A new compact, aluminum electrothermal vaporization cell was constructed for inductively coupled plasma-optical emission spectrometry analysis. This cell is compact enough to fit within the space occupied by the spray chamber and fits directly to the quartz torch without extraneous tubing through the use of a simple Compression fitting. Sample volumes as low as 10 μL were analyzed with an automated control program for efficient vaporization. Twelve elements were analyzed utilizing a time resolved acquisition method so that real-time data could be generated over a period of 10 s with an average improvement factor of 14 for elements over a wavelength range of 193–445 nm.  相似文献   

2.
水质中硫酸盐的测定方法很多,但对于成分复杂且盐分很高的矿山水样,传统方法操作繁琐且不环保,本文建立了等离子体发射光谱法测定矿山水样中硫酸盐的方法,样品采用硝酸和盐酸进行加热消解后既可去除硫化物,降低水质的黏度,又可实现多元素同时测定。该方法检出限为0.03mg/L,相对标准偏差为0.1~0.4%(n=6),方法具有方便,快捷,检出限低,精密度、准确度高且线性范围广的优点。  相似文献   

3.
A novel method for the determination of trace elements in microliter samples using the tantalum filament electrothermal vaporization/low-pressure inductively coupled plasma (ETV/LP-ICP) atomic emission spectrometry has been developed. An improved tantalum filament ETV was directly coupled with LP-ICP system for efficient vaporization of microliter samples and further quantitative analysis. The experimental parameters including ETV current, rf power and mass flow rate of argon carrier gas were optimized using the copper emission signal produced by 5 μl of standard solution (5 μg/ml). Under the optimized condition, the analytical performances including linearity, precision and detection limit for the developed system were investigated. Absolute detection limits in the range of 22–391 pg for selected eight elements (Fe, Cu, Cr, Mn, Pb, K, Zn and Mg) were obtained with satisfactory precision (<8.9% RSD). The feasibility of the developed system has been demonstrated by analyzing wheat gluten NIST standard sample.  相似文献   

4.
In this study, a simple and efficient method of ligandless-ultrasound-assisted emulsification microextraction (LL-USAEME) followed by inductively coupled plasma-optical emission spectrometry (ICP-OES) has been developed for simultaneous extraction, preconcentration and determination of manganese, cadmium, cobalt and nickel in water samples. In the proposed approach, tetrachloroethylene was selected as extraction solvent. The effect of important experimental factors such as volume of extraction solvent, pH, sonication time, salt concentration, and temperature was investigated by using a fractional factorial design (25?1) to identify important factors and their interactions. In the next step, a Box-Behnken design (BBD) was applied for optimisation of significant factors. The obtained optimal conditions were: 30?µL for extraction solvent, 12 for pH, 5?min for sonication time, and 5% w/v for salt concentration. The limits of detections (LODs) for Cd(II), Co(II), Mn(II) and Ni(II) were 0.20, 0.13, 0.21 and 0.28?µg?L?1, respectively. Relative standard deviations (RSD, C?=?200.0?µg?L?1, n?=?9) were between 3.4–7.5% and the calibration graphs were linear in the range of 0.25 to 1000.0?µg?L?1 for Mn, 0.5–1000.0?µg?L?1 for Co and Ni and 1.0–250.0?µg?L?1 for Cd. The determination coefficients (R 2) of the calibration curves for the analytes were in the range of 0.993 to 0.999. The proposed method was validated by using two certified reference materials, and also the method was applied successfully for the determination of heavy metals in different real water samples.  相似文献   

5.
A procedure based on electrothermal evaporation (ETV) and inductively coupled plasma atomic emission spectrometry (ICP-OES) for the determination of trace impurities in Al2O3 powders without any sample pretreatment is presented. With the aid of matrix modifier the transport and the evaporation efficiency for refractory compounds could be increased by forming halides with a lower boiling point. As calibration is still a problem in direct solid sample analysis, different calibration approaches including the use of certified reference materials from NIST and standard addition of aqueous solutions of analytes were discussed. The accuracy obtained with calibration and with the standard addition method was shown up for the elements Ca, Fe, Ga, Mg, Mn, Na, Ni and V for the case of Al2O3 NIST standard reference material (SRM 699). The ETV–ICP-OES method was used for the analysis of Al2O3 powders with impurities in the low μg/g range and the results for the elements Ca, Fe, Ga, Mg, Mn, Na, Ni and V obtained with evaporation of discrete powder amounts with ETV–ICP-OES and slurry evaporation under the use of ultrasonic homogenization during the sampling and ETV–ICP-MS were shown to be in a good agreement.  相似文献   

