首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Ochratoxin A (OTA) is a mycotoxin (potentially carcinogenic secondary metabolite derived from fungal contamination), produced by some Aspergillus and Penicillium strains. Although present and legislated in different food sources in the human diet, the regulation for wine intake is still under discussion. The Office International de la Vigne et du Vin (OIV) recommended maximum levels in wine of 2 μg l−1. Some reports refer to OTA contamination in wines up to 15 μg l−1 and a special incidence in red wines from the southern regions of Europe and the north of Africa, but the majority of the data available are below 1 μg l−1. When working at such low concentrations, the problem of the uncertainty of the results becomes decisive towards the implementation of legal limits. In order to assess the global uncertainty associated with OTA determination in wines and widen the data set and knowledge of the situation in Portugal, 340 wines were analysed (189 Port Wine, 85 Vinho Verde and 66 wines from other regions in the country) by a high performance liquid chromatography (HPLC)-fluorescence detection (FD) method using immunoaffinity columns for clean up. OTA was detected in 69 wines by the method used, but in concentrations below 0.5 μg l−1, except for two which showed levels up to a maximum of 2.1 μg l−1. However, the global uncertainty for OTA is close to 37% for concentrations above 0.5 μg l−1, and therefore, such value can be below or exceed the OIV limit. In the vicinity of the limit of detection, 0.084 μg l−1, the global uncertainty rises exponentially to a maximum of about 70%. This can be an obstacle when discussing safety intake limits. Ethanol and glucose content did not interfere in the clean up of OTA by immunoaffinity columns.  相似文献   

2.
Fabiani A  Corzani C  Arfelli G 《Talanta》2010,83(1):281-285
Three different clean-up methods and two analytical techniques were compared to determine Ochratoxin A (OTA) in wines. The first clean-up used a MycoSep column, the second an immunoaffinity column (IAC) and the third consisted in a liquid-liquid extraction (LLE) using dichloromethane in acid conditions. Meanwhile, two different OTA determination techniques were also evaluated: a HPLC analysis using a fluorescence detector and an enzyme-linked immunosorbent assays (ELISA) method.Correlations between clean-up methods and analytical techniques to determine OTA in wine were made evaluating linearity, accuracy and precision.Both the two first clean-up methods (solid-phase extraction, SPE) showed a good linear fit (r2 = about 0.9999), followed by LLE. The use of immunoaffinity columns showed the best recoveries, even if also the SPE with MycoSep showed good recoveries while the LLE recoveries were the worst ones. The HPLC analysis showed good precision and accuracy, while ELISA method, even with a sufficient linearity, generally underestimated OTA content in wines.  相似文献   

3.
Ochratoxin A survey in Portuguese wine by LC-FD with direct injection   总被引:1,自引:0,他引:1  
A. Pena  F. Cerejo  L.J.G. Silva  C.M. Lino 《Talanta》2010,82(4):1556-1561
Wine and grape juices were identified as one of the most important sources of ochratoxin A (OTA), a mycotoxin with diverse toxic effects that naturally appears in food and foodstuffs all over the world.The aim of this study was to assess the OTA levels in Portuguese wines through the application of a simple and accurate method based on liquid chromatography (LC) with direct injection, followed by fluorescence detection (FD).Randomly selected wine samples were used to evaluate the performance of direct injection as efficient, fast, inexpensive and safe sample preparation method. The proposed method was successfully validated. The limit of quantification (LOQ) was 1.0 μg/L and OTA recoveries from wine samples, spiked at the three fortification levels, were higher than 85.4%, with RSDs lower than 9.6% for both red and white wines. The presence of OTA was confirmed by methyl ester derivatization followed by LC analysis.Data on OTA levels were obtained for 60 Portuguese red and white wine samples. OTA was found in 12 samples, nine (26%) red wine samples and three (12%) white wine samples. Only one red wine sample and one white wine sample presented a contamination level above the LOQ, with 1.23 and 2.4 μg/L, respectively. It should be pointed out that this white wine sample exceeded the EC maximum permitted level of 2.0 μg/L. The safe dose established as 120 ng/kg body weight/week was not exceeded by the weekly intake estimated for the samples contaminated above the LOQ.  相似文献   

