1.
建立高效液相色谱法测定消毒液和卫生护理用品中的对氯间二甲苯酚方法.采用Hypersil C18 ODS柱分离,流动相为甲醇- 0.5%乙酸水溶液(体积比为60∶40),流速为1.0 mL/min;用二极管阵列检测器,检测波长280nm.对氯间二甲苯酚在10~400 μg/mL范围内与色谱峰面积呈良好的线性关系,相关系数...  相似文献   

2.
建立毛细管气相色谱法测定霉酚酸酯原材料药中5种有机溶剂残留量。采用DB–WAX弹性石英毛细管色谱柱(30 m×0.53 mm,0.5μm),氢火焰离子化检测器(FID),两次程序升温测定,5种有机溶剂能完全分离(R2.0)。乙酸乙酯、乙基苯、对二甲苯、间二甲苯、邻二甲苯的线性范围分别为5.120~512.0,2.010~201.0,2.110~211.0,2.000~200.0,2.080~208.0μg/mL(r0.999),检出限分别为1.710,0.960,1.000,0.95,0.990μg/mL,平均加标回收率为96.0%~103.0%,测定结果的相对标准偏差为0.76%~0.99%(n=9)。该方法准确,灵敏度高,可用于霉酚酸酯原料药中有机溶剂残留检测。  相似文献   

3.
建立同时测定洗涤产品中4-氯-3-甲酚、双氯酚、苄氯酚、邻苯基苯酚、对氯间二甲苯酚、三氯生、三氯卡班7种防腐剂的高效液相色谱分析方法。不同基质的样品经甲醇涡旋混匀及超声提取后,用X–Bridge C18反相色谱柱(250mm×4.6 mm,5μm)进行分离,以甲醇–水为流动相,梯度洗脱,采用二极管阵列检测器(DAD)进行检测,检测波长为285 nm。在优化的实验条件下,7种防腐剂的质量浓度在0.2~500 mg/L范围内与其色谱峰面积呈良好的线性关系,相关系数(r2)均为0.999 9,方法的检出限(S/N=3)为1.0~2.5 mg/kg,定量限(S/N=10)为3.0~7.5 mg/kg。7.5,25.0,75.0 mg/kg 3水平加标回收率为92.1%~105.8%,相对标准偏差为0.8%~4.5%(n=6)。该方法简单、快速、准确,适用于洗涤产品中7种防腐剂的测定。  相似文献   

4.
建立了高温水解–离子色谱法测定八氧化三铀中氟和氯含量的方法。对影响高温水解的因素进行了试验研究,水解温度为1 050℃,水浴温度为(85±1)℃,氩气流量为600 mL/min,水解时间为1 h。选用Ion Pac AG11–HC(50 mm×4 mm)阴离子保护柱和Ion Pac AS11–HC(250 mm×4 mm)阴离子分析柱对样品进行分离,以氢氧化钾溶液等度淋洗。在0~5.00μg/mL范围内,氟和氯均有良好的线性,相关系数(r~2)分别为0.999 9,0.999 4;检出限分别为3,4μg/g。氟和氯测定结果的相对标准偏差分别为4.72%,3.23%(n=6),加标回收率分别为97%~101%,95%~99%。该法操作简便、快速,适用于八氧化三铀中氟和氯的检测。  相似文献   

5.
建立了毛细管气相色谱法测定芳香异羟肟酸二丁基锡中的有机溶剂残留量.采用HP-5 (5%苯基甲基聚硅氧烷)毛细管色谱柱,FID检测器.载气为N2,柱温为45 ℃,检测器温度为160 ℃,流速为1.2 mL/min,分流比为20∶1,四氢呋喃为内标进行测定.结果表明: 甲醇、无水乙醇、三氯甲烷、正己烷、苯的线性范围分别为: 7.9~63.2 μg/mL (r=0.9991),8.69~69.52 μg/mL (r=0.9999),19.77~158.16 μg/mL (r=0.9990),295.6~2364.8 μg/mL (r=0.9996),8.74~69.92 μg/mL (r=0.9996),平均回收率分别为104.2%、 98.8%、 97.9%、 103.1%和102.0%,RSD分别为1.6%、 2.3%、 2.1%、 3.8%和1.9% (n=9);检出限分别为3.16、 3.47、 23.90、 1.97和0.87 ng.方法可用于有机溶剂残留量的测定.  相似文献   

