首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The paper presents a new HPLC method, with UV and MSn detection, for the determination of seven pesticides, including the sulfonylurea herbicides amidosulfuron, azimsulfuron, nicosulfuron, rimsulfuron, thifensulfuron methyl, tribenuron methyl, and the fungicide azoxystrobin characterised by a methoxyacrilate structure. The methodology consists of a preconcentration/SPE (solid phase extraction) step and HPLC-UV (240 nm detection wavelength)-MSn analysis. Under the optimised conditions and after a 1000/1 preconcentration factor, the limits of detection were lower than 14.5 ng L−1 for UV detection and lower than 8.1 ng L−1 for MS detection. The limits of quantification were lower than 48.3 ng L−1 in UV detection and than 26.9 ng L−1 in MSn detection. The analysis of two samples, spiked with a mixture of the pesticides at threshold level concentrations, gave more than 60% recovery.  相似文献   

2.
A rapid and sensitive method for the determination of carbendazim (methyl benzimidazole-2-ylcarbamate, MBC) and thiabendazole (TBZ) in water and soil samples was developed by using dispersive liquid-liquid microextraction (DLLME) coupled with high performance liquid chromatography with fluorescence detection. The water samples were directly used for the DLLME extraction. For soil samples, the target analytes were first extracted by 0.1 mol L−1 HCl. Then, the pH of the extract was adjusted to 7.0 with 2 mol L−1 NaOH before the DLLME extraction. In the DLLME extraction method, chloroform (CHCl3) was used as extraction solvent and tetrahydrofuran (THF) as dispersive solvent. Under the optimum conditions, the enrichment factors for MBC and TBZ were ranged between 149 and 210, and the extraction recoveries were between 50.8 and 70.9%, respectively. The linearity of the method was obtained in the range of 5-800 ng mL−1 for water sample analysis, and 10-1000 ng g−1 for soil samples, respectively. The correlation coefficients (r) ranged from 0.9987 to 0.9997. The limits of detection were 0.5-1.0 ng mL−1 for water samples, and 1.0-1.6 ng g−1 for soil samples. The relative standard deviations (RSDs) varied from 3.5 to 6.8% (n = 5). The recoveries of the method for MBC and TBZ from water samples at spiking levels of 5 and 20 ng mL−1 were 84.0-94.0% and 86.0-92.5%, respectively. The recoveries for soil samples at spiking levels of 10 and 100 ng g−1 varied between 82.0 and 93.4%.  相似文献   

3.
A group selective molecularly imprinted solid phase extraction (MISPE) for malachite green (MG) from fish water and fish feed samples was developed. Using MG as template molecule, methacrylic acid as functional monomer, ethylene glycoldimethacrylate as linking agent and bulk polymerization as synthetic method, the molecularly imprinted polymers (MIPs) were synthesized and characterized with rebinding experiment. The Scatchard polt's analysis revealed that the template-polymer system showed the two-site binding behavior with dissociation constants of 0.3194 μmol L−1 and 15.70 μmol L−1, respectively. MG and two structurally related compounds, leucomalachite green (LMG) and crystal violet (CV) were employed for selectivity test. The MIPs exhibited the highest selective rebinding to MG, but also displayed 83.0% and 87.5% of cross-reactivity with LMG and CV, demonstrating that MIPs could be used as group recognition sorbents in solid phase extraction. The extraction conditions of MISPE column for MG were optimized. Tap water samples spiked with MG at concentration of 0.5-10 ng mL−1 were extracted by MISPE column and analyzed by high performance liquid chromatography. The recoveries of MISPE column for MG extraction were found to be 76.8-93.7% with the relative standard deviations of 2.12-10.09%, indicating the feasibility of the prepared MIPs for MG extraction. No detectable MG was observed in one fish farming water sample and two fish feed samples; while the MG concentrations in two pet fishpond water samples were found at 1.50 ng mL−1 and 0.67 ng mL−1, respectively.  相似文献   