4.
Gel-based and membrane-based flow-through immunoassay formats were investigated for rapid ochratoxin A (OTA) detection in red wine. The flow-through set-up consisted of an antibody containing gel or membrane placed at the bottom of a standard solid-phase extraction column (i.e. the flow-through column), combined with a clean-up column. Different clean-up methods were studied for red wine clarification and purification. The optimal method consisted of passing wine, diluted with an aqueous solution containing 1% polyethylene glycol (PEG 6000) and 5% sodium hydrogencarbonate, through strong anion exchange (SAX) silica. An immunoassay for OTA detection in red wine was optimized and a cut-off level at 2 μg L−1 according to EU legislation was achieved with both formats. A more significant colour difference between blank and spiked samples was observed for the gel-based assay making this superior to the membrane-based assay. The proposed rapid gel-based test was compared with a standard immunoaffinity column - high-performance liquid chromatography - fluorescent detection (IAC-HPLC-FLD) method and a good correlation of the results was obtained for naturally contaminated wine samples.  相似文献   

5.
《Analytica chimica acta》2004,513(1):41-47
A method for determination of ochratoxin A (OTA) in wine grapes is described, using extraction with a hydrogen carbonate and polyethylene glycol (PEG) solution (5% NaHCO3 and 1% PEG 8000), followed by immunoaffinity clean-up and liquid chromatography with fluorescence detection. Validation was made with spiked samples, in levels of 0.05 and 1 μg kg−1, with average recovery rates of 76% and relative standard deviations in repeatability and intermediate precision conditions of 8 and 12%, respectively. The limit of detection and limit of quantification in grapes were established at 0.004 and 0.007 μg kg−1, respectively. To evaluate further the accuracy and efficiency of this method, naturally contaminated grapes were also analysed by another method that involves extraction with acidified methanol, at levels ranging from 0.05 to 37 μg kg−1, and the results compared. A good correlation (r=0.9996) was found, with better performances in terms of precision for the new method. A survey was conducted on wine grapes from 11 Portuguese vineyards, during the harvest of 2002, using the proposed method. OTA was detected in three out of the 11 samples, at levels ranging from 0.035 to 0.061 μg kg−1.The new method meets all the criteria of the European Commission directive 2002/26/CE, that lays down the sampling and the analysis methods for the official control of OTA levels in foodstuffs. It is reliable for low levels of contamination (ng kg−1), and avoids the use of organic solvents in the extraction step.  相似文献   

6.
Occurrence of ochratoxin A in Turkish wines   总被引:1,自引:0,他引:1  
I. Var  B. Kabak   《Microchemical Journal》2007,86(2):241-247
A total of 95 wine samples including 34 white, 10 rosé and 51 red wines originating from four different Turkish areas were analysed for ochratoxin A (OTA). An analytical method based on immunoaffinity column (IAC) for clean-up and high performance liquid chromatography with fluorescence detection (HPLC-FD) was used to determine OTA in wines. The limit of detection (LOD) was estimated as 0.006 ng ml− 1 for white wine and 0.010 ng ml− 1 for rosé and red wines. The limit of quantification (LOQ) was estimated as 0.020 ng ml− 1 in white wine and 0.030 ng ml− 1 in rosé and red wines. Recovery experiments were carried out with spiked samples in the range 0.1–1 ng ml− 1 of OTA. The average OTA recoveries from spiked white wine samples varied from 79.43% to 85.07%; while the mean recoveries for rosé and red wine samples were in the range of 77.48–83.96% and 76.61–83.55%, respectively. OTA was detected in 82 (86%) wine samples at levels of < 0.006–0.815 ng ml− 1, which were below the maximum allowable limit established by the European Community. The mean OTA concentration in red wines was slightly higher than in white and rosé wines. Furthermore, our data indicate that the geographic region of origin has strong influence on OTA level for white, rosé and red wines: wines originating from Thrace (n = 44, mean = 0.158 ng ml− 1) and Aegean (n = 28, mean = 0.060 ng ml− 1) regions of Turkey were more contaminated with OTA compared with wines originating from central (n = 15, mean = 0.027 ng ml−1) and east Anatolia (n = 8, mean = 0.027 ng ml− 1) areas. This study showed that the occurrence of OTA in Turkish wines is high, but at levels that probably leads to a non-significant human exposure to OTA by consumption of wines.  相似文献   