6.
建立高效液相色谱法同时测定三氯异氰脲酸(粉)中三聚氰酸和三聚氰胺含量的方法.采用HILIC Silica色谱柱(150 mm×4.6 mm,5 μm),以乙腈-10 mmol/L乙酸铵水溶液(9∶1)为流动相,用紫外检测器在213 nm波长处进行检测.三聚氰酸和三聚氰胺的浓度分别在9.22~92.2 μg/mL和10.92~109.2 μg/mL范围内与对应的峰面积呈良好的线性关系.三聚氰酸和三聚氰胺测定结果的相对标准偏差分别为0.3%、0.4%(n=6).在80%、100%、120%3个添加水平下三聚氰酸的平均回收率分别为117.41%、119.85%、114.40%.  相似文献   

7.
尹俊发  杨更亮  李志伟  范子琳 《色谱》2003,21(5):494-496
应用反相高效液相色谱-蒸发光散射检测法对安宫牛黄胶囊中的胆酸含量进行了测定。色谱柱用JASCO C18柱(250 mm×4.6 mm i.d.,5 μm),流动相为甲醇-0.1%(体积分数)醋酸水溶液(体积比为9∶1),流速1.0 mL/min,柱温为室温;蒸发光散射检测器漂移管温度40 ℃,载气(N2)流速4.0 L/min。在上述条件下测得胆酸的进样量为0.50-5.02 μg时线性关系良好(r=0.999?3),最低检测限达到0.05 μg,平均加样回收率为97.1%。该方法快速简捷,精密度高,重现  相似文献   

8.
建立同时测定化妆品中9种4-羟基苯甲酸酯类防腐剂的高效液相色谱法。样品经甲醇溶解,超声提取,使用Waters Symmtery C_(18)(2.1 mm×250 mm,5μm)色谱柱,用0.1%磷酸溶液–乙腈为流动相进行梯度洗脱,采用二极管阵列检测器进行检测,检测波长为254 nm,外标法定量。9种防腐剂的质量浓度在0.1~100μg/mL范围内与对应的色谱峰面积线性关系良好,相关系数为0.9993~0.9997,检出限为0.65~2.22μg/g,定量限为2.18~7.39μg/g。样品在25、50、250μg/g 3个加标水平时的平均回收率为95.73~104.06%,测定结果的相对标准偏差为0.58~5.28%(n=6)。该方法简单、准确、灵敏,可用于化妆品中9种4-羟基苯甲酸酯类防腐剂的测定。  相似文献   

9.
高效液相色谱法测定盐酸甲氯芬酯胶囊的含量   总被引:2,自引:0,他引:2  
建立了用高效液相色谱测定盐酸甲氯芬酯胶囊含量的方法.采用Hypersil C18柱(5 μm,4.6 mm i.d.×200 mm),流动相为V(乙腈)∶V(0.12% NH4HCO3-0.50%三乙胺)溶液=33∶67 (甲基磺酸调pH至3.0),流速: 1.0 mL/min,检测波长为225 nm.盐酸甲氯芬酯的线性范围为1.632~163.2 μg/mL,平均回收率为99.67%,RSD=1.8% (n=9).  相似文献   

10.
建立了测定中药复方制剂九味石灰华散中羟基红花黄色素A和红景天苷含量的高效液相色谱方法.采用Kromasil C18色谱柱(5μm,250 mm×4.6 mm),以乙腈∶0.1%磷酸溶液(12∶88,V/V)为流动相,流速1.0 mL/min,羟基红花黄色素A的检测波长为403 nm,红景天苷的检测波长为275 nm.羟基红花黄色素A和红景天苷分别在0.288~180μg/mL和4.8~1 200μg/mL范围内呈良好的线性关系(r值为0.999 8~0.999 9),最低检出限分别为0.03μg/mL和0.5μg/mL(S/N=3),加标回收率分别为95.7%~97.4%和95.9%~98.6%.该方法简便、准确、重现性好,可用于九味石灰华散的质量控制.  相似文献   

