首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
对化学毒剂及其降解产物的分析检测是准确鉴别化学沾染的重要手段.由于化学毒剂及其降解产物的样品可能存在于各种基质中,且部分化学毒剂在水体等基质中降解速度过快,所以将痕量样品从复杂基质中快速高效的富集提取出来显得尤其重要.微萃取技术具有装置体积小、使用少量或不使用溶剂、绿色环保、易与色谱分析技术联用等突出优势受到广泛的关注...  相似文献   

2.
A liquid chromatography-mass spectrometry method has been developed for determining bitertanol, carboxin, flutriafol, pyrimethanil, tebuconazole and triadimefon. The evaluation of both atmospheric pressure interfaces (API), atmospheric pressure chemical ionization (APCI) and electrospray (ESI) using positive and negative ionization modes, clearly shows that the studied pesticides are more sensitive using APCI in positive mode. Two procedures based on solid-phase extraction (SPE) and stir-bar sorptive extraction (SBSE) have been assessed for extracting these compounds in grape. The recoveries obtained by SPE in samples spiked at the limit of quantification (LOQ) level ranged from 60 to 100% with relative standard deviation (R.S.D.s) from 7 to 17%. With the SBSE the recoveries obtained from samples spiked at LOQ level were between 15 and 100% and the R.S.D.s between 10 and 19%. The LOQs of most compounds are better by SPE (0.003-0.01 mg kg(-1)) than by SBSE (0.01 mg kg(-1) for all fungicides). Although SPE provided higher recoveries, lower R.S.D.s, best LOQs and is more rapid to carry out compared with SBSE, this last one has some advantages such as lower organic solvent consumption, and cleaner extracts. Results obtained applying both techniques to real samples are analogous.  相似文献   

3.
A new absorbent for solid-phase extraction (SPE) was prepared by a beta-cyclodextrin bonded silica stationary phase (CDS) has been applied to determine the concentrations of phenol compounds in water samples. SPE of selected phenolic compounds from aqueous samples were performed using 250 mg CDS. The determination was subsequently carried out by gas chromatography-flame ionization detection (GC-FID) and gas chromatography-mass spectrometry (GC-MS). Compared with available SPE, the CDS showed high sensitivity and fast velocity of mass transfer for phenolic compound because of its porous structure of beta-cyclodextrin. The relative standard deviation (RSD) for river water sample spiked with phenolic compounds at sub-ppb level was lower than 10% and limit of detection (LOD) for these compounds were between 10 and 100 ng l(-1).  相似文献   

4.
The purpose of this study is to demonstrate an application of 2-D high-performance planar chromatography-diode array detector (DAD) and HPLC-DAD after solid-phase extraction (SPE) for identification and quantitative analysis of pesticides (isoproturon, aziprotryne, hexazinone, flufenoxuron, methabenzthiazuron, procymidone, and α-cypermethrin) in Melissa officinalis L. (Labiatae) samples. The procedure described for the determination of compounds is inexpensive and can be applied to routine analysis of analytes in medical herbs' samples after preliminary cleanup and concentration by SPE. Average recoveries on C18 SPE cartridges of pesticides eluted with 5 mL tetrahydrofuran by the proposed HPLC-DAD method, before and after 2-D-high-performance planar chromatography separation of analytes from M. officinalis L. samples spiked with pesticide at a concentration level of 10 μg/g in plant material are presented. Method validation parameters for the quantification of pesticides by the proposed HPLC-DAD after SPE method are also presented.  相似文献   

5.
The potential of solid-phase extraction (SPE) time-resolved laser-induced fluorimetry (TRLIF) is evaluated for screening polycyclic aromatic hydrocarbons (PAHs) in aqueous samples. Octadecyl membranes are used with the dual purpose of extracting the pollutants from the water sample and serving as the solid substrate for fluorescence detection. Excitation of fluorescence is performed with a Nd:YAG pumped tunable dye laser pumped with a pulsed source for time-resolving spectral interference. Wavelength time matrices (WTMs) and real time-resolved fluorescence spectra are recorded with a pulsed delay generator, a spectrograph and an intensified charge-coupled device (ICCD). In comparison to SPE solid-matrix luminescence (SML) with conventional instrumentation, this approach provides better limits of detection (LOD) and selectivity. The improvement in LOD is of one order of magnitude, reaching the parts-per-trillion level with 10 ml of water sample. The improvement in selectivity allows the direct determination of target compounds in complex samples. The direct determination of benzo[a]pyrene from a spiked river water sample of unknown composition is presented.  相似文献   