7.
Competitive electrochemical enzyme-linked immunosorbent assays based on disposable screen-printed electrodes have been developed for quantitative determination of ochratoxin A (OTA). The assays were carried out using monoclonal antibodies in the direct and indirect format. OTA working range, I50 and detection limits were 0.05-2.5 and 0.1-7.5 μg L−1, 0.35 (±0.04) μg L−1 and 0.9 (±0.1) μg L−1, 60 and 100 μg L−1 in the direct and indirect assay format, respectively. The immunosensor in the direct format was selected for the determination of OTA in wheat. Samples were extracted with aqueous acetonitrile and the extract analyzed directly by the assay without clean-up. The I50 in real samples was 0.2 μg L−1 corresponding to 1.6 μg/kg in the wheat sample with a detection limit of 0.4 μg/kg (calculated as blank signal −3σ). Within- and between-assay variability were less than 5 and 10%, respectively. A good correlation (r = 0.9992) was found by comparative analysis of naturally contaminated wheat samples using this assay and an HPLC/immunoaffinity clean-up method based on the AOAC Official Method 2000.03 for the determination of OTA in barley.  相似文献   

8.
This work described the development and characterization of an electrochemical method using square wave voltammetry (SWV) combined with the use of modified magnetic nanoparticles (MNPs), which had shown a rapid and sensitive determination of ochratoxin A (OTA) in wine grapes (Cabernet Sauvignon, Malbec and Syrah) post-harvest tissues. The wine grapes were inoculated with Aspergillus ochraceus to obtain OTA in artificially infected samples. The OTA was directly determined using square-wave voltammetry. The current obtained is directly proportional to the concentration of OTA present in the samples. This method has been used for OTA determination in wine grapes and it was validated against a commercial ELISA test kit. The limits of detection calculated for electrochemical detection and the ELISA were 0.02 and 1.9 μg kg−1, respectively and the coefficients of variation for accuracy and precision dates were below 5.5%. This method promises to be suitable for the detection and quantification of OTA in apparently healthy fruits post-harvest for assuring safety and quality of food as well as consumer's health.  相似文献   

9.
A modified preparation of sample was developed for the determination of glutathione content in grape juice and wine by high-performance liquid chromatography with fluorescence detection, using on-line pre-column derivatization. Ice-cold deoxygenated methanol was used to deactivate the oxidation enzymes in juices or wines and keep the glutathione stable. The optimum recovery of glutathione content in grape juice and wine was obtained when either the sample of grape juice or wine was mixed in ice-cold deoxygenated methanol in the ratio 10:90 (v:v) and further diluted in sodium acetate buffer in the ratio 1:1 (v:v). The optimized method was validated for linearity, limit of detection, limit of quantification, precision and uncertainty. According to the validation data the method is appropriate for the determination of glutathione content in grape juice and wine. Glutathione contents in grape juices made from White Muscat grapes and Sauvignon Blanc wines were analysed. The average glutathione content in 28 young Sauvignon Blanc wines was 12.5 mg L−1.  相似文献   