4.
Orthogonal array design (OAD) was utilized for the first time to optimize the experimental conditions of ultrasound-assisted emulsification–microextraction (USAEME) for determining chlorinated phenoxyacetic acids (CPAs) in river water samples. The use of ultrasound facilitates the mass transfer of CPAs from an aqueous phase into a water-immiscible organic extraction solvent (dichloromethane, DCM) without adding dispersive solvent to form numerous microdroplets. The water-immiscible extractant was collected by centrifugation, dried under low pressure, reconstituted in methanol–water mixture (1:1), and injected into a HPLC system for the determination of CPAs. The linear range was 2–1000 ng mL−1 (2, 5, 10, 50, 200, 500 and 1000 ng mL−1) for each analyte and the relative standard deviations of CPAs among the seven different concentrations were in the range of 1.5–17.0% (n = 3). The detection limits (signal-to-noise ratio of 3) of CPAs ranged from 0.67 to 1.50 ng mL−1. The ranges of intra-day precision (n = 3) for CPAs at the levels of 5 and 200 ng mL−1 were 3.6–11.9% and 5.3–9.5%, respectively. The range of inter-day precision (n = 3) at 5 and 200 ng mL−1 were 1.4–7.7% and 8.5–12.2%, respectively. The applicability of USAEME for environmental analysis was demonstrated by determining CPAs in river water. The recoveries of CPAs from five-spiked river water samples at 10 and 200 ng mL−1 were 96.3–112.5% and 94.8–109.4%, respectively. The maximum contaminant level (MCL) of 2,4-D in drinking water and the tolerance of residues in food for p-CPA are 70 and 200 μg L−1, respectively, according to the US EPA regulations. These contaminant levels fall in the linear range investigated in this study. In addition, this USAEME method provided detection limits lower than their contaminant levels, which made USAEME an effective sample preparation method for determining organic environmental contaminants, such as CPAs, in river water samples with little consumption of organic solvent.  相似文献   

5.
A rapid and solvent-free method for the determination of eight volatile organic sulphur and two selenium compounds in different beverage samples using headspace solid-phase microextraction and gas chromatography with atomic emission detection has been developed. The bonded carboxen/polydimethylsiloxane fiber was the most suitable for preconcentrating the analytes from the headspace of the sample solution. Volumes of 20 mL of undiluted beer were used while, in the case of wines and spirits, sample:water ratios of 5:15 and 2:18, respectively, were used, in order to obtain the maximum sensitivity. Quantitation was carried out by using synthetic matrices of beer and wine, and a spiked sample for spirits, and using ethyl methyl sulphide and isopropyl disulphide as internal standards. Detection limits ranged from 8 ng L−1 to 40 ng mL−1, depending on the compound and the beverage sample analyzed, with a fiber time exposure of 20 min at ambient temperature. The optimized method was successfully applied to different samples, some of the studied compounds being detected at concentration levels in the 0.04–152 ng mL−1 range.  相似文献   

6.
A sensitive and selective column adsorption method is proposed for the preconcentration and determination of atrazine and simazine. Atrazine and simazine were preconcentrated on heat-treated diatomaceous earth as an adsorbent and then determined by high-performance liquid chromatography (HPLC). Several parameters on the recoveries of the analytes were investigated. The experimental results showed that it was possible to obtain quantitative analysis when the solution pH was 2 using 100 mL of validation solution containing 1.5 μg of triazines and 5 mL of ethanol as an eluent. Recoveries of atrazine and simazine were 95.7 ± 4.2% and 75.0 ± 1.9% with a relative standard deviation for seven determinations of 4.7% and 2.7% under optimum conditions. The maximum preconcentration factor was 100 for triazines when 500 mL of sample solution volume was used. The linear ranges of calibration curves for atrazine and simazine were 1-150 ng mL−1 and 1-300 ng mL−1, respectively, with correlation coefficients of 0.999 and the detection limits (3Signal-to-Noise) were 0.24 ng mL−1 and 0.21 ng mL−1 for atrazine and simazine. The capacity of the adsorbent was also examined and found to be 0.8 mg g−1 and 1.3 mg g−1 for atrazine and simazine, respectively. The proposed method was successfully applied to the determination of triazines in river water and tap water samples with high precision and accuracy.  相似文献   

