首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Glutathione (GSH) is a tripeptide composed of glutamate, cysteine, and glycine. It is present in practically all cells and has several important roles, such as preventing the oxidation of the sulfhydryl groups of proteins within a cell. Evidence for GSH deficiency or depletion has been found in a variety of diseases and toxicity-related studies, including diabetes and induction of oxidative stress to form reactive oxygen species which cause DNA, lipid, and protein oxidations. A simple, selective, and sensitive analytical method for measuring low levels of GSH in biological fluids would therefore be desirable to conduct GSH deficiency or depletion-related mechanistic toxicity studies. Here a method for both low- and high-level quantitation of GSH from cultured cells and rat liver tissues via liquid chromatography/positive electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) has been developed. The lower limit of quantitation (LOQ) of the method was 5 ng/mL. The method is linear over a wide dynamic concentration range of 5.0 to 5000.0 ng/mL, with a correlation coefficient R2 > 0.99. The intra-day assay precision relative standard deviation (RSD) values for all quality control (QC) samples were < or =16.31%, with accuracy values ranging from 94.13 to 97.80%. The inter-day assay precision RSD values for all QC samples were < or =15.94%, with accuracy values ranging from 94.51 to 100.29%. With this method, low levels of GSH from diethyl maleate (DEM)-treated mouse lymphoma cells, and GSH in rat liver tissues, were quantified.  相似文献   

2.
N-acetylaspartic acid (NAA) is a specific urinary marker for Canavan disease, an autosomal recessive leukodystrophy. We developed a 'dilute and shoot' stable isotope dilution liquid chromatography tandem mass spectrometry (LC-MS/MS) method for determination of NAA in urine. Deuterated internal standard d(3)-NAA was added to untreated urine and the mixture was injected into the LC-MS/MS system operated in the negative ion mode. Chromatography was carried out on a C(8) minibore column using 50% acetonitrile solution containing 0.05% formic acid at a flow rate of 0.25 mL/min. The retention time was 1.6 min and the turnaround time was 2.2 min. NAA and d(3)-NAA were analyzed in multiple reaction monitoring mode. Calibrators and quality control samples were prepared in pooled control urine. The assay was linear up to 2000 micromol/L with limit of quantification at 1 micromol/L (S/N = 12). Interassay and intraassay coefficients of variation were less than 7% and recovery at three different concentrations was 98.9-102.5%. The LC-MS/MS method for NAA as described involves no extraction and no derivatization, showed no interference and gave excellent recovery with low variability and short analytical time. The method was successfully applied for the retrospective analysis of urine from 21 Canavan disease cases.  相似文献   

3.
A precise and accurate stable isotope dilution liquid chromatography/tandem mass spectrometry method for the analysis of intracellular homocysteine has been developed. An internal standard, [(2)H(8)]-homocystine, was added to cell pellets from EA.hy 926 cells grown in culture under low and high folate concentrations. D,L-dithiothreitol was used to reduce cellular homocystine to homocysteine. Cellular proteins were precipitated by the addition of formic acid in acetonitrile. After centrifugation, a portion of the supernatant was analyzed by liquid chromatography/tandem mass spectrometry. Using a Supelcosil cyano column with an Applied Biosystems API 4000 triple quadrupole mass spectrometer, the SRM transitions for homocysteine (m/z 136 to m/z 90) and [(2)H(4)]-homocysteine (m/z 140 to m/z 94) were monitored. The method was validated by conducting five replicate analyses on three different days at four different concentrations (concentrations at the lower limit of quantitation and expected lower quartile, mid-range and upper quartile). The limit of detection was 2 ng/10(6) EA.hy 926 cells. Using this method, the intracellular homocysteine concentration in EA.hy 926 cells ranged from 10 to 36 ng/10(6) cells.  相似文献   

