首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 500 毫秒
1.
Molecularly imprinted polymer (MIP)-based synthetic receptors integrated with Surface Acoustic Wave (SAW) sensing platform were applied for the first time for label-free protein detection. The ultrathin polymeric films with surface imprints of immunoglobulin G (IgG-MIP) were fabricated onto the multiplexed SAW chips using an electrosynthesis approach. The films were characterized by analyzing the binding kinetics recorded by SAW system. It was revealed that the capability of IgG-MIP to specifically recognize the target protein was greatly influenced by the polymer film thickness that could be easily optimized by the amount of the electrical charge consumed during the electrodeposition. The thickness-optimized IgG-MIPs demonstrated imprinting factors towards IgG in the range of 2.8–4, while their recognition efficiencies were about 4 and 10 times lower toward the interfering proteins, IgA and HSA, respectively. Additionally, IgG-MIP preserved its capability to recognize selectively the template after up to four regeneration cycles. The presented approach of the facile integration of the protein-MIP sensing layer with SAW technology allowed observing the real-time binding events of the target protein at relevant sensitivity levels and can be potentially suitable for cost effective fabrication of a biosensor for analysis of biological samples in multiplexed manner.  相似文献   

2.
In this work, a combination of complementary metal-oxide semiconductor (CMOS) microchip system with capillary array electrophoresis (CAE) is demonstrated as a system for optimizing conditions for enzymatic reaction. Dimethylacridinone (DDAO)-phosphate substrate and alkaline phosphatase conjugate were selected for the enzymatic reaction, which was applicable to the enzyme-linked immunosorbent assay (ELISA) technique. Laser-induced fluorometry with a miniature semiconductor laser was used to detect the enzymatic products. The speed of the enzymatic reaction between the DDAO-phosphate and the alkaline phosphatase conjugate was investigated as a function of reaction time. The microchip-CAE detection system could determine the pH condition and the concentration of enzyme that are suitable for rapid and low-cost analysis. This result shows the feasibility of using the microchip-CAE system for application to miniaturized screening systems.  相似文献   

3.
A C60‐polyphenylacetylene (C60‐PPA) and polyvinylpyrrolidone (PVP) coated two‐channel surface acoustic wave (SAW) crystal gas sensor with a homemade computer interface for data acquisition and data processing was developed and employed to detect carbon disulfide (CS2) and methanol (CH3OH) vapors in polymer plants. The frequency of surface acoustic wave oscillator decreases due to the adsorption of gas molecules on the coated materials of the SAW sensor. Six coating materials (C60‐PPA, nafion, PPA, crytand [2,2], polyethene glycol and PVP) were used to adsorb and detect carbon disulfide and methanol gases. Adsorption of all the six coating materials to CS2 and CH3OH was found to be physical adsorption. The C60‐PPA coated SAW detector exhibited more sensitive to CS2 than the other coating materials. In contrast, the PVP coated SAW detector was more sensitive to CH3OH than the other coating materials. With the two‐channel SAW sensor, the C60‐PPA coated SAW showed a good detection limit of 0.4 ppm and good reproducibility with RSD of 3.37 % (n=10) for CS2. Similarly, the PVP coated SAW also showed a good detection limit of 0.05 ppm and good reproducibility, with RSD of 0.86 % (n=10) for CH3OH. The interference effect of other organic molecules on the SAW detection system was negligible, except for the irreversible adsorption of C60‐PPA to propylamine. The frequency signals from the two‐channel SAW sensor array C60‐PPA and PVP coatings were processed by a back‐propagation artificial neural network (BPN) and multiple regression analysis (MRA). Thus a two‐channel SAW sensor array with BPN and MRA has been successfully applied for the qualitative and quantitative analyses of CS2 and CH3OH in mixtures.  相似文献   

4.
We have developed a microfluidic device operating at a planar surface instead of a closed channel network. The fluid is transported in single droplets using surface acoustic waves (SAW) on a piezoelectric LiNbO(3) substrate. The surface of the piezo is chemically structured to induce high contact angles of the droplets or enclose areas where the liquid can wet the substrate. Combining the SAW technique with thin film resistance heaters, a biological analysis chip with integrated DNA amplification by PCR and hybridization was designed. To prevent evaporation of the PCR reagents at high temperatures the sample is enclosed in droplets of mineral oil. On this chip the SAW resolves dried primers, shifts the oil capped liquid between the two heaters and mixes during hybridization. The chip is able to perform a highly sensitive, fast and specific PCR with a volume as low as 200 nl. During the temperature cycles an online monitoring of the DNA concentration is feasible with an optical unit, providing a sensitivity of 0.1 ng. After PCR the product is moved to the second heater for the hybridization on a spotted DNA array. With our chip we were able to detect a single nucleotide polymorphism (SNP) responsible for the Leiden Factor V syndrome from human blood.  相似文献   

