首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Shih Y  Zen JM  Kumar AS  Chen PY 《Talanta》2004,62(5):912-917
Zinc pyrithione (ZPT) is an antibacterial and antifungal reagent that is often utilized for the antidandruff activity in hair-care shampoos with a composition level up to 1% in the formulation. It has some adverse effects to human and animal if consumed orally. A disposable type of cobalt phthalocyanide modified screen-printed carbon electrode (CoPc/SPE) in couple with flow injection analysis (FIA) was developed for easy and selective analysis of ZPT in commercial hair-care products. Under the optimized FIA conditions, the CoPc/SPE yielded a linear calibration plot in the window of 6–576 μM with sensitivity and detection limit of 1.65 nA μM−1 and 0.9 μM (i.e. 1.42 pg in 5 μl sample loop), respectively, in 0.1 M KOH solution at an applied potential of 0.3 V versus Ag/AgCl. Since the approach is simple, easy, selective, and inexpensive, it offers a potential application of daily ZPT analysis in hair-care products.  相似文献   

2.
This paper presents the construction of amperometric biosensors for the highly sensitive detection of carbamate insecticides based on the inhibition of acetylcholinesterase (AChE). This enzyme was immobilised by entrapment in an optimised sol-gel matrix on TCNQ-modified screen-printed electrodes. The enzyme activity was estimated by measuring the thiocholine produced by the enzymatic hydrolysis of the acetylthiocholine using TCNQ as mediator. Wild and genetically engineered AChEs from Drosophila melanogaster (Dm) were chosen for their high sensitivity towards insecticides, which substantially improves the LOD compared with cholinesterases from other sources. The wild type and three mutant enzymes were tested against three carbamate insecticides: carbaryl, carbofuran and pirimicard. The best LOD were obtained with the Y370A mutant for carbaryl (1 × 10−8 M), the E69W mutant for pirimicarb (2 × 10−8 M) and the I161V mutant for carbofuran (8 × 10−10 M). The biosensors were applied to the analysis of two potable water samples.  相似文献   

3.
Screen-printed silver electrodes (AgSPEs), without chemical modification, has been investigated as disposable sensors for the measurement of trace levels of Pb2+. Potential segment analysis indicates that the formation of underpotential and bulk depositions of Pb is not strongly coupled on the AgSPE. The possibility of determining Pb2+ at trace levels using the reversible underpotential deposition peak was examined by square-wave anodic stripping voltammetry without removal of oxygen. Under the optimized analytical conditions, the obtained sensitivity, linearity, and detection limit are 0.355 μA/ppb, 5-80 ppb (r=0.9992), and 0.46 ppb (S/N=3), respectively. The electrode is quite stable for repetitive measurements. The interference effect was thoroughly studied with various metals and no significant change in current was found in the determination of 5 ppb Pb2+. The practical applications were demonstrated to measure trace Pb2+ in natural waters.  相似文献   

4.
Gao Q  Wang W  Ma Y  Yang X 《Talanta》2004,62(3):477-482
The electrooxidation polymerization of phenothiazine derivatives, including azure A and toluidine blue O, has been studied at screen-printed carbon electrodes in neutral phosphate buffer. Both compounds yield strongly adsorbed electroactive polymer with reversible behavior and formal potentials closed to 0.04 V at pH 6.9. The modified electrodes exhibited good stability and electrocatalysis for NADH oxidation in phosphate buffer (pH 6.9), with an overpotential of more than 500 mV lower than that of the bare electrodes. Further, the modified screen-printed carbon electrodes were found to be promising as an amperometric detector for the flow injection analysis (FIA) of NADH, typically with a dynamic range of 0.5-100 μM.  相似文献   

5.
Sensitive and stable monitoring of heavy metals in seawater using screen-printed electrodes (SPE) is presented. The analytical performance of SPE coupled with square wave anodic stripping voltammetry (SWASV) for the simultaneous determination of Pb and Cd in seawater samples, in the low μg L−1 range, is evaluated. The stripping response for the heavy metals following 2 min deposition was linear over the concentration range examined (10-2000 μg L−1) with detection limits of 1.8 and 2.9 μg L−1 for Pb and Cd, respectively. The accuracy of the method was validated by analyzing metal contents in different spiked seawater samples and comparing these results to those obtained with the well-established anodic stripping voltammetry using the hanging mercury drop electrode. Moreover, a certified reference material was also used and the results obtained were satisfactory.  相似文献   