4.
5.
A new method was developed for the analysis of nitrate and nitrite in a variety of water matrices by using reversed-phase liquid chromatography/electrospray ionization/mass spectrometry in the negative ion mode. For this direct analysis method, nitrate and nitrite anions were well separated under the optimized LC conditions, detected by monitoring m/z 62 and m/z 46 ions, and quantitated by using an isotope dilution technique that utilized the isotopically labeled analogs. The method sensitivity, accuracy, and precision were investigated, along with matrix effects resulting from common inorganic matrix anions. The isotope dilution technique, along with sample pretreatment using barium, silver, and hydrogen cartridges, effectively compensated for the ionization suppression caused by the major water matrix anions, including chloride, sulfate, phosphate, and carbonate. The method detection limits, based on seven reagent water replicates fortified at 0.01 mg N/L nitrate and 0.1 mg N/L nitrite, were 0.001 mg N/L for nitrate and 0.012-0.014 mg N/L for nitrite. The mean recoveries from the replicate fortified reagent water and lab water samples containing the major water matrix anions, were 92-103% for nitrate with an imprecision (relative standard deviation, RSD) of 0.4-2.1% and 92-110% for nitrite with an RSD of 1.1-4.4%. For the analysis of nitrate and nitrite in drinking water, surface water, and groundwater samples, the obtained results were generally consistent with those obtained from the reference methods. The mean recoveries from the replicate matrix spikes were 92-123% for nitrate with an RSD of 0.6-7.7% and 105-113% for nitrite with an RSD of 0.3-1.8%.  相似文献   

6.
A rapid, sensitive and selective method for the simultaneous determination of bromadiolone, flocoumafen and brodifacoum in whole blood using warfarin as internal standard (IS) by high-performance liquid chromatography coupled with electrospray ionization mass spectrometry (HPLC/ESI-MS) has been developed and validated. The target compounds were extracted from the whole blood with ethyl acetate and separated on an XDB C18 column (150 mm x 2.1 mm i.d. x 5 microm) by using a mobile phase consisting of 0.2% acetic acid/methanol (12/88, v/v) at a constant flow rate of 0.50 mL/min. The analytes were detected using negative ESI-MS in the selected ion monitoring (SIM) mode. The molecular ions [M-H]- of m/z 527, 541,523 and 307 were selected for the quantification for bromadiolone, flocoumafen, brodifacoum and the IS, respectively. The calibration curves were linear (r2 > 0.995) in the concentration range of 0.50-100.00 ng/mL. The method showed a satisfactory sensitivity (0.05-0.5 ng/mL using 200 microL blood), precision (RSD < 11.9%), accuracy (recovery: 82.0-96.1%) and selectivity. This method was successfully applied to the determination of the analytes for the diagnoses of poisoned human beings and animals.  相似文献   

7.
A rapid and very sensitive high-performance liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) method for the simultaneous determination of dithiocarbamate (DTC) fungicide residues in fruits and vegetables was developed. The surface extraction of samples used an alkaline buffer consisting of sodium hydrogen carbonate and DL-penicillamine. The three DTC subclasses, i.e. dimethyldithiocarbamates (DMDs), ethylenebis(dithiocarbamates) (EBDs), and propylenebis(dithiocarbamates) (PBDs), were separated on a Sequant ZIC-pHILIC column using an acetonitrile/10 mM ammonia gradient. Because of the instability of DTC residues extracted from plant samples, a stable isotope dilution assay was applied. For each DTC subclass, the limits of detection and quantification were approximately 0.03 mg kg(-1) and 0.05 mg kg(-1), respectively. Recoveries from grapes, cucumbers, tomatoes, and rucola, spiked in the range of 0.01-0.9 mg kg(-1), averaged between 90 and 100%.  相似文献   

8.
Liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) is one of the most prominent analytical techniques owing to its inherent selectivity and sensitivity. In LC/ESI-MS/MS, chemical derivatization is often used to enhance the detection sensitivity. Derivatization improves the chromatographic separation, and enhances the mass spectrometric ionization efficiency and MS/MS detectability. In this review, an overview of the derivatization reagents which have been applied to LC/ESI-MS/MS is presented, focusing on the applications to low molecular weight compounds.  相似文献   

9.
Hemoglobin adducts are often used as biomarkers for exposure to reactive chemicals in toxicology studies. Therefore, fast, sensitive, accurate, and reproducible methods for quantifying these protein adducts are key to evaluate test material dosimetry. A methodology has been developed for the quantitation of methylated hemoglobin adducts isolated from rats exposed to the model alkylating agent: methyl methane sulfonate (MMS). After 4 days of MMS exposure by oral gavage, hemoglobin was isolated from rat blood and digested with trypsin. The tryptic digestion solution was used for the adducted hemoglobin signature peptide quantitation via liquid chromatography/negative tandem mass spectrometry (LC/ESI-MS/MS). The limit of quantitation (LOQ) for the methylated hemoglobin beta chain N-terminal signature peptide (MeVHLTDAEK) was 1.95 ng/mL (5.9 pmol/mg globin). The calibration curves were linear over a concentration range of 1.95 to 625 ng/mL, with a correlation coefficient R2 >0.998, accuracy of 85.8 to 119.3%, and precision of 0.9 to 19.4%.  相似文献   

