首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A non-optical shear-force-based detection scheme for accurately controlling the tip-to-sample distance in scanning electrochemical microscopy (SECM) is presented. With this approach, the detection of the shear force is accomplished by mechanically attaching a set of two piezoelectric plates to the scanning probe. One of the plates is used to excite the SECM tip causing it to resonate, and the other acts as a piezoelectric detector of the amplitude of the tip oscillation. Increasing shear forces in close proximity to the sample surface lead to a damping of the vibration amplitude and a phase shift, effects that are registered by connecting the detecting piezoelectric plate to a dual-phase analogue lock-in amplifier. The shear force and hence distance-dependent signal of the lock-in amplifier is used to establish an efficient, computer-controlled closed feedback loop enabling SECM imaging in a constant-distance mode of operation. The details of the SECM setup with an integrated piezoelectric shear-force distance control are described, and approach curves are shown. The performance of the constant-distance mode SECM with a non-optical detection of shear forces is illustrated by imaging simultaneously the topography and conductivity of an array of Pt-band microelectrodes.  相似文献   

2.
Scanning electrochemical microscopy (SECM) still lacks reliable means for performing constant-distance imaging experiments. We demonstrate, for the first time, that the same negative alternating current (AC) feedback can be observed on approach to an insulator and an unbiased conductor at optimal experimental conditions. This leads to a novel constant-distance imaging mode. To perform AC-SECM imaging, only minor modifications of the existing SECM set-up were necessary. The new constant-distance AC-SECM imaging was conducted to provide topographical information not affected by variations in sample conductivity and reactivity. Furthermore, simultaneous AC and DC SECM measurements were carried out to demonstrate that both topographical and chemical information could be revealed.  相似文献   

3.
Eckhard K  Schuhmann W 《The Analyst》2008,133(11):1486-1497
Alternating current scanning electrochemical microscopy (AC-SECM) is a growing branch within the variety of SECM methods. This review covers publications involving AC-SECM from its beginning to date. The findings of several research groups are thematically structured along with the specific experimental procedures. This should enable researchers to rationally choose purposeful parameters for their AC-SECM experiments.  相似文献   

4.
We developed a high-resolution scanning electrochemical microscope (SECM) for the characterization of various biological materials. Electrode probes were fabricated by Ti/Pt sputtering followed by parylene C-vapor deposition polymerization on the pulled optical fiber or glass capillary. The effective electrode radius estimated from the cyclic voltammogram of ferrocyanide was found to be 35 nm. The optical aperture size was less than 170 nm, which was confirmed from the cross section of the near-field scanning optical microscope (NSOM) image of the quantum dot (QD) particles with diameters in the range of 10-15 nm. The feedback mechanism controlling the probe-sample distance was improved by vertically moving the probe by 0.1-3 microm to reduce the damage to the samples. This feedback mode, defined as "standing approach (STA) mode" (Yamada, H.; Fukumoto, H.; Yokoyama, T.; Koike, T. Anal. Chem. 2005, 77, 1785-1790), has allowed the simultaneous electrochemical and topographic imaging of the axons and cell body of a single PC12 cell under physiological conditions for the first time. STA-mode feedback imaging functions better than tip-sample regulation by the conventionally available AFM. For example, polystyrene beads (diameter approximately 6 microm) was imaged using the STA-mode SECM, whereas imaging was not possible using a conventional AFM instrument.  相似文献   

5.
Single-cell analysis is important for understanding fundamental biological processes and mechanisms. Scanning electrochemical microscopy and scanning ion conductance microscopy as two kinds of scanning probe microscopy, with high temporal and spatial resolutions as well as in situ and noninvasive characterization capabilities, emerge as strong tools for single-cell analysis. In this review, we introduce the latest advances of scanning electrochemical microscopy and scanning ion conductance microscopy for single-cell analysis, including characterizations of cell morphology dynamics, membrane properties and mechanics, and monitoring cell surface charge, extracellular pH, and intracellular substances.  相似文献   

6.
A new method for measuring local interfacial impedance properties with high lateral resolution was developed by combination of electrochemical impedance spectroscopy (EIS) with scanning electrochemical microscopy (SECM). Alternating current scanning electrochemical microscopy (AC-SECM) allowed to identify and visualise microscopic domains of different conductivity/electrochemical activities on solid/liquid interfaces immersed into an electrolyte. The performance of the method was illustrated by imaging an array of Pt-band microelectrodes in solutions of low conductivity in the absence of any redox mediator.  相似文献   

