共查询到20条相似文献,搜索用时 31 毫秒
1.
A new molecularly imprinted polymer for selective extraction of cotinine from urine samples by solid-phase extraction 总被引:1,自引:0,他引:1
Cotinine, the main metabolite of nicotine in human body, is widely used as a biomarker for assessment of direct or passive
exposure to tobacco smoke. A method for molecularly imprinted solid-phase extraction (MISPE) of cotinine from human urine
has been investigated. The molecularly imprinted polymer (MIP) with good selectivity and affinity for cotinine was synthesized
using cotinine as the template molecule, methacrylic acid as the functional monomer, and ethylene glycol dimethacrylate as
the cross-linker. The imprinted polymer was evaluated for use as a SPE sorbent, in tests with aqueous standards, by comparing
recovery data obtained using the imprinted form of the polymer and a non-imprinted form (NIP). Extraction from the aqueous
solutions resulted in more than 80% recovery. A range of linearity for cotinine between 0.05 and 5 μg mL−1 was obtained by loading 1 mL blank urine samples spiked with cotinine at different concentrations in acetate buffer of pH
9.0, and by using double basic washing and acidic elution. The intra-day coefficient of variation (CV) was below 7% and inter-day
CV was below 10%. This investigation has provided a reliable MISPE–HPLC method for determination of cotinine in human urine
from both active smokers and passive smokers.
Figure 相似文献
2.
In this paper, a novel format for selective solid-phase extraction based on a molecularly imprinted polymer (MIP) is described. A small amount of MIP has been synthesized within the pores of commercial polyethylene (PE) frits and attached to its surface using benzophenone (BP), a photo-initiator capable to start the polymerisation from the surface of the support material. Key properties affecting the obtainment of a proper polymeric layer, such as polymerisation time and kind of cross-linker were optimised. The developed imprinted material has been applied as a selective sorbent for cleaning extracts of thiabendazole (TBZ), as model compound, from citrus samples. The use of different solvents for loading the analyte in the imprinted frits was investigated, as well as the binding capacity of the imprinted polymer. Imprinted frits showed good selectivity when loads were performed using toluene and a linear relationship was obtained for the target analyte up to 1000 ng of loaded analyte. Prepared composite material was applied to the SPE of TBZ in real samples extracts, showing an impressive clean-up ability. Calibrations showed good linearity in the concentration range of 0.05-5.00 μg g(-1), referred to the original solid sample, and the regression coefficients obtained were greater than 0.996. The calculated detection limit was 0.016 μg g(-1), low enough to satisfactory analysis of TBZ in real samples. RSDs at different spiking levels ranged below 15% in all the cases and imprinted frits were reusable without loss in their performance. 相似文献
3.
A new gallium (Ga(III)) ion-imprinted multi-walled carbon nanotubes (CNTs) composite sorbent was synthesized by a surface imprinting technique. The Ga(III) ion-imprinted/multi-walled carbon nanotubes (Ga(III)-imprinted/CNTs) sorbent was characterized by Fourier transform infrared (FT-IR), X-ray diffraction (XRD), nitrogen adsorption experiment, static adsorption experiment, and solid-phase extraction (SPE) experiment. The effects of sample volume, sample pH, washing and elution conditions on the extraction of Ga(III) ion from real sample were studied in detail. The imprinted sorbent offered a fast kinetics for the adsorption of Ga(III). The maximum static adsorption capacity of the imprinted sorbent towards was 58.8 μmol g−1. The largest selectivity coefficient for Ga(III) in the presence of Al(III) was over 57.3. Compared with non-imprinted sorbent, the imprinted sorbent showed good imprinting effect for Ga(III) ion, the imprinting factor (α) was 2.6, the selectivity factor (β) was 2.4 and 2.9 for Al(III) and Zn(II), respectively. The developed imprinted SPE method was applied successfully to the detection of trace Ga(III) ion in fly ash samples with satisfactory results. 相似文献
4.