10.
Crop control is an important issue in both developed and developing countries. An environmentally friendly approach is represented by the so‐called Integrated Pest Management (IPM), whereby synthetic pesticides are only applied as a last resort, under the strict control of suitable experts. European and US regulatory authorities, such as the US EPA, are constantly assessing the risks of exposure to the organophosphate (OP) class of pesticides and, among these, specifically dimethoate. The use of dimethoate is still allowed in many crops, including olives, which once was based in the Mediterranean area but now is expanding rapidly throughout the world. An important aspect of IPM protocols is represented by the availability of reliable and sensitive methods to detect pesticides residues. This paper describes an isotope dilution dimethoate assay based on the application of electrospray ionization tandem mass spectrometry (ESI‐MS/MS) by means of a deuterium‐labeled internal standard. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

11.
The 40 and 42 amino-acid residue forms of amyloid beta (Abeta(1-40) and Abeta(1-42)) in cerebrospinal fluid (CSF) have been proposed as potential biomarkers of Alzheimer's disease (AD). Quantitative analyses of Abeta peptides in CSF have relied almost exclusively on the use of immunoassay-based assays such as the enzyme-linked immunosorbent assay (ELISA) procedure. However, due to the ability of the Abeta peptides to readily self-aggregate or bind to other proteins and glassware, such analyses are extremely challenging. Analyses are further complicated by the potential of the peptides to undergo post-translational modifications and the possibilities for cross-reaction in the ELISA assays with endogenous components of the CSF. An approach based on liquid chromatography/tandem mass spectrometry (LC/MS/MS) has now been developed which overcomes these methodological issues. The key steps in implementing this new approach involved immunoaffinity purification coupled with the use of [15N]-labeled Abeta peptides as internal standards, a basic LC mobile phase, negative ion electrospray ionization, and a basic solvent for dissolving the peptides and washing the injection needle to prevent carryover of analytes during multiple injections on the LC/MS system. The validated method had limits of quantitation of 44 fmol/mL (200 pg/mL) for Abeta(1-42) and 92 fmol/mL (400 pg/mL) for Abeta(1-40). An excellent correlation was found between the LC/MS/MS assay and an ELISA assay for Abeta(1-42) in human CSF (r2 = 0.915), although less correlation was observed for Abeta(1-40) (r2 = 0.644). Mean CSF Abeta(1-42) concentrations for samples collected 2 weeks apart from a limited number of AD patients provided additional confidence in the reproducibility of the LC/MS/MS assay. Concentrations for duplicate samples from AD patients were slightly higher than most previously reported values (mean 1.06 +/- 0.25 ng/mL; n = 7). Abeta(1-40) concentrations in duplicate samples obtained from AD patients were also reproducible but were found to be slightly lower than most previously reported values (mean 6.36 +/- 3.07 ng/mL; n = 7). Consistent with literature reports, mean Abeta(1-42) concentrations were found to be lower in AD patients compared with the normal subjects (mean 1.49 +/- 0.59 ng/mL; n = 7), whereas there was no difference in Abeta(1-40) concentrations between AD patients and normal subjects (mean 5.88 +/- 3.03 ng/mL; n = 7). The accuracy and precision of the LC/MS assay mean that it will be a useful complement to existing ELISA assays for monitoring therapeutic interventions designed to modulate CSF Abeta(1-42) concentrations in individual AD patients. Moreover, the introduction of stable isotope labeled internal standards offers the potential to achieve a more rigorous account of the influence of methodological effects related to sample collection and processing.  相似文献   

12.
A phospholipid mixture extracted from cultured cells was directly analyzed by capillary (Cap) liquid chromatography (LC)/electrospray ionization (ESI) mass spectrometry (MS). Using a quadrupole mass spectrometer, we analyzed positive molecular ions, negative molecular ions, positive fragment ions and negative fragment ions under four different functions. In the analysis of the elution patterns of the phospholipids, a two-dimensional map, in which the first dimension is elution time and the second dimension is mass, proved useful. Consequently, four different maps can be obtained by each of four different functions. Among them, from negative fragment ions at high cone voltage in the negative ion mode, ions that originated from acyl fatty acid and phosphorylcholine, phosphorylethanolamine and cyclic inositol phosphate can be detected at specific elution times. The map from positive fragment ions at high cone voltage in the positive ion mode indicated ions such as diradylglycerol and derivatives of 1-alkyl or 1-alkenyl cyclic phosphatidic acid from phosphatidylethanolamine (PE), and phosphorylcholine from choline-containing phospholipids. The map produced from positive molecular ions indicated choline-containing phospholipids such as phosphatidylcholine, sphingomyelin, lysophosphatidylcholine and PE. The map of negative molecular ions effectively indicated acidic phospholipids such as phosphatidylinositol. We were able to obtain more than 500 molecular species of phospholipids by this method within a few hours immediately after extraction from culture cells using a mixture of chloroform and methanol (2:1). In this context, we concluded that the combination of Cap-LC and ESIMS seems to be very effective in the analysis of phospholipid classes and their molecular species.  相似文献   