7.
A novel photonic suspension array was developed for multiplex immunoassay. The carries of this array were silica colloidal crystal beads (SCCBs). The codes of these carriers are the characteristic reflection peak originated from their structural periodicity, and therefore they do not suffer from fading, bleaching, quenching, and chemical instability. In addition, because no dyes or materials related with fluorescence are included, the fluorescence background of SCCBs is very low. With a sandwich format, the proposed suspension array was used for simultaneous multiplex detection of tumor markers in one test tube. The results showed that the four tumor markers, α-fetoprotein (AFP), carcinoembryonic antigen (CEA), carcinoma antigen 125 (CA 125) and carcinoma antigen 19-9 (CA 19-9) could be assayed in the ranges of 1.0-500 ng mL−1, 1.0-500 ng mL−1, 1.0-500 U mL−1 and 3.0-500 U mL−1 with limits of detection of 0.68 ng mL−1, 0.95 ng mL−1, 0.99 U mL−1 and 2.30 U mL−1 at 3σ, respectively. The proposed array showed acceptable accuracy, detection reproducibility, storage stability and the results obtained were in acceptable agreement with those from parallel single-analyte test of practical clinical sera. This technique provides a new strategy for low cost, automated, and simultaneous multiplex immunoassay.  相似文献   

8.
Li Y  Wei G  Hu J  Liu X  Zhao X  Wang X 《Analytica chimica acta》2008,615(1):96-103
A simple, rapid and efficient method, dispersive liquid-liquid microextraction (DLLME), has been developed for the extraction and preconcentration of polybrominated diphenyl ethers (PBDEs) in water samples. The factors influencing microextraction efficiencies, such as the kind and volume of extraction and dispersive solvent, the extraction time and the salt effect, were optimized. Under the optimum conditions (sample volume: 5 mL; extraction solvent: tetrachloroethane, 20.0 μL; dispersive solvent: acetonitrile, 1.00 mL; extraction time: below 5 s and without salt addition), the enrichment factors and extraction recoveries were high and ranged from 268 to 305 and 87.0 to 119.1%, respectively. Linearity was observed in the range 0.05-50 ng mL−1 for BDE-28 and BDE-99, and 0.1-100 ng mL−1 for BDE-47 and BDE-209, respectively. Coefficients of correlation (r2) ranged from 0.9995 to 0.9999. The repeatability study was carried out by extracting the spiked water samples at concentration levels of 50 ng mL−1 for BDE-28 and BDE-99, and 100 ng mL−1 for BDE-47 and BDE-209, respectively. The relative standard deviations (R.S.D.s) varied between 3.8 and 6.3% (n = 5). The limits of detection (LODs), based on signal-to-noise ratio (S/N) of 3, ranged from 12.4 to 55.6 pg mL−1 (the wavelength of detector at 226 nm). The relative recoveries of PBDEs from tap, lake water and landfill leachate samples at spiking levels of 5, 10 and 50 ng mL−1 were in the range of 89.7-107.6%, 114.3-119.1% and 87.0-90.9%, respectively. As a result, this method can be successfully applied for the determination of PBDEs in landfill leachate and environmental water samples.  相似文献   

9.
In this work, a simple, rapid and sensitive sample pretreatment technique, dispersive liquid-liquid microextraction (DLLME) coupled with high performance liquid chromatography-fluorescence detection (HPLC-FLD), has been developed to determine carbamate (carbaryl) and organophosphorus (triazophos) pesticide residues in water and fruit juice samples. Parameters, affecting the DLLME performance such as the kind and volume of extraction and dispersive solvents, extraction time and salt concentration, were studied and optimized. Under the optimum extraction conditions (extraction solvent: tetrachloroethane, 15.0 μL; dispersive solvent: acetonitrile, 1.0 mL; no addition of salt and extraction time below 5 s), the performance of the proposed method was evaluated. The enrichment factors for the carbaryl and triazophos were 87.3 and 275.6, respectively. The linearity was obtained in the concentration range of 0.1-1000 ng mL−1 with correlation coefficients from 0.9991 to 0.9999. The limits of detection (LODs), based on signal-to-noise ratio (S/N) of 3, ranged from 12.3 to 16.0 pg mL−1. The relative standard deviations (RSDs, for 10 ng mL−1 of carbaryl and 20 ng mL−1 of triazophos) varied from 1.38% to 2.74% (n = 6). The environmental water (at the fortified level of 1.0 ng mL−1) and fruit juice samples (at the fortified level of 1.0 and 5.0 ng mL−1) were successfully analyzed by the proposed method, and the relative recoveries of them were in the range of 80.4-114.2%, 89.8-117.9% and 86.3-105.3%, respectively.  相似文献   

