首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An original electrochemical sensor based on molecularly imprinted conducting polymer (MICP) is developed, which enables the recognition of a small pesticide target molecule, atrazine. The conjugated MICP, poly(3,4-ethylenedioxythiophene-co-thiophene-acetic acid), has been electrochemically synthesized onto a platinum electrode following two steps: (i) polymerization of comonomers in the presence of atrazine, already associated to the acetic acid substituent through hydrogen bonding, and (ii) removal of atrazine from the resulting polymer, which leaves the acetic acid substituents open for association with atrazine. The obtained sensing MICP is highly specific towards newly added atrazine and the recognition can be quantitatively analyzed by the variation of the cyclic voltammogram of MICP. The developed sensor shows remarkable properties: selectivity towards triazinic family, large range of detection (10−9 mol L−1 to 1.5 × 10−2 mol L−1 in atrazine) and low detection threshold (10−7 mol L−1).  相似文献   

2.
An eight channel molecularly imprinted polymer sensor array was prepared that was able to differentiate six different aryl amine analytes, including diastereomers with 94% accuracy.  相似文献   

3.
Wu B  Wang Z  Xue Z  Zhou X  Du J  Liu X  Lu X 《The Analyst》2012,137(16):3644-3652
Based on Ru(bpy)(3)(2+)-Au nanoparticles decorated multi-walled carbon nanotubes composites and a molecularly imprinted polymer (MIP), we propose a novel molecularly imprinted electrochemiluminescence (ECL) sensor to selectively determine isoniazid (INH). The MIP is synthesized through electrochemical copolymerization of acrylamide and N,N'-methylene diacrylamide in the presence of INH template molecules. The enhanced ECL intensity is linear in the range of 0.1 to 110 μg cm(-3) and the detection limit is 0.08 μg cm(-3) (3σ) INH with relative standard deviation 3.8% (n = 6) for 8 μg cm(-3). As a result, the sensor has been successfully applied to the determination of INH in human urine and pharmaceutical samples. Moreover, the possible ECL mechanism is discussed.  相似文献   

4.
Tan Y  Nie L  Yao S 《The Analyst》2001,126(5):664-668
A molecularly imprinted polymer for aminopyrine was synthesized using methacrylic acid as functional monomer. The polymer was employed as the recognition element of a piezoelectric bulk acoustic wave biomimetic sensor for aminopyrine. Influencing factors were investigated in detail and optimized. This sensor exhibited high selectivity and sensitivity to aminopyrine. The response range of the sensor was between 5.0 x 10(-8) and 1.0 x 10(-4) M with a detection limit of 2.5 x 10(-8) M in the aqueous system. Scatchard analysis with UV spectrophotometry showed that the same class of binding sites was formed in the molecularly imprinted polymer in the studied concentration range, and the dissociation constant and the apparent maximum number of these binding sites were estimated to be 2.29 mM and 165.0 mumol g-1 dry polymer, respectively. Impedance analysis was employed to verify the imprinting effect and lack of variation in the viscoelasticity of the polymer coating during detection.  相似文献   

5.
6.
A new molecularly imprinted electrochemiluminescence (ECL) sensor was proposed for highly sensitive and selective determination of ultratrace Be2+ determination. The complex of Be2+ with 4-(2-pyridylazo)-resorcinol (PAR) was chosen as the template molecule for the molecularly imprinted polymer (MIP). In this assay, the complex molecule could be eluted from the MIP, and the cavities formed could then selectively recognize the complex molecules. The cavities formed could also work as the tunnel for the transfer of probe molecules to produce sound responsive signal. The determination was based on the intensity of the signal, which was proportional to the concentrations of the complex molecule in the sample solution, and the Be2+ concentration could then be determined indirectly. The results showed that in the range of 7 × 10−11 mol L−1 to 8.0 × 10−9 mol L−1, the ECL intensity had a linear relationship with the Be2+ concentrations, with the limit of detection of 2.35 × 10−11 mol L−1. This method was successfully used to detect Be2+ in real water samples.  相似文献   

