were investigated, which is a key parameter for the fuel’s integrity during some accidents. It was found that even the wall heat flux was up to 1500 W/m2, the maximum wall temperature was lower than 350 °C. All this work is valuable for the plate type reactor’s design and safety analysis.  相似文献   

19.
The local heat transfer and pressure drop characteristics of developing turbulent flows of air in three stationary ribbed square ducts have been investigated experimentally. These are: ribbed square duct with constant cross-section (straight duct), ribbed divergent square duct and ribbed convergent square duct. The convergent/divergent duct has an inclination angle of 1°. The measurement was conducted within the range of Reynolds numbers from 10 000 to 77 000. The heat transfer performance of the divergent/convergent ducts is compared with the ribbed straight duct under three constraints: identical mass flow rate, identical pumping power and identical pressure drop. Because of the streamwise flow acceleration or deceleration, the local heat transfer characteristics of the divergent and convergent ducts are quite different from those of the straight duct. In the straight duct, the fluid flow and heat transfer become fully developed after 2–3 ribs, while in the divergent and convergent ducts there is no such trend. The comparison shows that among the three ducts, the divergent duct has the highest heat transfer performance, the convergent duct has the lowest, while the straight duct locates somewhere in between.  相似文献   

20.
An experimental study in an open-ended vertical channel is carried out in order to describe the fluid dynamics and heat transfer of transient free convection inside a vertical rib-roughened channel asymmetrically heated at various uniform heat fluxes (650, 700, and 780 W/m2) corresponding to various modified Rayleigh numbers (3.65 × 106, 3.93 × 106 and 4.4 × 106). Two ribs are symmetrically located on each wall. The investigations focused more specifically on the influence of the ribs positions inside the channel and the modified Rayleigh number (Ra*) both in steady-state regime and during the transitional phase occurring just after the start of the heating on the flow structure and the heat transfer performance. The results showed the appearance of large-scale flow instabilities which will develop and propagate until the development of the pocket-like vortex (reversed flow). Also, the formation and breakup of recirculation eddies, vortex banishment, besides that a separation and shifting of the boundary layer from one wall to another are identified. The best position of the ribs for heat extraction depends on the magnitude of the Rayleigh number. In that case, the top position is the optimal position for the small and the moderate modified Rayleigh numbers.  相似文献   