5.
This review describes recently emerging optical and microfluidic technologies suitable for point-of-care genetic analysis systems. Such systems must rapidly detect hundreds of mutations from biological samples with low DNA concentration. We review optical technologies delivering multiplex sensitivity and compatible with lab-on-chip integration for both tagged and non-tagged optical detection, identifying significant source and detector technology emerging from telecommunications technology. We highlight the potential for improved hybridization efficiency through careful microfluidic design and outline some novel enhancement approaches using target molecule confinement. Optimization of fluidic parameters such as flow rate, channel height and time facilitates enhanced hybridization efficiency and consequently detection performance as compared with conventional assay formats (e.g. microwell plates). We highlight lab-on-chip implementations with integrated microfluidic control for “sample-to-answer” systems where molecular biology protocols to realize detection of target DNA sequences from whole blood are required. We also review relevant technology approaches to optofluidic integration, and highlight the issue of biomolecule compatibility. Key areas in the development of an integrated optofluidic system for DNA hybridization are optical/fluidic integration and the impact on biomolecules immobilized within the system. A wide range of technology platforms have been advanced for detection, quantification and other forms of characterization of a range of biomolecules (e.g. RNA, DNA, protein and whole cell). Owing to the very different requirements for sample preparation, manipulation and detection of the different types of biomolecules, this review is focused primarily on DNA–DNA interactions in the context of point-of-care analysis systems.  相似文献   

6.
Surface acoustic wave biosensors: a review   总被引:2,自引:0,他引:2  
This review presents an overview of 20 years of worldwide development in the field of biosensors based on special types of surface acoustic wave (SAW) devices that permit the highly sensitive detection of biorelevant molecules in liquid media (such as water or aqueous buffer solutions). 1987 saw the first approaches, which used either horizontally polarized shear waves (HPSW) in a delay line configuration on lithium tantalate (LiTaO3) substrates or SAW resonator structures on quartz or LiTaO3 with periodic mass gratings. The latter are termed “surface transverse waves” (STW), and they have comparatively low attenuation values when operated in liquids. Later Love wave devices were developed, which used a film resonance effect to significantly reduce attenuation. All of these sensor approaches were accompanied by the development of appropriate sensing films. First attempts used simple layers of adsorbed antibodies. Later approaches used various types of covalently bound layers, for example those utilizing intermediate hydrogel layers. Recent approaches involve SAW biosensor devices inserted into compact systems with integrated fluidics for sample handling. To achieve this, the SAW biosensors can be embedded into micromachined polymer housings. Combining these two features will extend the system to create versatile biosensor arrays for generic lab use or for diagnostic purposes. SAW based biosensor immersed in a sample flow. Analyte molecules binding to the immobilized antibodies on the sensor surface will influence the velocity of the SAW and hence the output signal generated by the driving electronics.  相似文献   

7.
Novo P  Prazeres DM  Chu V  Conde JP 《Lab on a chip》2011,11(23):4063-4071
Microfluidic technology has the potential to decrease the time of analysis and the quantity of sample and reactants required in immunoassays, together with the potential of achieving high sensitivity, multiplexing, and portability. A lab-on-a-chip system was developed and optimized using optical and fluorescence microscopy. Primary antibodies are adsorbed onto the walls of a PDMS-based microchannel via microspotting. This probe antibody is then recognised using secondary FITC or HRP labelled antibodies responsible for providing fluorescence or chemiluminescent and colorimetric signals, respectively. The system incorporated a micron-sized thin-film hydrogenated amorphous silicon photodiode microfabricated on a glass substrate. The primary antibody spots in the PDMS-based microfluidic were precisely aligned with the photodiodes for the direct detection of the antibody-antigen molecular recognition reactions using chemiluminescence and colorimetry. The immunoassay takes ~30 min from assay to the integrated detection. The conditions for probe antibody microspotting and for the flow-through ELISA analysis in the microfluidic format with integrated detection were defined using antibody solutions with concentrations in the nM-μM range. Sequential colorimetric or chemiluminescence detection of specific antibody-antigen molecular recognition was quantitatively detected using the photodiode. Primary antibody surface densities down to 0.182 pmol cm(-2) were detected. Multiplex detection using different microspotted primary antibodies was demonstrated.  相似文献   