13.
5-Fluorouracil (5-FU) has long had a place in the treatment of many malignancies. 5-FU plasma concentrations have been correlated with toxicity and efficacy, and therapeutic drug monitoring has been reported to result in an improved response/toxicity balance. We report validation, according to FDA guidelines, of a hydrophilic interaction chromatography (HILIC) liquid chromatography/tandem mass spectrometry (LC/MS/MS) assay for the sensitive, accurate and precise quantitation of 5-FU in human plasma. The assay employed an isotopically labeled 5-FU internal standard and ethyl acetate extraction. Separation was achieved with an amino column and an isocratic mobile phase of 0.1% formic acid in acetonitrile/water (97:3, v/v), followed by a wash. Detection consisted of electrospray, negative-mode ionization tandem mass spectrometry in the multiple reaction monitoring (MRM) mode. The accuracy was 96.0-102.2%, and precision was 2.1-7.5% in the concentration range of 10-10 000 ng/mL. Recovery from plasma was 46.0-72.6%, and ion suppression was 9.8-25.7%. Plasma freeze/thaw stability was 87.5-104.3%, and stability for 4 h at room temperature was 98.7-100.0%. This assay is currently being used to quantitate 5-FU in human plasma samples.  相似文献   

14.
In order to identify new biomarkers for pulmonary diseases in exhaled breath condensate (EBC) it was the aim of this study to develop an analytical method for the identification and quantification of N epsilon-(carboxymethyl)lysine (CML) in EBC. As detection by liquid chromatography with positive electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) offers the advantage of structurally related detection with the necessary specificity required for the identification of a substance, it was the method chosen for the determination of the non-volatile compound. Specific mass transitions and comparison of retention times with standards under given conditions were used for the unequivocal identification of CML in EBC of healthy subjects. Synthesis of isotopically labelled CML was performed and used as an internal standard for an accurate determination. It was possible to identify the advanced glycation end-product CML in 8 out of 10 healthy subjects. The concentration range determined in the quantifiable examined samples ranged between 35 and 110 pg/mL. EBC samples from 11 patients with different diseases such as diabetes and chronic obstructive pulmonary disease were also measured. In one patient with pneumonia a concentration of 1509 pg CML/mL EBC could be detected. This is the first time that CML has been identified and determined in EBC. The developed LC/ESI-MS/MS method could be used to address the utility of CML as a biomarker in pulmonary diseases.  相似文献   

15.
Tomato (Lycopersicon esculentum Mill.) is the second most important fruit crop worldwide. Tomatoes are a key component in the Mediterranean diet, which is strongly associated with a reduced risk of chronic degenerative diseases. In this work, we use a combination of mass spectrometry (MS) techniques with negative ion detection, liquid chromatography/electrospray ionization linear ion trap quadrupole‐Orbitrap‐mass spectrometry (LC/ESI‐LTQ‐Orbitrap‐MS) and liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI‐MS/MS) on a triple quadrupole, for the identification of the constituents of tomato samples. First, we tested for the presence of polyphenolic compounds through generic MS/MS experiments such as neutral loss and precursor ion scans on the triple quadrupole system. Confirmation of the compounds previously identified was accomplished by injection into the high‐resolution system (LTQ‐Orbitrap) using accurate mass measurements in MS, MS2 and MS3 modes. In this way, 38 compounds were identified in tomato samples with very good mass accuracy (<2 mDa), three of them, as far as we know, not previously reported in tomato samples. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