6.
A method for the determination of phenoxyalkanoic acids and other polar compounds in environmental water samples without pH adjustment before extraction has been developed. Recoveries were calculated from 500 ml of milliQ water spiked at the level of 0.5 ng/ml using solid-phase extraction (SPE) and HPLC-DAD. Different SPE materials (RP-C18, ENV+, ENV+-C8, SAX and Oasis HLB) were tested. After method optimization, 15 of the 16 compounds studied could be extracted with recoveries better than 70% on the most suitable copolymeric poly(divinylbenzene-co-N-vinylpyrrolidone) material (Oasis HLB cartridges).  相似文献   

7.
气相色谱-质谱法同时测定化妆品中19种邻苯二甲酸酯   总被引:3,自引:0,他引:3  
Liang J  Zhuang W  Wei D  Ou Y  Gong Z 《色谱》2012,30(3):273-279
建立了同时测定化妆品中19种邻苯二甲酸酯的气相色谱-质谱(GC-MS)方法。样品经二氯甲烷超声提取后,用硅胶-中性氧化铝(2:3, m/m)混合填料固相小柱保留、乙酸乙酯-正己烷(8:2, v/v)洗脱等步骤净化后,采用GC-MS对19种目标物进行定性、定量分析。采用保留时间与特征离子丰度比共同进行定性分析,减少了复杂样品基质中的干扰。在优化的实验条件及0.1、0.5、2.0 μg/g的添加水平下,平均加标回收率为72.2%~110.9%,其中加标水平为0.1 μg/g的相对标准偏差(RSD, n=6)小于10.3%;方法检出限(以3倍标准偏差计)为0.0065 μg/g(邻苯二甲酸二异戊酯)~0.062 μg/g(邻苯二甲酸二异丁酯)之间。应用该方法检测了6种化妆品中19种PAEs的含量。该方法可推广用于多种类型化妆品中PAEs的测定。  相似文献   

8.
An analytical method has been developed for measuring 24 chlorinated pesticides in fish tissue samples. Extraction of chlorinated pesticides was carried out by ultrasonication using an acetone-n-hexane (5:2, v/v) mixture. Most of the lipids in the extract were eliminated by freezing-lipid filtration, prior to solid-phase extraction (SPE) cleanup. During freezing-lipid filtration, about 90% of the lipids extracted from the fish samples were easily removed without any significant losses of chlorinated pesticides. For purification, SPE using Florisil was shown to be more effective than silica. Quantification was performed using gas chromatography-mass spectrometry in the selected ion monitoring mode. Spiking experiments were carried out to determine the recovery, precision, and limits of detection (LODs) of the method. The overall recovery was above 80% in the spiked fish tissue sample at 100 ng/g level. The detection limits for chlorinated pesticides were ranged from 0.5 to 5 ppb, except for endosulfan I and II which was 20 ppb. The newly developed method is demonstrated to give efficient recoveries and LODs for detecting chlorinated pesticides spiked into fish tissue with high lipid content.  相似文献   

9.
Seven laboratories participated in an inter-laboratory comparison exercise within the framework of the PRISTINE, SANDRINE and INEXsPORT European Union Projects. Solid-phase extraction (SPE) methodologies were used for the extraction of target analytes from wastewaters. The analytical strategies were based on liquid chromatography (LC) coupled to mass spectrometric (MS) or to fluorescent (FL) detection in all cases with the exception of one laboratory using a test-tube enzyme-linked immunosorbent assay kit. Samples were spiked with the surfactants nonylphenolpolyglycol ether, coconut diethanolamide, linear alkylbenzene sulfonate, nonylphenolpolyglycol ether sulfate, alkylpolyglycol ether and secondary alkane sulfonate. After enrichment on previously conditioned SPE cartridges, the SPE cartridges were distributed among the participating laboratories without the information about the amount of spiked surfactants. In addition, SPE cartridges loaded with a real-world environmental sample containing a tannery wastewater were also analyzed. The results of the programme showed that SPE followed by LC-MS techniques are reliable for the surfactants determination at submicrogram to microgram per liter levels in wastewaters. Inter-laboratory precision values were calculated as the reproducibility relative standard deviation (RSD(R)) which was determined from the reproducibility standard deviation (sR) and the average concentration at a particular concentration level. When data from all laboratories were pooled, the RSD(R) values ranged from 5.1 to 28.3% for the determination of target analytes. The most accurate result corresponded to that given for linear alkylbenzene sulfonates. Taking into account that different methodologies were used (including non-chromatographic techniques) and the complexity of the samples analyzed, it can be considered that acceptable reproducibility values were obtained in this inter-laboratory study.  相似文献   