8.
In this work, we report Escherichia coli O157:H7 detection using antibody-immobilized capillary reactors, enzyme-linked immunosorbent assay (ELISA), and a biochip system. ELISA selective immunological method to detect pathogenic bacteria. ELISA is also directly adaptable to a miniature biochip system that utilizes conventional sample platforms such as polymer membranes and glass. The antibody-immobilized capillary reactor is a very attractive sample platform for ELISA because of its low cost, compactness, reuse, and ease of regeneration. Moreover, an array of capillary reactors can provide high-throughput ELISA. In this report, we describe the use of an array of antibody-immobilized capillary reactors for multiplex detection of E. coli O157:H7 in our miniature biochip system. Side-entry laser beam irradiation to an array of capillary reactors contributes significantly to miniaturized optical configuration for this biochip system. The detection limits of E. coli O157:H7 using the ELISA and Cy5 label-based immunoassays were determined to be 3 and 230 cells, respectively. This system shows capability to simultaneously monitor multifunctional immunoassay and high sensitive detection of E. coli O157:H7.  相似文献   

9.
We present a multiplex detection platform based on a microfluidic microparticle array to detect proteins and glucose in serum simultaneously. Multiplex detection of proteins and glucose was performed using biofunctionalized microparticles arrayed on gel-based microstructures integrated in microfluidics. The microparticles immobilized on these microstructures showed high stability under microfluidic flow conditions. With arrays of antibody-coated microbeads, microfluidic quantitative immunoassays for two protein tumor markers, human chorionic gonadotropin (hCG) and prostate specific antigen (PSA) were performed in serum samples with detection limits bellow the cut-off values for cancer diagnosis. Parallel to the immunoassays, quantitative enzymatic assays for glucose in the physiological concentration range were performed. Multiplex detection was achieved by using a spatially encoded microarray. By patterning antibody-coated microbeads and enzyme-containing microparticles on a novel mixed structure array, we successfully demonstrated simultaneous immunoassays (binding based assay) for proteins and an enzymatic assay (reaction kinetic based assay) for glucose. Our microparticle arrays could be potentially used for the detection of multiple categories of biomolecules (proteins, small metabolites and DNA) for clinical diagnostics and other biological applications.  相似文献   

10.
A hexaplex system based on multiplex polymerase chain reaction (PCR) coupled with liquid bead array was developed to assist detection of stacked genetically modified (GM) cotton event 281-24-236 × 3006-210-23 (Widestrike) expressing two kinds of endotoxin from Bacillus thuringiensis (Bt). The efficiency of this multiplex detection system was assessed. Specific primer sets for simultaneous detection of six targets in the stacked GM cotton event were constructed and used for the PCR assay. Each of the six targets was amplified, and the amplicons could be separated as discrete bands by agarose gel electrophoresis. A liquid bead array assay for the stacked GM cotton was performed using the hexaplex PCR products followed by hybridization between the biotinylated targets and anti-tagged microsphere beads. The hybridization products produced fluorescent signals that were detected by the Luminex system. Signal strengths were analyzed by their median fluorescent intensity values. Comparison of the assays showed that results from the liquid bead array using specific probes agreed with those from the PCR, and detection of the different target elements was found to be very specific with no cross-reaction. Therefore, the combination of hexaplex PCR and liquid bead array for detection of stacked GM events can be a useful and efficient system for screening and analyzing multiple transgenes for simultaneous qualitative analysis.  相似文献   

11.
Lu CJ  Zellers ET 《The Analyst》2002,127(8):1061-1068
A small multi-adsorbent preconcentration/focusing module for a portable GC with microsensor-array detector designed to determine complex mixtures of volatile and semi-volatile organic compounds encountered in indoor working environments is described. Candidate adsorbents were assessed on the basis of analyte thermal-desorption bandwidth and efficiency, chromatographic peak shape, and breakthrough volume against mixtures of organic compounds ranging over four orders of magnitude in vapor pressure. A capillary packed with just 12.3 mg of adsorbent material comprising Carbopack B (8 mg), Carbopack X (2.5 mg) and Carboxen 1000 (1.8 mg) provided the best tradeoff in operating variables, while maintaining sufficient capacity for a 1 L air sample containing a mixture of up to 43 compounds, each at 100 parts-per-billion, at an ambient relative humidity of up to 100%. On-column focusing and temperature programming were used to enhance chromatographic separations, and detection limits as low as 100 parts-per-trillion were achieved for a 1 L air sample using an integrated array of polymer-coated surface-acoustic-wave (SAW) sensors. Implications for field analysis of indoor air quality are emphasized.  相似文献   