6.
抗坏血酸在普鲁士蓝修饰的丝网印刷电极上的电催化氧化   总被引:2,自引:0,他引:2  
制备了普鲁士蓝修饰的丝网印刷电极,研究了该修饰电极对抗坏血酸的催化氧化作用。在pH5.0的0.2mol/L磷酸盐缓冲溶液中,修饰电极对抗坏血酸显示出快速的电化学响应,较高的稳定性、重现性和催化活性,测定的线性范围为5.0×10-6~8.0×10-3mol/L,相关系数为0.998,检出限为3.0×10-6mol/L(3σ)。已对实际样品进行了测定。  相似文献   

7.
An electrochemical cell has been developed enabling amperometric steady-state- and flow-injection measurements with screen-printed arrays consisting of eight working electrodes (Ø = 1 mm) arranged radially around a printed Ag/AgCl reference electrode in the centre. The cell contained a rotator, providing similar hydrodynamics over all the working electrodes in the array, which was manually centered under the rotator. The reproducibility of steady-state measurements with eight-electrode platinum or gold arrays in this cell was studied by measuring and comparing currents from ferricyanide reduction at each electrode in the array. It was found that the relative standard deviation (R.S.D.) for the currents at different electrodes on one array was below 5%. Similar R.S.D. was found if measurements were compared between several arrays. This indicates that manual insertion/positioning of the eight-electrode array in the cell and hydrodynamics at the electrodes provided measurement reproducibility similar to the reproducibility of manufacturing eight-electrode platinum or gold arrays by screen-printing. A comparative study was performed between screen-printed and through mask sprayed carbon arrays. It was found that the reproducibility of the sprayed arrays was similar to that of the platinum or gold screen-printed arrays, with R.S.D. values below 6% regarding the variation between electrodes within the same array and the variation between different arrays. To enable flow-injection measurements, a tube (0.4 mm inner diameter) was inserted into a hole drilled through the centre of the steady-state cell rotator. This construction made it possible to inject the solution into the cell through the tube (not rotating), while the rotator was spinning over the eight-electrode array. It was found that this combination of flow-injection and mixing by a rotator provided a uniform current response over the array electrodes and that, at optimum conditions, the R.S.D. values between the eight electrodes in the array were nearly the same as in case of the steady-state measurements, i.e., below 5%.  相似文献   

8.
A flow injection amperometric immunoassay system based on the use of screen-printed carbon electrode for the detection of mouse IgG was developed. An immunoelectrode strip, on which an immunosorbent layer and screen-printed carbon electrode were integrated, and a proposed flow cell have been fabricated. The characterization of the flow immunoassay system and parameters affecting the performance of the immunoassay system were studied and optimized. Amperometric detection at 0.0 V (versus Ag/AgCl) resulted in a linear detection range of 30-700 ng ml−1, with a detection limit of 3 ng ml−1. The signal variation among electrode strips prepared from variant batch did not exceed 8.5% (n=7) by measuring 0.5 μg ml−1 antigen standard solution.  相似文献   

9.
A screen-printed amperometric biosensor based on carbon ink double bulk-modified with MnO2 as a mediator and glucose oxidase as a biocomponent was investigated for its ability to serve as a detector for bonded glucose in different compounds, such as cellobiose, saccharose, (-)-4-nitrophenyl-β-d-glucopyranoside, as well as in beer samples by flow-injection analysis (FIA). The biosensor could be operated under physiological conditions (0.1 M phosphate buffer, pH 7.5) and exhibited good reproducibility and stability. Bonded glucose was released with glucosidase in solution, and the free glucose was detected with the modified screen-printed electrode (SPE). The release of glucose by the aid of glucosidase from cellobiose, saccharose and (-)-4-nitrophenyl-β-d-glucopyranoside in solution showed that stoichiometric quantities of free glucose could be monitored in all three cases.The linear range of the amperometric response of the biosensor in the FIA-mode flow rate 0.2 mL min−1, injection volume 0.25 mL, operation potential 0.48 V versus Ag/AgCl) extends from 11 to 13,900 μmol L−1 glucose in free form. The limit of detection (3σ) is 1 μmol L−1 glucose. A concentration of 100 μmol L−1 yields a relative standard deviation of approximately 7% with five injections. These values correspond to the same concentrations of bonded glucose supposed that it is liberated quantitatively (incubation for 2 h with glucosidase).Bonded glucose could be determined in beer samples using the same assay. The results corresponded very well with the reference procedure.  相似文献   