10.
The effect of dimensions (length and external diameter) of multi-walled carbon nanotubes (MWCNTs) on its preconcentration efficiency towards some metal ions (Pb2+, Cd2+, Cu2+, Zn2+ and MnO4) from environmental waters prior to their analysis by flame atomic absorption spectroscopy (FAAS) was investigated. MWCNTs (as-received from the manufacturer) of various external diameters and lengths were involved. Other variables optimized included effects of pH of water sample, composition and volume of eluent, mass of the MWCNTs, breakthrough volume and coexisting ions. Maximum recovery of metal ions was obtained at pH 9 where it was thought that precipitation of metals as their hydroxides played the major factor in metals uptake by MWCNT. It was suggested that the use of appropriate dimensions of MWCNTs may support the trapping process of the precipitated metal hydroxides by MWCNTs. It was found that long MWCNT of length 5-15 μm and external diameter 10-30 nm gave the highest enrichment efficiency towards almost all the targeted metal ions. It could be used for preconcentration of MnO4, Cu2+, Zn2+ and Pb2+ with almost full recovery; but not for Cd2+ due to its low recovery. The optimized solid phase extraction (SPE) procedure was capable of determining metal ions in the linear range 20-100 ng mL−1 (except for Zn2+ from 20 to 150 ng mL−1). Detection limits were 0.709 ng mL−1 for MnO4, 0.278 ng mL−1 for Pb2+, 0.465 ng mL−1 for Cu2+, 0.867 ng mL−1 for Zn2+. Application of the optimized SPE procedure to environmental waters (tap water, reservoir water and stream water) gave spike recoveries of the metals in the range of 81-100%.  相似文献   

11.
Polyclonal antibody (PAb) with broad-specificity for O,O-diethyl organophosphorus pesticides (OPs) against a generic hapten, 4-(diethoxyphosphorothioyloxy)benzoic acid, was produced. The obtained PAb showed high sensitivity to seven commonly used O,O-diethyl OPs in a competitive indirect enzyme-linked immunosorbent assay (ciELISA) using a heterologous coating antigen, 4-(3-(diethoxyphosphorothioyloxy)phenylamino)-4-oxobutanoic acid. The 50% inhibition value (IC50) was 348 ng mL−1 for parathion, 13 ng mL−1 for coumaphos, 22 ng mL−1 for quinalphos, 35 ng mL−1 for triazophos, 751 ng mL−1 for phorate, 850 ng mL−1 for dichlofenthion, and 1301 ng mL−1 for phoxim. The limit of detection (LOD) met the ideal detection criteria of all the seven OP residues. A quantitative structure-activity relationship (QSAR) model was constructed to study the mechanism of antibody recognition using multiple linear regression analysis. The results indicated that the frontier-orbital energies (energy of the highest occupied molecular orbital, EHOMO, and energy of the lowest unoccupied molecular orbital, ELUMO) and hydrophobicity (log of the octanol/water partition coefficient, log P) were mainly responsible for the antibody recognition. The linear equation was log(IC50) = −63.274EHOMO + 15.985ELUMO + 0.556 log P − 25.015, with a determination coefficient (r2) of 0.908.  相似文献   