Beltran A Marcé RM Cormack PA Sherrington DC Borrull F 《Journal of separation science》2008,31(15):2868-2874
In this paper we describe, for the first time, a molecularly imprinted polymer (MIP) for the antibiotic amoxicillin (AMX), synthesised by a noncovalent molecular imprinting approach and used to extract AMX selectively from urine samples. The MIP was applied as a molecularly selective sorbent in molecularly imprinted SPE (MISPE) in an off-line mode, where it showed useful cross-selectivity for a structurally related antibiotic, cephalexin (CPX). By using a MISPE protocol, the MIP was able to selectively extract both AMX and CFX from 5 mL of water spiked with 10 mg/L with recoveries of 75 and 78% for AMX and CFX, respectively. When applied to real samples (urine) at clinically relevant concentrations, recoveries from 2 mL of human urine spiked with 20 mg/L decreased slightly to 65 and 63% for AMX and CFX, respectively. To demonstrate further the selectivity of the MIP obtained, a comparison with commercially available SPE cartridges was performed. Improvements in the retention of both AMX and CFX on the MIP were obtained relative to the commercially available cartridges, and the MISPE extracts were considerably cleaner, due to molecularly selective analyte binding by the MIP. 相似文献
5.
A triazolam-imprinted silica microsphere was prepared by combining a surface molecular-imprinting technique with the sol-gel process. The results illustrate that the triazolam-imprinted silica microspheres provided using γ-aminopropyltriethoxysilane and phenyltrimethoxysilane as monomers exhibited higher selectivity than those provided from γ-aminopropyltriethoxysilane and methyltriethoxysilane. In addition, the optimum affinity occurred when the molar ratio of γ-aminopropyltriethoxysilane, phenyltrimethoxysilane, and the template molecule was 4.2:4.7:0.6. Retention factor (k) and imprinting factor (IF) of triazolam on the imprinted and non-imprinted silica microsphere columns were characterized using high performance liquid chromatography (HPLC) with different mobile phases including methanol, acetonitrile, and water solutions. The molecular selectivity of the imprinted silica microspheres was also evaluated for triazolam and its analogue compounds in various mobile phases. The better results indicated that k and IF of triazolam on the imprinted silica microsphere column were 2.1 and 35, respectively, when using methanol/water (1/1, v/v) as the mobile phase. Finally, the imprinted silica was applied as a sorbent in solid-phase extraction (SPE), to selectively extract triazolam and its metabolite, α-hydroxytriazolam, from human urine samples. The limits of detection (LOD) for triazolam and α-hydroxytriazolam in urine samples were 30 ± 0.21 ng mL−1 and 33 ± 0.26 ng mL−1, respectively. 相似文献
6.
To obtain a highly selective material for the antibiotic chloramphenicol, which has several harmful side effects in humans,
different molecularly imprinted polymers (MIPs) were prepared. In order to avoid a major traditional drawback associated with
MIPs of residual template bleeding, molecules that are structurally related to chloramphenicol were used as templates for
polymer synthesis. Chromatographic evaluation indicated that the employed template imparted a significant influence on the
recognition properties of the corresponding polymer. A strong retention of chloramphenicol under nonpolar elution conditions
(k = 68.03, IF = 17.72) and under aqueous elution conditions (k = 92.44, IF = 1.35) was achieved. After chromatographic evaluation, the MIP was utilized as the recognition sorbent in a
solid-phase extraction to determine chloramphenicol using either an organic or aqueous washing solvent. Recoveries of nearly
100% from the chloramphenicol standard solution and nearly 90% from honey samples spiked with chloramphenicol were attained.
Furthermore, the applicability of the MIP for sample cleanup was demonstrated. 相似文献
7.