10.
Analysis of terpenes in white wines using SPE-SPME-GC/MS approach   总被引:3,自引:0,他引:3  
Terpenes contribute to some white wines aroma, especially these produced from Muscat grapes and others aromatic ones of high terpene contents (Gewürtztramminer, Traminer, Huxel, Sylvaner). Terpenes are present in wine in free and bound (in a form of glycosides) forms. Analyses of bound terpenes are usually performed using solid phase extraction after hydrolysis of glycosides. A new method for determination of terpenes from wine, focused on determination of terpenes released after acidic hydrolysis, based on solid phase extraction (SPE) followed by solid phase microextraction (SPME) was developed. Non-polar (free) and polar (bound terpenes) fractions were separated on 500 mg C18 cartridges. Bound terpenes were sampled using SPME immediately after acidic hydrolysis in non-equilibrium conditions. Application of combined SPE-SPME approach allowed quantification of selected terpenes in lower concentrations than in SPE approach and added a selectivity to the method, which enabled detection of compounds non-detectable in SPE extracts. Results obtained by SPE and SPE-SPME approach were correlated for free terpenes and those released after acid hydrolysis 20 white wines obtained from different grape varieties (R2 = 0.923). Although developed for wine terpenes analysis, SPE followed by SPME approach has a great potential in analysis of other bound wine flavor compounds, especially those potent odorants present in trace amounts.  相似文献   

11.
This work presents an advantageous analytical procedure for the accurate determination of free trans-resveratrol in red and white wines. The proposed method involves solid-phase extraction (SPE), acetylation of the analyte in aqueous media and further determination by gas chromatography (GC) with mass spectrometry detection (MS). The use of a mixed-mode SPE sorbent provides an improvement in the selectivity of the extraction step; moreover, the presence of several intense ions in the electron impact mass spectra of its acetyl derivative guarantees the unambiguous identification of trans-resveratrol. Considering a sample intake of 10 mL, the method provides a limit of quantification (LOQ) of 0.8 ng mL−1 and linear responses for concentrations up to 2.5 μg mL−1, referred to wine samples. The average recovery, estimated with samples fortified at different concentrations in the above range, was 99.6% and the inter-day precision stayed below 8%. Trans-resveratrol levels in the analyzed wines varied from 3.4 to 1810 ng mL−1. Cis-resveratrol was also found in all samples. In most cases, equal or higher responses were measured for this latter form than for the trans-isomer. The reduced form of resveratrol, dihydro-resveratrol, was systematically identified in red wines.  相似文献   

12.
A HPLC method using a coulometric electrode array detector (CEAD) to analyse 4-ethylcatechol in wine was established. The procedure does not require any sample preparation or analyte derivatisation and performs chromatographic separation in a short time. The assay method is linear up to 1520 μg L−1 and precise (R.S.D. < 3%), with limits of detection and quantitation of 1.34 μg L−1 and 2.2 μg L−1, respectively. Recoveries in spiked wine samples ranged from 95% to 104% with a median value of 102% and matrix effects were not observed. The method was applied to the evaluation of the concentration of 4-EC in 250 commercial Italian wines. The red wines analysed had median, 75° percentile and maximum values of 37 μg L−1, 89 μg L−1 and 1610 μg L−1, respectively. For Sangiovese-based wines the mean ratios of 4-EP and 4-EG to 4-EC were 3.7:1 and 0.7:1, respectively. The feasibility of a cheaper fluorimetric approach to 4-EC quantification was investigated.  相似文献   

13.
14.
A feasible three-step method for ochratoxin A (OTA) rapid detection was developed and applied for OTA screening in high-coloured matrices such as liquorice, ginger, nutmeg, black pepper, white pepper and Capsicum spp. spices at a control level of 10 μg kg−1. The method was based on the clean-up tandem immunoassay column and involved three steps: extract application, washing step and application of chromogenic substrate. A significant simplification of the assay was reached by using an additional frit with conjugate inside the clean-up tandem immunoassay column. The time for analysis was less than 10 min, including 5 min for colour development. Results were visually evaluated as colour development for negative result or no colour development for positive result. The method was coupled with a simple methanol-based extraction. A total of 27 samples were screened for OTA with the proposed method. It was shown that two samples of red pepper and one sample of liquorice, pili-pili, chilli and cayenne were contaminated with OTA above the control level at 10 μg kg−1, but none of tested ginger, nutmeg, black pepper and white pepper.  相似文献   