10.
The performance characteristic of sensitive screen-printed (SPE) and carbon paste (CPE) electrodes was investigated for the determination of diphenhydramine hydrochloride (DPH) drug in pure, pharmaceutical preparations and biological fluids. Different experimental conditions namely types of materials used to prepare the working electrode (plasticizer), titrant, pH, temperature and life time were studied. Under these conditions, the SPE shows the best performance than CPE with respect to total potential change and potential break at the end point. The SPE and CPE exhibit suitable response to DPH in a concentration range of 1.0.10− 2 to 1.0.10− 6 mol/L with a limit of detection 9.70.10− 7 and 9.80.10− 7 mol/L, respectively. The slope of the system was 55.2 ± 1.0 and 54.7 ± 1.0 mV/decade over pH range 3.0–8.0 and 3–7 for SPE and CPE, respectively. Selectivity coefficients for DPH relative to a numbers of potential interfering substances were investigated. The SPE and CPE show a fast response time of 10 and 16 s and were used over a period of 2 months with a good reproducibility. The sensors were applied successfully to determine DPH in pharmaceutical preparations and biological fluids. The results are compared with the official method.  相似文献   

11.
This work reports on the performance of carbon nanotube modified screen-printed electrodes (SPE-MWCNT) for the selective determination of dopamine (DA) in the presence of ascorbic acid (AA) by adsorptive stripping voltammetry (AdSV). Several operating conditions and parameters were examined including the electrochemical pre-treatment and the previous AA interaction and DA accumulation in the presence AA at physiological conditions. Under the chosen conditions, DA peak current of differential pulse voltammograms increases linearly with DA concentration in the range of 5.0 × 10−8 to 1.0 × 10−6 mol L−1 with a limit of detection of 1.5 × 10−8 mol L−1 in connection with 600 s accumulation time. The sensitivity obtained for DA was independent from the presence or absence of AA; therefore, the proposed method can be readily applied to detect DA in real samples. The proposed methodology was successfully used for the quantification of DA in urine samples.  相似文献   

12.
A simple, low cost, and highly sensitive electrochemical sensor, based on a Nafion/ionic liquid/graphene composite modified screen-printed carbon electrode (N/IL/G/SPCE) was developed to determine zinc (Zn(II)), cadmium (Cd(II)), and lead (Pb(II)) simultaneously. This disposable electrode shows excellent conductivity and fast electron transfer kinetics. By in situ plating with a bismuth film (BiF), the developed electrode exhibited well-defined and separate peaks for Zn(II), Cd(II), and Pb(II) by square wave anodic stripping voltammetry (SWASV). Analytical characteristics of the BiF/N/IL/G/SPCE were explored with calibration curves which were found to be linear for Zn(II), Cd(II), and Pb(II) concentrations over the range from 0.1 to 100.0 ng L−1. With an accumulation period of 120 s detection limits of 0.09 ng mL−1, 0.06 ng L−1 and 0.08 ng L−1 were obtained for Zn(II), Cd(II) and Pb(II), respectively using the BiF/N/IL/G/SPCE sensor, calculated as 3σ value of the blank. In addition, the developed electrode displayed a good repeatability and reproducibility. The interference from other common ions associated with Zn(II), Cd(II) and Pb(II) detection could be effectively avoided. Finally, the proposed analytical procedure was applied to detect the trace metal ions in drinking water samples with satisfactory results which demonstrates the suitability of the BiF/N/IL/G/SPCE to detect heavy metals in water samples and the results agreed well with those obtained by inductively coupled plasma mass spectrometry.  相似文献   

13.
化学修饰电极的研究及其分析应用   总被引:6,自引:0,他引:6  
化学修饰电极的出现推动了电化学的发展,是现代电分析化学领域中一个重要的研究方向。本文较详细地评述了化学修饰电极的制备方法及其电分析应用,对其未来发展作了展望。  相似文献   

14.
Gurban AM  Rotariu L  Baibarac M  Baltog I  Bala C 《Talanta》2011,85(4):2007-2013
Simple and low cost biosensor based on screen-printed electrode for sensitive detection of some alkylphenols was developed, by entrapment of HRP in a nanocomposite gel based on single-walled carbon nanotubes (SWCNTs) and 1-butyl-3-methylimidazolium hexafluorophosphate ([BMIM][PF6]) ionic liquid. Raman and FTIR spectroscopy, CV and EIS studies demonstrate the interaction between SWCNTs and ionic liquid. The nanocomposite gel, SWCNT-[BMIM][PF6] provides to the modified sensor a considerable enhanced electrocatalytic activity toward hydrogen peroxide reduction. The HRP based biosensor exhibits high sensitivity and good stability, allowing a detection of the alkylphenols at an applied potential of −0.2 V vs. Ag/AgCl, in linear range from 5.5 to 97.7 μM for 4-t-octylphenol and respectively, between 5.5 and 140 μM for 4-n-nonylphenol, with a response time of about 5 s. The detection limit was 1.1 μM for 4-t-octylphenol, and respectively 0.4 μM for 4-n-nonylphenol (S/N = 3).  相似文献   