Lars I. Andersson Johan Henriksson Lars-Inge Olsson Mohamed Abdel-Rehim 《Analytica chimica acta》2004,526(2):147-154
Molecular imprints selective for a homologous series of local anaesthetics, including bupivacaine, ropivacaine and mepivacaine, were prepared and the resultant polymers were used for solid-phase extraction of human plasma. The template was a structural analogue, pentycaine, which was imprinted in methacrylic acid-ethylene glycol dimethacrylate copolymers. Equilibrium ligand binding experiments using radiolabelled bupivacaine were performed to characterize the imprinted polymers, as well as to identify optimal conditions for selective extraction of plasma samples. Dilution of the plasma prior to extraction with citrate buffer pH 5.0 containing ethanol and Tween 20 was found optimal for selective imprint-analyte binding, and for reduction of non-specific adsorption of lipophilic contaminants to the hydrophobic MIP surface. Wash steps using 20% methanol in water followed by a solvent switch to 10% ethanol in acetonitrile removed contaminants and strengthened the selective imprint-analyte binding. Elution under basic conditions using triethylamine-water-acetonitrile mixtures recovered bupivacaine in 89% yield with superior selectivity over elution under acidic conditions. The final protocol extracted trace levels of ropivacaine and bupivacaine from human plasma and allowed determination of bupivacaine in the range of 3.9-500 nmol L−1 and ropivacaine in the range of 7.8-500 nmol L−1 with inter-assay accuracies of 94-99 and 95-104%, respectively. This present investigation provides an improved understanding of approaches available for optimization of protocols for molecular-imprint based solid-phase extraction of plasma samples. 相似文献
8.
Beltran A Caro E Marcé RM Cormack PA Sherrington DC Borrull F 《Analytica chimica acta》2007,597(1):6-11
A molecularly imprinted polymer (MIP) designed to enable the selective extraction of carbamazepine (CBZ) from effluent wastewater and urine samples has been synthesised using a non-covalent molecular imprinting approach. The MIP was evaluated chromatographically in the first instance and its affinity for CBZ also confirmed by solid-phase extraction (SPE). The optimal conditions for SPE consisted of conditioning of the cartridge using acidified water purified from a Milli-Q system, loading of the sample under basic aqueous conditions, clean-up using acetonitrile and elution with methanol. The attractive molecular recognition properties of the MIP gave rise to good CBZ recoveries (80%) when 100 mL of effluent water spiked with 1 μg L−1 was percolated through the polymer. For urine samples, 2 mL samples spiked with 2.5 μg L−1 CBZ were extracted with a recovery of 65%. For urine, the linear range was 0.05-24 mg L−1, the limit of detection was 25 μg L−1 and precision, expressed as relative standard deviation at 0.5 mg L−1 (n = 3), was 3.1% and 12.6% for repeatability and reproducibility between days, respectively. 相似文献
9.
Eduardo Costa Figueiredo Maria Elisa Pereira Bastos de Siqueira 《Analytica chimica acta》2009,635(1):102-3757
This work describes an on-line molecularly imprinted solid-phase extraction (MISPE) method for spectrophotometric determination of nicotine in urine samples of smokers. This method is based on manganese (VII) to manganese (VI) reduction in an alkaline medium, promoted by nicotine. Two wash solutions (1:4 (v/v) acetonitrile:sodium hydroxide - pH 11.4, and nitric acid - pH 2.5) were employed to circumvent interferences. Aqueous solutions containing nicotine plus different possible concomitants (cotinine, anabasine, norcotinine and caffeine) were tested individually. The analytical calibration curve was prepared in urine samples collected from non-smokers and spiked with nicotine standard from 1.1 to 60 μmol L−1 (r2 > 0.998). The limit of quantification and the analytical frequency were 1.1 μmol L−1 and 11 h−1, respectively. The precision, evaluated using 3, 10 and 30 μmol L−1 nicotine in urine, was 10, 10 and 4% (intra-day precision) and 12, 13 and 5% (inter-day precision), respectively. Accuracy was checked through high performance liquid chromatography and the results did not present significant differences at the 95% confidence level according to the Student's t-test. 相似文献
10.
This paper reports the preparation of metsulfuron-methyl (MSM) imprinted polymer layer-coated silica nanoparticles toward analysis of trace sulfonylurea herbicides in complicated matrices. To induce the selective occurrence of surface polymerization, the polymerizable double bonds were first grafted at the surface of silica nanoparticles by the silylation. Afterwards, the MSM templates were imprinted into the polymer-coating layer through the interaction with functional monomers. The programmed heating led to the formation of uniform MSM-imprinted polymer layer with controllable thickness, and further improved the reproducibility of rebinding capacity. After removal of templates, recognition sites of MSM were exposed in the polymer layers. As a result, the maximum rebinding capacity was achieved with the use of optimal grafting ratio. There was also evidence indicating that the MSM-imprinted polymer nanoparticles compared with nonimprinted polymer nanoparticles had a higher selectivity and affinity to four structure-like sulfonylurea herbicides. Moreover, using the imprinted particles as dispersive solid-phase extraction (DSPE) materials, the recoveries of four sulfonylurea herbicides determined by high-performance liquid chromatography (HPLC) were 80.2-99.5%, 83.8-102.4%, 77.8-93.3%, and 73.8-110.8% in the spiked soil, rice, soybean, and corn samples, respectively. These results show the possibility that the highly selective separation and enrichment of trace sulfonylurea herbicides from soil and crop samples can be achieved by the molecular imprinting modification at the surface of silica nanoparticles. 相似文献
11.