12.
Abdorreza Mohammadi 《Talanta》2009,78(3):1107-1114
A simple and rapid headspace solid-phase microextraction (HS-SPME) based method is presented for the simultaneous determination of atrazine and ametryn in soil and water samples by ion mobility spectrometry (IMS). A dodecylsulfate-doped polypyrrole (PPy-DS), synthesized by electrochemical method, was applied as a laboratory-made fiber for SPME. The HS-SPME system was designed with a cooling device on the upper part of the sample vial and a circulating water bath for adjusting the sample temperature. The extraction properties of the fiber to spiked soil and water samples with atrazine and ametryn were examined, using a HS-SPME device and thermal desorption in injection port of IMS. Parameters affecting the extraction efficiency such as the volume of water added to the soil, pH effect, extraction time, extraction temperature, salt effect, desorption time, and desorption temperature were investigated. The HS-SPME-IMS method with PPy-DS fiber, provided good repeatability (RSDs < 10 %), simplicity, good sensitivity and short analysis times for spiked soil (200 ng g−1) and water samples (100 and 200 ng mL−1). The calibration graphs were linear in the range of 200-4000 ng g−1 and 50-2800 ng mL−1 for soil and water respectively (R2 > 0.99). Detection limits for atrazine and ametryn were 37 ng g−1 (soil) and 23 ng g−1 (soil) and 15 ng mL−1 (water) and 10 ng mL−1 (water), respectively. To evaluate the accuracy of the proposed method, atrazine and ametryn in the three kinds of soils and two well water samples were determined. Finally, comparing the HS-SPME results for extraction and determination of selected triazines using PPy-DS fiber with the other methods in literature shows that the proposed method has comparable detection limits and RSDs and good linear ranges.  相似文献   

13.
A new suspension array built upon laboratory-prepared functional fluorescence-encoded polystyrene beads (FFPBs) was developed for multiplex immunodetection of tumor markers. The FFPBs were synthesized by copolymerizing rhodamine 6G (R6G) and carboxyl function groups on the surface of the seed beads forming a core-shell structure. The fabrication process was facile and the encoding fluorescence intensity of the beads can be precisely controlled by adjusting the quantity of R6G. In present work, we demonstrated that the quantity variation of impregnated R6G had negligible effect on the coupling efficiency of biomolecules onto the surface of the FFPBs. The R6G encoding fluorescence remained good monodispersity upon capture probe coupling and immunocomplex formation. No fluorescence resonance energy transfer was observed between the R6G doped in the bead shell and fluorophore used for antibody labeling. Under the optimal conditions, the proposed suspension array allowed simultaneous detection of α-fetoprotein, carcinoembryonic antigen, and prostate specific antigen in the ranges of 0.07-500 ng mL−1, 1-2000 ng mL−1, and 0.5-500 ng mL−1, respectively, with detection limits of 0.0626 ng mL−1, 0.554 ng mL−1, and 0.250 ng mL−1. Test on clinical serum samples demonstrated that the results obtained with suspension array were in good agreement with those of the reference electrochemiluminescence immunoassay method. We conclude that the laboratory-made FFPBs are sufficient as the microcarrier for the construction of suspension array in clinical diagnosis.  相似文献   

14.
In this paper a novel solid phase extraction method to determine Co(II) and Ni(II) using silica gel-polyethylene glycol (Silica-PEG) as a new adsorbent is described. The method is based on the adsorption of cobalt and nickel ions in alkaline media on polyethylene glycol-silica gel in a mini-column, elution with nitric acid and determination by flame atomic absorption spectrometry. The adsorption conditions such as NaOH concentration, sample volume and amount of adsorbent were optimized in order to achieve highest sensitivity. The calibration graph was linear in the range of 0.5-200.0 ng mL−1 for Co(II) and 2.0-100.0 ng mL−1 for Ni(II) in the initial solution. The limit of detection based on 3Sb was 0.37 ng mL−1 for Co(II) and 0.71 ng mL−1 for Ni(II). The relative standard deviations (R.S.D.) for ten replicate measurements of 40 ng mL−1 of Co(II), and Ni(II) were 3.24 and 3.13%, respectively. The method was applied to determine Co(II) and Ni(II) in black tea, rice flour, sesame seeds, tap water and river water samples.  相似文献   