12.
The recent outbreaks of a lethal E. coli strain in Germany have aroused renewed interest in developing rapid, specific and accurate systems for detecting and characterizing bacterial pathogens in suspected contaminated food and/or water supplies. To address this need, we have designed, fabricated and tested an integrated modular-based microfluidic system and the accompanying assay for the strain-specific identification of bacterial pathogens. The system can carry out the entire molecular processing pipeline in a single disposable fluidic cartridge and detect single nucleotide variations in selected genes to allow for the identification of the bacterial species, even its strain with high specificity. The unique aspect of this fluidic cartridge is its modular format with task-specific modules interconnected to a fluidic motherboard to permit the selection of the target material. In addition, to minimize the amount of finishing steps for assembling the fluidic cartridge, many of the functional components were produced during the polymer molding step used to create the fluidic network. The operation of the cartridge was provided by electronic, mechanical, optical and hydraulic controls located off-chip and packaged into a small footprint instrument (1 ft(3)). The fluidic cartridge was capable of performing cell enrichment, cell lysis, solid-phase extraction (SPE) of genomic DNA, continuous flow (CF) PCR, CF ligase detection reaction (LDR) and universal DNA array readout. The cartridge was comprised of modules situated on a fluidic motherboard; the motherboard was made from polycarbonate, PC, and used for cell lysis, SPE, CF PCR and CF LDR. The modules were task-specific units and performed universal zip-code array readout or affinity enrichment of the target cells with both made from poly(methylmethacrylate), PMMA. Two genes, uidA and sipB/C, were used to discriminate between E. coli and Salmonella, and evaluated as a model system. Results showed that the fluidic system could successfully identify bacteria in <40 min with minimal operator intervention and perform strain identification, even from a mixed population with the target of a minority. We further demonstrated the ability to analyze the E. coli O157:H7 strain from a waste-water sample using enrichment followed by genotyping.  相似文献   

13.
The diagnosis of infectious diseases in the Developing World is technologically challenging requiring complex biological assays with a high analytical performance, at minimal cost. By using an opto-acoustic immunoassay technology, integrating components commonly used in mobile phone technologies, including surface acoustic wave (SAW) transducers to provide pressure driven flow and a CMOS camera to enable lensfree detection technique, we demonstrate the potential to produce such an assay. To achieve this, antibody functionalised microparticles were manipulated on a low-cost disposable cartridge using the surface acoustic waves and were then detected optically. Our results show that the biomarker, interferon-γ, used for the diagnosis of diseases such as latent tuberculosis, can be detected at pM concentrations, within a few minutes (giving high sensitivity at a minimal cost).  相似文献   

14.
A simple, inexpensive yet highly selective colorimetric indicator-displacement assay array for the simultaneous detection and identification of three important biothiols at micromolar concentrations under physiological conditions and in real samples has been developed in this work. With use of an array composed of metal indicators and metal ions, clear differentiation among cysteine, homocysteine and glutathione was achieved. On the basis of the colour change of the array, quantification of each analyte was accomplished easily, and different biothiols were identified readily using standard chemometric approaches (hierarchical clustering analysis). Moreover, the colorimetric sensor array was not responsive to changes with 19 other natural amino acids, and it showed excellent reproducibility. Importantly, the sensor array developed was successfully applied to the determination and identification of the three biothiols in a real biological sample.
Figure
A simple, inexpensive yet highly selective colorimetric indicator-displacement assay array for the simultaneous detection and identification of three important biothiols was developed in this work  相似文献   