6.
提出了以二乙基二硫代磷酸(DDTP)为化学改进剂,低温电热蒸发ICP-OES法检测环境样品中的钴和镍,对影响金属螯合物形成及其蒸发条件进行了考察与优化。试验结果表明,在pH〉4.5,DDTP质量浓度为8.0g/L的条件下,试剂DDTP可与钴(Ⅱ),镍(Ⅱ)形成稳定的螯合物。并以螯合物的气态形式从石墨炉中。定量蒸发和传输至等离子体中,用于ETV-ICP-OES检测。钴(Ⅱ)和镍(Ⅱ)的检出限分别为19.6和17.3μg/L,与常规的ETV-ICP-OES法相比待测元素的蒸发温度降低了1200℃左右。方法已用于土壤和水系沉积物标准样品中钴和镍的检测。  相似文献   

7.
Pierre Masson 《Talanta》2007,71(3):1399-1404
The present work demonstrates the capability of electrothermal vaporization (ETV) to become an important tool of solid sample introduction in ICP-AES for plant sample analysis. Direct determination of Al, Ca, Fe, K, Mg, Mn, Na and Zn was investigated in powdered plant samples. Obtaining good results for major elements in plant samples was governed by some special operating conditions. The sensitivity of the method necessitated the use of ICP in radial view configuration. The behavior of elements during vaporization was studied between 500 and 2600 °C. External calibration was carried out using solid external (cellulose) spiked with aqueous standard solutions. However, performances of the analytical method were found dependent of argon flow rates. Analytical accuracy of the method was tested in three reference materials. Analytical results agreed with certified values when cellulose was used in calibration. However, K could not be determined because of excessive sensitivity. Without cellulose, it was found that Fe results were underestimated and Zn results overestimated. Relative standard deviations varied from 3 to 23%. Limits of detection varied from 1 to 80 ng g−1 from one element to the other for a typical mass sample of 2 mg.  相似文献   

8.
A novel method for the speciation of chromium(III) and chromium(VI) by in situ separation and sequential determination with electrothermal vaporization-inductively coupled plasma-atomic emission spectrometry (ETV-ICP-AES) was developed. The reaction conditions between Cr(III) and 8-hydroxyquinoline (8-Ox) and the vaporization behavior of the chelate formed were investigated in detail. It was found that the Cr(III)-8-Ox chelate could be formed at room temperature and vaporized from graphite furnace under controlled experimental conditions, therefore, an in situ separation of Cr(III) from Cr(VI) was achieved. The retained Cr(VI) in graphite tube was then determined by using fluorination vaporization ETV-ICP-AES with PTFE slurry as chemical modifier. Under optimum experimental conditions, the detection limits for Cr(III) and Cr(VI) are 8.6 ng/ml and 11.3 ng/ml, and the relative standard deviations (R.S.D.s) are 3.8% and 4.1% (c=0.1 μg/ml, n=6), respectively. The linear ranges of the calibration curve for both Cr(III) and Cr(VI) covered three orders of magnitude. The proposed method has been applied to the speciation of Cr(III) and Cr(VI) in water samples with the satisfactory results.  相似文献   

9.
Eva María Seco-Gesto 《Talanta》2007,72(3):1178-1185
Studies on the application of a short microwave irradiation cycle and the use of diluted acids to extract trace elements from raft mussel samples were developed. Multi-element determinations (Al, Ba, Cd, Cr, Cu, Fe, Mn, Pb, Sn, V and Zn) were carried out by inductively coupled plasma-optical emission spectrometry (ICP-OES). Parameters such as acid/oxidizing reagents (diluted nitric acid, hydrochloric acid and hydrogen peroxide) concentrations, acid/oxidizing solution volume, temperature, ramp time and hold time for the microwave heating were simultaneously studied by using an experimental design approach. The optimum conditions have showed the sample pre-treatment of 10 mussel samples to less than 3.0 min when a microwave power of 600 W and a controlled temperature of 65 °C were used. This time (hold time plus ramp time) is quite shorter than those reported for conventional microwave-assisted acid digestion procedures. Since temperature inside the reactor is not high, the venting time can be shorted to 15 min. In addition, the concentration of acid/oxidizing reagents needed to complete the acid leaching (2.5 M, 3.0 M and 0.5 % (m/v) for nitric acid, hydrochloric acid and hydrogen peroxide, respectively) is lower than the required concentration for a conventional microwave-assisted acid digestion (concentrated acids). The proposed method has showed a good repeatability of the overall method, and relative standard deviations between 11 and 2% were reached for 12 replicate microwave-assisted acid leaching and ICP-OES measurements. The method was finally validated by analyzing TORT-1 and GBW-08571 certified reference materials and it was successfully applied to fast multi-element determinations in several raft mussel samples.  相似文献   