15.
Fan Z 《Analytica chimica acta》2007,585(2):300-304
A simple and sensitive method for using electrothermal atomic absorption spectrometry (ET AAS) with Rh as permanent modifier determination of Sb(III) and total Sb after separation and preconcentration by N-benzoyl-N-phenylhydroxylamine (BPHA)-chloroform single drop has been developed. Parameters, such as pyrolysis and atomization temperature, solvent type, pH, BPHA concentration, extraction time, drop size, stirring rate and sample volume were investigated. Under the optimized experimental conditions, the detection limits (3σ) were 8.0 ng L−1 for Sb(III) and 9.2 ng L−1 for total Sb, respectively. The relative standard deviations (R.S.Ds.) were 6.6% for Sb(III) and 7.1% for total Sb (c = 0.2 ng mL−1, n = 7), respectively. The enrichment factor was 96. The developed method has been applied successfully to the determination of Sb(III) and total Sb in natural water samples.  相似文献   

16.
In the present study a cloud point extraction process using mixed micelle of the cationic surfactant cetyl-pyridinium chloride (CPC) and non-ionic surfactant Triton X-114 for extraction of beryllium from aqueous solutions is developed. The extraction of analyte from aqueous samples was performed in the presence of 1,8-dihydroxyanthrone as chelating agent in buffer media of pH 9.5. After phase separation, the surfactant-rich phase was diluted with 0.4 mL of a 60:40 methanol-water mixture containing 0.03 mL HNO3. Then, the enriched analyte in the surfactant-rich phase was determined by inductively coupled plasma-atomic emission spectrometry (ICP-AES). The different variables affecting the complexation and extraction conditions were optimized. Under the optimum conditions (i.e. 1.6 × 10−4 mol L−1 1,8-dihydroxyanthrone, 1.2 × 10−4 mol L−1 CPC, 0.15% (v/v) Triton X-114, 50 °C equilibrium temperature) the calibration graph was linear in the range of 0.006-80 ng mL−1 with detection limit of 0.001 ng mL−1 and the precision (R.S.D.%) for five replicate determinations at 18 ng mL−1 of Be(II) was better than 2.9%. In this manner the preconcentration and enrichment factors were 16.7 and 24.8, respectively. Under the presence of foreign ions no significant interference was observed. Finally, the proposed method was successfully utilized for the determination of this cation in water samples.  相似文献   

17.
A simple and rapid method based on solid-phase micro extraction (SPME) technique followed by gas chromatography-mass spectrometry with selected ion monitoring (GC-MS, SIM) was developed by the simultaneous determination of 16 pesticides of seven different chemical groups [Six organophosphorus (trichlorfon, diazinon, methyl parathion, malathion, fenthion and ethyon), three pyrethroids (bifenhin, permethrin, cypermethrin), two imidazoles (imazalil and prochloraz), two strobilurins (azoxystrobin and pyraclostrobin), one carbamate (carbofuran), one tetrazine (clofentezine), and one triazole (difenoconazole)] in water. The pesticides extraction was done with direct immersion mode (DI-SPME) of the polyacrilate fiber (PA 85 µm). The extraction temperature was adjusted to 50 °C during 30 min, while stirring at 250 rpm was applied. After extraction, the fiber was introduced in the GC injector for thermal desorption for 5 min. at 280 °C. The method was validated using ultra pure water samples fortified with pesticides at different concentration levels and shows good linearity in the concentrations between 0.05 and 250.00 ng mL− 1. The LOD and LOQ ranged, from 0.02 to 0.30 ng mL− 1 and 0.05 to 1.00 ng mL− 1, respectively. Intra-day and inter-day precisions were determined in two concentration levels (5.00 and 50.00 ng mL− 1). Intra-day relative standard deviation (%R.S.D.) ranged between 3.6 and 13.6%, and inter-day (%R.S.D.) ranged between 6.3 and 18.5%. Relative recovery tests were carried out spiking the ultra pure sample with standards in three different concentration levels 0.20, 5.00 and 50.00 ng mL− 1. The recovery at 0.20 ng mL− 1 level varied from 86.4 ± 9.4% to 108.5 ± 10.5%, at 5.00 ng mL− 1 level varied from 77.5 ± 10.8% to 104.6 ± 9.6% and at 50.00 ng mL− 1 level varied from 70.2 ± 4.6% to 98.4 ± 8.5%. The proposed SPME method was applied in twenty-six water samples collected in the “Platô de Neópolis”, State of Sergipe, Brazil. Methyl parathion was detected in five samples with an average concentration of 0.17 ng mL− 1 and bifenthrin, pyraclostrobin and azoxystrobin residues were found in three samples with average concentrations of 2.28, 3.12 and 0.15 ng mL− 1, respectively.  相似文献   