A highly selective imprinted amino-functionalized silica gel sorbent was prepared by combining a surface molecular imprinting technique with a sol-gel process for on-line solid-phase extraction-HPLC determination of trace pentachlorophenol (PCP) in water samples. The PCP-imprinted amino-functionalized silica sorbent was characterized by FT-IR, SEM, nitrogen adsorption and the static adsorption experiments. The imprinted functionalized silica gel sorbent exhibited high selectivity and offered a fast kinetics for the adsorption and desorption of PCP. The prepared sorbent was shown to be promising for on-line solid-phase extraction for HPLC determination of trace levels of PCP in environmental samples. With a sample loading flow rate of 5 ml min(-1) for 2 min, an enhancement factor of 670 and a detection limit (S/N = 3) of 6 ng l(-1) were achieved at a sample throughput of five samples h(-1). The precision (RSD) for nine replicate on-line sorbent extractions of 10 microgl(-1) PCP was 3.8%. The sorbent also offered good linearity (r = 0.9997) for on-line solid-phase extraction of trace levels of PCP. The method was applied to the determination of PCP in local lake water, river water and wastewater samples. 相似文献
12.
分子印迹固相萃取牛奶中甲胺磷 总被引:4,自引:0,他引:4
以甲胺磷为印迹分子、α-甲基丙烯酸为功能单体及三羟甲基丙烷三丙烯酸酯为交联剂,通过悬浮聚合法制备甲胺磷分子印迹聚合物(MIP)微球,并用该聚合物进行了牛奶中甲胺磷残留的固相萃取研究.静态吸附实验表明,在结构相似物乙酰甲胺磷和水胺硫磷为竞争底物存在下,MIP对甲胺磷有良好的吸附识别能力.在优化条件下,印迹分子的固相萃取回收率达96.4%,能够用于甲胺磷的富集,而空白聚合物却不具备这样的特性.当实际牛奶样品中甲胺磷、乙酰甲胺磷和水胺硫磷加标水平为100μg/kg时,甲胺磷回收率达87.4%,乙酰甲胺磷和水胺硫磷的回收率低于15%.结果表明分子印迹固相萃取对甲胺磷有很好的专一选择性,且回收率能够满足农药残留分析要求.在相同实验条件下,与C18固相萃取柱进行比较,分子印迹固相萃取的选择性及样品净化能力优势明显. 相似文献
13.
Limin He Yijuan Su Yaqiu Zheng Xianhui Huang Li Wu Yahong Liu Zhenling Zeng Zhangliu Chen 《Journal of chromatography. A》2009,1216(34):6196-6203
A water compatible molecularly imprinted polymer (MIP) using cyromazine as a mimic template, methacrylic acid as the functional polymer and ethylene glycol dimethacrylate as the cross-linker was synthesized and used to extract melamine from feed and milk samples via a molecularly imprinted solid-phase extraction (MISPE) protocol. Optimum retention of melamine on the MISPE cartridge was achieved using methanol, and the interferences in the samples were effectively washed out. The binding capacity of the polymer toward melamine was found to be about 500 μg of melamine/g of polymer. The recoveries of 2 μg and 20 μg melamine standard spiked into water extract of blank feeds and milk samples were between 83.4% and 103%, with relative standard deviation <5.6%. The cyromazine-MIP demonstrated high cross-reactivity for melamine and low affinity to cyanuric acid. The ionic bond interaction was regarded as the main factors that dominated the retention of the melamine on the MISPE cartridge. 相似文献
14.