10.
Two digestion-free methods for trace analysis of boron nitride based on graphite furnace atomic absorption spectrometry (GFAAS) and electrothermal vaporization inductively coupled plasma spectrometry optical emission (ETV-ICP-OES) using direct solid sampling have been developed and applied to the determination of Al, Ca, Cr, Cu, Fe, Mg, Mn, Si, Ti and Zr in four boron nitride materials in concentration intervals of 1–23, 54–735, 0.05–21, 0.005–1.3, 1.6–112, 4.5–20, 0.03–1.8, 6–46, 38–170 and 0.4–2.3 μg g− 1, respectively. At optimized experimental conditions, with both methods, effective in-situ analyte/matrix separation was achieved and calibration could be performed using calibration curves measured with aqueous standard solutions. In solid sampling GFAAS, before sampling, the platform was covered with graphite powder and, for determination of Si, also the Pd/Mg(NO3)2 modifier was used. In the determination of all analyte elements by solid sampling ETV-ICP-OES, Freon R12 was added to argon carrier gas. For solid sampling GFAAS and ETV-ICP-OES, the achievable limits of detection were within 5 (Cu)–130 (Si) ng g− 1 and 8 (Cu)–200 (Si) ng g− 1, respectively. The results obtained by these two methods for four boron nitride materials of different purity grades are compared each with the other and with those obtained in analysis of digests by ICP-OES. The performance of the two solid sampling methods is compared and discussed.  相似文献   

11.
Slurry sampling electrothermal vaporization (ETV) inductively coupled plasma mass spectrometry (ICP-MS) has been applied to determine As and Se in soil and sludge samples. The influences of instrument operating conditions and slurry preparation on the ion signals were reported. Pd and ascorbic acid were used as mixed modifiers to enhance the ion signals. The effectiveness of ETV sample introduction technique for alleviating various spectral interferences in ICP-MS analysis has been demonstrated. This method has been applied to determine As and Se in NIST SRM 2709 San Joaquin soil reference material and NIST SRM 2781 domestic sludge reference material and a farmland soil sample collected locally. Since the sensitivities of As and Se in slurry solution and aqueous solution were different, analyte addition technique was used to determine As and Se in these samples. The As and Se analysis results of the reference materials agreed with the certified values. The precision between sample replicates was better than 5% for all determinations. The method detection limit estimated from analyte addition curves was about 0.03 and 0.02 μg g−1 for As and Se, respectively, in original soil and sludge samples.  相似文献   

12.
Trace metals in fuels, except in the case of additives, are usually undesirable and normally they occur in very low concentrations in gasoline, requiring sensitive techniques for their determination. Coupling of electrothermal vaporization with inductively coupled plasma mass spectrometry minimizes the problems related to the introduction of organic solvents into the plasma. Furthermore, sample preparation as oil-in-water emulsions reduces problems related to gasoline analysis. In this work, a method for determination of Cu, Mn, Ni and Sn in gasoline is proposed. Samples were prepared by forming a 10-fold diluted emulsion with a surfactant (Triton X-100), after treatment with concentrated HNO3. The sample emulsion was pre-concentrated in the graphite tube by repeated pipetting and drying. External calibration was used with aqueous standards in a purified gasoline emulsion. Six samples from different gas stations were analyzed, and the analyte concentrations were found to be in the μg l−1 range or below. The limits of detection were 0.22, 0.02, 0.38 and 0.03 μg l−1 for Cu, Mn, Ni and Sn, respectively. The accuracy of the method was estimated using a recovery test.  相似文献   

13.
A new method for inductively coupled plasma atomic emission spectrometry (ICP-AES) determination of trace Sc and Y, based on gaseous compound introduction into the plasma as their thenoyltrifluoroacetone (TTA) complexes by electrothermal vaporization was developed. Using the reagent TTA as chemical modifier can not only enhance the analytical signals, but also reduce the vaporization temperature. At a temperature of 1,000 °C the trace Sc and Y can be vaporized completely into ICP. The factors affecting the formation of the chelate and its vaporization behavior, such as drying time, vaporization temperature/time, reaction medium and the amount of TTA, were investigated in detail. Under the optimized conditions (drying temperature/time 100 °C/10 s, vaporization temperature/time 1,000 °C/4 s), the limits of detection for Sc and Y were 19 pg and 34 pg (3), respectively, and the relative standard deviations for Sc and Y were 4.2% (c Sc=0.2 g mL–1; n=7) and 2.6% (c Y=0.5 g mL–1; n=7). The linear ranges of the calibration graphs cover three orders of magnitude. The method was applied to the analysis of the biological reference materials (GBW 07602, bush branches and leaves; GBW 07604, poplar leaves), and the results obtained were in good agreement with the certified values.  相似文献   