10.
A pyrrole-based polymer was synthesized and applied as a new sorbent for solid-phase extraction (SPE) of some environmental pollutants from water samples. Polypyrrole (PPy) was synthesized by chemical oxidation of the monomer in nonaqueous solution. SPE of selected phenols, pesticides, and polyaromatic hydrocarbons (PAHs) from aqueous samples were performed using 200 mg PPy. The determination was subsequently carried out by gas chromatography-flame ionization detection (GC-FID) and gas chromatography-mass spectrometry (GC-MS). The polymer showed much higher recoveries for aromatic compounds than aliphatics. Preconcentration of sample volumes up 11 led to acceptable recoveries for aromatic and other tested polar compounds. The R.S.D. for a river water sample spiked with phenols, pesticides and PAHs at sub-ppb level was lower than 10% (n = 3) and limits of detection for these compounds were between 15 and 120 ng l(-1).  相似文献   

11.
A pilot-survey study was performed by collecting samples (influent and effluent wastewaters, rivers and tap waters) from different locations in Europe (Spain, Belgium, Germany and Slovenia). A solid-phase extraction (SPE) followed by liquid chromatography–tandem mass spectrometry method was applied for the determination of pharmaceuticals (ibuprofen, naproxen, ketoprofen, diclofenac and clofibric acid). Method detection limits and method quantification limits were at the parts-per-trillion level (7.5–75 ng/L). The recovery rates of the SPE from deionized water and effluent wastewater samples spiked at 100- and 1,000-ng/L levels ranged from 87 to 95%. Identification criteria in compliance with the EU regulation for confirmatory methods of organic residues were applied. A detailed study of signal suppression evaluation for analysis of pharmaceutical residues in effluent wastewaters is presented.  相似文献   

12.
Solid-phase extraction (SPE) with a molecularly imprinted polymer (MIP) as sorbent has been investigated for the clean-up of the broad-spectrum bacteriostatic antibiotic chloramphenicol (CAP) in honey samples. The MIP was prepared by using methacrylic acid (MAA) as functional monomer, ethylene glycol dimethacrylate (EDMA) as cross-linker, chloroform as porogen and CAP as template molecule. The binding behaviour of the template CAP on the MIP was evaluated by high-performance liquid chromatography, and then the MIP was applied as a sorbent in SPE to selectively extract CAP from honey. It was shown that recoveries of nearly 100% of a CAP standard solution and up to 94% from spiked honey samples could be obtained after SPE.  相似文献   

13.
改进的QuEchERS-串联质谱法测定莴苣中的124种农药残留   总被引:2,自引:0,他引:2  
通过比较d-SPE(PSA+GCB)、SPE(NH2-Carb柱)和SPE(GCB/PSA柱)3种前处理方法的净化效果及方法稳定性,选取了GCB/PSA柱固相萃取作为净化方法。样品经前处理后,采用大体积进样,气相色谱-串联质谱测定,内标法定量。124种农药在浓度为0.010~0.200 mg/kg范围内与峰面积呈线性关系,相关系数均大于0.9800,以10倍信噪比计算,定量限在0.1~19.0μg/kg之间。当农药在样品中添加水平为0.040 mg/kg时,124种农药平均回收率(n=5)为80.0~130.7%,RSD为1.1~2.0%。  相似文献   