Six molecularly imprinted polymers (MIPs) of erythromycin (ERY) were prepared by noncovalent bulk polymerization using methacrylic
acid (MAA) as the functional monomer. On the basis of binding analysis, the MIPs with 1:2 optimum ratio of template to MAA
were selected for subsequent scanning electron microscopy and Brunauer–Emmett–Teller analyses, which indicated that the MIPs
had more convergent porous structures than the nonimprinted polymers. The equilibrium binding experiments showed that the
binding sites of MIPs were heterogeneous, with two dissociation constants of 0.005 and 0.63 mg mL−1, respectively. Furthermore, the performance of the MIPs as solid-phase extraction (SPE) sorbents was evaluated, and the selectivity
analysis showed that the MIPs could recognize ERY with moderate cross-reactivity for other macrolides. The overall investigation
of molecularly imprinted SPE for cleanup and enrichment of the ERY in pig muscle and tap water confirmed the feasibility of
utilizing the MIPs obtained as specific SPE sorbents for ERY extraction in real samples.
Figure Schematic diagram of the preparation and application of the erythromycin imprinted molecularly imprinted polymers
Suquan Song and Aibo Wu contributed equally to this work. 相似文献
15.
Molecularly imprinted solid-phase extraction of cocaine metabolites from aqueous samples 总被引:1,自引:0,他引:1
Cocaine is a well-known drug of abuse which, when ingested nasally or by smoking, undergoes a number of biotransformation and degradation reactions. In the present work, a synthetic analogue of the cocaine metabolite benzoylecgonine was prepared and used as a template molecule in the preparation of a series of molecularly imprinted polymers (MIPs). Molecularly imprinted solid-phase extraction (MISPE) conditions were established under which benzoylecgonine in aqueous samples could be selectively extracted and quantified at clinically relevant concentrations (μg/ml). Under optimised MISPE conditions, recoveries of analyte were high (>70%) and excellent discrimination between imprinted and non-imprinted materials observed. 相似文献
16.
Development of a selective molecularly imprinted polymer-based solid-phase extraction for indomethacin from water samples 总被引:1,自引:0,他引:1
A selective molecularly imprinted solid-phase extraction (MISPE) for indomethacin (IDM) from water samples was developed.
Using IDM as template molecule, acrylamide (AM) or methacrylic acid (MAA) as functional monomer, ethylene dimethacrylate (EDMA)
as crosslinker, and bulk or suspension polymerization as the synthetic method, three molecularly imprinted polymers (MIPs)
were synthesized and characterized with a rebinding experiment. It was found that the MIP of AM-EDMA produced by bulk polymerization
showed the highest binding capacity for IDM, and so it was chosen for subsequent experiments, such as those testing the selectivity
and recognition binding sites. Scatchard analysis revealed that at least two kinds of binding sites formed in the MIP, with
the dissociation constants of 7.8 μmol L−1 and 127.2 μmol L−1, respectively. Besides IDM, three structurally related compounds — acemetacin, oxaprozin and ibuprofen — were employed for
selectivity tests. It was observed that the MIP exhibited the highest selective rebinding to IDM. Accordingly, the MIP was
used as a solid-phase extraction sorbent for the extraction and enrichment of IDM in water samples. The extraction conditions
of the MISPE column for IDM were optimized to be: chloroform or water as loading solvent, chloroform with 20% acetonitrile
as washing solution, and methanol as eluting solvent. Water samples with or without spiking were extracted by the MISPE column
and analyzed by HPLC. No detectable IDM was observed in tap water and the content of IDM in a river water sample was found
to be 1.8 ng mL−1. The extraction efficiencies of the MISPE column for IDM in spiked tap and river water were acceptable (87.2% and 83.5%,
respectively), demonstrating the feasibility of the prepared MIP for IDM extraction.
Figure Molecularly imprinted polymer-based solid-phase extraction for indomethacin 相似文献
17.