7.
A fiber-optic evanescent wave sensor for bisphenol A (BPA) determination based on a molecularly imprinted polymer (MIP)-modified fiber column was developed. MIP film immobilized with BPA was synthesized on the fiber column, and the sensor was then constructed by inserting the optical fiber prepared into a transparent capillary. A microchannel (about 2.0 μL) formed between the fiber and the capillary acted as a flow cell. BPA can be selectively adsorbed online by the MIP film and excited to produce fluorescence by the evanescent wave produced on the fiber core surface. The conditions for BPA enrichment, elution, and fluorescence detection are discussed in detail. The analytical measurements were made at 276 nm/306 nm (λ ex/λ em), and linearity of 3?×?10?9–5?×?10?6 g mL?1 BPA, a limit of detection of 1.7?×?10?9 g mL?1 BPA (3σ), and a relative standard deviation of 2.4 % (n?=?5) were obtained. The sensor selectivity and MIP binding measurement were also evaluated. The results indicated that the selectivity and sensitivity of the proposed fiber-optic sensor could be greatly improved by using MIP as a recognition and enrichment element. Further, by modification of the sensing and detection elements on the optical fiber, the proposed sensor showed the advantages of easy fabrication and low cost. The novel sensor configuration provided a platform for monitoring other species by simply changing the light source and sensing elements. The sensor presented has been successfully applied to determine BPA released from plastic products treated at different temperatures.
Figure
EW eixcation of BPA immobilized in MIP on the fiber core surface  相似文献   

8.
A novel amperometric sensor based on electropolymerized molecularly imprinted polymer (MIP) for triclosan detection is reported. The sensor was prepared by electropolymerizing o-phenylenediamine (o-PD) on a glassy carbon electrode in the presence of template triclosan. The template can be quickly removed by NaOH solution. After incubating in acetate buffer for 15 min, the sensor response sensitively to triclosan over a linear range of 2.0 × 10− 7 to 3.0 × 10− 6 mol/L and a detection limit as low as 8.0 × 10− 8 mol/L is obtained. This sensor provides an efficient way for eliminating interferences from compounds with similar structures to that of triclosan.  相似文献   

9.
以丙烯酰胺为功能性单体,N,N'-亚甲基双丙烯酰胺为交联剂,次黄嘌呤为模板分子,在pH 13.5的强碱性溶液中采用循环伏安法合成了聚丙烯酰胺膜,以此为识别元件制备了次黄嘌呤电容型生物传感器,并用电化学阻抗技术表征了电聚合分子印迹膜的性能.在 2~15μmol/L 的范围之内,次黄嘌呤浓度的变化与电容的变化成线性关系.每次加入次黄嘌呤后响应约在 5min 后达到稳定,传感器制备容易,检测快速.与传统的聚丙烯酰胺膜不同,该膜在碱性溶液中制备,稳定性好,不易溶胀.  相似文献   

10.
A novel potentiometric sensor based on molecularly imprinted polymer (MIP) for propranolol, an adrenergic-blocking drug, was designed. The influence of molecularly imprinted polymer particle content and sodium tetraphenylborate additives in polyvinylchloride membrane was shown. The electrodes show near-Nernstian responses down to 10?4–10?5?M propranolol concentration. The potentiometric response of MIP-based sensor for propranolol in mixed nonaqueous medium was shown at first. Sensor selectivity relative to various inorganic cations, atenolol and metoprolol, was reported. Direct potentiometry was used to determine propranolol in aqueous modeling solutions and pharmaceutical preparations with good results.  相似文献   