15.
This study compared four extraction methods for the simultaneous determination of tetracyclines, macrolides, quinolones, sulphonamides and anthelmintics (including benzimidazoles and avermectins) in eggs by ultra-high pressure liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS). Solvent extraction, solid-phase extraction (SPE), matrix solid-phase dispersion (MSPD) and modified QuEChERS procedure were compared in terms of recovery and number of veterinary drugs extracted. The solvent extraction procedure with a clean-up step provided better results than the other tested procedures. The QuEChERS procedure was simpler and faster, but extracted fewer compounds than solvent extraction. MSPD did not extract tetracyclines and quinolones, whereas macrolides and tetracyclines were not extracted when SPE was applied. The solvent extraction procedure was validated, obtaining recoveries ranging from 60% (sulfaquinoxaline) to 119% (levamisole) with repeatability values (expressed as relative standard deviations, RSDs) lower than 20% at two concentration levels (10 and 100 μg kg−1), except for erythromycin, emamectin and ivermectin that showed RSD values close to 25% at 10 μg kg−1. Limits of quantification (LOQs) were always equal or lower than 5 μg kg−1. Finally the method was applied to egg samples, and erythromycin, enrofloxacin, difloxacin, thiabendazole, emamectin and fenbendazole were detected in four samples.  相似文献   

16.
A supramolecular solvent made up of reverse micelles of decanoic acid, dispersed in a continuous phase of THF:water, was proposed for the simple, fast and efficient microextraction of OTA in wheat prior to liquid chromatography-fluorescence determination. The method involved the stirring of 300 mg-wheat subsamples (particle size 50 μm) and 350 μL of supramolecular solvent for 15 min, subsequent centrifugation for 15 min and the direct quantitation of OTA in the extract, previous 5.7-fold dilution with ethanol/water/acetic acid (49.5/49.5/1), against solvent-based calibration curves. No clean-up of the extracts or solvent evaporation was needed. Interactions between the supramolecular solvent and major matrix components in the wheat (i.e. carbohydrates, lipids and proteins) were investigated. The reverse micelles in the extractant induced gluten flocculation but only in the coacervation region of lower analytical interest (i.e. at percentages of THF above 11%). The quantitation of OTA was interference-free. Representativity of the 300 mg-wheat subsamples was proved by analysing a reference material. OTA recoveries in wheat ranged between 84% and 95% and the precision of the method, expressed as relative standard deviation, was 2%. The quantitation limit of the method was 1.5 μg kg−1 and was below the threshold limit established for OTA in raw cereals by EU directives (5.0 μg kg−1). The method developed was validated by using a certified reference material and it was successfully applied to the determination of OTA in different wheat varieties from crops harvested in the South of Spain. OTA was not detected in any of the analysed samples. This method allows quick and simple microextraction of OTA with minimal solvent consumption, while delivering accurate and precise data.  相似文献   

17.
Headspace solid phase microextraction (HS-SPME) was investigated as a solvent-free alternative method for the extraction and determination of 4-ethylphenol (EP) and 4-ethylguaiacol (EG) in red wine by capillary gas chromatography with flame ionization detection (FID) and compared to liquid-liquid extraction.For HS-SPME, better results were obtained with saturated sodium chloride samples, at 55 °C, using a 85 μm polyacrylate fiber. An absorption time of 40 min was needed to reach the absorption equilibrium for EG. This 40-min duration corresponds to the beginning of EP equilibrium and was selected for the experiments. In these conditions, the calibration graphs were linear in the range 5-5000 μg l−1 and the sensitivity was nearly the same for the two compounds. The detection limits were in the low μg l−1 range. In model wine solutions, result obtained with the liquid-liquid extraction method exhibit a linear calibration between 25 and 10,000 μg l−1 with a detection limit of 1 μg l−1, but, the relative standard deviations of the EP and EG result in the low concentration range (<50 μg l−1) are higher than those obtained by HS-SPME (15% compared to 2% for EP and 12% compared to 5% for EG). Taking into account the numerous volatile compounds in wine, HS-SPME is a rapid and valid alternative technique for use in the determination of ethylphenols at trace levels.  相似文献   