15.
This paper describes the first coupling of a commercial capillary HPLC system with a diode array spectrophotometric detector and a custom-built nuclear magnetic resonance (NMR) flow microprobe. The eluent from a 3-microm diameter C18 HPLC column is linked to a 500 MHz 1H-NMR microcoil probe with an observe volume of 1.1 microl. The separation and structurally-rich detection of a mixture of terpenoids under both isocratic and gradient solvent elution conditions is presented. The lowest limits of detection yet reported for capillary HPLC on-line measurement (i.e., 37 ng for alpha-pinene) are achieved with this system. The complementary nature of diode array and NMR detection allows stopped-flow data collection from analytes which would otherwise go unnoticed in continuous-flow NMR. Moreover, stopped-flow NMR data is presented for the detection of a trace (sub-nmol) impurity in the sample mixture. Since NMR signals degrade and shift during solvent gradients, flow injection analysis studies are conducted with injected solvent plugs differing in mobile phase composition. The NMR signal degradation accompanying these injections is largely due to the variance in chemical shift with the solvent composition rather than to changes in magnetic susceptibility of the solvent. Characterization of such effects enables the development of improved NMR probes for the coupling of capillary HPLC and NMR.  相似文献   

16.
Chromatographic methods for the determination of water- and fat-soluble vitamins in foods are reviewed. For each vitamin, sample preparation, detection problems and chromatographic conditions are presented and discussed. High-performance liquid chromatography (HPLC) is becoming a standard method in vitamin assay, especially for routine work. HPLC systems can be automated using in-line solid-phase extraction and column switchings, resulting in very sensitive methods, even when simple UV detection is employed.  相似文献   

17.
The present study involves an analysis of the performance of liquid chromatography (LC)-accurate radioisotope counting (ARC) and microplate scintillation counter (TopCount) technologies in drug metabolism studies. For the purpose of evaluating these systems, biological samples resulting from the metabolism of a radiolabeled [14C] compound, known as compound B, are analyzed using LC-ARC and TopCount under similar high-performance LC conditions. Counting efficiency is 83% for LC-ARC, 77% for TopCount, and linearity is R2 of 0.9998 versus 0.9984, respectively. The limit of detection for LC-ARC is 12 disintegrations per minute (dpm) with 1-min/fraction counting, yet for TopCount it is 8.7 dpm with 5-min/fraction counting. Under optimal conditions for each, the total run time of LC-ARC is approximately half that of TopCount. These results indicate that there is no significant difference between these two systems in terms of efficiency, linearity, and limit of detection. However, the LC-ARC system does not involve any manual operations, yet TopCount requires manual sample transfer and data import. This study shows that impressive progress has been made in the technology of radioisotope counting in drug metabolism using LC-ARC. This system enhances the resolution of radiochromatograms and is able to measure volatile metabolites that TopCount cannot detect at all. The ability to acquire mass spectra online is also a major advancement. The overall results suggest that the combination of LC-ARC with radioactivity detection and mass spectrometry has great potential as a powerful tool for radioisotope measurement in metabolite identification studies during drug discovery and development.  相似文献   

18.
Huang Y  Zhao S  Shi M  Liu J  Liang H 《Analytica chimica acta》2011,694(1-2):162-166
A microchip electrophoresis method with laser induced fluorescence detection was developed for the immunoassay of phenobarbital. The detection was based on the competitive immunoreaction between analyte phenobarbital and fluorescein isothiocyanate (FITC) labeled phenobarbital with a limited amount of antibody. The assay was developed by varying the borate concentration, buffer pH, separation voltage, and incubation time. A running buffer system containing 35 mM borate and 15 mM sodium dodecyl sulfate (pH 9.5), and 2800 V separation voltage provided analysis conditions for a high-resolution, sensitive, and repeatable assay of phenobarbital. Free FITC-labeled phenobarbital and immunocomplex were separated within 30s. The calibration curve for phenobarbital had a detection limit of 3.4 nM and a range of 8.6-860.0 nM. The assay could be used to determine the phenobarbital plasma concentration in clinical plasma sample.  相似文献   

19.
A novel surface acoustic wave-interdigitated array electrode (SAW-IDA) ammonia gas sensor is proposed. A gas-permeable membrane is employed to separate the buffer solution in the inner cell of the gas-sensing probe from the sample solution in the detection cell. The response of the IDA conductive electrodes is based on the impedance change of the buffer solution during ammonia adsorption. Therefore, this gas sensor overcomes the influence of water vapour in the conventional film-coated SAW gas sensor and can be used for the detection of gases in aqueous solutions. The ammonia sensor exhibits a favourable frequency response to 5 × 10−7−1 × 10−3 mol/1 ammonia. The optimal buffer composition and probe parameters have been determined. Dynamic range, response time, selectivity, and temperature drift are discussed. The ammonia sensor was also applied to the determination of serum ammonia. Results were in good agreement with those from the conventional enzymatic-spectro-photometric method.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号