11.
Wang LQ  Lin FY  Yu LP 《The Analyst》2012,137(15):3502-3509
A molecularly imprinted photonic polymer (MIPP) sensor for respective detection of tetracycline, oxytetracycline and chlortetracycline is developed based on the combination of a colloidal crystal templating method and a molecular imprinting technique. Colloidal crystal templates are prepared from monodisperse polystyrene colloids. The molecularly imprinted polymer, which is embodied in the colloidal crystal templates, is synthesized with acrylic acid and acrylamide as monomers, N,N'-methylene bisacrylamide as a cross-linker and tetracyclines (TCs) as imprinting template molecules. After removal of the colloidal crystal template and the molecularly imprinted template, the resulted MIPP consists of a three-dimensional, highly ordered and interconnected macroporous array with a thin hydrogel wall, where nanocavities complementary to analytes in shape and binding sites are distributed. The response of MIPP to TCs stimulants in aqueous solution is detected through a readable Bragg diffraction red-shift, which is due to the lattice change of MIPP structures responding to their rebinding to the target TCs molecules. A linear relationship was found between the Δλ and the concentration of TCs in the range from 0.04 μM to 0.24 μM. With this sensory system, direct and selective detection of TCs has been achieved without using label techniques and expensive instruments. The developed method has been applied successfully to detect tetracycline in milk and honey samples.  相似文献   

12.
A novel molecularly imprinted sensor was fabricated and used for the impedimetric detection of melamine. Considering the identity of polymeric film and the pK a of a melamine template, an effective procedure was established to construct the MIP-based melamine sensor. The proposed method is based on the electropolymerization of pyrrole (Py) in the presence of melamine on the electrochemically reduced graphene oxide modified glassy carbon electrode (ERGO/GCE), followed by treatment with the solution of 1% H2O2 in alkaline water/CH3CN-mixed solvents. The surface morphology and the electrical feature of molecularly imprinted polymer (MIP) were characterized by scanning electron microscopy (SEM), Fourier transformation infrared spectroscopy (FTIR), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). The EIS was also utilized to transduce the change of charge transfer resistance (R ct) at the interface of polymer film-electrolyte, after subsequent incubation of electrode in the solution containing different concentrations of analyte, and consequently, a linear response was obtained over the range of 4.0 to 240 nM with a detection limit of 0.83 nM (S/N = 3). The effect of possible interferences on the response of sensor was studied, and the results confirmed the good selectivity of the proposed device for melamine assay. The MIP sensor was successfully applied to determine melamine in a multiple concentration-spiked milk sample.  相似文献   

13.
A colorimetric sensor array composed of seven molecularly imprinted polymers was shown to accurately identify seven different aromatic amines. The response patterns were systematically classified using linear discriminant analysis with 94% classification accuracy. Analyses of the response patterns of the analytes to the imprinted polymer array suggest that the different selectivity patterns, although subtle, appear to arise from the imprinting process. The molecular imprinting process enabled the rapid preparation of the polymers in the array from ethylene glycol dimethacrylate and methacrylic acid (80:20) in the presence of six different template molecules plus a blank nonimprinted polymer. The response of the imprinted polymer array was coupled to a colorimetric response, using a dye displacement strategy. A benzofurazan dye was selected and shown to give an accurate measure of the binding properties of the imprinted polymer array to all seven analytes. The colorimetric response also enabled the inclusion of analytes that are not spectroscopically active and were not among the original analytes that were used as template molecules. This broadens the potential utility of the imprinted polymer sensor array strategy to a wider range of analytes and applications.  相似文献   

14.
This work reports on the development of a new voltammetric sensor for diphenylamine based on the use of a miniaturized gold electrode modified with a molecularly imprinted polymer recognition element. Molecularly imprinted particles were synthesized ex situ and further entrapped into a poly(3,4-ethylenedioxythiophene) polymer membrane, which was electropolymerized on the surface of the gold electrode. The thickness of the polymer layer was optimized in order to get an adequate diffusion of the target analyte and in turn to achieve an adequate charge transfer at the electrode surface. The resulting modified electrodes showed a selective response to diphenylamine and a high sensitivity compared with the bare gold electrode and the electrode modified with poly(3,4-ethylenedioxythiophene) and non-imprinted polymer particles. The sensor showed a linear range from 4.95 to 115 μM diphenylamine, a limit of detection of 3.9 μM and a good selectivity in the presence of other structurally related molecules. This sensor was successfully applied to the quantification of diphenylamine in spiked apple juice samples.  相似文献   