11.
高效液相色谱–光电二极管阵列法测定虾青素的含量   总被引:1,自引:0,他引:1  
建立虾青素含量测定的高效液相色谱–光电二极管阵列法。采用Purospher STAR RP 18(4.6 mm×250mm,5μm)色谱柱,以甲醇–水(体积比为95∶5)为流动相,流速1.0 mL/min,检测波长为482 nm,柱温为30℃,进样量为20μL。在所选定的液相色谱条件下,虾青素主峰与其它杂质峰分离良好,虾青素在0.2~16μg/mL范围内线性良好,线性相关系数r=0.999 9,检出限为0.01μg/mL,测定结果的相对标准偏差为0.42%(n=6),平均回收率为100.4%。该法分析快速准确、灵敏度高、重现性好。  相似文献   

12.
利用水杨酸、阿司匹林、乙酸酐和乙酸的多波长紫外光谱作为本底光谱库和样本光谱库,建立一种基于子空间夹角判据的快速定量分析阿司匹林合成体系中水杨酸和阿司匹林的方法。水杨酸、阿司匹林质量浓度范围分别在1.16~34.684,9.84~188.928μg/mL内,所测得水杨酸和阿司匹林检验集的R分别为0.999 7和0.999 1,RMSE分别为0.509 5,2.624 0μg/mL,效果优于普通波峰点最小二乘法和偏最小二乘法。水杨酸和阿司匹林的加标回收率在94.01%~106.44%之间,测定结果的相对标准偏差分别为3.45%和4.80%(n=7)。该方法可用于监测阿司匹林合成体系中的水杨酸和阿司匹林。  相似文献   

13.
建立超高效液相色谱法快速检测虾青素的方法。采用UPLC BEH C_8色谱柱(50 mm×2.1 mm,1.7μm),考察了流动相、流量及柱温对虾青素样品分离的影响,确定了最佳色谱条件:等度洗脱,流动相为甲醇–水(体积比为75∶25),流量为0.5 mL/min,柱温为40℃,检测波长为475 nm。虾青素的质量浓度在0.2~10.0μg/mL范围内与其色谱峰面积呈良好的线性关系,线性相关系数r=0.998 8,检出限(S/N=3)为0.1μg/mL,定量限(S/N=10)为0.2μg/mL。测定结果的相对标准偏差为0.41%(n=6),加标回收率为105.8%~110.3%。该方法快速、简单、可靠、灵敏、重复性好,可用于虾青素有关样品的快速检测。  相似文献   

14.
Attention has shifted from the treatment of colorectal cancer (CRC) to chemoprevention using aspirin and folic acid as agents capable of preventing the onset of colon cancer. However, no sensitive analytical method exists to simultaneously quantify the two drugs when released from polymer‐based nanoparticles. Thus, a rapid, highly sensitive method of high‐performance liquid chromatography analysis to simultaneously detect low quantities of aspirin (hydrolyzed to salicylic acid, the active moiety) and folic acid released from biodegradable polylactide‐co‐glycolide (PLGA) copolymer nanoparticles was developed. Analysis was done on a reversed‐phase C18 column using a photodiode array detector at wavelengths of 233 nm (salicylic acid) and 277 nm (folic acid). The mobile phase consisted of acetonitrile–0.1% trifluoroacetic acid mixture programmed for a 30 min gradient elution analysis. In the range of 0.1–100 μg/mL, the assay showed good linearity for salicylic acid (R2 = 0.9996) and folic acid (R2 = 0.9998). The method demonstrated good reproducibility, intra‐ and inter‐day precision and accuracy (99.67, 100.1%) and low values of detection (0.03, 0.01 μg/mL) and quantitation (0.1 and 0.05 μg/mL) for salicylic acid and folic acid, respectively. The suitability of the method was demonstrated by simultaneously determining salicylic acid and folic acid released from PLGA nanoparticles. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

15.
采用超声提取法提取酱腌菜中的对羟基苯甲酸甲酯、对羟基苯甲酸乙酯及对羟基苯甲酸丙酯,在SE30毛细管柱(33 m×0.53 mm,2.65μm)上得到了良好分离。对羟基苯甲酸甲酯、对羟基苯甲酸乙酯及对羟基苯甲酸丙酯在0~750μg/mL浓度范围内与色谱峰面积呈良好的线性关系,相关系数为0.9999。对羟基苯甲酸甲酯、对羟基苯甲酸乙酯、对羟基苯甲酸丙酯的检出限分别为0.1,0.1,0.2μg/mL,测定结果的相对标准偏差小于3.6%(n=11),平均回收率为84.5%~97.1%。  相似文献   