14.
A detailed analytical study on ethephon residue determination in water, making use of ion-pairing liquid chromatography coupled to electrospray tandem mass spectrometry (LC/MS/MS), has been carried out. Ethephon is a plant growth regulator, highly polar, which is typically present in aqueous solution in anionic form due to its acid character. Both its extraction and pre-concentration from water samples and its chromatographic retention are difficult. Several approaches for sample pretreatment have been tested including direct injection into the chromatographic system, on-line solid phase extraction (SPE) and off-line SPE, with the best results being obtained after off-line SPE, using Oasis MAX cartridges (mixed-mode strong anion-exchange). After testing several ion-pairing reagents, tetrabuthylammonium acetate (TBA) was selected. This was added to the samples before LC/MS/MS analysis to facilitate ethephon chromatographic retention. The acquisition of several specific MS/MS transitions together with the evaluation of their relative intensity ratios allowed the reliable confirmation of the analyte in samples. The optimised approach was tested in low-salinity water spiked at 0.1?µg?L?1 level with satisfactory recovery, and a limit of detection of 0.02?µg?L?1. To this purpose, the water sample was partially de-ionised in an initial stage, in order to remove major ions that would have interfered in analyses. The application of this methodology to more saline/complex water samples, as surface or wastewater, was problematic and a thorough optimisation of the de-ionisation conditions would be required.  相似文献   

15.
Zhang Y  Yang J  Shi R  Su Q  Yao L  Li P 《Journal of separation science》2011,34(14):1675-1682
A method was developed to determine eight acetanilide herbicides from cereal crops based on accelerated solvent extraction (ASE) and solid-phase extraction (SPE) followed by gas chromatography-electron capture detector (GC-ECD) analysis. During the ASE process, the effect of four parameters (temperature, static time, static cycles and solvent) on the extraction efficiency was considered and compared with shake-flask extraction method. After extraction with ASE, four SPE tubes (graphitic carbon black/primary secondary amine (GCB/PSA), GCB, Florisil and alumina-N) were assayed for comparison to obtain the best clean-up efficiency. The results show that GCB/PSA cartridge gave the best recoveries and cleanest chromatograms. The analytical process was validated by the analysis of spiked blank samples. Performance characteristics such as linearity, limit of detection (LOD), limit of quantitation (LOQ), precision and recovery were studied. At 0.05 mg/kg spiked level, recoveries and precision values for rice, wheat and maize were 82.3-115.8 and 1.1-13.6%, respectively. For all the herbicides, LOD and LOQ ranged from 0.8 to 1.7 μg/kg and from 2.4 to 5.3 μg/kg, respectively. The proposed analytical methodology was applied for the analysis of the targets in samples; only three herbicides, propyzamid, metolachlor and diflufenican, were detected in two samples.  相似文献   

16.
采用乙腈提取、固相萃取(SPE)富集浓缩技术结合自行研制开发的毛细管液相色谱(CLC)仪,同时分离测定了食品和水样中1种有机磷和3种氨基甲酸酯类杀虫剂残留。对影响SPE效率和CLC分离检测的各类因素进行了优化,包括固相萃取柱种类、样品pH、洗脱剂种类和体积、上样速率、盐效应、上样体积、检测波长、流动相种类和比例等。结果表明,4种杀虫剂在6 min内达到完全分离,检出限为0.35~1.20 μg/kg,定量限为1.17~4.00 μg/kg。使用该SPE-CLC法对西红柿、黄瓜、苹果样品和自来水、湖水水样进行加标回收测定,得到食品中加标回收率为72.41%~107.15%,相对标准偏差≤8.12%;水样中加标回收率为71.45%~109.25%,相对标准偏差≤9.28%。该法能够满足农药多残留分析要求。  相似文献   