18.
Two different strategies for the quantitative determination of 3-alkyl-2-methoxypyrazines in wine and must have been developed and validated. Comparison between both the techniques has been presented and the most adequate has been applied to the determination of these compounds in different samples of wine, made from several varieties of grapes, and also in different samples of must made from Cabernet Sauvignon grapes. Both the methods consisted of a dynamic headspace coupled with a solid-phase extraction (HS–SPE) and solid-phase extraction (SPE) directly from the sample, coupled with multidimensional gas chromatography–mass spectrometry system (MDGC–MS). Both of them require resins LiChrolut EN, and analyte elution has been carried out with dichloromethane. The repeatability of both methodologies was evaluated at two concentration levels. The relative standard deviations (RSD%) were acceptable in every case, but smaller when working with HS–SPE. The recoveries obtained for the three analytes with the two methodologies were almost 100%, with the exception of IBMP, which had a recovery of only 70% with HS–SPE. The linearity was satisfactory with both methods for the range of occurrence of methoxypyrazines in wine and must. The limits of detection of the direct SPE technique were much lower than those of HS–SPE in every case. Direct SPE method detection limits ranged from 0.09 to 0.15 ng L−1. The method based on direct SPE was chosen finally because it had better detection limits and was easier and quicker than the HS–SPE-based method. It has been applied to the determination of these components in 36 wine and 17 musts samples. The quantitative results suggest that the Spanish wines show meaningless amounts of these compounds. IBMP has been found just in between 1.9 and 15 ng L−1.  相似文献   

19.
An analytical methodology based on headspace solid phase microextraction (HS-SPME) combined with comprehensive two-dimensional gas chromatography—time-of-flight mass spectrometry (GC × GC–ToFMS) was developed for the identification and quantification of the toxic contaminant ethyl carbamate (EC) directly in fortified wines. The method performance was assessed for dry/medium dry and sweet/medium sweet model wines, and for quantification purposes, calibration plots were performed for both matrices using the ion extraction chromatography (IEC) mode (m/z 62). Good linearity was obtained with a regression coefficient (r2) higher than 0.981. A good precision was attained (R.S.D. <20%) and low detection limits (LOD) were achieved for dry (4.31 μg/L) and sweet (2.75 μg/L) model wines. The quantification limits (LOQ) and recovery for dry wines were 14.38 μg/L and 88.6%, whereas for sweet wines were 9.16 μg/L and 99.4%, respectively. The higher performance was attainted with sweet model wine, as increasing of glucose content improves the volatile compound in headspace, and a better linearity, recovery and precision were achieved. The analytical methodology was applied to analyse 20 fortified Madeira wines including different types of wine (dry, medium dry, sweet, and medium sweet) obtained from several harvests in Madeira Island (Portugal). The EC levels ranged from 54.1 μg/L (medium dry) to 162.5 μg/L (medium sweet).  相似文献   

20.
A total of 267 wine samples including 19 dessert, 186 red, 11 rosé and 51 white produced mostly in the years 1997–2002 in Italian and Hungarian regions were analyzed for ochratoxin A (OTA) using inmunoaffinity column (IAC) clean-up and HPLC with fluorimetric detection. None of Hungarian wine samples were contaminated with this mycotoxin. For Italian red wines, 84% of the samples were positive for OTA ranged from 0.01 to 4.00 ng/mL. Furthermore, OTA was detected in 63% of dessert, in 56% of rosé and in 19% of white wine samples ranged from 0.01 to 1.64, from 0.01 to 1.04 and from 0.01 to 0.21 ng/mL, respectively. A study of OTA daily exposure assessment in Italian wines was also carried out outlining a quite low contribution to the overall daily intake.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号