16.
Grape antioxidant dietary fiber (GADF) is a dietary supplement that combines the benefits of both fiber and antioxidants that help prevent cancer and cardiovascular diseases. The antioxidant polyphenolic components in GADF probably help prevent cancer in the digestive tract, where they are bioavailable. Mass spectrometry coupled to liquid chromatography is a powerful tool for the analysis of complex plant derivatives such as GADF. We use a combination of MS techniques, namely liquid chromatography/electrospray ionization time-of-flight mass spectrometry (LC/ESI-TOF-MS) and liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) on a triple quadrupole, for the identification of the polyphenolic constituents of the soluble fraction of GADF. First, we separated the mixture into four fractions which were tested for phenolic constituents using the TOF system in the full scan mode. The high sensitivity and resolution of the TOF detector over the triple quadrupole facilitate the preliminary characterization of the fractions. Then we used LC/ESI-MS/MS to identify the individual phenols through MS/MS experiments (product ion scan, neutral loss scan, precursor ion scan). Finally, most of the identities were unequivocally confirmed by accurate mass measurements on the TOF spectrometer. LC/ESI-TOF-MS combined with MS/MS correctly identifies the bioactive polyphenolic components from the soluble fraction of GADF. High-resolution TOF-MS is particularly useful for identifying the structure of compounds with the same LC/ESI-MS/MS fragmentation patterns.  相似文献   

17.
Analytical techniques for the detection of small amounts of explosives (in the picogram range) are now involved in various application. Some of them concern soil, water and air monitoring in order to face environmental problems related to improper handling procedures either in stocking or in wasting of the explosive products. Other areas are strictly related to forensic analysis of samples coming either from explosion areas where the matrix is various (metal, glass, wood, scraps), or from explosives transportation related to international terrorism. Generally speaking, for these applications the bulk of the matrix seriously interferes in the detection of the explosive analyte, which is usually present at trace levels. Unfortunately, despite some improvements, analytical techniques developed up today in this domain are still faced to two main constraints: the introduction of new products with unanticipated chemico-physical properties and the requirement of a routine and fast analytical method which can handle any matrix with a minimal clean-up and performing a sensitivity compatible either with the ever-decreasing demanded detection limit and with the ever-decreasing available specimen amount. These requirements can be fulfilled now by the new LC-MS and LC-MSMS techniques: mass spectrometry (MS) is likely an universal detector but even specific, especially when implemented in tandem MS (MSMS); LC is by far the most suitable technique to handle such a kind of compounds. Moreover, of a particular concern are some explosives which are reported to be thermally stable but difficult to dissolve. Some of the experiments on characterization of explosives [Octagen (HMX), Ethyleneglycol dinitrate (EGDN), Exogen (RDX), Propanetriol trinitrate (NG), Trinitrotoluene (TNT), N-Methyl-N-tetranitrobenzenamine (TETRYL), Dintrotoluene (DNT), Bis-(nitrooxy-methyl) propanediol dinitrate (PETN), Hexanitrostilbene (HNS), Triazido-trinitrobenzene (TNTAB), Tetranitro-acridone (TENAC), Hexa-nitrodiphenylamine (HEXYL), Nitroguanidine (NQ)] by LC-MS and LC-MSMS with the API-IonSpray source and using the Parent-Scan technique are presented.  相似文献   

18.
19.
The aim of this study was to develop a fast and reliable analytical procedure for the display of the protein components of tears that can be used to differentiate the status of the ocular surface. Using this new procedure, we analyzed the tear protein components following a corneal wound in the rabbit. Calibrated 10-microL glass, fire-polished capillary micropipettes were used to collect tears from New Zealand White rabbits prior to and daily for 9 days following a unilateral 6-mm diameter centrally placed anterior keratectomy. Tear proteins were eluted by a reversed-phase high-performance liquid chromatography (RP-HPLC) column and the tear protein profile was monitored by electrospray ionization (ESI) mass spectrometry positive total ion current (TIC) chromatography. Tear proteins were reliably separated into 17 peaks, each of which contained one or a number of protein components. The molecular weight of each protein component was determined by on-line ESI. Major tear protein components, lactoferrin, lysozyme (minimally detectable in rabbit tears), albumin, lipocalin, lipophilin and beta2-microglobulin, were tentatively identified by this method. Based on the mass spectrometric data, beta2-microglobulin was found to be glycosylated with N-acetylhexosamine. ESI-positive TIC chromatograms and mass spectra revealed comparative differences in the tear protein spectra after corneal wounding. One day after wounding, rabbit lysozyme with a molecular weight of 14,717 Da was found to be 8-fold higher in the tears of wounded eyes when compared with tears from unwounded eyes. It dropped back to normal 3 days after wounding. The expression of an unidentified tear protein with the molecular weight of 16,060 Da was also elevated after corneal wounding and returned to normal level by day 5. In this study, LC/ESI-MS was developed as a fast, reproducible and simple method for the identification and analysis of many of the protein components of the tears. Importantly, this technique also allows quantification of each component resolved in the chromatogram. This method is very suitable for mapping peptides and proteins (<80 kDa) in tears.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号