16.
利用高效液相色谱-二极管阵列检测器(HPLC-DAD),建立了同时分析烟草中新绿原酸、绿原酸、隐绿原酸、东莨菪苷、咖啡酸、七叶亭、对香豆酸、阿魏酸、莨菪亭、7-羟基香豆素、芦丁、槲皮苷、山奈酚-3-O-芸香糖苷和槲皮素14种多酚化合物的方法。称取0.02 g烟末,加入5 mL 50%甲醇,超声萃取30 min,取上清液过水相滤膜后,采用Agilent SB-C18柱(3.0 mm×150 mm,1.8μm)进行分离,以0.05 mol/L磷酸二氢钾水溶液和甲醇为流动相,采用分段式检测,获得14种多酚类化合物在各自最佳检测波长下的信号,实现了良好分离。结果表明,14种多酚类化合物的色谱峰面积与其质量浓度呈良好的线性关系,相关系数r2>0.9997,检出限为0.01~0.15μg/mL,定量下限为0.03~0.50μg/mL,日内相对标准偏差(RSD)为0.70%~3.6%,日间RSD为4.0%~6.4%,加标回收率为95.2%~109%。该方法具有良好的灵敏度、精密度和回收率,适合于烟草样品中多种多酚类化合物的同时测定。  相似文献   

17.
A simple and sensitive stability-indicating chiral HPLC method has been developed and validated per International Conference on Harmonization guidelines for the determination of enantiomeric purity of eluxadoline (Exdl). The impact of different mobile phase compositions and chiral stationary phases on the separation of Exdl enantiomer along with process- and degradation-related impurities has been studied. Homogeneity of Exdl and stable results of Exdl enantiomer in all degraded samples reveal the fact that the proposed method was specific (stability indicating). Amylose tris(3,5-dichlorophenyl carbamate) stationary phase column Chiralpak IE-3 (150 × 4.6 mm, 3 μm) provided better resolution with polar organic solvents than cellulose derivative, crown ether, and zwitterion stationary phases and nonpolar solvents. The mobile phase consisted of acetonitrile, tetrahydrofuran, methanol, butylamine, and acetic acid in the ratio of 500:500:20:2:1.5 (v/v/v/v/v). Isocratic elution was performed at a flow rate of 1.0 mL/min, column temperature of 35°C, injection volume of 10 μL, and UV detection of 240 nm. The United States Pharmacopeia (USP) resolution of the Exdl enantiomer was found to be more than 4.0 within a 65-min run time. Exdl enantiomer detector response linearity over the concentration range of 0.859–4.524 μg/mL was found to be R2 = 0.9985. The limit of detection, limit of quantification, and average percentage recovery values were established as 0.283 μg/mL, 0.859 μg/mL, and 96.0, respectively.  相似文献   

18.
建立了超高效液相色谱–串联质谱(UPLC–MS/MS)法测定果蔬中吡氟甲禾灵残留的方法。样品以乙腈匀浆提取,并采用Sep-Pak Vac型氨基固相萃取柱净化样品,采用超高效液相色谱柱WATERS ACQUITY C_(18)柱(50mm×2.1 mm,1.7μm)分离,以乙腈–0.1%甲酸水溶液作为淋洗液进行梯度洗脱。吡氟甲禾灵在1.0~50.0 ng/m L范围内线性关系良好,相关系数r~2=0.997 7,加标回收率为84.1%~88.6%,测定结果的相对标准偏差为1.18%~3.58%(n=6)。该方法操作简便,分析快速,提取效率高,重现性好,有实用价值。  相似文献   

19.
建立高效液相色谱测定葛根芩连片中葛根素含量的方法。以体积分数50%的甲醇为提取液对样品超声提取20 min,采用DiamonsilTMC18(250 mm×4.6 mm,5μm)色谱柱,以甲醇–乙腈–水(体积比8∶12∶80)为流动相,流速为1.0 mL/min,检测波长为250 nm,柱温为30.0℃,进样量体积10μL。在最佳实验条件下,葛根素与其它物质能完全分离,葛根素的质量浓度在5.43~543.2μg/mL范围内与色谱峰面积呈良好的线性,线性相关系数r=0.999 9,方法检出限为3.50μg/mL(S/N=3)。方法加标回收率为100.0%,测定结果的相对标准偏差为1.6%(n=6)。该方法简单、快速、重现性好,适用于葛根芩连片中葛根素的测定。  相似文献   