7.
In this paper we present the application of alternating current scanning electrochemical microscopy (AC-SECM) to the study of living cells. Commercial AFM instrumentation was modified to allow for performing robust AC-SECM measurements. Constant height AC imaging of the Cos-7 cells, performed directly in cell culture medium without the addition of a redox mediator, provided topographical information of the cell. Stationary tip measurements on the AC current were carried out to investigate the cellular activity of a single cell. The dependence of AC current magnitude on tip-to-sample separation distance was used to monitor real time changes in cell height of individual Cos-7 cells. Furthermore, AC-SECM was employed to observe changes in metabolic cellular activity stimulated by ethanol and phorbol-1,2-myristate-acetate-3. The effect of changing cellular activity on constant height AC-SECM imaging was also studied.  相似文献   

8.
An efficient strategy for visualizing human fingerprints on a poly(vinylidene difluoride) membrane (PVDF) by scanning electrochemical microscopy (SECM) has been developed. Compared to a classical ink fingerprint image, here the ink is replaced by an aqueous solution of bovine serum albumin (BSA). After placing the “inked” finger on a PVDF membrane, the latent image is stained by silver nitrate and the fingerprint is imaged electrochemically using potassium hexachloroiridate (III) (K3IrCl6) as a redox mediator. SECM images with an area of 5 mm × 3 mm have been recorded with a high-resolution using a 25-μm-diameter Pt disk-shaped microelectrode. Pores in the skin (40–120 μm in diameter) and relative locations of ridges were clearly observed. The factors relevant to the quality of fingerprint images are discussed.  相似文献   

9.
Different gold surfaces modified by carbon-spray have been investigated by scanning electron microscopy (SEM) and scanning electrochemical microscopy (SECM). A transformation of the SECM image to a distance-location profile is proposed which assists the correlation of both images. The structures found in the transformed SECM images of carbon-spray layers on gold substrates can be explained by the topographic features visible in the SEM pictures. Tempering the carbon spray results in an increased density of electrochemically reactive carbon particles which could be confirmed by cyclic voltammetric investigations. Gold minigrids modified with carbon spray expose some areas of especially large currents which could not be predicted from their SEM images. This effect may result from particles located at the edge of a wire intersection having relatively large active surfaces per particle. They contribute significantly to the total current of the minigrid.  相似文献   

10.
In this work, we present and discuss the use of cavity-microelectrodes (C-MEs) used as tip for the scanning electrochemical microscopy (SECM). Cavity-microelectrodes can be filled with a desired finely dispersed material thus compensating for the limited commercial availability of microwires. After discussing the possibility of filling and emptying a cavity-microelectrode with a desired tip shape, the consistency of negative and positive feedback approach curves obtained after filling a Au C-ME was verified. In addition, the tip/C-ME was tested under gas (oxygen) evolution condition, in order to demonstrate that the filling is stable in a wide range of gas fluxes thus extending the possible applications to tip generation/substrate collection mode. Finally, we introduce the use of the proposed system to quantify the rates of parallel reactions occurring at the material inserted in the tip under the tip generation/substrate collection mode.  相似文献   

11.
Scanning electrochemical microscopy (SECM) and scanning chemiluminescence microscopy (SCLM) were used for imaging an enzyme chip with spatially-addressed spots for glucose oxidase (GOD) and uricase microspots. For the SECM imaging, hydrogen peroxide generated from the GOD and/or uricase spots was directly oxidized at the tip microelectrode in a solution containing glucose and/or uric acid (electrochemical (EC) detection). For the SCLM imaging, a tapered glass capillary (i.d. of 1∼2 μm) filled with luminol and horseradish peroxidase (HRP) was used as the scanning probe for generating the chemiluminescence (CL). The inner solution was injected from the capillary tip at 78 pl s−1 while scanning above the enzyme-immobilized chip. The CL generated when the capillary tip was scanned above the enzyme spots was detected using a photon-counter (CL detection). Two-dimensional mapping of the oxidation current and photon-counting intensity against the tip position affords images of which their contrast reflects the activity of the immobilized GOD and uricase. For both the EC and CL detections, the signal responses were plotted as a function of the glucose and uric acid concentrations in solution. The sensitivities for the EC and CL detection were found to be comparable.  相似文献   

12.
The quest for higher spatial resolution in scanning electrochemical microscopy (SECM) calls for the application of smaller probe electrodes. When electrodes are to be used in the feedback mode, smaller electrodes require higher intrinsic kinetics at the sample. The fabrication of nanoelectrodes, as well as their use as SECM probes at constant distance, are reported. The properties of shear force regulation system are characterized quantitatively. Simultaneous topography and reactivity imaging were demonstrated using gold microstructures on a glass substrate.  相似文献   