17.
In the development of a screening method for the determination of residues of mecoprop in soils involving coupled-column RPLC-UV (228 nm) the cleanup performance of a 5 μm GFF-II internal surface reversed phase (ISRP, Pinkerton) analytical column (50 × 4.6 mm I.D.) as a first column was investigated. In comparison to an analytical C18 column the ISRP column substantially improved the separation between acidic analyte and co-extracted humic substances. Under the selected coupled-column conditions soil extracts obtained after hydrolysis with an aqueous alkaline solution, acidifying and centrifugation could be analyzed directly allowing the determination of mecoprop in soils to a level of about 0.02 mg/kg. A rapid concentration step on a 100 mg C18 solid phase extraction (SPE) cartridge was adopted into the procedure providing a limit of detection (S/N = 3) of 0.01 mg/kg of mecoprop in soil. The method was validated by analyzing freshly spiked soil samples and samples with aged residues. In case of freshly spiked samples the overall recovery was 87% (n = 18, spiked level 0.02–8.0 mg/kg) with a repeatability of 6.8% and a reproducibility of 8.3%. No significant decrease of the recovery was observed for samples with aged residues (n = 15, spiked level 0.1 and 8.0 mg/kg) during a storage of 29 days in the refrigerator at about 4?°C; a storage of 67 days provided a mean recovery of 76% (n = 14, spiked level 8.0 mg/kg).  相似文献   

18.
陈婷  温裕云  欧延  弓振斌 《色谱》2014,32(1):89-94
建立了固相萃取(SPE)净化、超高效液相色谱-串联质谱(UHPLC-MS/MS)测定橡胶制品中13种N-亚硝胺的方法。样品于密闭萃取瓶中于60 ℃下用甲醇超声萃取30 min,C18固相萃取小柱对萃取液进行净化,经C18色谱柱分离,最后用电喷雾正离子(ESI+)和多重反应监测模式(MRM)对13种N-亚硝胺进行定性、定量测定。实验中对样品前处理、色谱分离条件和质谱检测条件进行了优化。在优化的实验条件下,橡胶样品中添加N-亚硝基二甲胺(NDMA)与N-亚硝基-二乙基胺(NDEA)为500 μg/kg、其他组分均为50 μg/kg时,各组分的相对标准偏差(RSD,n=7)小于10%;在实际样品中的加标回收率为70.7%~117.0%;方法的检出限(LOD,以10倍标准偏差计)为0.5~500 μg/kg。方法可应用于橡胶制品中13种N-亚硝胺的测定。  相似文献   

19.
A method is reported for the determination, in water samples, of 10 quinolones which are used as veterinary drugs. Analytes are isolated from samples by solid-phase extraction (SPE) and analysed by reversed-phase high-performance liquid chromatography using fluorimetric detection. A solid-phase extraction procedure based on retention on HBL OASIS cartridges and elution with a mixture of acetonitrile-water in basic medium is suitable for pre-concentration of the analytes. Pre-concentration factors up to 250 can be obtained. The quinolones are separated with an octyl silica-based column and mobile phases consisting of aqueous oxalic acid solutions and acetonitrile mixtures. The attained detection limits of the whole process are in the ng l(-1) level when 250 ml of water sample is processed. Recovery rates, from natural water samples spiked at 2060 ng l(-1) level, range from 70 to 100% and common standard deviation are about 6-12%.  相似文献   

20.
Solid-phase extraction (SPE) procedures for cleanup and preconcentration followed by HPLC-UV method were investigated for the simultaneous determination of seven low-dosed pesticides in saline concentrates for hemodialysis. The target compounds were ametryn, desmetryn, prometryn, terbutryn, molinate, triallate and butylate. Polyethylene (three different types), teflon, polyurethane and polystyrene, in powder form, were investigated as adsorbents for solid-phase extraction of the analytes from the saline samples. Quantification was performed at 222 nm and the analytes were separated on a LiChrosorb RP-18 (5 μm, 125 mm × 4 mm i.d.) column using gradient elution with water/acetonitrile as mobile phase. The duration each chromatographic run was 18 min including column reconditioning. The efficiency of the different SPE substrates for retaining the analytes from the highly concentrated saline (HCS) samples was discussed. The best performance was achieved with polystyrene as SPE material considering preconcentration factor, precolumn clogging, reusing capability and similarity between the mobile phases for SPE and HPLC procedures. Analyte concentrations as low as 1 μg L−1 could be determined in spiked HCS samples after preconcentration on polystyrene SPE precolumns. Recoveries between 98.7 and 102.2% were obtained from commercial spiked samples. Detection limits ranging from 4.8 (for prometryn) to 46 μg L−1 (for butylate) were calculated (without preconcentration). The within-day relative standard deviations (n = 9) ranged from 2.3 to 4.8%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号