15.
Gao N  Dong J  Liu M  Ning B  Cheng C  Guo C  Zhou C  Peng Y  Bai J  Gao Z 《The Analyst》2012,137(5):1252-1258
A quartz crystal microbalance (QCM) sensor based on molecularly imprinted ultra-thin films was developed for detecting profenofos in real samples. Films prepared by physical entrapment (MIP-A) and in situ self-assembly (MIP-B) were compared. The results indicated that the best sensing signal was obtained through the in situ self-assembly method. The QCM sensor chip was pretreated with 11-mercaptoundecanoic acid (MUA) to form a self-assembled monolayer (SAM), and then polymer films were immobilized directly on the SAM using surface-initiated radical polymerization. In this paper, all detection experiments were taken in air. The reaction was processed in solution, and the electrode was washed with deionized water and dried with N(2) before QCM measurement. The film was characterized by a scanning electron microscope (SEM), AC impedance and cyclic voltammetry. Analysis of the QCM response in the presence of different concentrations of profenofos showed a good linear correlation during 1.0 × 10(-8) to 1.0 × 10(-5) mg mL(-1) (y = 5log x + 42.5, R = 0.9960) and 1.0 × 10(-5) to 1.0 × 10(-3) mg mL(-1) (y = 25.86log x + 146, R = 0.9959), respectively. The MIP-QCM sensor was used to detect profenofos in tap water, and showed good recovery and repeatability.  相似文献   

16.
合成了甲福明的分子印迹聚合物,以此聚合物为识别物质,在线分离富集甲福明,建立了一种测定甲福明的流动式化学发光但感器。N-溴代丁二酰亚胺(NBS)和荧光素与甲福明发生化学反应,产生强的化学发光。甲福明质量浓度在2×10-8~8×10-6g/mL范围内同发光强度成良好线性关系,方法的检出限为6×10-9g/mL,相对标准偏差小于5%(n=9)。选择性实验表明将分子印迹聚合物作为识别物质应用于化学发光分析中,能大大提高化学发光分析方法的选择性。该传感器可逆性强、稳定性好,可重复使用100次以上,已用于人体尿样中甲福明的测定。  相似文献   

17.
In this work an aptamer-based biosensor is combined with a multisine electrochemical impedance spectroscopy sensing methodology into a novel and promising biosensing strategy. Employing a multisine instead of a traditional single sine measuring method allows the detection and quantification of parameters that provide information about the accuracy and reliability of the results, such as noise and distortions. This does not only lead to a shorter measurement time, but it also enables an easy and fast evaluation of the quality of the data and fitting, leading to more accurate results.  相似文献   

18.
Molecular imprinted polymer coated QCM for the detection of nandrolone   总被引:3,自引:0,他引:3  
An acoustic wave sensor coated with an artificial biomimetic recognition element has been developed to selectively screen for nandrolone in the liquid phase. A highly specific covalently imprinted polymer (MIP) was spin coated onto one electrode of a quartz crystal microbalance (QCM) as a thin permeable film. Selective rebinding of the nandrolone was observed as a frequency shift in the QCM for concentrations up to 0.2 ppm with the sensor binding shown to favour nandrolone over analogous compounds.  相似文献   

19.
Polyaniline nanotubes (PANI-NT) based film electrophoretically deposited onto indium–tin–oxide (ITO) coated glass plate has been utilized for covalent immobilization of lipase (LIP), via glutaraldehyde (Glu), for triglyceride detection using impedimetric technique. It is shown that fatty acid molecules produced during triglyceride hydrolysis result in change in charge transfer resistance (RCT) of PANI-NT film with varying triglyceride concentration. LIP/Glu/PANI-NT/ITO bioelectrode has linearity as 25–300 mg dL?1, sensitivity as 2.59 × 10?3 ?1 mg?1 dL, response time as 20 s and regression coefficient as 0.99. A low value of apparent Michaelis–Menten constant (~0.62 mM) indicates high enzyme affinity to tributyrin. The LIP/Glu/PANI-NT/ITO bioelectrode has been utilized to estimate triglyceride in serum samples.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号