13.
We report a new method for detection and oxidation of adsorbed carbon monoxide(CO(ads)) generated from serine on a polycrystalline platinum ultramicroelectrode(UME) by bromine(Br2) using in situ surface interrogation(SI) mode of scanning electrochemical microscopy(SECM).In the SI mode,tip and substrate are both Pt UMEs,and CO(ads) on Pt substrate,generated from serine,can be oxidized by the tip-generated Br2 giving a positive response.Dosing CO(ads) from serine instead of purging CO gas expands the newly introduced reaction of Br2 with CO(ads) and further enhances the hope to get rid of CO(ads) on Pt for fuel cells.  相似文献   

14.
Micro- and nanoscale surface modification using scanning probe microscopy techniques in combination with electrochemically induced surface structuring provides a maskless in situ fabrication strategy enabling deposition or etching of three-dimensional nanostructures. This current opinion article focuses on scanning electrochemical probe microscopy techniques highlighting recent progress in nanoscale 3D surface modification along with a spotlight on approaches of practical relevance.  相似文献   

15.
We report the first directed adsorption of Photosystem I (PSI) on patterned surfaces containing discrete regions of methyl- and hydroxyl-terminated self-assembled monolayers (SAMs) on gold. SAM and PSI patterns are characterized by scanning electrochemical microscopy (SECM). The insulating protein complex layer blocks the electron transfer of the SECM mediator, thereby reducing the electrochemical current significantly. Uniformly and densely packed adsorbed protein layers are observed with SECM. Pattern images correlate with our previous studies where we showed that low-energy surfaces (e.g., CH3-terminated) inhibit PSI adsorption in the presence of Triton X-100, whereas high-energy surfaces (e.g., OH-terminated) enable adsorption. Therefore, a SAM pattern with alternating methyl and hydroxyl surface regions allows PSI adsorption only on the hydroxyl surface, and this is demonstrated in the resulting SECM images.  相似文献   

16.
We report a scanning electrochemical microscopy (SECM)-based receptor-mediated endocytosis detection method. Epidermal growth factor receptor (EGFR), which is one of the key membrane proteins associated with cancer, was used as a model for receptor-mediated endocytosis. EGFR molecules on the outer cell membrane were detected by SECM by using alkaline phosphatase (ALP) as a labeling enzyme. Since SECM detected the ALP activity on the outer membrane, the procedure helped discriminate the EGFR on the outer membrane from the intracellular EGFR involved in endocytosis. SECM showed a marked decrease in the current responses generated due to ALP activity by 93% on addition of the epidermal growth factor, indicating clearly that EGF triggered the endocytosis, which led to the withdrawal of most EGFRs from the outer membrane.  相似文献   

17.
研究病变细胞和组织的异常表现可为理解重大疾病发生发展的病理机理和新型药物筛选提供重要参考.扫描电化学显微镜(Scanning electrochemical microscopy, SECM)是一种基于电化学原理的扫描探针显微镜,通过记录探针在样品表面扫描时的电流或电位等信息,对活细胞的形态和多种化学信息进行原位、实时...  相似文献   

18.
AFM-SECM measurements using alternating current mode SECM (AC–SECM) were performed at an AFM tip with an integrated recessed ring microelectrode. Measurements were carried out in a three-electrode arrangement at 14.92 kHz and 110 mVpp in 1 mM KCl solution. Combined AFM–AC–SECM enables the detection of electrochemical surface properties with high lateral resolution without addition of a redox mediator, thereby providing images on topographical changes along with chemical information. For demonstrating the capabilities of this method, simultaneously recorded data on the topography and the surface conductivity of gold/glass structures and of microelectrode arrays are discussed.  相似文献   

19.
Scanning electrochemical microscopy and scanning electron microscopy were employed to correlate the surface microstructures with surface reactivity of commercially pure zirconium. It was found that heightened reactivity was associated with iron impurities lying beneath the oxide surface. This could result in failure of nuclear reactor components fabricated using zirconium alloys due to hydrogen ingress and corrosion. COMSOL multiphysics software was used to quantify the electrochemical kinetic constants associated with the differences in surface reactivity.  相似文献   

20.
In scanning electrochemical microscopy (SECM) a microelectrode is usually scanned over a sample without following topographic changes (constant-height mode). Therefore, deconvolution of effects from distance variations arising from non-flat sample surface and electrochemical surface properties is in general not possible. Using a shear force-based constant distance mode, information about the morphology of a sample and its localized electrochemical activity can be obtained simultaneously. The setup of the SECM with integrated constant-distance mode and its application to non-flat or tilted surfaces, as well as samples with three-dimensional surface structures are presented and discussed. The facilitated use of non-amperometric tips in SECM like enzyme-filled glass capillaries is demonstrated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号