14.
Two different approaches were used to improve the capabilities of solid sampling (SS) electrothermal vaporization (ETV) coupled to inductively coupled plasma optical emission spectrometry (ICP-OES) for the direct analysis of powdered rice. Firstly, a cooling step immediately before and after the vaporization step in the ETV temperature program resulted in a much sharper analyte signal peak. Secondly, point-by-point internal standardization with an Ar emission line significantly improved the linearity of calibration curves obtained with an increasing amount of rice flour certified reference material (CRM). Under the optimized conditions, detection limits ranged from 0.01 to 6 ng g−1 in the solid, depending on the element and wavelength selected. The method was validated through the quantitative analysis of corn bran and wheat flour CRMs. Application of the method to the multi-elemental analysis of 4-mg aliquots of real organic long grain rice (white and brown) also gave results for Al, As, Co, Cu, Fe, Mg, Se, Pb and Zn in agreement with those obtained by inductively coupled plasma mass spectrometry following acid digestion of 0.2-g aliquots. As the analysis takes roughly 5 min per sample (2.5 min for grinding, 0.5–1 min for weighing a 4-mg aliquot and 87 s for the ETV program), this approach shows great promise for fast screening of food samples.  相似文献   

15.
Cloud point extraction (CPE) was used for the selective extraction and separation of cerium(IV) from aqueous solutions. The method is based on the formation of cerium(IV)-n-p-tolylbenzohydroxamic acid (n-TBHA) complex that is extracted into the micellar phase (Triton X-114) at a temperature above the cloud point temperature (CPT). After phase separation, the surfactant rich phase was diluted up to 1.0 mL and determined by inductively coupled plasma-optical emission spectrometry (ICP-OES). Under the optimum extraction conditions and instrument parameters, by preconcentration of only 10.0 mL of sample in the presence of 0.09% Triton X-114, an enhancement factor of 13.8 was obtained. The analytical curve was linear in the range of 1.5–1200 μg L−1 and the detection limit was 0.4 μg L−1. The method was applied to the determination of Ce(IV) in water samples with satisfactory results.  相似文献   

16.
A highly sensitive and accurate method for preconcentration and determination of ultra trace amounts of cobalt and nickel ions in water samples is proposed. The preconcentration is achieved using C18-silica extraction disks modified with 5-(6-methoxy-2-benzothiazoleazo)-8-aminoquinoline (MBTAQ). The retained ions on the prepared solid phase was eluted with 10 ml of 0.01 M nitric acid and measured by inductively coupled plasma-optical emission spectrometry (ICP-OES). The influence of the type and amount of eluent used, pH, sample and eluent flow rates, amount of MBTAQ and the effect of other ions on extraction efficiency were investigated. The limits of detection of the method were 0.08 and 0.06 μg l− 1 for cobalt and nickel, respectively, and provide an enrichment factor of 100. The results obtained on 10 successive extractions and elution cycles revealed relative standard deviations of 1.5 and 1.0% for cobalt and nickel, respectively. The proposed method has been applied to the determination of ultra trace amounts of cobalt and nickel ions in natural and synthetic water samples with satisfactory results.  相似文献   

17.
A new method for solid-phase extraction and preconcentration of trace amounts Hg(II) from environmental samples was developed by using sodium dodecyle sulphate-coated magnetite nanoparticles (SDS-coated Fe3O4 NPs) as a new extractant. The procedure is based on the adsorption of the analyte, as mercury-Michler's thioketone [Hg2(TMK)4]2+ complex on the negatively charged surface of the SDS-coated Fe3O4 NPs and then elution of the preconcentrated mercury from the surface of the SDS-coated Fe3O4 NPs prior to its determination by flow injection inductively coupled plasma-optical emission spectrometry. The effects of pH, TMK concentration, SDS and Fe3O4 NPs amounts, eluent type, sample volume and interfering ions on the recovery of the analyte were investigated. Under optimized conditions, the calibration curve was linear in the range of 0.2-100 ng mL−1 with r2 = 0.9994 (n = 8). The limit of detection for Hg(II) determination was 0.04 ng mL−1. Also, relative standard deviation (R.S.D.) for the determination of 2 and 50 ng mL−1 of Hg(II) was 5.2 and 4.7% (n = 6), respectively. Due to the quantitative extraction of Hg(II) from 1000 mL of the sample solution an enhancement factor as large as 1230-fold can be obtained. The proposed method has been validated using a certified reference materials, and also the method has been applied successfully for the determination of Hg(II) in aqueous samples.  相似文献   