15.
报道了溶胶 凝胶硫离子传感器的制备方法及其在硫离子检测中的应用。采用循环伏安法(CV)对传感器修饰过程进行了表征,对其电化学过程的可行性及其响应机理进行了探讨。传感器在6.0×10-7~1.0mol L范围内符合Nernst方程式,线性相关系数r=0.9991,方法的检出限为2.0×10-7mol L。于4℃干态保存4周,响应信号基本不变,已用于环境水样的分析。  相似文献   

16.
This paper reports the interest of the novel 4-carboxyphenyl-grafted screen-printed electrodes (4-CP-SPEs) for sub-nanomolar analysis of uranium in water samples. Electrodes were easily prepared via electrochemically reduction of the corresponding diazonium salt. The stability of the grafted layer has been clearly demonstrated. Uranium detection was then achieved by immersing the grafted electrode into the sample solution, followed by the electrochemical measurement of adsorbed U(VI) by square wave voltammetry.Adsorption time was investigated so as to find the best compromise between analysis time, repeatability and reproducibility. Limit of detection and quantitation reached 7 × 10−10 and 2 × 10−9 mol L−1, respectively. Moreover, interference study was conducted with Zn(II), Cd(II), Pb(II) and Cu(II); no major interference was established. 4-CP-SPEs were finally applied for uranium determination in estuarine water demonstrating the convenience of these electrodes for environmental analysis.  相似文献   

17.
As the prostate cancer (PCa) progresses, sarcosine levels increase both in tumor cells and urine samples, suggesting that this metabolite measurements can help in the creation of non-invasive diagnostic methods for this disease. In this work, a biosensor device was developed for the quantification of sarcosine via electrochemical detection of H2O2 (at 0.6 V) generated from the catalyzed oxidation of sarcosine. The detection was carried out after the modification of carbon screen printed electrodes (SPEs) by immobilization of sarcosine oxidase (SOX) on the electrode surface. The strategies used herein included the activation of the carbon films by an electrochemical step and the formation of an NHS/EDAC layer to bond the enzyme to the electrode, the use of metallic or semiconductor nanoparticles layer previously or during the enzyme immobilization. In order to improve the sensor stability and selectivity a polymeric layer with extra enzyme content was further added. The proposed methodology for the detection of sarcosine allowed obtaining a limit of detection (LOD) of 16 nM, using a linear concentration range between 10 and 100 nM. The biosensor was successfully applied to the analysis of sarcosine in urine samples.  相似文献   

18.
Alzheimer's disease (AD) is a fatal neurodegenerative disease affecting approximately 26 million people world-wide, and the number is increasing as life expectancy increases. Since the only reliable diagnosis for the pathology is histochemical post-mortem examination, there is a rather urgent need for reliable, sensitive and quick detection techniques. Amyloid beta, being one of the established and widely accepted biomarkers of AD is a target biomolecule.  相似文献   

19.
Acetaminophenol or paracetamol is one of the most commonly used analgesics in pharmaceutical formulations. Acetaminophen is electroactive and voltammetric mechanistic studies for the electrode processes of the acetaminophenol/N-acetyl-p-quinoneimine redox system are presented. Carbon nanotubes modified screen-printed electrodes with enhanced electron transfer properties are used for the study of the electrochemical-chemical oxidation mechanism of paracetamol at pH 2.0.Quantitative analysis of paracetamol by using its oxidation process (in a Britton-Robinson buffer solution pH 10.0) at +0.20 V (vs. an Ag pseudoreference electrode) on an untreated screen-printed carbon electrode (SPCE) was carried out. Thus, a cyclic voltammetric based reproducible determination of acetaminophen (R.S.D., 2.2%) in the range 2.5 × 10−6 M to 1 × 10−3 M, was obtained. However, when SPCEs are used as amperometric detectors coupled to a flow injection analysis (FIA) system, the detection limit achieved for paracetamol was 1 × 10−7 M, one order of magnitude lower than that obtained by voltammetric analysis. The repeatability of the amperometric detection with the same SPCE is 2% for 15 successive injections of 10−5 M acetaminophen and do not present any memory effect.Finally, the applicability of using screen-printed carbon electrodes for the electrochemical detection of paracetamol (i.e. for quality control analysis) was demonstrated by using two commercial pharmaceutical products.  相似文献   

20.
一种以CdS为活性物质,用溶胶 凝胶技术制作的新型镉离子选择性电极。电极的斜率为29mV/decade,线性范围为1.0×10-1~6.0×10-5mol/L,检测下限为4.5×10-5mol/L,适宜的pH3.2~5.9,并对回收率进行了测定。  相似文献   