18.
Enriching the surface density of immobilized capture antibodies enhances the detection signal of antibody sandwich microarrays. In this study, we improved the detection sensitivity of our previously developed P-Si (porous silicon) antibody microarray by optimizing concentrations of the capturing antibody. We investigated immunoassays using a P-Si microarray at three different capture antibody (PSA – prostate specific antigen) concentrations, analyzing the influence of the antibody density on the assay detection sensitivity. The LOD (limit of detection) for PSA was 2.5 ng mL−1, 80 pg mL−1, and 800 fg mL−1 when arraying the PSA antibody, H117 at the concentration 15 μg mL−1, 35 μg mL−1, and 154 μg mL−1, respectively. We further investigated PSA spiked into human female serum in the range of 800 fg mL−1 to 500 ng mL−1. The microarray showed a LOD of 800 fg mL−1 and a dynamic range of 800 fg mL−1 to 80 ng mL−1 in serum spiked samples.  相似文献   

19.
Arpa Şahin C  Durukan I 《Talanta》2011,85(1):657-661
In this article, a new ligandless solidified floating organic drop microextraction (LL-SFODME) method has been developed for preconcentration of trace amount of cadmium as a prior step to its determination by flow injection-flame atomic absorption spectrometry (FI-FAAS). The methodology is based on the SFODME of cadmium with 1-dodecanol in the absence of chelating agent. Several factors affecting the microextraction efficiency, such as, pH, sodium dodecylbenzenesulfonate (SDBS) concentration, extraction time, stirring rate and temperature were investigated and optimized. Under optimized experimental conditions an enhancement factor of 205 was obtained for 100 mL of sample solution. The calibration graph was linear in the range of 1.0-25.0 ng mL−1, the limit of detection (3s) was 0.21 ng mL−1 and the limit of quantification (10s) was 0.62 ng mL−1. The relative standard deviation (RSD) for 10 replicate measurements of 10 ng mL−1 cadmium was 4.7%. The developed method was successfully applied to the extraction and determination of cadmium in standard and several water samples and satisfactory results were obtained.  相似文献   

20.
Determination of estrogens in water by HPLC-UV using cloud point extraction   总被引:1,自引:0,他引:1  
Wang L  Cai YQ  He B  Yuan CG  Shen DZ  Shao J  Jiang GB 《Talanta》2006,70(1):47-51
A method based on cloud point extraction was developed to determine four kinds of estrogens: estriol (E3), estradiol (E2), estrone (E1), and progesterone (P) in water by high performance liquid chromatography separation and ultraviolet detection (HPLC-UV). The non-ionic surfactant Triton X-114 was chosen as extractant solvent. The parameters affecting extraction efficiency, such as concentrations of Triton X-114 and Na2SO4, equilibration temperature, equilibration time and centrifugation time were evaluated and optimized. Under the optimum conditions, preconcentration factors of 99 for E3, 73 for E2, 152 for E1 and 86 for P were obtained for 10 mL water sample. The detection of limitation was 0.23 ng mL−1 for E3, 0.32 ng mL−1 for E2, 0.25 ng mL−1 for E1 and 5.0 ng mL−1 for P. The proposed method was successfully applied to the determination of trace amount of estrogens in wastewater treatment plant (WWTP) effluent water and exposure water with 10 ng mL−1 E2 for toxicological study in our lab. For the case of WWTP effluent water samples, no estrogen was found. The accuracy of the proposed method was tested by recovery measurements of spiked samples and good recoveries of 81.2-99.5% were obtained.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号