18.
A procedure for the determination of As, Pb, Se and Sn in sediment slurries by electrothermal vaporization inductively coupled plasma mass spectrometry is proposed. The slurry, 1 mg ml−1, is prepared by mixing the sample ground to a particle size 50 μm with 5% v/v nitric and 1% v/v hydrofluoric acids in an ultrasonic bath. The slurry was homogenized with a constant flow of argon in the autosampler cup, just before transferring an aliquot to the graphite furnace. The tube was treated with Ru as a permanent modifier, and an optimized mass of 1 μg of NaCl was added as a physical carrier. The pyrolysis temperature was optimized through pyrolysis curves, and a compromised temperature of 800 °C was used; the vaporization temperature was 2300 °C. The effect of different acid concentrations in the slurry on the analyte signal intensities was also evaluated. The accuracy of the method was assured by the analysis of certified reference sediments MESS-2, PACS-2 and HISS-1 from the National Research Council Canada, SRM 2704 and SRM 1646a from the National Institute of Standards and Technology and RS-4 from a round robin test, using external calibration with aqueous standards prepared in the same medium as the slurries. The obtained concentrations were in agreement with the certified values according to the Student's t-test for a confidence level of 95%. The detection limits in the samples were: 0.17 μg g−1 for As; 0.3 μg g−1 for Pb; 0.05 μg g−1 for Se and 0.28 μg g−1 for Sn. The precision found for the different sediment samples, expressed as R.S.D. was 1–8% for As, 2–9% for Pb, 6–12% for Se and 3–8% for Sn (n=5).  相似文献   

19.
A new method using diluted reagents (nitric and hydrochloric acids and oxygen peroxide) and ultrasound energy to assist metals acid leaching with from edible seaweed was optimized. The method uses a first sonication at high temperature with hydrochloric acid as a previous stage to an ultrasound-assisted acid leaching with 7 ml of an acid solution containing nitric acid, hydrochloric acid and hydrogen peroxide at concentrations of 3.7, 3.0 and 3.0 M, respectively. Optimum conditions for the first sonication step were ultrasound energy at 17 kHz, sonication temperature at 65 °C, an acid volume of 2 ml, an hydrochloric acid concentration of 6.0 M and a sonication time of 10 min. It has been found that the first sonication stage at high temperature with hydrochloric acid is necessary to obtain quantitative recoveries for As, Ba, Fe and V. Otherwise quantitative recoveries were reached for the other elements investigated (Ca, K, Na, Mg, Cd, Cr, Cu, Mn, Ni, Pb and Zn). The repeatability of the ultrasound-assisted acid leaching method was around 10% for all elements. Adequate limit of detection and limit of quantification were reached by using inductively coupled plasma-optical emission spectrometry (ICP-OES) for measurements. The method resulted accurate after analysing several seaweed certified reference materials (IAEA-140/TM, NIES-03 and NIES-09). The method was finally applied to the multi-element determination in edible seaweed samples.  相似文献   

20.
Cadmium in the urine samples of patients with age-related disease forms a complex with a chelating agent, ammonium pyrrolidine dithio-carbamate, and the complex is extracted with methyl isobutyl ketone. One milliliter of urine provides three separate 200-μl aliquots of extract, so a preconcentration factor of 5/3 is observed. In this manner, the Cd is effectively separated from the complex urine matrix. An internal standard, Bi, is added to improve both precision and accuracy. The extracts are analyzed by inductively coupled plasma atomic emission spectrometry using a tungsten-coil as an electrothermal vaporizer. A 20-μl aliquot of the extract is injected directly onto the coil. Two Cd atomic emission lines are observed simultaneously: 228.8 nm and 226.5 nm. The limits of detection at these wavelengths are 0.04 and 0.2 μg/l, respectively. Without the extraction technique, the detection limit is 0.4 μg/l at the 228.8-nm line. With the internal standard technique, the accuracy as measured with a urine standard reference material is 98%. Six urine samples collected from patients with age-related diseases are found to contain Cd levels in the range 0.9 to 4.1 μg/l. The precision associated with the measurement of these real samples is 6.2% relative standard deviation. The technique provides off-wavelength background correction and simultaneous determination at two different wavelengths, so samples that are limited in volume can still be analyzed with a high degree of confidence.  相似文献   