In this work, a novel method is described for the determination of bromhexine in biological fluids using molecularly imprinted solid-phase extraction as the sample cleanup technique combined with high performance liquid chromatography (HPLC). The water-compatible molecularly imprinted polymers (MIPs) were prepared using methacrylic acid as functional monomer, ethylene glycol dimethacrylate as cross-linker, chloroform as porogen and bromhexine as the template molecule. The novel imprinted polymer was used as a solid-phase extraction sorbent for the extraction of bromhexine from human serum and urine. Various parameters affecting the extraction efficiency of the polymer have been evaluated. The optimal conditions for molecularly imprinted solid-phase extraction (MISPE) consisted of conditioning 1 mL methanol and 1 mL of deionized water at neutral pH, loading of 5 mL of the water sample (25 μg L−1) at pH 6.0, washing using 2 mL acetonitrile/acetone (1/4, v/v) and elution with 3× 1 mL methanol/acetic acid (10/1, v/v). The MIP selectivity was evaluated by checking several substances with similar molecular structures to that of bromhexine. Results from the HPLC analyses showed that the calibration curve of bromhexine using MIP from human serum and urine is linear in the ranges of 0.5-100 and 1.5-100 μg L−1 with good precisions (3.3% and 2.8% for 5.0 μg L−1), respectively. The recoveries for serum and urine samples were higher than 92%. 相似文献
18.
《Comptes Rendus Chimie》2017,20(5):585-591
Ketoprofen is a nonsteroidal anti-inflammatory drug widely consumed by humans as it possesses analgesic activities. A selective molecularly imprinted polymer (MIP) for ketoprofen was synthesized and applied as a solid-phase extraction sorbent. MIP was synthesized using 2-vinylpyridine, ethylene glycol dimethacrylate, 1,1′-azobis(cyclohexanecarbonitrile), toluene/acetonitrile (9:1, v/v), and ketoprofen as a functional monomer, cross-linker, initiator, porogenic mixture, and template, respectively. The polymerization was performed at 60 °C for 16 h, and thereafter the temperature was increased to 80 °C for 24 h to achieve a solid monolith polymer. Nonimprinted polymer was synthesized in a similar manner with the omission of ketoprofen. Characterization with thermogravimetric analysis and X-ray diffraction showed that the synthesized polymers were thermally stable and amorphous. Solid-phase extraction cartridges packed with MIP were used with high-performance liquid chromatography for quantitative analysis of ketoprofen in wastewater. The analytical method gave detection limits of 0.23, 0.17, and 0.09 μg/L in wastewater influent, effluent, and deionized water, respectively. The recovery for the wastewater influent and effluent spiked with 5 μg/L of ketoprofen was 68%, whereas 114% was obtained for deionized water. The concentrations of ketoprofen in the influent and effluent samples were in the ranges of 22.5–34.0 and 1.14–5.33 μg/L, respectively. Overall, the analytical method for the analysis of ketoprofen in wastewater was rapid, affordable, accurate, precise, sensitive, and selective. 相似文献
19.
20.
Application of a magnetic molecularly imprinted polymer for the selective extraction and trace detection of lamotrigine in urine and plasma samples 下载免费PDF全文
Mohammad Behbahani Saman Bagheri Mostafa M. Amini Hamid Sadeghi Abandansari Hamid Reza Moazami Akbar Bagheri 《Journal of separation science》2014,37(13):1610-1616
Magnetic molecularly imprinted polymers have been synthesized for the selective preconcentration and trace determination of lamotrigine (LTG) in urine and plasma samples. The magnetic nanoparticles were modified by tetraethyl orthosilicate and 3‐methacryloxypropyl trimethoxysilane before imprinting. The magnetic molecularly imprinted polymers were prepared via surface molecular imprinting technique, using Fe3O4 as a magnetic component, LTG as template molecule, methacrylic acid as a functional monomer, ethylene glycol dimethacrylate as a cross‐linker, and 2,2′‐azobisisobutyronitrile as a radical initiator in methanol/acetonitrile (50:50, v/v) as the porogen. The obtained sorbent was characterized using scanning electron microscopy, Fourier‐transform infrared spectroscopy, X‐ray diffraction, and thermal analysis. Separation of the sorbent from the sample solution was simply achieved by applying an external magnetic field. Determination of the extracted drug was performed by high‐performance liquid chromatography with UV detection. Under the optimum extraction conditions, the method detection limits were 0.7 μg/L (based on S/N of 3) for urine samples and 0.5 μg/L for plasma samples. A linear dynamic range of 1–1000 μg/L was obtained for LTF in plasma and urine samples. Finally, the applicability of the proposed method was evaluated by extraction and determination of LTG in urine and plasma samples. 相似文献